    							CHAPTER 8 NDA-24238
    Page 604
    Revision 3.0
    MAINTENANCE COMMANDS
    MEM_HDD_N:Data Control Between Memory and HDD for NDM
    1. Functional Outline
    This command, available at the NCN only, is used to save/verify a series of Office Data from the Memory of
    all Local Nodes to the HDD of each same node. 
    2. Parameters
    Input data
    Direction Select: MEM to HDD
    Verify HDD against MEM
    Data Type Selection: Data Memory
    Note 1
    Name Display
    Wireless Call Forwarding
    Call Forwarding
    Speed Calling
    User Assign Soft Key 
    Number Sharing 
    Note 2
    Call Block (for software Release 5 or later)
    LP Select: The parameter is valid when Call Forwarding, Speed Calling, User Assign Soft
    Key, Number Sharing or Call Block data is designated.
    Auto Verify Afterward
    Note 1:When Data Memory is selected, Network Data Memory (NDM) and Local Data Memory (LDM) are
    also saved/verified simultaneously.
    Note 2:By saving the Number Sharing data, the data concerning Dual Station Calling Over-FCCS (available
    for Release 5 or later software) is also saved/verified automatically.
    Display data
    Information: FPC of Node in which saving/verifying is executed
    Result of the execution
    Direction: MEM to HDD
    Verify HDD against MEM
    Data Type: Selected Data Type 
    						
    							NDA-24238 CHAPTER 8
    Page 605
    Revision 3.0
    MAINTENANCE COMMANDS
    MFCH:Make Busy of FCCH
    1. Functional Outline
    This command is used to set or reset the make busy state of the FCH card.
    2. Parameters
    Input Data
    FCHN: FCH Number [1-255]
    MB: Make Busy Information [0/1]
    0=Make Idle
    1=Make Busy 
    						
    							CHAPTER 8 NDA-24238
    Page 606
    Revision 3.0
    MAINTENANCE COMMANDS
    PMBU:Port Microprocessor Back Up
    1. Functional Outline
    This command saves the contents of Port Microprocessor (PM) onto Floppy Disk (FD) or verifies them.
    Information of firmware (Program Code) also appears on the screen.
    2. Parameters
    Input data
    Direction Select: Port Microprocessor to MAT
    Verify Port Microprocessor
    Verify PM with Error List Auto Verify Afterward can be performed when desig-
    nating Port Microprocessor to MAT.
    PM Information: Module Group
    Unit
    Group
    Data Size (1-6)
    1=2 Kbytes
    2=4 Kbytes
    3=8 Kbytes
    4=16 Kbytes
    5=32 Kbytes
    6=64 Kbytes
    Display data
    Office
    SP Number: Information of firmware (Program Code)
    SP Issue: Information of firmware (Program Code) 
    						
    							NDA-24238 CHAPTER 8
    Page 607
    Revision 3.0
    MAINTENANCE COMMANDS
    RALM:Release Alarm
    1. Functional Outline
    This command clears the fault indications.
    2. Parameters
    Input data
    WRT: Y=Alarm is released
    N=Not released
    RETURN TO MENU?: Y=Return to MENU
    N=Start operation again
    Display data
    Alarms Released 
    						
    							CHAPTER 8 NDA-24238
    Page 608
    Revision 3.0
    MAINTENANCE COMMANDS
    RALMN:Release Alarm for NDM
    1. Functional Outline
    This command, available at the NCN only, clears the fault indications of all the Nodes by clicking the release
    button on the display. 
    2. Parameters
    Display data
    FPC: FPC of alarm released Nodes
    Status: Result of releasing the alarm
    OK/NG 
    						
    							NDA-24238 CHAPTER 8
    Page 609
    Revision 3.0
    MAINTENANCE COMMANDS
    RLST:Release Station/Trunk
    1. Functional Outline
    This command releases a station or trunk.
    2. Parameters
    Input data
    TYPE: Type of Select (1-4)
    1=Stations
    2=Trunk
    3=LENS
    4=Connection Trunk
    TN:
    Note 1
    STN: Maximum 6 digits  Note 1
    RT:Note 2
    TK:Note 2
    LENS:Note 3
    Connection RT: (1-1023)  Note 4
    Connection TK: (1-4095) Note 4
    Note 1:
    This parameter is valid only when TYPE=1.
    Note 2:This parameter is valid only when TYPE=2.
    Note 3:This parameter is valid only when TYPE=3.
    Note 4:This parameter is valid only when TYPE=4.
    Display data
    STATUS: Status of Station/Trunk (1-4)
    1=Idle
    2=Busy
    3=Lockout
    4=Make Busy
    FPC: Fusion Point Code (1-253)
    INFORMATION: Information of the connected party 
    Note
    Note:
    This parameter appears only when STATUS=2. 
    						
