    							CHAPTER 1 GENERAL INFORMATION
    Line/Trunk Card
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 25
    PN-2ODTA ODT 2-line Out Band Dialling Trunk Card
    Used as either a 2-wire E&M trunk or a 4-wire E&M trunk.
    Equipped with –48V DC-DC on-board power supply.
    Both No. 0 and No. 1 circuits must be set to the same pur-
    pose (2-wire or 4-wire) in one card.
    PN-2ODTB
    [For N.Z.]ODT 2-line Out Band Dialling Trunk Card
    Used as either a 2-wire E&M trunk or a 4-wire E&M trunk.
    Equipped with –48V DC-DC on-board power supply.
    Both No. 0 and No. 1 circuits must be set to the same pur-
    pose (2-wire or 4-wire) in one card.
    PN-8RSTA PBR 8-line PB Receiver Card
    Used for a PB station line, DID or tie line.
    PN-TNTA TNT 2-line Tone/Music Source Interface Card
    Used for BGM or Music on Hold. 
    Provides two jacks for an external tone/music source.
    PN-4VCTH VCT 4-channel CODEC Card for IP Trunk
    Voice compression protocols: 
    G723.1, G729/G729A, G711, 
    FAX (14.4 kbps), DTMF signals
    Used together with PN-IPTA card.
    PZ-8PFTB PFT 8-line Power Failure Transfer Card
    To be mounted in PFT slot of PIM.
    One card per PIM.
    PZ-VM00-M VM 4-port Voice Mail Card (NEAXMail AD-8)
    One card per system.
    Number of ports : four ports (Up to eight ports when
    PZ-VM01 is mounted)
    Occupies three physical slots width per card.
    To be mounted in LT00 slot of PIM.
    PZ-VM01 VM 4-port Voice Mail Extension Card
    To be mounted on PZ-VM00-M.
    Table 1-5  Line/Trunk Card Name and Function (Continued)
    EQUIPMENT 
    NAMEFUNCTIONAL
    NAMEFUNCTION 
    						
    							CHAPTER 1 GENERAL INFORMATION
    Line Conditions of Each Terminal
    NEAX2000 IVS2 Installation Procedure ManualPage 26ND-70928 (E), Issue 1.0
    LINE CONDITIONS OF EACH TERMINAL
    The cable length between the DLC card and terminal varies depending on the type of terminal.
    This table shows the line conditions of each D
    term, DSS/BLF Console, and Attendant Console.
    Table 1-6  Line Conditions of Each Terminal 
    TERMINAL TYPE CARD TYPECABLE LENGTH*
    (Cable 0.5
    φ/24 AWG)REMARKS
    Dterm75 (Series E)
    (8 button)PN-8DLCL/8DLCP
    (STANDARD)984 ft. (300 m)NOTE 1
    PN-4DLCM/4DLCQ
    (STANDARD)984 ft.
    [3937 ft.(300 m)
    (1200 m)]
    PN-2DLCB/2DLCN
    (LONG)2788 ft.
    [3937 ft.(850 m)
    (1200 m)]
    D
    term75 (Series E)
    (16 button)PN-8DLCL/8DLCP
    (STANDARD)656 ft. (200 m)NOTE 1
    PN-4DLCM/4DLCQ
    (STANDARD)656 ft.
    [3937 ft.(200 m)
    (1200 m)]
    PN-2DLCB/2DLCN
    (LONG)2788 ft.
    [3937 ft.(850 m)
    (1200 m)]
    D
    term75 (Series E)
    (32 button)PN-8DLCL/8DLCP
    (STANDARD)656 ft. (200 m)NOTE 1
    PN-4DLCM/4DLCQ
    (STANDARD)656 ft.
    [3937 ft.(200 m)
    (1200 m)]
    PN-2DLCB/2DLCN
    (LONG)2788 ft.
    [3937 ft.(850 m)
    (1200 m)]
    *
    The value in brackets [  ] shows the cable length when local power is supplied. 
    						
    							CHAPTER 1 GENERAL INFORMATION
    Line Conditions of Each Terminal
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 27
    Dterm65 (Series III)
    (8 button)PN-8DLCL/8DLCP
    (STANDARD)984 ft. (300 m)NOTE 1
    PN-4DLCM/4DLCQ
    (STANDARD)984 ft.
    [3937 ft.(300 m)
    (1200 m)]
    PN-2DLCB/2DLCN
    (LONG)2788 ft.
    [3937 ft.(850 m)
    (1200 m)]
    D
    term65 (Series III)
    (24 button)PN-8DLCL/8DLCP
    (STANDARD)492 ft. (150 m)NOTE 1
    PN-4DLCM/4DLCQ
    (STANDARD)492 ft.
    [3937 ft.(150 m)
    (1200 m)]
    PN-2DLCB/2DLCN
    (LONG)2788 ft.
    [3937 ft.(850 m)
    (1200 m)]
    DSS/BLF Console
    NOTE 2PN-8DLCL/8DLCP
    (STANDARD)984 ft. (300 m)NOTE 1
    PN-4DLCM/4DLCQ
    (STANDARD)984 ft. (300 m)
    PN-2DLCB/2DLCN
    (LONG)2788 ft. (850 m)
    SN610 ATTCON
    (4-wire type ATTCON)PN-4DLCF
    (STANDARD) 984 ft. (300 m)
    PN-2DLCC
    (LONG)3937 ft. (1200 m)
    Table 1-6  Line Conditions of Each Terminal (Continued)
    TERMINAL TYPE CARD TYPECABLE LENGTH*
    (Cable 0.5
    φ/24 AWG)REMARKS
    *
    The value in brackets [  ] shows the cable length when local power is supplied. 
    						
