    							CHAPTER 3 NDA-24238
    Pag e 6 4
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the changeover of the TSW system is executed.
    ➀ACT side Speech Path (TSW) after 
    changeover
    ➁ Reason for changeover
    1: XXXX 0000 XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 XXXX XXXX
    ➀  ➁ ➂  ➃ ➄  ➅ ➆  ➇ ➈  ➉
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON1-TTSW ACT Change ReportDefault Grade:
    2Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system/No. 1 system
    b7-b4b3-b0CardContents
    01TSWI/O Alarm
    2 32ch Clock down, FH down
    3 24ch Clock down, FH down
    6 TSW SW Memory write failure
    9 I/O Alarm release
    10 32ch Clock down recovered,
    FH down recovered
    11 24ch Clock down recovered,
    FH down recovered
    13 TSW MBR key OFF
    15 TSW ACT/STBY changeover by CMOD 
    command
    6 1 MUX MUX circuit card Ready failure
    2 MUX circuit card clock failure 
    						
    							NDA-24238 CHAPTER 3
    Page 65
    Revision 3.0
    SYSTEM MESSAGES
    ➂~➅ Status of ACT side TSW card
    ➆~➉ Status of ST-BY side TSW card
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b0-b3, b4-b7: The status of TSW card in each MG (00~07)
    0000 = Normal
    0001 = Abnormal (Impossible to make links)
    ➂MG00 MG01
    ➃MG02 MG03
    ➄MG04 MG05
    ➅MG06 MG07
    b7-b4 b3-b0
    b0-b3, b4-b7: The status of TSW card in each MG (00~07)
    0000 = Normal
    0001 = Abnormal (Impossible to make links)
    ➆MG00 MG01
    ➇MG02 MG03
    ➈MG04 MG05
    ➉MG06 MG07
    b7-b4 b3-b0 
    						
    							CHAPTER 3 NDA-24238
    Pag e 6 6
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when DLKC data transfer failure (temporary), shown in message [1-V], occurs more
    than 16 times an hour. At this time, the faulty DLKC card is down and its switching network automatically
    changes over.
    ➀ System status of faulty DLKC card
    ➁ Error Code
    ➂ Details on Switching Network
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b1 b0
    Default Alarm:
    MN1-UDLKC Data Transfer Failure (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system / No. 1 system
    01H: Firmware fault
    02H: Data transfer time out to DLKC
    03H: No answer time out (at DLKC)
    04H: Data parity error
    b0: Status of Speech Path System (including DLKC)
    0/1 = No. 0 system is ACT/No. 1 system is ACT
    b1: Status of basic clock
    0/1 = No. 0 system is ACT/No. 1 system is ACT 
    						
    							NDA-24238 CHAPTER 3
    Page 67
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a data sending error or no answer error occurs at the time of data transfer from
    CPU to DLKC card.
    ➀ System status of faulty DLKC card
    ➁ Error Code
    ➂ Details on Switching Network
    Note:This data displays when the STBY DLKC card is detected as faulty.
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b1 b0
    Default Alarm:
    SUP1-VDLKC Data Transfer Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0 system / No. 1 system
    01H: Firmware fault
    02H: Data transfer time out to DLKC
    03H: No answer time out (at DLKC)
    04H: Data parity error
    b0: Status of Speech Path System (including DLKC)
    0/1 = No. 0 system is ACT/No. 1 system is ACT
    b1: Status of basic clock
    0/1 = No. 0 system is ACT/No. 1 system is ACT
    b7: Information on Reset of STBY DLKC  Note
    0/1 = - /STBY DLKC card was reset 
    						
