    							CHAPTER 3 NDA-24238
    Page 144
    Revision 3.0
    SYSTEM MESSAGES
    ➆-➉ MUX card (STBY) linkage 
    condition
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    ➆Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    0: -
    1: MUX connection error 
    (functional fault/not 
    mounted) MG1
    MG0
    ➇Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    MG3
    MG2
    ➈Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    MG5
    MG4
    ➉Unit 3 Unit 2  Unit 1  Unit 0 Unit 3 Unit 2  Unit 1  Unit  0
    MG7
    MG6
    As shown in the following table, each bit represents the Unit No. allocated 
    for each MUX card in position. When “1” is set, the corresponding MUX 
    card (status: STBY) has a functional failure or is not mounted in the proper 
    location. 
    						
    							NDA-24238 CHAPTER 3
    Page 145
    Revision 3.0
    SYSTEM MESSAGES
    [41H] CPU ACT/STBY Changeover Failure
    ➀ Error detection by Routine 
    Diagnosis
    ➁ ACT system after changeover
    1: 41XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    [41H] CPU ACT/STBY Changeover Failure
    b0: CPU
    0/1 = #0 is ACT/#1 is ACT
    b1: TSW
    0/1 = #0 is ACT/#1 is ACT 
    						
    							CHAPTER 3 NDA-24238
    Page 146
    Revision 3.0
    SYSTEM MESSAGES
    [42H] CPU ACT/STBY Changeover Failure (DM Verification NG or PM Verification NG)
    ➀ Error detection by Routine 
    Diagnosis
    ➁ ACT system after changeover
    1: 42XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    [42H] CPU ACT/STBY Changeover Failure
    (DM Verification NG)
    b0: CPU
    0/1 = #0 is ACT/#1 is ACT
    b1: TSW
    0/1 = #0 is ACT/#1 is ACT 
    						
    							NDA-24238 CHAPTER 3
    Page 147
    Revision 3.0
    SYSTEM MESSAGES
    [43H] CPU ACT/STBY Changeover Failure (PCI Fault)
    ➀ Error detection by Routine 
    Diagnosis
    ➁ ACT system after changeover
    1: 43XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    [43H] CPU ACT/STBY Changeover Failure (PCI Fault)
    b0: CPU
    0/1 = #0 is ACT/#1 is ACT
    b1: TSW
    0/1 = #0 is ACT/#1 is ACT 
    						
    							CHAPTER 3 NDA-24238
    Page 148
    Revision 3.0
    SYSTEM MESSAGES
    [44H] CPU ACT/STBY Changeover Failure (Changeover NG or CPU RAM Copy NG)
    ➀ Error detection by Routine 
    Diagnosis
    ➁ ACT system after changeover
    1: 44XX 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀ ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    [44H] CPU ACT/STBY Changeover Failure
    Changeover NG or CPU RAM Copy NG)
    b0: CPU
    0/1 = #0 is ACT/#1 is ACT
    b1: TSW
    0/1 = #0 is ACT/#1 is ACT 
    						
    							NDA-24238 CHAPTER 3
    Page 149
    Revision 3.0
    SYSTEM MESSAGES
    [50H] Trunk Ineffective Hold Detected 
    ➀ Error detection by Routine 
    Diagnosis
    ➁ LENS of Trunk Ineffective Hold 
    (MG, U)
    ➂ LENS of Ineffective Hold Trunk (G, LV)
    1: 50XX 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    ➀ ➁ ➂ ➂
    4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000
    ➂➂
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b2 b1 b0
    Group No.
    1: 500X 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    Group 
    Number➀ ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉11 1213 1415 1617 18 19 20
    4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000
    25 26 21 22 23 2427 2829 30 31
    7: 0000 0000 0000 0000 8: 000 0000 0000 0000 9: 0000 0000 0000 0000
    
    Level
    b7 b6 b5 b4 b3 b2 b1 b0
    G0
    G1
    G2
    G3
    G30
    G31
    [50H] Trunk Ineffective Hold Detected
    b1
    b0
    0 0 = Unit 0
    0 1 = Unit 1
    1 0 = Unit 2
    1 1 = Unit 3
    b2: 0/1 = Even No./Odd No. Module
    0/1 = -/Ineffectively held 
    						