    							CHAPTER 1 GENERAL INFORMATION
    Line Conditions of Each Terminal
    NEAX2000 IVS2 Installation Procedure ManualPage 28ND-70928 (E), Issue 1.0
    NOTE 1:
    When using PN-8DLCL or PN-8DLCP card, it is not available long line function, even
    if D
    term is equipped with Long Line Adapter.
    NOTE 2:
    The DSS/BLF Console requires local AC/DC power supply. SN708/709/712 
    ATTCON
    (2-wire type ATTCON)PN-8DLCL/8DLCP
    (STANDARD)984 ft. (300 m)NOTE 1
    PN-4DLCM/4DLCQ
    (STANDARD)984 ft.
    [3937 ft.(300 m)
    (1200 m)]
    PN-2DLCB/2DLCN
    (LONG)2788 ft.
    [3937 ft.(850 m)
    (1200 m)]
    SN716 DESKCON PN-8DLCL/8DLCP
    and
    PN-PW00 or 
    AC Adapter1000 ft. (304 m)
    PN-4DLCM/4DLCQ
    and
    PN-PW00 or 
    AC Adapter1500 ft. (457 m)
    Table 1-6  Line Conditions of Each Terminal (Continued)
    TERMINAL TYPE CARD TYPECABLE LENGTH*
    (Cable 0.5
    φ/24 AWG)REMARKS
    *
    The value in brackets [  ] shows the cable length when local power is supplied. 
    						
    							CHAPTER 1 GENERAL INFORMATION
    Mounting Conditions of Circuit Card
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 29
    MOUNTING CONDITIONS OF CIRCUIT CARD
    This section explains the conditions for mounting circuit cards used in the system.
    Circuit Card Mounting Slots
    The figure below shows circuit card mounting slots allocated in the PIM based on circuit card
    type.
    Figure 1-7  Circuit Card Mounting Slots
    *1
    PZ-VM00-M card is to be mounted in LT00 slot to use VM slot.
    *2
    Either line/trunk cards or application processor cards can be mounted in LT00/AP00-
    LT10/AP10 slots.
    *3
    Either PN-CP15 or a line/trunk card or an application processor card is to be mounted in 
    LT11/AP11/FP11 slot according to the system configuration.
    *4
    PN-CP14 or PN-CP15 card is to be mounted in MP12/FP12 slot according to the system 
    configuration.
    *5
    PZ-8PFTB card is to be mounted in PFT slot.
    LT00-LT11  : Line/Trunk card mounting slots
    AP00-AP11 : Application Processor card
    mounting slots
    MP : PN-CP14 mounting slot
    FP : PN-CP15 mounting slotsVM : PZ-VM00-M mounting slot
    PFT : PZ-8PFTB mounting slot
    AC/DC PWR : PZ-PW121 mounting slot
    DC/DC PWR : PZ-PW122 mounting slot
    LT09/AP09LT08/AP08LT07/AP07
    LTC1LTC0LTC2
    BWB
    FRONT
    AC/DC
    PWR
    LT10/AP10LT00/AP00LT01/AP01LT02/AP02LT03/AP03LT04/AP04LT05/AP05LT06/AP06LT11/AP11/FP11MP12/FP12
    LTC3
    DC/DC
    PWR
    PFTVM
    *1*2*3*4*5 
    						
    							CHAPTER 1 GENERAL INFORMATION
    Circuit Card Mounting Slots
    NEAX2000 IVS2 Installation Procedure ManualPage 30ND-70928 (E), Issue 1.0
    
