Home > NEC > Communications System > NEC Neax 2400 Imx System Operations And Maintenance Manual

NEC Neax 2400 Imx System Operations And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Imx System Operations And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 647
    							CHAPTER 6 NDA-24238
    Page 434
    Revision 3.0
    SYSTEM OPERATIONS
    9.3 Office Data Management Procedure
    The procedure generally taken when changing the office data is shown below. If your system uses software
    Release 1 or 2, refer to Figure 6-25. If the software is Release 3 or later, refer to Figure 6-26.
    For systems using software Release 1 or 2
    Figure 6-25   Office Data Change Procedure (for Release 1 or 2)
    HDD_MAT command Note
    Direction Select : Verify HDD against MAT
    Data Type Select : Data Memory, etc.
    MEM_HDD command Note
    Direction Select : Verify HDD against MEM
    Data Type Select : Data Memory, etc. Entry Into Office Data Programming Sheets
    MEM_HDD command Note
    Direction Select : Memory to Hard Disk
    Data Type Select : Data Memory, etc. Entry Into Office Data Programming Sheets
    Entry Into Office Data Programming Sheets
    HDD_MAT command Note
    Direction Select : PBX Hard Disk to MAT
    Data Type Select : Data Memory, etc.
    CREATION OF DATA CHANGE PLAN
    DATA CHANGING
    DATA SAVE FROM HDD INTO FD
    DATA VERIFY
    DATA VERIFY
    DATA SAVE FROM MEM INTO HDD
    LISTING OFFICE DATA
    Note:Refer to Figure 6-29 for each command function. 
    						
    							NDA-24238 CHAPTER 6
    Page 435
    Revision 3.0
    SYSTEM OPERATIONS
    For systems using software Release 3 or Later
    Figure 6-26   Office Data Change Procedure (for Release 3 or Later)
    HDD_FDD command Note
    System Select : HFD0/HFD1
    Direction Select : Verify HDD against FDD
    Data Type Select : Data Memory, etc.
    MEM_HDD command Note
    Direction Select : Verify HDD against MEM
    Data Type Select : Data Memory, etc. Entry Into Office Data Programming Sheets
    MEM_HDD command Note
    Direction Select : Memory to Hard Disk
    Data Type Select : Data Memory, etc. Entry Into Office Data Programming Sheets
    Entry Into Office Data Programming Sheets
    HDD_FDD command Note
    System Select : HFD0/HFD1
    Direction Select : Hard Disk to Floppy Disk
    Data Type Select : Data Memory, etc.
    CREATION OF DATA CHANGE PLAN
    DATA CHANGING
    DATA SAVING FROM HDD INTO FD
    DATA VERIFICATION
    DATA VERIFICATION
    DATA SAVING FROM MEM INTO HDD
    LISTING OFFICE DATA
    Note:Refer to Figure 6-27 for each command function. 
    						
    							CHAPTER 6 NDA-24238
    Page 436
    Revision 3.0
    SYSTEM OPERATIONS
    Figure 6-27 shows the function of three backup commands: HDD to FDD, HDD to MAT, and MEM to
    HDD.
    Figure 6-27   Backup Commands
    NECNEAX 2400 IMS
    MAT
    HDD
    FD FDDFDDMEMPBX
    HDD_FDD
    DM:	Data Memory
    NDM:	Network Data Memory
    LDM: 	Local Data Memory
    ND: 	Name Display Data
    RCF:	Wireless Call Forwarding Data
    CF:	Call Forwarding Data
    SPD:	Speed Calling-System Data
    USK:	User Assign Soft Key Data  (for Release 3 or later)
    NS:	Number Sharing Data  (for Release 3 or later)  Note
    CBK:	Call Block Data  (for Release 5 or later)
               :	Command
    
    MEM_HDD
    HDD_MATDM
    NDM
    LDM
    ND
    RCF
    CF
    SPD
    USK
    NS
    CBKDM
    NDM
    LDM
    ND
    RCF
    CF
    SPD
    USK
    NS
    CBK
    DM
    NDM
    LDM
    ND
    RCF
    CF
    SPD
    USK
    NS
    CBK
    HDDFD
    MEM_HDD
    HDD_FDD HDD_MAT
    Note:Number Sharing data load/backup also affects the data load/backup of Dual Station Calling
    Over-FCCS. 
    						
