    							CHAPTER 3 NDA-24238
    Page 104
    Revision 3.0
    SYSTEM MESSAGES
    ➄ Called Party Information
    Station to Station Call
    OG Call to outside (IC Call from outside)
    b4-b7 b0-b3
    (a)
    Te n a n t  N o .
    Te n a n t  N o .
    DC0 DC1
    DC2 DC3
    DC4 DC5(a) Type of called party
    00 = Station
    01 = Attendant Console
    b7 b6 b5 b4 b3 b2 b1 b0
    b0-b7
    Route No. (Hex)
    Route No. (Hex)
    Trunk No. (Hex)
    Trunk No. (Hex)b4-b7 b0-b3
    Route No. (Hex)
    Route No. (Hex)
    Trunk No. (Hex)
    Trunk No. (Hex)
    DC0 DC1
    DC2 DC3
    DC4 DC5
    DC6 DC7
    DC8 DC9
    DC10 DC11
    DC12 DC13
    DC14 DC15
    DC16 DC17
    DC18 DC19 
    						
    							NDA-24238 CHAPTER 3
    Page 105
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the SMDR output buffer usage rate has exceeded the value assigned to ASYD,
    SYS1, Index 249.
    ➀ Detail Information
    (a) FS = 0, FE = 0/1
    ➁
    1: XXXX XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b0
    Default Alarm:
    SUP6-OSMDR Output Buffer Overflow AlarmDefault Grade:
    1Grade Modified: Lamp Modified:
    b0-b3: FS
    b4-b7: FE
    This system message varies depending on the data.
    FSFEMEANING
    (a) 0 0 SMDR output buffer usage rate exceeds the value 
    assigned by ASYD, SYS1, Index 249.
    (a) 0 1 After SMDR output buffer usage rate exceeds the 
    value assigned by ASYD, SYS1, Index 249, usage 
    rate lowered less than the value assigned by Index 
    250.
    (b) 1 0 -
    (c) 2 0 Data output is impossible due to SMDR apparatus 
    failure.
    b0: 0/1 = Data assigned by the ASYD, SYS1, Index 249, 250 is valid/
    invalid 
    						
    							CHAPTER 3 NDA-24238
    Page 106
    Revision 3.0
    SYSTEM MESSAGES
    ➂ Buffer Usage Rate Assigned by 
    ASYD, SYS1, Index 249
    ➃ Buffer Usage Rate Assigned by 
    ASYD, SYS1, Index 250
    (b) FS = 1, FE = 0
    ➁
    ➂ 
    Overflow Rate
    ➃ Overflow Rate b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b2 b1 b0
    b7 b0
    b7 b6 b5 b4 b0
    b0-b3: Units
    b4-b7: Tens
    b0-b3: Units
    b4-b7: Tens
    b0: Fault Grade by ALMG command
    00 = NON CONT 01 = SUP
    10 = MN 11 = MJ
    b0: 0/1 = -/100% Overflow
    b4-b7: 1-9 = 10%-90% Overflow 
    						
    							NDA-24238 CHAPTER 3
    Page 107
    Revision 3.0
    SYSTEM MESSAGES
    (c) FS = 2, FE = 0
    ➁ SMDR Group No.
    ➂ Port No.
    ➃ Not used
    (d) FS = 3, FE = 0
    ➁
    b7 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b3 b2 b1 b0
    b0-b3: SMDR Group No. to which failure occurred
    b0-b7: Port No. allocated for SMDR Group to which failure occurred (0-7)
    b0-b3: SMDR Group No. to which failure occurred 
    						
    							CHAPTER 3 NDA-24238
    Page 108
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the SMDR output buffer usage rate has been lowered to less than the value as-
    signed in the ASYD, SYS1, Index 250 after the rate exceeds the value assigned by Index 249.
    ➀ Detail Information
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON6-PSMDR Output Buffer Overflow ReleaseDefault Grade:
    0Grade Modified: Lamp Modified:
    b0-b7: 00H = After SMDR output buffer usage rate exceeds the value 
    assigned by ASYD, SYS1, Index 249, the rate lowered less than the 
    value assigned by Index 250. 
    						
