    							CHAPTER 3 NDA-24238
    Page 194
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the DR signal of the RS-232C, connected to the port designated by the system
    data, remains off for 30 consecutive seconds while the system is in service (immediately after startup in the
    case of system start-up).
    ➀ Faulty Port No.
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON16-KI/O Port Line OFFDefault Grade:
    1Grade Modified: Lamp Modified:
    0/1 = -/Link Down
    b0: Port 0 b4: Port 4
    b1: Port 1 b5: Port 5
    b2: Port 2 b6: Port 6
    b3: Port 3 b7: Port 7
    IOC0IOC1 
    						
    							NDA-24238 CHAPTER 3
    Page 195
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when [16-K] I/O Port Line Down Failure is restored to normal.
    ➀ Faulty Port No. 
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON16-LI/O Port Line RestoreDefault Grade:
    1Grade Modified: Lamp Modified:
    0/1 = -/Link Down
    b0: Port 0 b4: Port 4
    b1: Port 1 b5: Port 5
    b2: Port 2 b6: Port 6
    b3: Port 3 b7: Port 7
    IOC0IOC1 
    						
    							CHAPTER 3 NDA-24238
    Page 196
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the timer circuit in the EMA card becomes faulty and stops functioning and 64-
    Hz clock alarm is output.
    ➀ Message Detail Data
    This system message is always indicated as 0000.
    1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    Default Alarm:
    SUP16-MHard Clock FailureDefault Grade:
    3Grade Modified: Lamp Modified: 
    						
    							NDA-24238 CHAPTER 3
    Page 197
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when [16-M] 64 Hz Clock Down Detected is restored to normal.
    ➀ Message Detail Data
    This system message is always indicated as 0000.
    1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    Default Alarm:
    NON16-NHard Clock RestoreDefault Grade:
    3Grade Modified: Lamp Modified: 
    						
    							CHAPTER 3 NDA-24238
    Page 198
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the IOC card fails.
    ➀ IOC circuit card No.
    ➁ Cause for fault
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b4 b3 b2 b1 b0
    Default Alarm:
    SUP16-TIOC Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0/No. 1
    b0: 0/1 = -/COP Alarm
    b1: 0/1 = -/CLK Alarm
    b2: 0/1 = -/MEM bus CLK Alarm
    b3: 0/1 = -/Abnormal Interruption
    b4: 0/1 = -/Infinite Loop Detected 
    						
    							NDA-24238 CHAPTER 3
    Page 199
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the IOC card failure, observed in the message [16-T], is detected more than 8
    times a day.
    ➀ IOC circuit card No.
    ➁ Cause for fault
    Reference: See Chapter 4, Section 1.3.3, for the circuit card replacement procedure.
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    b7 b4 b3 b2 b1 b0
    Default Alarm:
    SUP16-UIOC Failure (Permanent)Default Grade:
    2Grade Modified: Lamp Modified:
    b0: 0/1 = No. 0/No. 1
    b0: 0/1 = -/COP Alarm
    b1: 0/1 = -/CLK Alarm
    b2: 0/1 = -/MEM bus CLK Alarm
    b3: 0/1 = -/Abnormal Interruption
    b4: 0/1 = -/Infinite Loop Detected 
    						
    							CHAPTER 3 NDA-24238
    Page 200
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the user uses Follow Phone (SWAP) service.
    ➀ Error code
    1: XXXX XXXX XXXX XX00 2: XXXX XXXX XXXX 00XX 3: XXXX 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉ 1112 13 14 14
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    ERROR CODE (HEX)FAILURE
    00 Normal End
    01 MG unmatch
    02 Called party is not the station
    03 TEC of Calling or Called station is abnormal
    04 TEC unmatch
    05 Hunting group unmatch
    06 Call Pick Up group unmatch
    07 Calling or Called station is Night station
    08 Call Pick Up Expand group unmatch
    09 -
    10 Calling or Called D
    term has Data Line
    11 Calling or Called D
    term has OAI function key
    12 Calling or Called station is Agent/Supervisor (ACD)
    13-15 -
    16 Called station is busy
    17 MW has been set to Calling or Called station
    Default Alarm:
    NON16-XStation Exchanged ReportDefault Grade:
    0Grade Modified: Lamp Modified:
    b0-b7: See table 
    						
    							NDA-24238 CHAPTER 3
    Page 201
    Revision 3.0
    SYSTEM MESSAGES
    ➁ Tenant No. of calling station
    ➂ Accommodated location of calling 
    station after Follow Phone service
    ➃ Accommodated location of calling 
    station after Follow Phone service
    18 Call Back/OG queuing has been set to Calling or Called station
    19 Call Forwarding - All Calls has been set to Calling or Called station
    20 Call Forwarding - Busy Line has been set to Calling or Called station
    21 Call Forwarding - Don’t Answer has been set to Calling or Called station
    22-31 -
    32 Under processing of Data Memory Back Up
    33  Collision of swap service
     Under swapping of One Touch Memory
     Memory overflow (Max. 4 stations)
    34 Data Memory read error
    35 Data Memory swap failure
    36 OAI Terminal Information swap failure (CM Data)
    37 OAI Terminal Information swap failure (LP Data)
    38 SST Time out
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    ERROR CODE (HEX)FAILURE
    b0-b3: Tenant No. (1-15)
    b4-b7: Tenant No. (over 15)
    b0-b2: Level
    b3-b7: Group (0-22)
    b0, b1: Unit No. (0-3)
    b2-b7: MG No. 
    						
    							CHAPTER 3 NDA-24238
    Page 202
    Revision 3.0
    SYSTEM MESSAGES
    ➄-➆ Station No. of calling station
    ➇ Tenant No. of called station
    ➈ Accommodated location of called 
    station
    ➉ Accommodated location of called 
    station
    11 - 13 Station No. of called station
    14 Data Analyzed by NEC Engineers b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b4-b7b0-b3
    ➄DC0 DC1
    ➅DC2 DC3
    ➆DC4 DC5
    b0-b3: Tenant No. (1-15)
    b4-b7: Tenant No. (over 15)
    b0-b2: Level
    b3-b7: Group
    b0, b1: Unit No. (0-3)
    b2-b7: MG No.
    b4-b7b0-b3
    11DC0 DC1
    12DC2 DC3
    13DC4 DC5 
    						
    							NDA-24238 CHAPTER 3
    Page 203
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the MBR switch on the CCH/DCH card is turned ON.
    ➀ Location of CCH/DCH card
    ➁ CKT No.
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b1 b0
    Default Alarm:
    NON17-ACCH MBR Key Turn ONDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG
    b0, b1: CKT No. (0-3) 
    						
    All NEC manuals Comments (0)