    							NDA-24238 CHAPTER 6
    Page 437
    Revision 3.0
    SYSTEM OPERATIONS
    9.4 Call Forwarding Data/Individual Speed Calling Data Management
    Call Forwarding Data and Individual Speed Calling Data are changed at any time because these services
    are set/cancelled from the station involved. In the PBX, these data are backed up by FD.
    Call Forwarding Data:  HDD_MAT command
    Individual Speed Calling Data: HDD_MAT command
    9.5 One-Touch Speed Call Memory Data Management
    One-Touch Speed Call Memory data of D
    term is destroyed when DLC/ELC circuit card has been replaced
    with a spare or its mounting slot has been changed. The data can be backed up onto FD before replacement
    or mounting slot change of DLC/ELC card.
    Backup: BOSD command
    9.6 Data Management Commands
    COMMAND COMMAND FULL NAME
    BOSDOne-Touch Speed Call Memory Data Backup
    HDD_FDDData Control Between HDD and FDD
    HDD_MATData Control Between HDD and MAT
    MEM_HDDData Control Between Memory and HDD 
    						
    							CHAPTER 6 NDA-24238
    Page 438
    Revision 3.0
    SYSTEM OPERATIONS
    10. TEST OPERATIONS OF VARIOUS KINDS
    This section explains the methods of test operations (shown in Figure 6-28) to be performed in case a fault
    recovery occurs.
    Figure 6-28   Test Operation Method Examples
    COMMAND COMMAND FULL NAME
    DCON Display of Connection Status Display of connection status of designated station/trunk
    Test connection by designating trunks, tones, and ringback tone from test station
    10.1  Designated Connection Test (Station)
    Test connection by designating trunks (outgoing only) from Attendant/Desk Console
    10.2  Designated Connection Test (ATTCON/DESKCON)
    Display of line failure indication when faulty condition occurred while a call is in progress
    10.3  Bad Call Notification 
    						
    							NDA-24238 CHAPTER 6
    Page 439
    Revision 3.0
    SYSTEM OPERATIONS
    10.1 Designated Connection Test (Station)
    (1) General
    The purpose of this test is to confirm the operations related to a trunk or tone that is designated from the
    test station. Refer to Ta b l e  6 - 6. The test result displays on the MAT screen as system message [6-I].
    (2) Precaution
    Designated connection to a trunk—A designated connection to trunk is limited only to an individual line
    of either 2nd DT system or sender system.
    Table 6-6  Designated Connection Test (Station) Operations
    ITEM TEST ITEM CONTENT OF CONFIRMATION REMARKS
    1 Register (ORT/IRT) Whether the dialed numbers (1, 2, 3, 4, 5, 6, 7, 8, 9, 0, *, #) can be 
    received correctly is to be confirmed.
    2 Sender Whether the numbers (1, 2, 3, 4, 5, 6, 7, 8, 9, 0, *, #) can all be sent out 
    is to be confirmed.
    3 3-Party Conference 
    TrunkBy connecting the test tone to each port of a 3-Party Conference Trunk, 
    whether the test tone can be heard is to be confirmed.
    4 Tone Various kinds of tone are to be confirmed.
    5 Interrupted Ringing 
    (IR)Interrupt ringing (IR) is to be confirmed.
    6 Trunk Connections of trunks are to be confirmed. 
    						