    							NDA-24238 CHAPTER 3
    Page 109
    Revision 3.0
    SYSTEM MESSAGES
    This message displays after the office data is loaded and system initialization has executed.
    ➀ 
    ➁ 
    Load Status
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b15 b11 b9 b8
    Default Alarm:
    NON7-ASystem Initialize With Data LoadDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = IPL/PWR ON
    b1: 0/1 = Load Key OFF/ON
    b2: 0/1 = IPL KEY/MAT INITIAL
    b3: 0/1 = Program load is executed/-
    b4: 0/1 = -/Phase1 Restart Note 1
    b0: Office Data Load Status
    0/1 = Load OK/NG
    b1: Call Forwarding Data Load Status
    0/1 = Load OK/NG
    b2: Individual Speed Calling Data Load Status
    0/1 = Load OK/NG
    b3: Wireless Call Forwarding Data Load Status
    0/1 = Load OK/NG
    b4: Name Display Data Load Status
    0/1 = Load OK/NG
    b5: Network DM Load Status
    0/1 = Load OK/NG
    b6: Local DM Load Status
    0/1 = Load OK/NG
    b7: 0/1 = DM Load/Non Load
    b8: User assign Soft Key Data Load Status
    0/1 = Load OK/NG
    b9: Number Sharing Data Load Status
    0/1 = Load OK/NG Note 2
    b11: Call Block Data Load Status
    0/1 = Load OK/NG 
    						
    							CHAPTER 3 NDA-24238
    Page 110
    Revision 3.0
    SYSTEM MESSAGES
    Note 1:
    Phase1 Restart is executed when initializing the system without disrupting the following two-way con-
    nections that have already been established:
     Basic two-way connections (STN-STN, STN-TRK, TRK-TRK)
     Fixed connections
     Two-way connections established on a Fusion link
    For more details, see Section Chapter 6, Section 12.2.3.
    Note 2:Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS. 
    						
    							NDA-24238 CHAPTER 3
    Page 111
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when system initialization is activated.
    ➀
    Note:Phase1 Restart is executed when initializing the system without disrupting the following two-way
    connections that have already been established:
     Basic two-way connections (STN-STN, STN-TRK, TRK-TRK)
     Fixed connections
     Two-way connections established on a Fusion link
    For more details, see Chapter 6, Section 12.2.3.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b4 b3 b2 b0
    Default Alarm:
    NON7-BSystem InitializeDefault Grade:
    3Grade Modified: Lamp Modified:
    b2: 0/1 = IPL KEY/MAT INITIAL
    b3: 0/1 = Program Load/Non Load
    b4: 0/1 = -/Phase1 Restart Note 
    						
    							CHAPTER 3 NDA-24238
    Page 112
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MBR switch on the GATE card is turned ON at the time of CPU changeover
    or speech path changeover.
    ➀ Self-CPU Restart information
    ➁ Mate-CPU Restart information
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b5 b4 b3 b0
    b7 b5 b4 b3 b0
    Default Alarm:
    NON7-CCPU MBR Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart) 
    						
    							NDA-24238 CHAPTER 3
    Page 113
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MBR switch on the GATE card is turned OFF at the time of CPU changeover
    or speech path changeover.
    ➀ Self-CPU Restart information
    ➁ Mate-CPU Restart information
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b5 b4 b3 b0
    b7 b5 b4 b3 b0
    Default Alarm:
    NON7-DCPU MBR Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 =  -/Data  Copy  Restart  (for  Dual-CPU  system  only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart)
    b0: 0/1 = -/Monitor Restart
    b3: 0/1 = -/Initialization
    b4: 0/1 = -/Data Copy Restart (for Dual-CPU system only)
    b5: 0/1 = -/MB control
    b7: 0/1 = ACT/STBY (active system indication after restart) 
    						