Home > NEC > Communications System > NEC Neax 2400 Imx System Operations And Maintenance Manual

NEC Neax 2400 Imx System Operations And Maintenance Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Imx System Operations And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 647
    							CHAPTER 7 NDA-24238
    Page 514
    Revision 3.0
    ROUTINE MAINTENANCE PROCEDURE
    RST (/)
    FUNCTION
    TRUNK NO.ORT
    SENDER REMARKS
    PB RECEIVING DP RECEIVING
    RST No.ORT0 SND0
    11
    22
    33
    44
    55
    66
    77
    RST No.00
    11
    22
    33
    44
    55
    66
    77
    RST No.00
    11
    22
    33
    44
    55
    66
    77
    RST No.00
    11
    22
    33
    44
    55
    66
    77 
    						
    							NDA-24238 CHAPTER 7
    Page 515
    Revision 3.0
    ROUTINE MAINTENANCE PROCEDURE
    Digital Conference Function
    TEST TYPE TEST ITEM CONNECTION DIAGRAM
    Three-way 
    Conversation Perform the test by specifying 
    an 8CFT using the Connection 
    Test-Station. 
     Confirm that [6-I] system 
    message displays as a result of 
    the test.
    FUNCTION
    TRUNK NO.SPEECH RELEASE REMARKS
    CFT0
    1
    2
    3
    4
    5
    6
    7
    Speech Path for Each PIM, and Ringing Generator Unit
    NO. TEST TYPE TEST ITEM CONNECTION DIAGRAM
    1 The ATTCON/
    DESKCON is called 
    from one station in 
    each PIM.Normal speech path is confirmed 
    by calling the attendant from a 
    station located in each PIM.
    LC
    ~
    TSTT
    INT / TSW
    8CFT
    ~
    ATI
    ATTCON/
    LC
    DESKCON 
    						
    							CHAPTER 7 NDA-24238
    Page 516
    Revision 3.0
    ROUTINE MAINTENANCE PROCEDURE
    2 The operator calls 
    the station back.After normal speech path has 
    been confirmed, the attendant 
    calls the station back. Confirm 
    that the station rings.
    MOUNTING LOCATION
    CHECK REMARKS
    MODULE NAME UNIT NAME
    PIM10
    1
    2
    3
    PIM20
    1
    2
    3
    PIM30
    1
    2
    3
    PIM40
    1
    2
    3 Speech Path for Each PIM, and Ringing Generator Unit (Continued)
    NO. TEST TYPE TEST ITEM CONNECTION DIAGRAM
    ATI
    ATTCON/
    LC
    ~
    PWR0, 1
    RG
    (RINGING) DESKCON 
    						
    							NDA-24238 CHAPTER 7
    Page 517
    Revision 3.0
    ROUTINE MAINTENANCE PROCEDURE
    Attendant Console (ATTCON/DESKCON)
    TEST TYPE TEST ITEM CONNECTION DIAGRAM
    Call Termination Test   Station dials the operator 
    access code and confirm that 
    the call termination is 
    indicated at all the ATTCON/
    DESKCON.
      Station dials the operator 
    access code. An attendant 
    answers and speaks with the 
    caller. This process is repeated 
    at all the ATTCON/
    DESKCON.
    Call Origination Test   Attendant originates a call to 
    the station by pressing LOOP 
    keys one after another.
    ATI
    ATTCON/
    LC
    DESKCON
    ATTCON/
    LC
    ~RG (RINGING)
    ATI
    DESKCON 
    						
    							CHAPTER 7 NDA-24238
    Page 518
    Revision 3.0
    ROUTINE MAINTENANCE PROCEDURE
    FUNCTION
    ATTCON/
    DESKCON NO.CALL TERMINATION CALL ORIGINATION REMARKS
    INCOMING CALL 
    INDICATIONSPEECH RELEASE SPEECH RELEASE
    0
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15 
    						
    							NDA-24238 CHAPTER 8
    Page 519
    Revision 3.0
    MAINTENANCE COMMANDS
    CHAPTER 8 MAINTENANCE COMMANDS
    1. GENERAL
    This chapter explains various commands and list up commands which are used in the system administrative
    management procedure. The table below shows the list of commands.
    Table 8-1  Command List   
    COMMAND COMMAND FULL NAME REMARKS
    ALLC Assignment of Line Load Control
    ALMG Assignment of Alarm Grade Data
    ATRF Assignment of Traffic Measurement Order
    ATRFN Assignment of Traffic Measurement Order for Fusion Network
    BOSD Back Up One-Touch Speed Call Memory Data
    CADSD Continuous Assignment of Station Data
    CATK Continuous Assignment of Trunk Data
    CBCN Control of Broadcasting for NDM
    CCSE Change of Common Signaling Channel Equipment
    CDBU Change of Dch Backup
    CMOD Change of System Mode
    CMWL Control Message Waiting Lamp
    CMWL_T Control Message Waiting Lamps – Telephone Number
    CPRS Controlled Alternate PRSCs
    CSCL Continuous Change of Station Class
    CSTN Continuous Change of Station Number
    DCBD Display of Call Block Entry Data
    DCEN Display of Connection Trunk LENS Data for LDM
    DCON Display of Connection Status
    DFTD Display of System Message Details
    DISS Display of Program Issue
    DLEN Display of LENS Data
    DLSL Display of Lockout Station - LENS
    DLSS Display of Lockout Station - Number
    DLSS_T Display of Lock Out Station – Number – Telephone Number 
    						