    Mountable slots according to the number of ports
    The PIM can mount 8-port circuit cards. 
    Available slots are defined by the number of ports of the circuit card.
    *
    In Slots 08-11, 8-port circuit cards are not mountable. The number of physical ports which 
    can be provided by Slots 08-11 depends on the number of ports of the circuit cards mounted 
    in Slots 04-07.
    MOUNTING CIRCUIT 
    CARDS IN SLOT 04-07MOUNTABLE CIRCUIT CARDS IN SLOT 08-11
    8-port circuit cards such
    as;
    PN-8COT, PN-8DLC, 
    PN-8LC, PN-8RSTA,
    PN-4DAT, PN-CFTB,
    PN-2CSI, PN-2ILCAny application processor cards
    Such as;
    PN-AP00-A, PN-AP00-B, PN-AP01, PN-BRTA, PN-2BRTC,
    PN-CC01, PN-24DTA-C, PN-30DTC-A, PN-IPTA, PN-M03,
    PN-24PRTA, PN-4RSTB, PN-4RSTC, PN-SC01, PN-SC02,
    PN-SC03, PN-SC03-A
    4-port circuit cards 4-port line/trunk cards or any application processor cards
    00 01
       02 03 04 05 06 07 08 09 10 11 12
    P 
    F 
    T V 
    M
    8-port circuit cards are mountable
    4-port circuit cards are mountableSee below.* 
    						
    							CHAPTER 1 GENERAL INFORMATION
    Control Card Mounting Conditions
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 31
    Control Card Mounting Conditions
    (1) PN-CP14 (MP)
    Mount the PN-CP14 card in the MP slot (Slot 12) of PIM0.
    (2) PN-CP15 (FP)
    When the system is configured with three PIMs or more, mount one PN-CP15 card in the 
    FP slot (PIM0: Slot 11, PIM2, 4, 6: Slot 12) of PIM0, PIM2, PIM4, and PIM6.
    When the system is configured with one or two PIMs, the PN-CP15 card needs not to be 
    mounted.
    NOTE:For the correct number of FPs per system, refer to the Business/Hotel/Data Features
    and Specifications manual.
    Figure 1-8  MP/FP Card Mounting Slots
    F 
    P 
    12
    F 
    P 
    11
    F 
    P 
    12
    F 
    P 
    12M 
    P 
    12PIM7
    PIM6
    PIM5
    PIM4 PIM3
    PIM2
    PIM1
    PIM0 
    						
    							CHAPTER 1 GENERAL INFORMATION
    Application Processor Card Mounting Conditions
    NEAX2000 IVS2 Installation Procedure ManualPage 32ND-70928 (E), Issue 1.0
    Application Processor Card Mounting Conditions
    (1) System Capacity for Application Processor Card
    Max. 24 cards per system
    Max. 256 ports per system
    (2) Mounting Application Processor Cards in PIM0
    Use slots AP00 to AP11 to mount application processor cards in PIM0.
    AP11 Slot (FP11 slot) of PIM0 is not available for application processor if the system is 
    configured with three or more PIMs, as this slot is used to mount FP card for that 
    configuration.
    Figure 1-9  Application Processor Card Mounting Slots (PIM0)
    *1Application processor cards can be mounted in AP00 to AP10 slots.
    *2AP11 slot is available for application processor cards only when the system is configured 
    with two or less PIMs.
    AP09AP08AP07
    LTC1LTC0LTC2
    BWB
    PIM 0
    FRONT
    AC/DC
    PWR
    AP10AP00AP01AP02AP03AP04AP05AP06AP11/FP11MP12
    LTC3
    DC/DC
    PWR
    PFTVM
    *2*1 
    						
    							CHAPTER 1 GENERAL INFORMATION
    Application Processor Card Mounting Conditions
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 33
    (3) Mounting Application Processor Cards in PIM1-7
    Use Slots AP00 to AP11 to mount application processor cards in PIM1 through 7.
    Figure 1-10  Application Processor Card Mounting Slots (PIM1-7)
    *1
    Application processor cards can be mounted in AP00 to AP11 slots.
    AP09AP08AP07
    LTC1LTC0LTC2
    BWB
    PIM
    1 - 7
    FRONTAC/DC
    PWR
    AP10AP00AP01AP02AP03AP04AP05AP06AP11FP12
    LTC3
    DC/DC
    PWR
    PFTVM
    *1 
    						
    							CHAPTER 1 GENERAL INFORMATION
    Application Processor Card Mounting Conditions
    NEAX2000 IVS2 Installation Procedure ManualPage 34ND-70928 (E), Issue 1.0
    (4) Mounting Conditions of Each Card
    CARD NAME MOUNTING CONDITIONS
    PN-PW00 No circuit card can be mounted in the adjoining left side slot
    because one card occupies two physical slots width.
    PN-CC01 Mount the PN-CC01 card in the slot that adjoins the PN-AP01
    card. Connect both cards using cable (48-TW-0.3 CONN CA).
    PN-BRTA
    PN-2BRTC
    PN-24DTA-C
    PN-30DTC-A
    PN-24PRTAMount at least one card in PIM0 to receive source clock signals.
    PZ-M542
    PZ-M557Mount the PZ-M542/PZ-M557 card into any LTC connector of
    PIM BWB.
    Max. two cards can be mounted per PIM as follows:
    LTC0 and LTC2
    LTC0 and LTC3
    LTC1 and LTC3 
    						
    All NEC manuals Comments (0)