    							CHAPTER 3 NDA-24238
    Page 124
    Revision 3.0
    SYSTEM MESSAGES
    In a specific time cycle, the system allows a routine diagnosis in its hardware and software to determine if they
    are operating properly. This message indicates that the system has been checked by the routine diagnosis pro-
    gram and the result of the diagnosis is normal.
    ➀ Performed Diagnosis Item
    Note:The data in this area will be diverse, according to the diagnosis specified in ➀. For details on each
    item data, see the following pages.
    1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    Note
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON7-OCyclic Diagnosis NormalDefault Grade:
    3Grade Modified: Lamp Modified:
    [00H] Routine Diagnosis Start
    [10H] Program Memory Verification Normal End
    [20H] Data Memory Verification Normal End
    [30H] TSW ACT/STBY Changeover Normal End
    [40H] CPU ACT/STBY Changeover Normal End
    [50H] No Trunk Ineffective Hold
    [70H] Call Forwarding Memory Clear Normal End
    [A0H] Periodic Back-up Normal End
    [C0H] Detection of Remaining Link Normal End 
    						
    							NDA-24238 CHAPTER 3
    Page 125
    Revision 3.0
    SYSTEM MESSAGES
    [00H] Routine Diagnosis Start
    ➀ Performed Diagnosis Item
    ➁ Pending Diagnosis Menu (SYS1, 
    Index 89)
    ➂ Pending Diagnosis Menu (SYS1, 
    Index 90)
    1: 00XX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b1 b0
    [00H] Routine Diagnosis Start
    b0: 0/1=-/Program Memory Verification
    b1: 0/1=-/Data Memory Verification
    b2: 0/1=-/TSW ACT/STBY Changeover
    b3: 0/1=-/CPU ACT/STBY Changeover
    b4: 0/1=-/Trunk Ineffective Hold Check
    b5: 0/1=-/Trunk Ineffective Hold Detection
    b6: 0/1=-/Call Forwarding Memory clear
    b7: 0/1=-/IP ACT/STBY changeover
    b0: Not used
    b1: Periodic Back-up
    b2-b7: Not used 
    						
    							CHAPTER 3 NDA-24238
    Page 126
    Revision 3.0
    SYSTEM MESSAGES
    [10H] Program Memory Verification Normal End
    ➀ Routine Diagnosis
    ➁ Information on HD
    ➂ Verification of Drive Number
    1: 10XX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    b7 b3 b2 b1 b0
    [10H] Program Memory Verification Normal End
    b0: 0/1 = -/HFC 0 is normal
    b1: 0/1 = -/HFC 1 is normal
    b0: 0/1 = -/Drive Number 0
    b1: 0/1 = -/Drive Number 1
    b2: 0/1 = -/Drive Number 2
    b3: 0/1 = -/Drive Number 3 
    						
    							NDA-24238 CHAPTER 3
    Page 127
    Revision 3.0
    SYSTEM MESSAGES
    [20H] Data Memory Verification Normal End
    ➀ Routine Diagnosis
    ➁ Verification of HD
    ➂ Verification of Data Memory
    1: 20XX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    b7 b2 b1 b0
    [20H] Data Memory Verification Normal End
    b0: 0/1 = -/HFC 0 is normal
    b1: 0/1 = -/HFC 1 is normal
    b0: 0/1 = -/Data Memory
    b1: 0/1 = -/Local Data Memory
    b2: 0/1 = -/Network Data Memory 
    						
    							CHAPTER 3 NDA-24238
    Page 128
    Revision 3.0
    SYSTEM MESSAGES
    [30H] TSW ACT/STBY Changeover Normal End
    ➀ Routine Diagnosis
    ➁ Active TSW system after 
    changeover
    1: 30XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b0
    [30H] TSW ACT/STBY Changeover Normal End
    b0: 0/1 = TSW No. 0 is ACT/
    TSW No. 1 is ACT 
    						
    							NDA-24238 CHAPTER 3
    Page 129
    Revision 3.0
    SYSTEM MESSAGES
    [40H] CPU ACT/STBY Changeover Normal End
    ➀ Routine Diagnosis
    ➁ Active CPU system
    1: 40XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    [40H] CPU ACT/STBY Changeover Normal End
    b0: CPU
    0/1 = #0 is ACT/#1 is ACT
    b1: TSW
    0/1 = #0 is ACT/#1 is ACT 
    						
    							CHAPTER 3 NDA-24238
    Page 130
    Revision 3.0
    SYSTEM MESSAGES
    [50H] No Trunk Ineffective Hold
    ➀ Routine Diagnosis
    ➁ MG and Unit of No. of Trunk 
    Ineffective Hold
    1: 50XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    [50H] Trunk Ineffective Hold
    b0: Unit 0, Even-numbered MG 
    1 = No Trunk Ineffective Hold
    b1: Unit 1, Even-numbered MG 
    1 = No Trunk Ineffective Hold
    b2: Unit 2, Even-numbered MG 
    1 = No Trunk Ineffective Hold
    b3: Unit 3, Even-numbered MG 
    1 = No Trunk Ineffective Hold
    b4: Unit 0, Odd-numbered MG 
    1 = No Trunk Ineffective Hold
    b5: Unit 1, Odd-numbered MG 
    1 = No Trunk Ineffective Hold
    b6: Unit 6, Odd-numbered MG 
    1 = No Trunk Ineffective Hold
    b7: Unit 3, Odd-numbered MG 
    1 = No Trunk Ineffective Hold 
    						
    							NDA-24238 CHAPTER 3
    Page 131
    Revision 3.0
    SYSTEM MESSAGES
    [70H] Call Forwarding Memory Clear Normal End
    ➀ Routine Diagnosis
    1: 7000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    [70H] Call Forwarding Memory Clear Normal End 
    						
    							CHAPTER 3 NDA-24238
    Page 132
    Revision 3.0
    SYSTEM MESSAGES
    [A0H] Periodic Back-up Normal
    ➀ Routine Diagnosis
    ➁ Information on Periodic Backup 
    Normal End
    ➂ Backup Data to No. 0 system
    ➃Backup Data to No. 1 system
    Note:Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS.
    1: A0XX XX00 0000 XX00 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    [A0H] Periodic Back-up Normal
    b0: 0/1 = HFD0 Normal end/Abnormal end
    b1: 0/1 = HFD1 Normal end/Abnormal end
    b0: 0/1 = -/Individual Speed Calling Data
    b1: 0/1 = -/Call Forwarding Data
    b2: 0/1 = -/RCF
    b3: 0/1 = -/Name Display Data
    b4: 0/1 = -/User Assign Soft Key Data
    b5: 0/1 = -/Number Sharing DataNote
    b6: 0/1 = -/Call Block Data
    b0: 0/1 = -/Individual Speed Calling Data
    b1: 0/1 = -/Call Forwarding Data
    b2: 0/1 = -/RCF
    b3: 0/1 = -/Name Display Data
    b4: 0/1 = -/User Assign Soft Key Data
    b5: 0/1 = -/Number Sharing DataNote
    b6: 0/1 = -/Call Block Data 
    						
    							NDA-24238 CHAPTER 3
    Page 133
    Revision 3.0
    SYSTEM MESSAGES
    [C0H] Detection of Remaining Link Normal End 
    ➀ Performed Diagnosis Item
    1: C0XX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    [C0H] Detection of Remaining Link Normal End 
    						