    							CHAPTER 3 NDA-24238
    Page 150
    Revision 3.0
    SYSTEM MESSAGES
    [51H] Trunk Ineffective Hold Detected and Released 
    ➀ Error detection by Routine 
    Diagnosis
    ➁ LENS of Trunk Ineffective Hold 
    Detected and Released (MG, U)
    ➂ LENS of Ineffective Hold Trunk (G, LV)
    1: 50XX 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    ➀ ➁ ➂ ➂ ➂
    4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000
    ➂➃
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b2 b1 b0
    Group No.
    1: 500X 00XX XXXX XXXX 2: XXXX XXXX XXXX XXXX 3: XXXX XXXX XXXX XXXX
    Group 
    Number➀ ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉11 1213 1415 1617 18 19 20
    4: XXXX XXXX XXXX XXXX 5: XXXX XX00 0000 0000 6: 0000 0000 0000 0000
    25 26 21 22 23 2427 2829 30 31
    7: 0000 0000 0000 0000 8: 000 0000 0000 0000 9: 0000 0000 0000 0000
    
    Level
    b7 b6 b5 b4 b3 b2 b1 b0
    G0
    G1
    G2
    G3
    G30
    G31
    [51H] Trunk Ineffective Hold Detected and Released
    b1
    b0
    00 = Unit 0
    01 = Unit 1
    10 = Unit 2
    11 = Unit 3
    b2: 0/1 = Even No./Odd No. Module
    0/1 = -/Ineffectively held 
    						
    							NDA-24238 CHAPTER 3
    Page 151
    Revision 3.0
    SYSTEM MESSAGES
    [52H] Trunk Ineffective Hold Detected Impossible 
    ➀ Error detection by Routine 
    Diagnosis
    ➁ Cause for suspended detection of 
    Trunk Ineffective Hold
    1: XX00 XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀  ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    [52H] Trunk Ineffective Hold Detected Impossible
    b1
    b0
    0 1 = CPU to detect is abnormal
    1 0 = Data transfer error
    1 1 = No Answer error 
    						
    							CHAPTER 3 NDA-24238
    Page 152
    Revision 3.0
    SYSTEM MESSAGES
    [70H] Call Forwarding Memory Clear NG 
    ➀ Error detection by Routine 
    Diagnosis
    ➁ Cause for which Transfer Memory 
    was stopped
    1: 7000 XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
    ➀  ➁
    4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
    b7 b1 b0
    [70H] Call Forwarding Memory Clear NG
    b1
    b0
    0 1 = CPU is abnormal
    1 0 = Data Transfer error 
    						
    							NDA-24238 CHAPTER 3
    Page 153
    Revision 3.0
    SYSTEM MESSAGES
    [A0H] Periodic Backup Abnormal End
    ➀ Error detection by Routine 
    Diagnosis
    ➁ Information of Periodic Backup 
    Abnormal End
    ➂ Backup Data to No. 0 system
    ➃ Error Code of No. 0 system HD
    Note:Number Sharing data load also affects the data load of Dual Station Calling Over-FCCS.
    1: A0XX XX00 XXXX XX00 2: XXXX XXXX XXXX XX00 3: 0000 0000 0000 0000
    ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉
    4: 0000 0000 0000 0000 5: 0000 0000 0000 00006: 0000 0000 0000 0000
    7: 0000 0000 0000 0000 8: 0000 0000 0000 00009: 0000 0000 0000 0000
    b7 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    b7 b6 b5 b4 b3 b2 b1 b0
    [A0H] Periodic Backup Abnormal End
    b0: 0/1 = HFD 0 Normal end/Abnormal end
    b1: 0/1 = HFD 1 Normal end/Abnormal end
    b0: 0/1 = -/Individual Speed Calling Data
    b1: 0/1 = -/Call Forwarding Data
    b2: 0/1 = -/RCF
    b3: 0/1 = -/Name Display Data
    b4: 0/1 = -/User Assign Soft Key Data
    b5: 0/1 = -/Number Sharing DataNote
    b6: 0/1 = -/Call Block Data
    21H:
    40H~47H:
    53H:
    57H:
    59H~5BH:
    80H~84H:
    A0H:
    A2H~A6H:
    BDH:
    C0H: Failed installation
    01H:  HD being used by another program
    02H: HD not equipped
    Parameter
    HD Fault 
    						