CHAPTER 6 NDA-24238 Page 434 Revision 3.0 SYSTEM OPERATIONS 9.3 Office Data Management Procedure The procedure generally taken when changing the office data is shown below. If your system uses software Release 1 or 2, refer to Figure 6-25. If the software is Release 3 or later, refer to Figure 6-26. For systems using software Release 1 or 2 Figure 6-25 Office Data Change Procedure (for Release 1 or 2) HDD_MAT command Note Direction Select : Verify HDD against MAT Data Type Select : Data Memory, etc. MEM_HDD command Note Direction Select : Verify HDD against MEM Data Type Select : Data Memory, etc. Entry Into Office Data Programming Sheets MEM_HDD command Note Direction Select : Memory to Hard Disk Data Type Select : Data Memory, etc. Entry Into Office Data Programming Sheets Entry Into Office Data Programming Sheets HDD_MAT command Note Direction Select : PBX Hard Disk to MAT Data Type Select : Data Memory, etc. CREATION OF DATA CHANGE PLAN DATA CHANGING DATA SAVE FROM HDD INTO FD DATA VERIFY DATA VERIFY DATA SAVE FROM MEM INTO HDD LISTING OFFICE DATA Note:Refer to Figure 6-29 for each command function.
NDA-24238 CHAPTER 6 Page 435 Revision 3.0 SYSTEM OPERATIONS For systems using software Release 3 or Later Figure 6-26 Office Data Change Procedure (for Release 3 or Later) HDD_FDD command Note System Select : HFD0/HFD1 Direction Select : Verify HDD against FDD Data Type Select : Data Memory, etc. MEM_HDD command Note Direction Select : Verify HDD against MEM Data Type Select : Data Memory, etc. Entry Into Office Data Programming Sheets MEM_HDD command Note Direction Select : Memory to Hard Disk Data Type Select : Data Memory, etc. Entry Into Office Data Programming Sheets Entry Into Office Data Programming Sheets HDD_FDD command Note System Select : HFD0/HFD1 Direction Select : Hard Disk to Floppy Disk Data Type Select : Data Memory, etc. CREATION OF DATA CHANGE PLAN DATA CHANGING DATA SAVING FROM HDD INTO FD DATA VERIFICATION DATA VERIFICATION DATA SAVING FROM MEM INTO HDD LISTING OFFICE DATA Note:Refer to Figure 6-27 for each command function.
CHAPTER 6 NDA-24238 Page 436 Revision 3.0 SYSTEM OPERATIONS Figure 6-27 shows the function of three backup commands: HDD to FDD, HDD to MAT, and MEM to HDD. Figure 6-27 Backup Commands NECNEAX 2400 IMS MAT HDD FD FDDFDDMEMPBX HDD_FDD DM: Data Memory NDM: Network Data Memory LDM: Local Data Memory ND: Name Display Data RCF: Wireless Call Forwarding Data CF: Call Forwarding Data SPD: Speed Calling-System Data USK: User Assign Soft Key Data (for Release 3 or later) NS: Number Sharing Data (for Release 3 or later) Note CBK: Call Block Data (for Release 5 or later) : Command MEM_HDD HDD_MATDM NDM LDM ND RCF CF SPD USK NS CBKDM NDM LDM ND RCF CF SPD USK NS CBK DM NDM LDM ND RCF CF SPD USK NS CBK HDDFD MEM_HDD HDD_FDD HDD_MAT Note:Number Sharing data load/backup also affects the data load/backup of Dual Station Calling Over-FCCS.
