CHAPTER 3 NDA-24238 Pag e 6 4 Revision 3.0 SYSTEM MESSAGES This message displays when the changeover of the TSW system is executed. ➀ACT side Speech Path (TSW) after changeover ➁ Reason for changeover 1: XXXX 0000 XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 XXXX XXXX ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON1-TTSW ACT Change ReportDefault Grade: 2Grade Modified: Lamp Modified: b0: 0/1 = No. 0 system/No. 1 system b7-b4b3-b0CardContents 01TSWI/O Alarm 2 32ch Clock down, FH down 3 24ch Clock down, FH down 6 TSW SW Memory write failure 9 I/O Alarm release 10 32ch Clock down recovered, FH down recovered 11 24ch Clock down recovered, FH down recovered 13 TSW MBR key OFF 15 TSW ACT/STBY changeover by CMOD command 6 1 MUX MUX circuit card Ready failure 2 MUX circuit card clock failure
NDA-24238 CHAPTER 3 Page 65 Revision 3.0 SYSTEM MESSAGES ➂~➅ Status of ACT side TSW card ➆~➉ Status of ST-BY side TSW card b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b0-b3, b4-b7: The status of TSW card in each MG (00~07) 0000 = Normal 0001 = Abnormal (Impossible to make links) ➂MG00 MG01 ➃MG02 MG03 ➄MG04 MG05 ➅MG06 MG07 b7-b4 b3-b0 b0-b3, b4-b7: The status of TSW card in each MG (00~07) 0000 = Normal 0001 = Abnormal (Impossible to make links) ➆MG00 MG01 ➇MG02 MG03 ➈MG04 MG05 ➉MG06 MG07 b7-b4 b3-b0
CHAPTER 3 NDA-24238 Pag e 6 6 Revision 3.0 SYSTEM MESSAGES This message displays when DLKC data transfer failure (temporary), shown in message [1-V], occurs more than 16 times an hour. At this time, the faulty DLKC card is down and its switching network automatically changes over. ➀ System status of faulty DLKC card ➁ Error Code ➂ Details on Switching Network 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b1 b0 Default Alarm: MN1-UDLKC Data Transfer Failure (Permanent)Default Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = No. 0 system / No. 1 system 01H: Firmware fault 02H: Data transfer time out to DLKC 03H: No answer time out (at DLKC) 04H: Data parity error b0: Status of Speech Path System (including DLKC) 0/1 = No. 0 system is ACT/No. 1 system is ACT b1: Status of basic clock 0/1 = No. 0 system is ACT/No. 1 system is ACT
NDA-24238 CHAPTER 3 Page 67 Revision 3.0 SYSTEM MESSAGES This message displays when a data sending error or no answer error occurs at the time of data transfer from CPU to DLKC card. ➀ System status of faulty DLKC card ➁ Error Code ➂ Details on Switching Network Note:This data displays when the STBY DLKC card is detected as faulty. 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b1 b0 Default Alarm: SUP1-VDLKC Data Transfer Failure (Temporary)Default Grade: 1Grade Modified: Lamp Modified: b0: 0/1 = No. 0 system / No. 1 system 01H: Firmware fault 02H: Data transfer time out to DLKC 03H: No answer time out (at DLKC) 04H: Data parity error b0: Status of Speech Path System (including DLKC) 0/1 = No. 0 system is ACT/No. 1 system is ACT b1: Status of basic clock 0/1 = No. 0 system is ACT/No. 1 system is ACT b7: Information on Reset of STBY DLKC Note 0/1 = - /STBY DLKC card was reset
CHAPTER 3 NDA-24238 Pag e 6 8 Revision 3.0 SYSTEM MESSAGES This message displays when a failure such as internal clock down occurred to PLO is restored. ➀ Restoration of PLO fault ➁ Current Status of PLO card ➂ Current Status of PLO card 1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ ➂ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b4 b1 b0 Default Alarm: NON1-WPLO RestoreDefault Grade: 3Grade Modified: Lamp Modified: b0: 0/1 = PLO No. 0 system/PLO No. 1 system b0: 0/1 = Clock is in STBY side/ACT side b1: 0/1 = PLO synchronizing/PLO self running or drifting b2: 0/1 = -/Input clock down b3, b4: Route of input clock (see the table below) b5: 0/1 = -/PLO input all down b6: 0/1 = -/PLO output down b7: 0/1 = -/Drifting b4b3Connected With Primary Oscillator (M-OSC)Connected With External Clock 0 0 No. 0 M-OSC Route 0 0 1 No. 1 M-OSC Route 1 10 – Route 2 –Route 3 b0: 0/1 = -/5msec clock down b1: 0/1 = -/Frame Synchronization from SYNC card is down b4: 0/1 = -/Internal OSC clock down
