CHAPTER 3 NDA-24238 Page 194 Revision 3.0 SYSTEM MESSAGES This message displays when the DR signal of the RS-232C, connected to the port designated by the system data, remains off for 30 consecutive seconds while the system is in service (immediately after startup in the case of system start-up). ➀ Faulty Port No. 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON16-KI/O Port Line OFFDefault Grade: 1Grade Modified: Lamp Modified: 0/1 = -/Link Down b0: Port 0 b4: Port 4 b1: Port 1 b5: Port 5 b2: Port 2 b6: Port 6 b3: Port 3 b7: Port 7 IOC0IOC1
NDA-24238 CHAPTER 3 Page 195 Revision 3.0 SYSTEM MESSAGES This message displays when [16-K] I/O Port Line Down Failure is restored to normal. ➀ Faulty Port No. 1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 Default Alarm: NON16-LI/O Port Line RestoreDefault Grade: 1Grade Modified: Lamp Modified: 0/1 = -/Link Down b0: Port 0 b4: Port 4 b1: Port 1 b5: Port 5 b2: Port 2 b6: Port 6 b3: Port 3 b7: Port 7 IOC0IOC1
CHAPTER 3 NDA-24238 Page 196 Revision 3.0 SYSTEM MESSAGES This message displays when the timer circuit in the EMA card becomes faulty and stops functioning and 64- Hz clock alarm is output. ➀ Message Detail Data This system message is always indicated as 0000. 1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 Default Alarm: SUP16-MHard Clock FailureDefault Grade: 3Grade Modified: Lamp Modified:
NDA-24238 CHAPTER 3 Page 197 Revision 3.0 SYSTEM MESSAGES This message displays when [16-M] 64 Hz Clock Down Detected is restored to normal. ➀ Message Detail Data This system message is always indicated as 0000. 1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 Default Alarm: NON16-NHard Clock RestoreDefault Grade: 3Grade Modified: Lamp Modified:
CHAPTER 3 NDA-24238 Page 198 Revision 3.0 SYSTEM MESSAGES This message displays when the IOC card fails. ➀ IOC circuit card No. ➁ Cause for fault 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 b7 b4 b3 b2 b1 b0 Default Alarm: SUP16-TIOC Failure (Temporary)Default Grade: 1Grade Modified: Lamp Modified: b0: 0/1 = No. 0/No. 1 b0: 0/1 = -/COP Alarm b1: 0/1 = -/CLK Alarm b2: 0/1 = -/MEM bus CLK Alarm b3: 0/1 = -/Abnormal Interruption b4: 0/1 = -/Infinite Loop Detected
NDA-24238 CHAPTER 3 Page 199 Revision 3.0 SYSTEM MESSAGES This message displays when the IOC card failure, observed in the message [16-T], is detected more than 8 times a day. ➀ IOC circuit card No. ➁ Cause for fault Reference: See Chapter 4, Section 1.3.3, for the circuit card replacement procedure. 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b0 b7 b4 b3 b2 b1 b0 Default Alarm: SUP16-UIOC Failure (Permanent)Default Grade: 2Grade Modified: Lamp Modified: b0: 0/1 = No. 0/No. 1 b0: 0/1 = -/COP Alarm b1: 0/1 = -/CLK Alarm b2: 0/1 = -/MEM bus CLK Alarm b3: 0/1 = -/Abnormal Interruption b4: 0/1 = -/Infinite Loop Detected
CHAPTER 3 NDA-24238 Page 200 Revision 3.0 SYSTEM MESSAGES This message displays when the user uses Follow Phone (SWAP) service. ➀ Error code 1: XXXX XXXX XXXX XX00 2: XXXX XXXX XXXX 00XX 3: XXXX 0000 0000 0000 ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉ 1112 13 14 14 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 ERROR CODE (HEX)FAILURE 00 Normal End 01 MG unmatch 02 Called party is not the station 03 TEC of Calling or Called station is abnormal 04 TEC unmatch 05 Hunting group unmatch 06 Call Pick Up group unmatch 07 Calling or Called station is Night station 08 Call Pick Up Expand group unmatch 09 - 10 Calling or Called D term has Data Line 11 Calling or Called D term has OAI function key 12 Calling or Called station is Agent/Supervisor (ACD) 13-15 - 16 Called station is busy 17 MW has been set to Calling or Called station Default Alarm: NON16-XStation Exchanged ReportDefault Grade: 0Grade Modified: Lamp Modified: b0-b7: See table
NDA-24238 CHAPTER 3 Page 201 Revision 3.0 SYSTEM MESSAGES ➁ Tenant No. of calling station ➂ Accommodated location of calling station after Follow Phone service ➃ Accommodated location of calling station after Follow Phone service 18 Call Back/OG queuing has been set to Calling or Called station 19 Call Forwarding - All Calls has been set to Calling or Called station 20 Call Forwarding - Busy Line has been set to Calling or Called station 21 Call Forwarding - Don’t Answer has been set to Calling or Called station 22-31 - 32 Under processing of Data Memory Back Up 33 Collision of swap service Under swapping of One Touch Memory Memory overflow (Max. 4 stations) 34 Data Memory read error 35 Data Memory swap failure 36 OAI Terminal Information swap failure (CM Data) 37 OAI Terminal Information swap failure (LP Data) 38 SST Time out b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 ERROR CODE (HEX)FAILURE b0-b3: Tenant No. (1-15) b4-b7: Tenant No. (over 15) b0-b2: Level b3-b7: Group (0-22) b0, b1: Unit No. (0-3) b2-b7: MG No.
CHAPTER 3 NDA-24238 Page 202 Revision 3.0 SYSTEM MESSAGES ➄-➆ Station No. of calling station ➇ Tenant No. of called station ➈ Accommodated location of called station ➉ Accommodated location of called station 11 - 13 Station No. of called station 14 Data Analyzed by NEC Engineers b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b7 b6 b5 b4 b3 b2 b1 b0 b4-b7b0-b3 ➄DC0 DC1 ➅DC2 DC3 ➆DC4 DC5 b0-b3: Tenant No. (1-15) b4-b7: Tenant No. (over 15) b0-b2: Level b3-b7: Group b0, b1: Unit No. (0-3) b2-b7: MG No. b4-b7b0-b3 11DC0 DC1 12DC2 DC3 13DC4 DC5
NDA-24238 CHAPTER 3 Page 203 Revision 3.0 SYSTEM MESSAGES This message displays when the MBR switch on the CCH/DCH card is turned ON. ➀ Location of CCH/DCH card ➁ CKT No. 1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000 ➀ ➁ 4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000 7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000 b7 b6 b5 b4 b3 b2 b1 b0 b7 b1 b0 Default Alarm: NON17-ACCH MBR Key Turn ONDefault Grade: 3Grade Modified: Lamp Modified: b0-b4: Group No. b5, b6: Unit No. (0-3) b7: MG No. 0/1 = Even-numbered MG/Odd-numbered MG b0, b1: CKT No. (0-3)