    							CHAPTER 6 NDA-24238
    Page 440
    Revision 3.0
    SYSTEM OPERATIONS
    (3) Designated Connection Test Procedure
    (a) Register Test Procedure
    Figure 6-29   Register Test Procedure/Connection Diagram
     Access code is assigned by ASPA command, CI=N,
    SRV=SSC, SID=17
     Route numbers to be designated are as follows.:
     If any of the dialed numbers are not received correctly, a
    Reorder Tone (ROT) is heard.
    RT NUMBER
    902
    903
    TRUNK NAME
    Originating Register Trunk
    Incoming Register Trunk
    Hang Up
    TRUNK DESIGNATIONTEST IN PROGRESS
    REGISTER
    UNDER TEST
    ORT
    Note: If the trunk number of the next register is not assigned, the test ends.
    Lift handset
    (DT)
    Dial access code for 
    designated connection
    “9xx + “xxx”
    RT No. TRK No.
    (DT)
    Dial “1,2,3,4,5,6,7,8,9,0” (*, # 
    in case of PB signal) 
    consecutively
    (SST)
    Is next register to 
    be tested, too?(NO)
    (YES)
    Make switch hook flash 
    Note 
    						
    							NDA-24238 CHAPTER 6
    Page 441
    Revision 3.0
    SYSTEM OPERATIONS
    (b) Sender Test Procedure
    Figure 6-30   Sender Test Procedure/Connection Diagram
     Access code is assigned by ASPA command, CI=N,
    SRV=SSC, SID=17
     Route number to be designated is as follows:
     If any of the dialed numbers are received correctly, a Reorder
    Tone (ROT) is heard.
    RT NUMBER
    905
    TRUNK NAME
    Sender Trunk DP/PB
    Hang Up
    Note 1:
    After the sender to be tested is connected to the register, the sender sends out 1 ~ 9, 0 by DP
    signals and 1 ~ 9, 0, *, # by PB signals, thus checking to see if the dialed numbers are sent out
    correctly.
    Note 2:If the trunk number of the next sender is not assigned, the test ends.
    + “9xx”
    RT No.“xxx”
    TRK No. Lift handset
    Connection test is automatically
    Is next
    performed Note 1
    register to be
    tested, too?
    Make switch hook flash
    Note 2
    (DT)
    Dial access code for
    designated connection
    (Music On Hold)
    (SST)
    TRUNK DESIGNATION
    MUSIC ON
    HOLD
    ORT
    SNDTEST IN PROGRESS
    ORT
    DP
    OR PB
    YESNO 
    						
    							CHAPTER 6 NDA-24238
    Page 442
    Revision 3.0
    SYSTEM OPERATIONS
    (c) 3-Party Conference Trunk Test Procedure
    Figure 6-31   3-Party Conference Test Procedure
    Note:If the trunk number of the next 3-Party Conference Trunk is not assigned, the test ends.
     Access code is assigned by ASPA command, CI=N,
    SRV=SSC, SID=17
      Route numbers to be designated are as follows:
    RT NUMBER
    909
    913
    TRUNK NAME
    3-party conference trunk
    (for station, ATTCON, trunk)
    3-party conference trunk
    (only for ATTCON)
    + “9xx”
    RT No.“xxx”
    TRK No. Lift handset
    Is next
    register to be
    tested, too?
    Make switch hook flash
    Note
    (DT)
    Dial access code for
    designated connection
    (SST)
    (SST)
    YESNO
    Hang Up As shown in Figure 6-32, 
    tone sending is repeated. 
    						
    							NDA-24238 CHAPTER 6
    Page 443
    Revision 3.0
    SYSTEM OPERATIONS
    Figure 6-32   3-Party Conference Test Connection Diagram
    TSTT TSTT TSTTTSTT TSTT TSTT ORTSST TRUNK DESIGNATION TEST IN PROGRESS
    1 SEC.1 SEC.1 SEC.1 SEC.
    1 SEC.
    1 SEC.
    1 SEC. 1 SEC.
    (DT) (SST) (DT)
    (SST) (DT) (SST) 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2400 Imx System Operations And Maintenance Manual