NDA-24238 CHAPTER 3 Page 69 Revision 3.0 SYSTEM MESSAGES This message displays when a C-level program abnormal state is detected as permanent. When the Port Mi- croprocessor (PM) on an LC/TRK card detects the abnormal state, the PM places the card into make-busy sta- tus. If the failure occurs more than 15 times an hour, the system judges the failure as permanent and issues the this system message. ➀Faulty Circuit Card Mounting Location 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: MN3-BC-Level Infinite Loop (Permanent)Default Grade: 3Grade Modified: Lamp Modified: b0-b4: Group b5-b6: Unit (0-3) b7: Module Group (0/1)
CHAPTER 3 NDA-24238 Pag e 7 0 Revision 3.0 SYSTEM MESSAGES This message displays when C-level program is detected as abnormal by the Port Microprocessor (PM) mount- ed on an LC/TRK card. If the failure occurs less than 15 times/hour, and a B-monitor/Initial restart executes as the result, the failure is judged as temporary and this message is created. ➀Faulty Circuit Card Mounting Location ➁ PM Restart Type Note:B-monitor Restart: Ports whose link has already been established remain connected. Ports processing a call-origination may be released. Initial Restart: All ports on the circuit card are forcibly released to be placed in idle state. 1: XX0X 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b0 Default Alarm: SUP3-CC-Level Infinite Loop (Temporary)Default Grade: 1Grade Modified: Lamp Modified: b0-b4: Group b5-b6: Unit (0-3) b7: Module Group (0/1) b0: 0/1 = B-monitor/Initial Restart Note
NDA-24238 CHAPTER 3 Page 71 Revision 3.0 SYSTEM MESSAGES At the periodic interval, the CPU sends diagnosis data to the Port Microprocessor (PM) on LC/TRK cards in order to monitor the PM. If the CPU cannot receive the return data within a predetermined period of time, the system displays this data. When the failure is detected more than 15 times per hour, the failure is judged as permanent. ➀ Faulty Circuit Card Location Reference: See Chapter 5, Section 6.2, for the repair procedure. 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: MN3-DLock-Up Failure (Permanent)Default Grade: 3Grade Modified: Lamp Modified: b0-b4: Group b5-b6: Unit (0-3) b7: Module Group 0/1 = Even-numbered MG/Odd-numbered MG
CHAPTER 3 NDA-24238 Pag e 7 2 Revision 3.0 SYSTEM MESSAGES At the periodic interval, the CPU sends diagnosis data to the Port Microprocessor (PM) on LC/TRK cards in order to monitor the PM. If the CPU cannot receive the return data within a predetermined period of time, the system displays this data. When the failure is detected less than 15 times per hour, the failure is judged as tem- porary. ➀ Faulty Circuit Card Location ➁ PM Restart Type 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b0 Default Alarm: SUP3-ELock-Up Failure (Temporary)Default Grade: 1Grade Modified: Lamp Modified: b0-b4: Group b5-b6: Unit (0-3) b7: Module Group 0/1 = Even-numbered MG/Odd-numbered MG b0: 0/1 = B-monitor/Initial Restart
NDA-24238 CHAPTER 3 Page 73 Revision 3.0 SYSTEM MESSAGES This message displays when over current of the operating power (DC-48V) is supplied from the ATI/ELC cir- cuit card to the Attendant Console/Dterm. When this fault occurs, the related circuit card is placed into make- busy state and stops supplying power. ➀ Location of faulty PM 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: SUP3-F-48V Over CurrentDefault Grade: 3Grade Modified: Lamp Modified: b0-b4: Group b5, b6: Unit b7: 0/1 = Even-numbered MG/Odd-numbered MG