    							CHAPTER 8 NDA-24238
    Page 520
    Revision 3.0
    MAINTENANCE COMMANDS
    DLTEL Display of Telephone Number from LENS for LDM
    DNTEL Display of Telephone Number from LENS for NDM
    DPKG Display of Setting Port Package
    DPSW Display Package Switch Status
    DSTN Display of Station Data
    DTELN Display of Telephone Number Data for NDM
    DTF101 Display of Terminal Traffic Data
    DTF102 Display of Route Traffic Data
    DTF103 Display of Station Peg Count Data
    DTF104 Display of Attendant Peg Count Data
    DTF105 Display of Route Peg Count Data
    DTF201 Display of Service Peg Count Data
    DTF301 Display of UCD Route Peg Count Data
    DTF302 Display of UCD Group Peg Count Data
    DTF303 Display of Station Peg Count Data
    DTF501 Display of Attendant Answering Peg Count Data
    DTF601 Display of Connection Route Peg Count Data
    DTF602 Display of Connection Route Traffic Data
    DTF101N Display of Terminal Traffic Data for Fusion Network
    DTF102N Display of Route Traffic Data for Fusion Network
    DTF103N Display of Station Peg Count Data for Fusion Network
    DTF104N Display of Attendant Peg Count Data for Fusion Network
    DTF105N Display of Route Peg Count Data for Fusion Network
    DTF201N Display of Service Peg Count Data for Fusion Network
    DTF301N Display of UCD Route Peg Count Data for Fusion Network
    DTF302N Display of UCD Group Peg Count Data for Fusion Network
    DTF303N Display of UCD Station Peg Count Data for Fusion Network
    DTF501N Display of Attendant Answering Peg Count Data for Fusion Network
    DTF601N Display of Connection Route Peg Count Data for Fusion Network
    DTF602N Display of Connection Route Traffic Data for Fusion NetworkTable 8-1  Command List (Continued) 
    COMMAND COMMAND FULL NAME REMARKS 
    						
    							NDA-24238 CHAPTER 8
    Page 521
    Revision 3.0
    MAINTENANCE COMMANDS
    FLINST File Install
    HDD_FDD Data Control Between HDD and FDD
    HDD_MAT Data Control Between HDD and MAT
    HDD_MAT_N Data Control Between HDD and MAT for NDM
    HDFP HDD Format of PBX
    MBCT Make Busy of Connection Trunk for LDM
    MBLE Make Busy of LENS
    MBPM Make Busy of Port Microprocessor
    MBRT Make Busy of Route
    MBSM Make Busy of System Message Printout
    MBST Make Busy of Station
    MBST_T Make Busy of Station – Telephone Number
    MBTC Make Busy of Trunk-Continuous
    MBTK Make Busy of Trunk
    MEM_HDD Data Control Between Memory and HDD
    MEM_HDD_N Data Control Between Memory and HDD for NDM
    MFCH Make Busy of FCCH
    PMBU Port Microprocessor Back Up
    RALM Release Alarm
    RALMN Release Alarm for NDM
    RLST Release Station/Trunk
    RLST_T Release of Station/Trunk – Telephone Number
    SINZ System Initialization
    SPTS Scanning of Port Status
    SRTS Scanning of Route Status
    XHFD X-RAY HD or FDD DiagnosisTable 8-1  Command List (Continued) 
    COMMAND COMMAND FULL NAME REMARKS 
    						
    							CHAPTER 8 NDA-24238
    Page 522
    Revision 3.0
    MAINTENANCE COMMANDS
    ALLC:Assignment of Line Load Control
    1. Functional Outline
    This command designates the start and stop of line load control.
    2. Parameters
    Input Data
    ALL/ONE: Operation Mode Selection (1,2)
    A=All LPs A is not valid for 1-IMG-system.
    O=Only One LP
    LP: Local Partition (LP) Number
    Note:This parameter appears when O (only one LP) is set in ALL/ONE input data.
    The data is designated as 00 for 1-IMG-system.
    STATUS: Line Load Control Status (0-3)
    0=Stop Line Load Control
    1=Start Line Load Control
    2=Automatic Line Load Control is in effect (display only)
    3=Status of all LPs do not match (display only) 
    						
    							NDA-24238 CHAPTER 8
    Page 523
    Revision 3.0
    MAINTENANCE COMMANDS
    ALMG:Assignment of Alarm Grade Data
    1. Functional Outline
    This command makes a flexible change of system message output grades. Thus, the PBX user can give a proper
    alarm grade to each system message according to their requirements. When no data is assigned, the default
    alarm grades are automatically adopted.
    Note:This command cannot change the alarm grade for [6-A] system message.
    2. Parameters
    Input data
    FK: Fault Message Kind (0-7, 10-17, 20-27, 30-37)
    FI: Fault Message Index (A-Z)
    LMP: Fault Message Lamp Data (0-3)
    0=Lamp OFF
    1=SUP Lamp ON
    2=MN Lamp ON
    3=MJ Lamp ON
    GRD: Printout Grade (0-3)
    TYPE: Listup Type (1-3)
    1=All Data
    2=Changed Data
    3=Default Data
    SYSM GRD: System Message Output Grade
    0=All Messages
    1=Not Used
    2=MN/MJ Grade Massages
    3=MJ Grade Massages 
    						
    All NEC manuals Comments (0)