    							CHAPTER 3 NDA-24238
    Page 204
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MBR switch on the CCH/DCH card is turned OFF.
    ➀ Location of CCH/DCH card
    ➁ CKT No.
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b1 b0
    Default Alarm:
    NON17-BCCH MBR Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG
    b0, b1: CKT No. (0-3) 
    						
    							NDA-24238 CHAPTER 3
    Page 205
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MB switch on the CCH/DCH card is turned ON while extracting or inserting
    a circuit card or at PM initialization, etc.
    ➀ Location of CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON17-CCCH MB Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24238
    Page 206
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MB switch on the CCH/DCH card is turned OFF while extracting or inserting
    a circuit card or at PM initialization, etc.
    ➀ Location of CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON17-DCCH MB Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24238 CHAPTER 3
    Page 207
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the NIGHT switch on the ATTCON/DESKCON is operated or when the DAY/
    NIGHT change is executed by the external switch operation.
    ➀ Tenant No.
    ➁ Changing Method
    1: XXXX XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON17-HDay/Night Change InformationDefault Grade:
    0Grade Modified: Lamp Modified:
    b0-b3: Tenant No. (1-15)
    b4-b7: Tenant No. (over 15)
    b0-b7:
    1=Night Key on ATTCON/DESKCON
    2=External Key 
    						
    							CHAPTER 3 NDA-24238
    Page 208
    Revision 3.0
    SYSTEM MESSAGES
    ➂ Day/Night Mode Specification
    ➃ External Switch Status b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b0-b3:  Mode after changing
    b4-b7:  Mode before changing
    Note:
    This data is programmed as initial data.
    b0b1b2b3
    MEANING
    b4b5b6b7
    0000Day Mode
    0001Night Mode 1
    0010Night Mode 2 available only for Japan
    0 0 1 1 Night Mode 3 (DIT-Night Connection Fixed) Note
    b0-b7:
    01=Not used
    02=Day/Night Change
    03=Not used 
    						
    							NDA-24238 CHAPTER 3
    Page 209
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MB switch on the IOC card is turned ON while extracting or inserting a circuit
    card.
    ➀ Circuit Card No.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    Default Alarm:
    NON17-OIOC MB Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = IOC 0/IOC 1 
    						
    							CHAPTER 3 NDA-24238
    Page 210
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MB switch on the IOC card is turned OFF.
    ➀ Circuit Card No.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    Default Alarm:
    NON17-PIOC MB Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = IOC 0/IOC 1 
    						
    							NDA-24238 CHAPTER 3
    Page 211
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MBR switch on the IOC card is turned on at the time of CPU changeover or
    speech path changeover.
    ➀ Circuit Card No.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    Default Alarm:
    NON17-QIOC MBR Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = IOC 0/IOC 1 
    						
    							CHAPTER 3 NDA-24238
    Page 212
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MBR switch on the IOC card is turned off at the time of CPU changeover or
    speech path changeover.
    ➀ Circuit Card No.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    Default Alarm:
    NON17-RIOC MBR Key Turn OFFDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = IOC 0/IOC 1 
    						
    							NDA-24238 CHAPTER 3
    Page 213
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the Primary Dch fails, and the Dch Back-Up function is operated automatically.
    ➀ Condition of Dch
    ➁ Location of Dch (Primary)
    ➂ Location of Dch (Back-up)
    1: XXXX XXXX XXXX 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON23-PDCH Back-Up Automatic Change Start/EndDefault Grade:
    1Grade Modified: Lamp Modified:
    b0-b7:
    1 = Back-up Start
    2 = Back-up End
    3 = Back-up Failed
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						