CHAPTER 6 NDA-24238 Page 414 Revision 3.0 SYSTEM OPERATIONS 7.2.7 Call Metering Information The value of call metering from the Central Office is transmitted via the data from the 92nd byte to 95th byte. 7.2.8 Office Code of Calling (Called) Party and Billing Process Office The 96th byte through 99th byte indicates the Office Code of Calling (Called) Party terminated via CCIS line. The 100th byte through 103rd byte indicates the Office Code of the office processing centralized bill- ing for CCIS network. Note:Office Code includes the CCIS line access code. BYTE 92 93 94 95WHEN 5200 METERING PULSES EXAMPLE 5 2 0 0 ARE RECEIVED FROM C.O. DATA 1000 100 10 1 OFFICE CODE = 812 BYTE 96 97 98 99 100 101 102 103DATA 1st DIGIT 2nd DIGIT 3rd DIGIT 4th DIGIT 1st DIGIT 2nd DIGIT 3rd DIGIT 4th DIGITEXAMPLE 8 1 2 SPACE 8 1 3 SPACEOFFICE CODE = 813OFFICE CODE OF BILLING PROCESS OFFICE OFFICE CODE OF CALLING (CALLED) PA R T Y
NDA-24238 CHAPTER 6 Page 415 Revision 3.0 SYSTEM OPERATIONS 7.2.9 Text Format of Centralized Billing - Fusion Below is the text format for billing information (Fusion) to be transmitted to the SMDR equipment. On the following pages, Figure 6-17 through Figure 6-19, provide detailed information. Table 6-4 Centralized Billing—Fusion Kinds of Data KIND OF DATACONTENTSKK (OUTGOING)KL (INCOMING)KM (STATION) 00 Not Used 01 Outgoing Trunk/Incoming Trunk Information Provided Provided - 02 Calling Party Information (Station Number) Provided - Provided 03 Calling Party Information (Telephone Number) Conditionally Provided- Conditionally Provided 04 Called Party Information (Station Number) - Provided Provided 05 Called Party Information (Telephone Number) - Conditionally ProvidedConditionally Provided 06 Call Start/Call End Time Provided Provided Provided 07 Account Code Conditionally ProvidedConditionally ProvidedConditionally Provided 08 Condition B Information Provided Provided Provided 09 Alternate Routing Information/Incoming Route NumberProvided Provided - 10 Dial Code Provided Conditionally Provided- 11 Office Code Information (For CCIS) Conditionally ProvidedConditionally Provided- 12 Authorization Code Conditionally ProvidedConditionally Provided- 13 Condition C Information + Billing Info/Call Metalling InfoProvided Conditionally Provided- STX : Star t of Text ETX : End of Text KK : Outgoing KL : Incoming KM : Extension S T XE T X Transmission Data 0! KK / L / MKind of Data NoteData LengthKind of DataData LengthTransmission Data Note:For details on the Kind of Data, see Ta b l e 6 - 4.
CHAPTER 6 NDA-24238 Page 416 Revision 3.0 SYSTEM OPERATIONS Note: Conditionally Provided: Information is provided when data is effective. Provided: Information is provided on every call with no exception. -: Not available. 14 Condition D Information + Bill Notification Attendant Console NumberConditionally Provided-- 15 Department Code Conditionally Provided-- 16 Automatic Number Indication Conditionally ProvidedConditionally Provided- 17 Converted Number Conditionally Provided-- 18-99 Not Used - - -Table 6-4 Centralized Billing—Fusion Kinds of Data (Continued) KIND OF DATACONTENTSKK (OUTGOING)KL (INCOMING)KM (STATION)
NDA-24238 CHAPTER 6 Page 417 Revision 3.0 SYSTEM OPERATIONS Figure 6-17 Message Format for Outgoing Call - Fusion Byte Data 1 105 15 25 20 30 40 35 45 55 50 60 65 STX 0 ! K K 0 1 1 FPC (3 digits) Physical Route No. Trunk No. Logical Route No. 0 2 1 ORIG Tenant (3 digits) STN No. ATT CON No. RT/TK No. (6 digits) 0 3 02 FPC (3 digits) User Group Number Telephone Number (Max. 16 digits) / Logical Route No. 0 6 3 Year Byte Data 80 75 85 95 90 100 110 105 115 125 120 130 135 Milli-Second 0 7 01 Account Code (Max. 16 digits) 0 9 1 FPC1 Outgoing Trunk Information Calling Par ty Information (Station No.) Note Calling Par ty Information (Telephone No.) Call Start Time Minute Second Ye a r Month Milli-Second Day Hour Minute Second 0 8 0 C2 C1 C0 Logical RT No. 1 Physical RT No. 1 Call End Time Account Code Condition B Information Note Alternate Routing Information Note 150 155 165 160 170 180 175 185 195 190 200 205 1 0 03 Dial Code (Max. 32 digits) 1 2 01 1 1 0Dial Code Office Code Information Authoriza- tion Code Byte Data Office Code of Calling Pa r t y Office Code of Billing Pro- cess Office Authoriza- tion Code (Max 16 digits.) 