NDA-24238 CHAPTER 6 Page 437 Revision 3.0 SYSTEM OPERATIONS 9.4 Call Forwarding Data/Individual Speed Calling Data Management Call Forwarding Data and Individual Speed Calling Data are changed at any time because these services are set/cancelled from the station involved. In the PBX, these data are backed up by FD. Call Forwarding Data: HDD_MAT command Individual Speed Calling Data: HDD_MAT command 9.5 One-Touch Speed Call Memory Data Management One-Touch Speed Call Memory data of D term is destroyed when DLC/ELC circuit card has been replaced with a spare or its mounting slot has been changed. The data can be backed up onto FD before replacement or mounting slot change of DLC/ELC card. Backup: BOSD command 9.6 Data Management Commands COMMAND COMMAND FULL NAME BOSDOne-Touch Speed Call Memory Data Backup HDD_FDDData Control Between HDD and FDD HDD_MATData Control Between HDD and MAT MEM_HDDData Control Between Memory and HDD
CHAPTER 6 NDA-24238 Page 438 Revision 3.0 SYSTEM OPERATIONS 10. TEST OPERATIONS OF VARIOUS KINDS This section explains the methods of test operations (shown in Figure 6-28) to be performed in case a fault recovery occurs. Figure 6-28 Test Operation Method Examples COMMAND COMMAND FULL NAME DCON Display of Connection Status Display of connection status of designated station/trunk Test connection by designating trunks, tones, and ringback tone from test station 10.1 Designated Connection Test (Station) Test connection by designating trunks (outgoing only) from Attendant/Desk Console 10.2 Designated Connection Test (ATTCON/DESKCON) Display of line failure indication when faulty condition occurred while a call is in progress 10.3 Bad Call Notification
NDA-24238 CHAPTER 6 Page 439 Revision 3.0 SYSTEM OPERATIONS 10.1 Designated Connection Test (Station) (1) General The purpose of this test is to confirm the operations related to a trunk or tone that is designated from the test station. Refer to Ta b l e 6 - 6. The test result displays on the MAT screen as system message [6-I]. (2) Precaution Designated connection to a trunk—A designated connection to trunk is limited only to an individual line of either 2nd DT system or sender system. Table 6-6 Designated Connection Test (Station) Operations ITEM TEST ITEM CONTENT OF CONFIRMATION REMARKS 1 Register (ORT/IRT) Whether the dialed numbers (1, 2, 3, 4, 5, 6, 7, 8, 9, 0, *, #) can be received correctly is to be confirmed. 2 Sender Whether the numbers (1, 2, 3, 4, 5, 6, 7, 8, 9, 0, *, #) can all be sent out is to be confirmed. 3 3-Party Conference TrunkBy connecting the test tone to each port of a 3-Party Conference Trunk, whether the test tone can be heard is to be confirmed. 4 Tone Various kinds of tone are to be confirmed. 5 Interrupted Ringing (IR)Interrupt ringing (IR) is to be confirmed. 6 Trunk Connections of trunks are to be confirmed.
CHAPTER 6 NDA-24238 Page 440 Revision 3.0 SYSTEM OPERATIONS (3) Designated Connection Test Procedure (a) Register Test Procedure Figure 6-29 Register Test Procedure/Connection Diagram Access code is assigned by ASPA command, CI=N, SRV=SSC, SID=17 Route numbers to be designated are as follows.: If any of the dialed numbers are not received correctly, a Reorder Tone (ROT) is heard. RT NUMBER 902 903 TRUNK NAME Originating Register Trunk Incoming Register Trunk Hang Up TRUNK DESIGNATIONTEST IN PROGRESS REGISTER UNDER TEST ORT Note: If the trunk number of the next register is not assigned, the test ends. Lift handset (DT) Dial access code for designated connection “9xx + “xxx” RT No. TRK No. (DT) Dial “1,2,3,4,5,6,7,8,9,0” (*, # in case of PB signal) consecutively (SST) Is next register to be tested, too?(NO) (YES) Make switch hook flash Note
NDA-24238 CHAPTER 6 Page 441 Revision 3.0 SYSTEM OPERATIONS (b) Sender Test Procedure Figure 6-30 Sender Test Procedure/Connection Diagram Access code is assigned by ASPA command, CI=N, SRV=SSC, SID=17 Route number to be designated is as follows: If any of the dialed numbers are received correctly, a Reorder Tone (ROT) is heard. RT NUMBER 905 TRUNK NAME Sender Trunk DP/PB Hang Up Note 1: After the sender to be tested is connected to the register, the sender sends out 1 ~ 9, 0 by DP signals and 1 ~ 9, 0, *, # by PB signals, thus checking to see if the dialed numbers are sent out correctly. Note 2:If the trunk number of the next sender is not assigned, the test ends. + “9xx” RT No.“xxx” TRK No. Lift handset Connection test is automatically Is next performed Note 1 register to be tested, too? Make switch hook flash Note 2 (DT) Dial access code for designated connection (Music On Hold) (SST) TRUNK DESIGNATION MUSIC ON HOLD ORT SNDTEST IN PROGRESS ORT DP OR PB YESNO
CHAPTER 6 NDA-24238 Page 442 Revision 3.0 SYSTEM OPERATIONS (c) 3-Party Conference Trunk Test Procedure Figure 6-31 3-Party Conference Test Procedure Note:If the trunk number of the next 3-Party Conference Trunk is not assigned, the test ends. Access code is assigned by ASPA command, CI=N, SRV=SSC, SID=17 Route numbers to be designated are as follows: RT NUMBER 909 913 TRUNK NAME 3-party conference trunk (for station, ATTCON, trunk) 3-party conference trunk (only for ATTCON) + “9xx” RT No.“xxx” TRK No. Lift handset Is next register to be tested, too? Make switch hook flash Note (DT) Dial access code for designated connection (SST) (SST) YESNO Hang Up As shown in Figure 6-32, tone sending is repeated.
NDA-24238 CHAPTER 6 Page 443 Revision 3.0 SYSTEM OPERATIONS Figure 6-32 3-Party Conference Test Connection Diagram TSTT TSTT TSTTTSTT TSTT TSTT ORTSST TRUNK DESIGNATION TEST IN PROGRESS 1 SEC.1 SEC.1 SEC.1 SEC. 1 SEC. 1 SEC. 1 SEC. 1 SEC. (DT) (SST) (DT) (SST) (DT) (SST)