    							CHAPTER 3 NDA-24238
    Pag e 8 4
    Revision 3.0
    SYSTEM MESSAGES
    ➄ Error status on PCI slot 3
    Note 1:Physical Connection Error
     Ethernet cable is disconnected.
     Ethernet cable has short-circuited.
     Ethernet straight/cross cable selection error
    Note 2:Hardware Fault
     Transmitter failure
     Controller lock-up b7 b1 b0
    b0: 0/1 = -/Physical connection error Note 1
    b1: 0/1 = -/Hardware Fault Note 2 
    						
    							NDA-24238 CHAPTER 3
    Page 85
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the PCI card, which was detected as faulty, is recovered.
    ➀ Detection of PCI restoration
    ➁Details on error restoration (PCI 
    slot 0)
    ➂Details on error restoration (PCI 
    slot 1)
    ➃Not used
    1: 0X0X 0X0X 0X00 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b3 b2 b1 b0
    b7 b0
    b7 b0
    Default Alarm:
    MN4-VPCI Card Failure RecoveredDefault Grade:
    3Grade Modified: Lamp Modified:
    b0: 0/1 = -/Error detection on PCI slot 0 (LANI-A)
    b1: 0/1 = -/Error detection on PCI slot 1
    b2: 0/1 = -/Error detection on PCI slot 2 (Not used)
    b3: 0/1 = -/Error detection on PCI slot 3 (LANI-B)
    b0: 0/1 = -/Physical connection error restoration Note
    b0: 0/1 = -/Physical connection error restoration Note 
    						
    							CHAPTER 3 NDA-24238
    Pag e 8 6
    Revision 3.0
    SYSTEM MESSAGES
    ➄Details on error restoration (PCI 
    slot 3)
    Note:Physical Connection Error
     Ethernet cable is disconnected.
     Ethernet cable has short-circuited.
     Ethernet straight/cross cable selection error b7 b0
    b0: 0/1 = -/Physical connection error restoration Note 
    						
    							NDA-24238 CHAPTER 3
    Page 87
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when any of the following faults are detected:
     Power failure
     Fuse blowing
     In-Frame abnormal temperature
    ➀ Probable cause for failure
    ➁Frame in which a fault is detected
    ➂ Factor of failure
    Reference: See Chapter 5, Section 8, for the repair procedure.
    1: XX00 XXXX 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀  ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b4 b3 b2 b1 b0
    Default Alarm:
    NON6-ASystem FailureDefault Grade:
    3Grade Modified:
    (FIXED) NONLamp Modified:
    (FIXED) 3
    b0: Input power (-48V) down/abnormal detected
    b1: PWR Supply abnormal detected
    b2: PWR Supply Fuse Blown detected
    b3: Abnormal temperature MJ (70ºC (158ºF))
    b4: Abnormal temperature MN (60ºC (140ºF))
    b0-b3: Frame No. (0 Only)
    0/1 = CPU is mounted/Not mounted
    b4, b5: Frame Group No. 
    b6, b7: Kind of frame
    00 = IMG
    b0: 0/1 = -/OBP Alarm 0 side
    b1: 0/1 = -/OBP Alarm 1 side
    b2: 0/1 = -/OBP Alarm MISC side
    b3: 0/1 = -/Power Alarm 0 side
    b4: 0/1 = -/Power Alarm 1 side 
    						
    							CHAPTER 3 NDA-24238
    Pag e 8 8
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a fault in either the ringer or howler tone occurs in the PWR card.
    ➀Unit and MG number of fault 
    detection
    ➁ Kind of fault
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b2 b1 b0
    b7 b1 b0
    Default Alarm:
    MN6-BRGU & Howler FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0, b1: Unit No. (0-3)
    b2: 0/1 = Even-numbered MG/Odd-numbered MG
    b0: 0/1 = -/RGU (Ringing Unit) Fault
    b1: 0/1 = -/Howler Fault 
    						
    							NDA-24238 CHAPTER 3
    Page 89
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the CPU usage (occupancy) rate exceeds the value assigned to ASYD, SYS1, In-
    dex 56, and the call origination from the pre-selected group of stations is restricted (i.e., Line Load Control is
    set). This system message is always indicated as 0.
    1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    Default Alarm:
    NON6-CLine Load Control StartDefault Grade:
    3Grade Modified: Lamp Modified: 
    						
    							CHAPTER 3 NDA-24238
    Pag e 9 0
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the CPU usage (occupancy) rate becomes lower than the value assigned to ASYD,
    SYS1, Index 57, and Line Load Control is cancelled. This system message is always indicated as 0.
    1: 0000 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    Default Alarm:
    NON6-DLine Load Control StopDefault Grade:
    2Grade Modified: Lamp Modified: 
    						
    							NDA-24238 CHAPTER 3
    Page 91
    Revision 3.0
    SYSTEM MESSAGES
    This message displays to indicate the result of Bad Call Notification.
    ➀ 
    When type of connection is Station connection
    ➁ - ➃ Station number (see table)
    ➄ The called station number
    1: XXXX XXXX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉11
    12
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b3 b2 b1 b0
    Default Alarm:
    SUP6-HBad Call NotificationDefault Grade:
    2Grade Modified: Lamp Modified:
    b0-b3: Station number digit with the fault. (This data is always indicated as 
    “0” when Type of connection is 2 (ACD Trunk).)
    b4-b7: Type of connection
    0 = Station connection
    1 = Trunk connection
    2 = ACD Trunk connection
    b4-b7b0-b3
    ➁DC0 DC1
    ➂DC2 DC3
    ➃DC4 DC5
    b0-b3: Number of digits for called station number 
    						
    							CHAPTER 3 NDA-24238
    Pag e 9 2
    Revision 3.0
    SYSTEM MESSAGES
    ➅ - ➇ Called station number (See 
    table)
    ➈ Time Slot Number of Link 1 
    ➉ Not used
     Time Slot Number of Link 2 
     Not used
    When type of connection is Trunk connection
    ➁ - ➃ Station number (See table)
    ➄ Remote Route No.
    ➅ Remote Route No. b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b3 b2 b1 b0
    b4-b7b0-b3
    ➅DC0 DC1
    ➆DC2 DC3
    ➇DC4 DC5
    11
    12
    b4-b7 b0-b3
    ➁DC0 DC1
    ➂DC2 DC3
    ➃DC4 DC5
    b0-b5: Route No. (1-63)
    b6: OP
    0/1 = Data in OPRT is invalid/valid
    b7: AC
    0/1 = Internal trunk/External trunk
    b0-b3: OPRT Route No. (Over 64) 
    						
    							NDA-24238 CHAPTER 3
    Page 93
    Revision 3.0
    SYSTEM MESSAGES
    ➆ Called Trunk No.
    ➇ Not used
    ➈ Time Slot Number of Link 1 
    ➉ Not used
     Time Slot Number of Link 2 
     Not used b7 b6 b5 b4 b3 b2 b1 b0
    b0-b7: Trunk No. 
    11
    12 
    						