    							CHAPTER 3 NDA-24238
    Pag e 6 8
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a failure such as internal clock down occurred to PLO is restored.
    ➀ Restoration of PLO fault
    ➁ Current Status of PLO card
    ➂ Current Status of PLO card
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b4 b1 b0
    Default Alarm:
    NON1-WPLO RestoreDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = PLO No. 0 system/PLO No. 1 system
    b0: 0/1 = Clock is in STBY side/ACT side
    b1: 0/1 = PLO synchronizing/PLO self running or drifting
    b2: 0/1 = -/Input clock down
    b3, b4: Route of input clock (see the table below)
    b5: 0/1 = -/PLO input all down
    b6: 0/1 = -/PLO output down
    b7: 0/1 = -/Drifting
    b4b3Connected With Primary 
    Oscillator (M-OSC)Connected With 
    External Clock
    0 0 No. 0 M-OSC Route 0
    0 1 No. 1 M-OSC Route 1
    10 – Route 2
    –Route 3
    b0: 0/1 = -/5msec clock down
    b1: 0/1 = -/Frame Synchronization from SYNC card is down
    b4: 0/1 = -/Internal OSC clock down 
    						
    							NDA-24238 CHAPTER 3
    Page 69
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a C-level program abnormal state is detected as permanent. When the Port Mi-
    croprocessor (PM) on an LC/TRK card detects the abnormal state, the PM places the card into make-busy sta-
    tus. If the failure occurs more than 15 times an hour, the system judges the failure as permanent and issues the
    this system message.
    ➀Faulty Circuit Card Mounting 
    Location
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀
     
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    MN3-BC-Level Infinite Loop (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group
    b5-b6: Unit (0-3)
    b7: Module Group (0/1) 
    						
    							CHAPTER 3 NDA-24238
    Pag e 7 0
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when C-level program is detected as abnormal by the Port Microprocessor (PM) mount-
    ed on an LC/TRK card. If the failure occurs less than 15 times/hour, and a B-monitor/Initial restart executes
    as the result, the failure is judged as temporary and this message is created.
    ➀Faulty Circuit Card Mounting 
    Location
    ➁ PM Restart Type
    Note:B-monitor Restart: Ports whose link has already been established remain connected. Ports processing
    a call-origination may be released.
    Initial Restart: All ports on the circuit card are forcibly released to be placed in idle state.
    1: XX0X 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b0
    Default Alarm:
    SUP3-CC-Level Infinite Loop (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group 
    b5-b6: Unit (0-3)
    b7: Module Group (0/1)
    b0: 0/1 = B-monitor/Initial Restart     Note 
    						
    							NDA-24238 CHAPTER 3
    Page 71
    Revision 3.0
    SYSTEM MESSAGES
    At the periodic interval, the CPU sends diagnosis data to the Port Microprocessor (PM) on LC/TRK cards in
    order to monitor the PM. If the CPU cannot receive the return data within a predetermined period of time, the
    system displays this data. When the failure is detected more than 15 times per hour, the failure is judged as
    permanent.
    ➀ Faulty Circuit Card Location
    Reference: See Chapter 5, Section 6.2, for the repair procedure.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    MN3-DLock-Up Failure (Permanent)Default Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group
    b5-b6: Unit (0-3)
    b7: Module Group
    0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24238
    Pag e 7 2
    Revision 3.0
    SYSTEM MESSAGES
    At the periodic interval, the CPU sends diagnosis data to the Port Microprocessor (PM) on LC/TRK cards in
    order to monitor the PM. If the CPU cannot receive the return data within a predetermined period of time, the
    system displays this data. When the failure is detected less than 15 times per hour, the failure is judged as tem-
    porary.
    ➀ Faulty Circuit Card Location
    ➁ PM Restart Type
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b0
    Default Alarm:
    SUP3-ELock-Up Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group 
    b5-b6: Unit (0-3)
    b7: Module Group
    0/1 = Even-numbered MG/Odd-numbered MG
    b0: 0/1 = B-monitor/Initial Restart 
    						
    							NDA-24238 CHAPTER 3
    Page 73
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when over current of the operating power (DC-48V) is supplied from the ATI/ELC cir-
    cuit card to the Attendant Console/Dterm. When this fault occurs, the related circuit card is placed into make-
    busy state and stops supplying power.
    ➀ Location of faulty PM
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP3-F-48V Over CurrentDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group
    b5, b6: Unit
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						