    							CHAPTER 4 NDA-24238
    Page 244
    Revision 3.0
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    [Circuit Card Accommodation into the New CPR]
    The steps below show the procedure to install the new CPR into the LPM.
    STEP  1 Using the Phillips Screwdriver, remove the 4 + 8 screws. Then, detach the
    front panel and top cover from the new CPR. (Refer to Figure 4-4)
    Figure 4-4   Removal of Front Panel and Top Cover from CPR
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    Top Cover
    CPRFront Panel
    As shown in Figure 4-4, detach the front panel of the new CPR by removing the 4 screws.
    Then, also lift away the top cover by removing the 8 screws. 
    						
    							NDA-24238 CHAPTER 4
    Page 245
    Revision 3.0
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    STEP 2 Insert the ISAGT (PZ-GT13) and LANI (PZ-PC19) cards into the 
    following slots of the new CPR (refer to Figure 4-5):
    ISAGT (PZ-GT13) →Slot #6 (ISA)
    LANI (PZ-PC19) →Slot #0 (PCI)(For Fusion Link)
    LANI (PZ-PC19) →Slot #1 (PCI)(When connecting MAT via 10-
    BASE T and PCI buses)
    LANI (PZ-PC19) →Slot #3 (PCI)(When LANI for Fusion Link is in dual configuration)
    Note
    Figure 4-5   Insertion of ISAGT and LANI Cards
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    CPRSlot 0 (PCI)
    LANIISAGT
    Slot 1 (PCI)Slot 3 (PCI)
    Slot 6 (ISA)
    Note:Accommodation of the second LANI (in PCI Slot 3) is optional. Figure 4-5 shows how to insert the ISAGT and LANI cards into CPR slots #6 (ISA), 
    and #0, #1 and #3 (PCI), respectively. 
    						
    							CHAPTER 4 NDA-24238
    Page 246
    Revision 3.0
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    STEP 3 Reattach the top cover and front panel by fastening the removed screws.
    (Refer to Figure 4-6)
    Figure 4-6   Reattachment of CPR Top Cover and Front Panel
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    After mounting the ISAGT/LANI cards, reattach the top cover by tightening the 8 screws. 
    Then, attach the Front Panel by fastening the 4 screws.
    Top Cover
    CPRFront Panel 
    						
    							NDA-24238 CHAPTER 4
    Page 247
    Revision 3.0
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    STEP 4 After turning “ON” the MBR key on the DSP of the new CPR, insert the
    new CPR into the LPM. Then, fasten the retained four screws. (Refer to
    Figure 4-7)
    Figure 4-7   Accommodation of New CPR into LPM
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    CPR LPM
    As shown in Figure 4-7, insert the new CPR into the LPM. Then, fasten the four screws. 
    						
    							CHAPTER 4 NDA-24238
    Page 248
    Revision 3.0
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    STEP 5 Insert the new HFD into the CPR. Then, fasten the two screws. 
    (Refer to Figure 4-8)
    Figure 4-8   Insertion of New HFD into CPR
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    By using the two screws, fasten the new HFD onto the CPR.
    LPM
    HFD (PZ-IO27/PZ-IO28) 
    						
    							NDA-24238 CHAPTER 4
    Page 249
    Revision 3.0
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    Replacement Procedure
     System Changeover of the CPU 
    from ACT to STBY mode.
     IMG0 lamp on the DSP begins to 
    flash green.
     Check the mate CPU’s lamp 
    indications:
    CPU OPE=Steady green
    IMG0, IMG1, IMG2, IMG3=Flash 
    green
     EMA SUP lamp on the EMA card is 
    green.
    Cable Name to be disconnected
    CPU #0: 10AL-(110) FLT CA
    CPU #1: 10AL-(130) FLT CA
    START
    Make a backup copy of the main data (office data, 
    CF/SPD data, etc.) onto the hard disk of the HFC.
    Turn ON the MBR key on the DSP of the CPU
    to be replaced. Then turn OFF the MBR key again.
    Confirm the mate CPUs ACT mode.
    Turn ON the EMA SUP key on the 
    EMA (PH-PC40) card.
    Disconnect the power alarm cable from 
    the PALM connector on PZ-PW92.
    A
    IMG1 IMG2 IMG3 CPUOPE WDT IMG0
    12
    34
    567
    8
    OFF
    12
    34
    567
    8
    OFF
    12
    34
    OFF
    MBR
    FRONT VIEWDSP
    ON
    4C026AE
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    PWR (PZ-PW92)
    FRONT VIEW
    SW
    ON
    OFF
    PALM -48V
    ON
    ALM OUTPWR
    INPWR 
    						