220 225 235 230 240 250 245 255 265 260 270 275 Condition D Information Note Automatic Number Indication Note Department Code Billing Informa- tion /Call Metering 1 4 00 D Bill Notifi- cation ATT CON No. Condition C Information Note 1 5 01 5 0 1 6 03 Department Code ETX ~ ~~~ ~ , * 70Day Hour Month 140 145 Logical RT No. 2 Physical RT No. 2 Byte Data 280 285 Automatic Number Indication (Max. 32 digits) 1 7 00 16 Converted Number (Max. 6 digits)~ FPC2 1 3 0, 0, 0 210 215 C Converted Number For more information on the data to which the Note marks are attached, see Reference.
CHAPTER 6 NDA-24238 Page 418 Revision 3.0 SYSTEM OPERATIONS Figure 6-18 Message Format for Incoming Call - Fusion Office Code of Billing Process Office Byte Data 1 105 15 25 20 30 40 35 45 55 50 60 65STX 0 ! K L 0 1 1 2 FPC (3 digits) Physical Route No. Trunk No. Logical Route No. 0 4 1 0 ORIG (Note) Tenant (3 digits) STN No. ATT CON No. RT/TK No. (6 digits) 05 02 32 FPC (3 digits) User Group Number (3 digits) Telephone Number (Max. 16 digits) / Logical Route No. (3 digits) 0 6 3 4 Year Byte Data 70 80 75 85 95 90 100 110 105 115 125 120 130 Milli-Second 0 7 01 16 Account Code (Max. 16 digits) 0 9 1 8 FPC1 Incoming Tr u n k Information Called Par ty Information (Station No.) Called Par ty Information (Telephone No.) Call Star t Time Day Hour Minute Second Year Month Milli-Second Day Hour Minute Second 0 8 C0 Logical RT No. 1 Physical RT No. 1 Call End Time Account Code Condition B Information Note Incoming Route Number Note 140 150 145 155 165 160 170 180 175 185 195 190 200 1 0 03 12 Dial Code (Max. 32 digits) 1 2 01 16 FPC2 1 1 0 8 Logical RT No. 2 Physical RT No. 2 Dial Code Office Code Information Byte Data Office Code of Calling Par ty 210 220 215 225 235 230 240 250 245 255 1 3 Automatic Number Indication (Max. 32 digits) Automatic Number Indication Note Byte Data C Condition C Information Note ETX Month135 205 1 6 03 13Call Metering Authoriza- tion Code (Max. 16 digits)Authorization Code For more information on the data to which the Note marks are attached, see Reference. ~ ~ 0 3 C2 C1 ~ ~ ~ * 0 5
NDA-24238 CHAPTER 6 Page 419 Revision 3.0 SYSTEM OPERATIONS Figure 6-19 Message Format for Station-to-Station Call - Fusion Byte Data 1 105 15 25 20 30 40 35 45 55 50 60 65STX 0 ! K M 0 2 1 0 FPC (3 digits) ORIG (Note) Tenant (3 digits) STN No. ATT CON No. (6 digits) 05 02 32 FPC (3 digits) User Group Number (3 digits) Telephone Number (Max. 16 digits) Byte Data 70 80 75 85 95 90 100 110 105 115 125 120 130 Milli-Second 0 6 Account Code (Max. 16 digits) Calling Party Information (Station No.) Calling Party Information (Telephone No.)Call Start Tim e Day Hour Minute Second Ye a r Month Milli-Second Day Hour Minute SecondC2 C1 C0 Call End Time Account Code 140 145 0 7 01 16 0 4 1 0 Byte Data 0 8 0 3 Condition B Information Note ETX Month135 For more information on the data to which the Note marks are attached, see Reference. 0 3 02 72 ORIG (Note) Tenant (3 digits) STN No. ATT CON No. (6 digits) User Group Number(3 digits) Telephone Number (Max. 16 digits) Ye a r Called Party Information (Station No.)Called Party Information (Telephone No.) 3 4 ~ ~ ~
