    							CHAPTER 3 NDA-24238
    Page 154
    Revision 3.0
    SYSTEM MESSAGES
    ➄ Error Status of No. 0 system HD
    ➅ Backup data to No. 1 system
    ➆ Error Code of No. 1 system HD
    ➇ Error Status of No. 1 system HD
    ➈ Data analyzed by NEC Engineers
    ➉ Data analyzed by NEC Engineers b7 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b3 b2 b1 b0
    Error occurs;
    b0: 0/1 = -/At the time data transfer started
    b1: 0/1 = -/At the time data saved
    b2: 0/1 = -/At the time data transfer ended
    b3: 0/1 = -/At the time file transfer started
    Refer to No. ➂
    Refer to No.➃
    Refer to No.➄ 
    						
    							NDA-24238 CHAPTER 3
    Page 155
    Revision 3.0
    SYSTEM MESSAGES
    [C0H] Detection of Remaining Link Abnormal End
    ➀ Performed Diagnosis Item
    ➁ ED (Error Data)
    1: C000 XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀   ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b1 b0
    [C0H] Detection of Remaining Link Abnormal End
    b1
    b0
    0 1 = CPU is not normal
    1 0 = Data transfer error
    1 1 = No Answer error 
    						
    							CHAPTER 3 NDA-24238
    Page 156
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MB switch on the PLO card is turned on while extracting or inserting a circuit
    card
    .
    ➀ Faulty PLO card No.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    Default Alarm:
    NON7-UPLO MB Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = PLO No. 0 system/PLO No. 1 system 
    						
    							NDA-24238 CHAPTER 3
    Page 157
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MB switch on the PLO card is turned off while extracting or inserting a circuit
    card
    .
    ➀ Faulty PLO card No.
    ➁ Status of PLO card at the time of 
    failure detection (Scan Data 1)
    ➂ Status of PLO card at the time of 
    failure detection (Scan Data 2)
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b4 b1 b0
    Default Alarm:
    NON7-VPLO MB Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = PLO No. 0 system/PLO No. 1 system
    b0: 0/1 = Clock STBY/ACT
    b1: 0/1 = PLO Synchronizing/PLO self-running or drifting
    b2: 0/1 = -/Input clock down
    b3, b4: Route of Input clock (see table)
    b5: 0/1 = -/PLO input all down
    b6: 0/1 = -/PLO output down
    b7: 0/1 = -/Drifting
    b4b3Connected With Primary 
    Oscillator (M-OSC)Connected With 
    External Clock
    0 0 NO. 0 M-OSC Route 0
    0 1 NO. 1 M-OSC Route 1
    10 - Route 2
    11 - Route 3
    b0: 0/1 = -/n × 5msec clock down
    b1: 0/1 = -/Frame Synchronization down from SYNC card
    b4: 0/1 = -/Internal OSC clock down  
    						
    							CHAPTER 3 NDA-24238
    Page 158
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a clock down failure occurs in the CCH/DCH circuit card. When this message is
    indicated, the related CCH/DCH card is placed into make-busy status
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-ACCH Clock FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24238 CHAPTER 3
    Page 159
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when C-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit
    card has occurred
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-BCCH C-Level Infinite Loop Failure (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24238
    Page 160
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when C-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit
    card has occurred
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-CCCH C-Level Infinite Loop Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24238 CHAPTER 3
    Page 161
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a Port Microprocessor (PM) of the CCH/DCH card did not send an answer to the
    CPU
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-DCCH Lock-Up Failure (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24238
    Page 162
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a Port Microprocessor (PM) of the CCH/DCH card did not send an answer to the
    CPU
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-ECCH Lock-Up Failure (Temporary)Default Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24238 CHAPTER 3
    Page 163
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when B-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit
    card has occurred
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-FCCH B-Level Infinite Loop Failure (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						