    							CHAPTER 4 NDA-24238
    Page 250
    Revision 3.0
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
     Refer to Figure 4-2 for CPR 
    face layout.
     Refer to Figure 4-2 for CPR 
    face layout.
     Refer to Figure 4-3 to replace
    the CPU.
    Cables to be disconnected
    Ether cable: UTP CTG5 ST CA-n
    Note:
     The kind of Ethernet cable may vary, 
    Disconnect power cables from the OUTPWR
    connector and INPWR connector on PZ-PW92.
    Disconnect Ethernet cables from the front
    connectors on the PZ-PC19 (LANI).
    Take off the four screws fastened onto the CPR.
    (Keep the removed screws.)
    B
    A
    Turn OFF the SW key on PZ-PW92.
    Disconnect bus cables from the front connectors
    on the PZ-GT16.
    Cables to be disconnected
    EXGT BUSCA-A for CN-A connector
    50-40 GT BUS CA-A for CN-B connector
    vary, depending on its connecting
    conditions. Cable to be disconnected from OUTPWR
    CPU #0: 6P-(4P-3P) PWR CA-A
    CPU #1: 6P-(4P-3P) PWR CA-B
    Cable to be disconnected from INPWR
    CPU #0: 4P-2P PWR CA-A
    CPU #1: 4P-2P PWR CA-B
    PWR (PZ-PW92)
    FRONT VIEW
    SW
    ON
    OFF
    PALM -48V
    ON
    ALM OUTPWR
    INPWR 
    						
    							NDA-24238 CHAPTER 4
    Page 251
    Revision 3.0
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
     Refer to Figure 4-3 to replace
    the CPU.
     Refer to Circuit Card Installation
    Into New CPR procedure in this
    section.
    Turn ON the MBR key on the DSP of 
    the new CPR.
    C
    B
    Extract the CPR from the LPM.
    Mount ISAGT (PZ-GT13) and LANI (PZ-PC19)
    cards onto the new CPR. Then, insert the new
    CPR into the LPM.
    IMG1 IMG2 IMG3 CPUOPE WDT IMG0
    12
    34
    567
    8
    OFF
    12
    34
    567
    8
    OFF
    12
    34
    OFF
    MBR
    FRONT VIEWDSP
    ON
    4C026AE 
    						
    							CHAPTER 4 NDA-24238
    Page 252
    Revision 3.0
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    Note: Do not connect the cable for the 
    Connect the disconnected bus cables
    to the connectors on the PZ-GT13.
    Turn ON the SW key on PZ-PW92.
    Connect the disconnected power alarm cable
    to the PALM connector on PZ-PW92.
    D
    C
    Connect the disconnected and Ethernet cables
    Connect the disconnected power cables to 
    the OUTPWR and INPWR connectors.
    PALM connector yet.
    to the connectors on the PZ-PC19.
    PWR (PZ-PW92)
    FRONT VIEW
    SW
    ON
    OFF
    PALM -48V
    ON OUTPWR
    INPWR
    ALM 
    						
    							NDA-24238 CHAPTER 4
    Page 253
    Revision 3.0
    UNIT/CIRCUIT CARD REPLACEMENT PROCEDURE
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
     EMA SUP lamp on the EMA card 
    goes OFF.
     IMG0 lamp on the DSP flashes 
    green.
    Flip the MBR key on the DSP of the new 
    CPR from ON to OFF.
    END
    D
    Turn OFF the EMA-SUP key on the EMA
    (PH-PC40) card.
    Confirm that IPL has completed successfully.
    Initial Program Load (IPL) 
    starts automatically.
    MBR(DSP)
    123
    IMG1 IMG2 IMG3 CPUOPE WDT IMG0
    12
    34
    567
    8
    OFF
    12
    34
    567
    8
    OFF
    12
    34
    OFF
    MBR
    FRONT VIEWDSP
    ON
    4C026AE 
    						