    							CHAPTER 8 NDA-24238
    Page 610
    Revision 3.0
    MAINTENANCE COMMANDS
    RLST_T:Release of Station/Trunk – Telephone Number
    1. Functional Outline
    This command is used to release a station/trunk, by using Telephone Numbers. This command is available at
    NCN (for Fusion network) only. 
    2. Parameters
    Input Data
    TYPE: Telephone Number
    Trunk
    LENS
    Connection Trunk
    UGN: User Group Number 
    Note 1
    TELN: Telephone Number (max. 16 digits)Note 1
    RT: External/Internal Route Number Note 2
    TK: Trunk Number Note 2
    LENS: Line Equipment Number Note 3
    C_RT: Connection Route Number (1-1023) Note 4
    C_TK: Connection Trunk Number (1-4095) Note 4
    Note 1:
    This parameter is valid when “Telephone Number” is designated in the “TYPE” selection list box.
    Note 2:This parameter is valid when “Trunk” is designated in the “TYPE” selection list box.
    Note 3:This parameter is valid when “LENS” is designated in the “TYPE” selection list box
    Note 4:This parameter is valid when “Connection Trunk” is designated in the “TYPE” selection list box.
    Display Data
    FPC: Fusion Point Code (1-253)
    TN: Tenant Number 
    Note 5
    STN: Physical Station Number 
    (max. 5 digits for Business/max. 6 digits for Hotel system) 
    Note 5
    Note 5:
    This data is displayed when “Telephone Number” is designated in the “TYPE” selection list box. 
    						
    							NDA-24238 CHAPTER 8
    Page 611
    Revision 3.0
    MAINTENANCE COMMANDS
    STATUS: Status of Station/Trunk (1-5)
    1=Idle
    2=Busy
    3=Lockout
    4=Make Busy
    5=Now Calling
    INFORMATION: Information on the connected party 
    Note 6
    ERN: Area Number (1-32) Note 7
    GRN: Group Number (1-8) Note 7
    CSN/ZTN: CS/ZT Number (1-32) Note 7
    PCN: PHS Community Number (1-1024) Note 7
    Note 6:
    This data is displayed when “STATUS” =2 (Busy).
    Note 7:This data is for Wireless System only.
    Buttons
    Get: Click to get information on the station/trunk.
    Release: Click to execute the station/trunk release.
    Exit: Click to exit this command. 
    						
    							CHAPTER 8 NDA-24238
    Page 612
    Revision 3.0
    MAINTENANCE COMMANDS
    SINZ:System Initialization
    1. Functional Outline
    This command initializes the PBX from the MAT. At the time of system initialization, this command allows
    the programs and the office data to be loaded from a Hard Disk of PBX into the RAM of PBX.
    2. Parameters
    Input data
    TYPE: Kind of Initialization (1-4)
    1=System Initialize
    2=System Initialize Office Data Load & System Initialize
    3=System Initialize Program Load & System Initialize
    4=System Initialize Program & Office Data Load & System Initialize
    Note:When the system is initialized, the MAT is once disconnected. Then, log in to the system again. 
    						
    							NDA-24238 CHAPTER 8
    Page 613
    Revision 3.0
    MAINTENANCE COMMANDS
    SPTS:Scanning of Port Status
    1. Functional Outline
    This command displays momentarily the working status of Port Microprocessor (PM) on Module Group (MG),
    Unit, and Group basis.
    2. Parameters
    Input data
    MG
    Unit
    Group
    Interval: Unit for this parameter is in seconds.
    Entry Procedure
    Type 1: By MG
    Display of Scanning by Designating MG (Figure 8-1)
    Package Status PM: Not Mounted 
    Note
    ID: Idle at least one
    BY: All Busy
    MB: Under Make Busy Status
    Note:This information appears when the circuit card is in make busy status (MB key is set upward) or when
    the designated location has no circuit card. 
    						
    All NEC manuals Comments (0)