CHAPTER 6 NDA-24238 Page 420 Revision 3.0 SYSTEM OPERATIONS Reference Data = 02: Calling Party Information (Station Number) Data = 08: Condition B Information 02 10O R I GTenant (3 digits)Station No. AT T C O N N o . RT / TK No. (6 digits) ORIG: Originating Source Identification ORIG = 0: Transmitted data depicts information on Station ORIG = 1: Transmitted data depicts information on Attendant Console ORIG = 2: Transmitted data depicts information on Trunk 08 03C 2 C0 = 0: Call Origination - Direct 1: Call Origination - via ATTCON 2: Call Origination - Direct (Alternate Routing) 3: Call Origination - via ATTCON (Alternate Routing) 4: Call Origination - Direct (LCR Routing) 5: Call Origination - via ATTCON (LCR Routing) 6: Call Origination - Direct (Called No. - first 6 digits of change code) 7: Call Origination - via ATTCON (Called No. - first 6 digits of change code) C1 = 0: - 1: Call Origination by OG Queuing 2: Call Origination by dialing with accounted code 3: Call Origination by OG Queuing & dialing with accounted code 4: Call Origination by Call Forwarding Outside 5: - 6: Call Origination by Call Forwarding Outside & dialing with accounted code C2 = 0: - 1: Call was transferred 2: Billing is continued 3: Call was transferred & billing is continued 4: Call was transferred to last called party C 1C 0
NDA-24238 CHAPTER 6 Page 421 Revision 3.0 SYSTEM OPERATIONS Data = 09: Alternate Routing Information (KK) / Incoming Route Number (KL) Data = 13: Condition C Information + Billing Info / Call Metering Info. 09 18FPC1 (3 digits) FPC1: FPC actually used Physical Route No. 1: Physical route actually used Logical Route No. 1: Logical route actually used FPC2: FPC first selected Physical Route No. 2: Physical route first selected Logical Route No. 2: Logical route first selectedPhysical RT No. 1Logical RT No. 1FPC2 (3 digits)Physical RT No. 2Logical RT No. 2 1301 05 07CBilling Info / Call Metering In case of Billing Information Charge Data (Basic Charge Unit x 100) Charge Data (Basic Charge Unit x 101) Charge Data (Basic Charge Unit x102) Charge Data (Basic Charge Unit x103) Charge Data (Basic Charge Unit x104) Charge Data (Basic Charge Unit x105) 0: No Charge Information 1: Charge Information for 1 cent unit 2: Charge Information for 0.1 cent unit 3: Charge Information for 10 cent unit 4: Charge Information for $1 unit 5: Charge Information for $10 unit 6: Calling Metering (4 digits) F: Charge Information Error
CHAPTER 6 NDA-24238 Page 422 Revision 3.0 SYSTEM OPERATIONS Data = 14: Condition D Information + Bill Notification ATT CON Number Data = 16: Automatic Number Indication 1401 04DBill Notification AT T C O N Number D - : Bill Notification (by ATTCON) Not Available 0 : Bill Notification (by ATTCON) Not Applied 1 : Bill Notification (by ATTCON) Available 1601 33* * Information Element Identifier = 0: Unable to Output 1: Display 2: Unable to Notify 3: Out of Service (Out of Area) 4: Public Telephone OriginationAutomatic Number Indication (Max. 32 digits)~
NDA-24238 CHAPTER 6 Page 423 Revision 3.0 SYSTEM OPERATIONS 7.2.10 Text Format of SMDR - TCP/IP Interface When using SMDR - TCP/IP interface, billing information is output to the billing output devices con- nected by an external LAN in the form of socket interface as shown in Figure 6-20. This feature is available for software Release 3 or later. Figure 6-20 SMDR—TCP/IP Interface Billing Output Devices Details on the text format for SMDR - TCP/IP Interface are explained below. (1) Identifier 1: Data Request Text A text to be sent by the client when it requests the server to send billing data. Text sending direction: Client Server SMDR(A) (Client)SMDR(B) (Client)SMDR(C) (Client)SMDR(D) (Client) PBX(Server) LANBilling Information Note:A maximum of 4 clients can be designated as SMDR equipment for each LN. Data length (00002) Text identifier (1) S Y NParity Device No.