    							CHAPTER 3 NDA-24238
    Page 164
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when B-level infinite loop of the Port Microprocessor (PM) in the CCH/DCH circuit
    card has occurred
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-GCCH B-Level Infinite Loop Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24238 CHAPTER 3
    Page 165
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a failure has occurred numerous times to a common channel signaling link and
    the link has been placed into make-busy state
    .
    ➀ Location of faulty CCH/DCH card
    ➁ Data Analyzed by NEC Engineers
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-HCCS Link Failure (Permanent)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24238
    Page 166
    Revision 3.0
    SYSTEM MESSAGES
    ➂ Probable cause for failure
    b7 b3 b2 b1 b0b0-b3: See Table.
    FLT IDCCITT 
    ERROR FA C TO R
    00 A S (F = 1) frame is received.
    01 B DM (F = 1) response is received.
    02 C UA (F = 1) response is received.
    03 D UA (F = 0) response is received.
    04 E DM (F = 0) response is received.
    05 F SABME command is received.
    06 G N200 Timeout (Link is set)
    07 H N200 Timeout (Link is disconnected)
    08 I N200 Timeout (Link failure is restored 
    to normal)
    09 J N (R) frame error is received.
    0A K FRMR frame is received (Link is re-set-
    up).
    0B L Undefined frame is received.
    0C M -
    0D N Improper long frame is received.
    0E O I frame with I field which exceeds 
    N201 is received.
    0F - -
    10 - Layer 1 down (for ILC)
    40 - FRMR frame is received. (Link is not 
    re-setup) 
    						
    							NDA-24238 CHAPTER 3
    Page 167
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a failure has occurred numerous times to a common channel signaling link and
    the link has been placed into make-busy state. When this fault lasts over three minutes, the system message
    changes to [13-H] CCS Link Failure (Permanent)
    .
    ➀ Location of faulty CCH/DCH card
    ➁ Data Analyzed by NEC Engineers
    1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁ ➂
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON13-ICCS Link Failure (Temporary)Default Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							CHAPTER 3 NDA-24238
    Page 168
    Revision 3.0
    SYSTEM MESSAGES
    ➂ Probable cause for the failure
    b7 b3 b2 b1 b0b0-b3: See Table.
    FLT IDCCITT 
    ERROR FAC TO R
    00 A S (F = 1) frame is received.
    01 B DM (F = 1) response is received.
    02 C UA (F = 1) response is received.
    03 D UA (F = 0) response is received.
    04 E DM (F = 0) response is received.
    05 F SABME command is received.
    06 G N200 Timeout (Link is set)
    07 H N200 Timeout (Link is disconnected)
    08 I N200 Timeout (Link failure is restored 
    to normal)
    09 J N (R) frame error is received.
    0A K FRMR frame is received (Link is re-set-
    up).
    0B L Undefined frame is received.
    0C M -
    0D N Improper long frame is received.
    0E O I frame with I field which exceeds 
    N201 is received.
    0F - -
    10 - Layer 1 down (for ILC)
    40 - FRMR frame is received. (Link is not 
    re-setup) 
    						
    							NDA-24238 CHAPTER 3
    Page 169
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when the faults pertaining to CCIS/ISDN Link are restored to normal.
    ➀ Location of faulty CCH/DCH card
    ➁ CKT No. of faulty circuit
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    NON13-JRestoration From CCS Link FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG
    b0-b7: CKT No. (0-3) 
    						
    							CHAPTER 3 NDA-24238
    Page 170
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a fault occurred to the Port Microprocessor (PM) within the CCH/DCH circuit
    card and the restart processing is executed
    .
    ➀ Location of faulty CCH/DCH card
    1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ 
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-KCCH Reset Interrupt FailureDefault Grade:
    3Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: 0/1 = Even-numbered MG/Odd-numbered MG 
    						
    							NDA-24238 CHAPTER 3
    Page 171
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a digital line failure occurs.
    ➀ Accommodated location
    ➁ Kind of Fault
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-NDigital Line WarningDefault Grade:
    1Grade Modified: Lamp Modified:
    b0-b4: Group No.
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG
    b0-b4: Kind of Fault (HEX)
    00 = -
    01 = Frame alignment loss PCM down
    02 = Bit error rate is over 10
    -6
    03 = Slip is detected 
    04 = -
    05 = Dch down
    06 = Multi-frame alignment loss
    07 = -
    10 = -
    11 = Frame alignment loss PCM down (frequently)
    12 = Bit error rate is over 10
    -4
    13 = Slip is detected (frequently)
    14 = Opposite office alarm is detected
    15 = -
    16 = Multi-frame alignment loss (frequently)
    17 = Frame alignment loss PCM down (continuously)
    18 = Multi-frame alignment loss (continuously) 
    						
    							CHAPTER 3 NDA-24238
    Page 172
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a digital line failure occurs.
    ➀ Accommodated location
    ➁ Kind of Fault
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b4 b3 b2 b1 b0
    Default Alarm:
    SUP13-ODigital Line FailureDefault Grade:
    2Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG
    b0-b4: Kind of Fault (HEX)
    00 = -
    01 = Frame alignment loss PCM down
    02 = Bit error rate is over 10
    -4
    03 = Slip is detected 
    04 = Opposite office alarm (AIS) is detected
    05 = -
    06 = Multi-frame alignment loss
    07 = Frame alignment loss PCM down (continuously)
    08 = Multi-frame alignment loss (continuously) 
    						
    							NDA-24238 CHAPTER 3
    Page 173
    Revision 3.0
    SYSTEM MESSAGES
    This message displays when a digital line failure is restored to normal.
    ➀ Accommodated location
    ➁ Kind of Fault
    1: XXXX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b4 b3 b2 b1 b0
    Default Alarm:
    NON13-PDigital Line RestoreDefault Grade:
    0Grade Modified: Lamp Modified:
    b0-b4: Group No. 
    b5, b6: Unit No. (0-3)
    b7: MG No.
    0/1 = Even-numbered MG/Odd-numbered MG
    b0-b4: Kind of Fault (HEX)
    00 = -
    01 = Frame alignment loss PCM down
    02 = Bit error rate is over 10
    -4
    03 = -
    04 = Opposite office alarm (AIS) is detected
    05 = Dch restores to normal
    06 = Multi-frame alignment loss 
    						
    All NEC manuals Comments (0)