NEC Neax 2000 Ivs2 Installation Procedure Manual
Have a look at the manual NEC Neax 2000 Ivs2 Installation Procedure Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CHAPTER 1 GENERAL INFORMATION Line/Trunk Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 25 PN-2ODTA ODT 2-line Out Band Dialling Trunk Card Used as either a 2-wire E&M trunk or a 4-wire E&M trunk. Equipped with –48V DC-DC on-board power supply. Both No. 0 and No. 1 circuits must be set to the same pur- pose (2-wire or 4-wire) in one card. PN-2ODTB [For N.Z.]ODT 2-line Out Band Dialling Trunk Card Used as either a 2-wire E&M trunk or a 4-wire E&M trunk. Equipped with –48V DC-DC on-board power supply. Both No. 0 and No. 1 circuits must be set to the same pur- pose (2-wire or 4-wire) in one card. PN-8RSTA PBR 8-line PB Receiver Card Used for a PB station line, DID or tie line. PN-TNTA TNT 2-line Tone/Music Source Interface Card Used for BGM or Music on Hold. Provides two jacks for an external tone/music source. PN-4VCTH VCT 4-channel CODEC Card for IP Trunk Voice compression protocols: G723.1, G729/G729A, G711, FAX (14.4 kbps), DTMF signals Used together with PN-IPTA card. PZ-8PFTB PFT 8-line Power Failure Transfer Card To be mounted in PFT slot of PIM. One card per PIM. PZ-VM00-M VM 4-port Voice Mail Card (NEAXMail AD-8) One card per system. Number of ports : four ports (Up to eight ports when PZ-VM01 is mounted) Occupies three physical slots width per card. To be mounted in LT00 slot of PIM. PZ-VM01 VM 4-port Voice Mail Extension Card To be mounted on PZ-VM00-M. Table 1-5 Line/Trunk Card Name and Function (Continued) EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION
CHAPTER 1 GENERAL INFORMATION Line Conditions of Each Terminal NEAX2000 IVS2 Installation Procedure ManualPage 26ND-70928 (E), Issue 1.0 LINE CONDITIONS OF EACH TERMINAL The cable length between the DLC card and terminal varies depending on the type of terminal. This table shows the line conditions of each D term, DSS/BLF Console, and Attendant Console. Table 1-6 Line Conditions of Each Terminal TERMINAL TYPE CARD TYPECABLE LENGTH* (Cable 0.5 φ/24 AWG)REMARKS Dterm75 (Series E) (8 button)PN-8DLCL/8DLCP (STANDARD)984 ft. (300 m)NOTE 1 PN-4DLCM/4DLCQ (STANDARD)984 ft. [3937 ft.(300 m) (1200 m)] PN-2DLCB/2DLCN (LONG)2788 ft. [3937 ft.(850 m) (1200 m)] D term75 (Series E) (16 button)PN-8DLCL/8DLCP (STANDARD)656 ft. (200 m)NOTE 1 PN-4DLCM/4DLCQ (STANDARD)656 ft. [3937 ft.(200 m) (1200 m)] PN-2DLCB/2DLCN (LONG)2788 ft. [3937 ft.(850 m) (1200 m)] D term75 (Series E) (32 button)PN-8DLCL/8DLCP (STANDARD)656 ft. (200 m)NOTE 1 PN-4DLCM/4DLCQ (STANDARD)656 ft. [3937 ft.(200 m) (1200 m)] PN-2DLCB/2DLCN (LONG)2788 ft. [3937 ft.(850 m) (1200 m)] * The value in brackets [ ] shows the cable length when local power is supplied.
CHAPTER 1 GENERAL INFORMATION Line Conditions of Each Terminal NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 27 Dterm65 (Series III) (8 button)PN-8DLCL/8DLCP (STANDARD)984 ft. (300 m)NOTE 1 PN-4DLCM/4DLCQ (STANDARD)984 ft. [3937 ft.(300 m) (1200 m)] PN-2DLCB/2DLCN (LONG)2788 ft. [3937 ft.(850 m) (1200 m)] D term65 (Series III) (24 button)PN-8DLCL/8DLCP (STANDARD)492 ft. (150 m)NOTE 1 PN-4DLCM/4DLCQ (STANDARD)492 ft. [3937 ft.(150 m) (1200 m)] PN-2DLCB/2DLCN (LONG)2788 ft. [3937 ft.(850 m) (1200 m)] DSS/BLF Console NOTE 2PN-8DLCL/8DLCP (STANDARD)984 ft. (300 m)NOTE 1 PN-4DLCM/4DLCQ (STANDARD)984 ft. (300 m) PN-2DLCB/2DLCN (LONG)2788 ft. (850 m) SN610 ATTCON (4-wire type ATTCON)PN-4DLCF (STANDARD) 984 ft. (300 m) PN-2DLCC (LONG)3937 ft. (1200 m) Table 1-6 Line Conditions of Each Terminal (Continued) TERMINAL TYPE CARD TYPECABLE LENGTH* (Cable 0.5 φ/24 AWG)REMARKS * The value in brackets [ ] shows the cable length when local power is supplied.
CHAPTER 1 GENERAL INFORMATION Line Conditions of Each Terminal NEAX2000 IVS2 Installation Procedure ManualPage 28ND-70928 (E), Issue 1.0 NOTE 1: When using PN-8DLCL or PN-8DLCP card, it is not available long line function, even if D term is equipped with Long Line Adapter. NOTE 2: The DSS/BLF Console requires local AC/DC power supply. SN708/709/712 ATTCON (2-wire type ATTCON)PN-8DLCL/8DLCP (STANDARD)984 ft. (300 m)NOTE 1 PN-4DLCM/4DLCQ (STANDARD)984 ft. [3937 ft.(300 m) (1200 m)] PN-2DLCB/2DLCN (LONG)2788 ft. [3937 ft.(850 m) (1200 m)] SN716 DESKCON PN-8DLCL/8DLCP and PN-PW00 or AC Adapter1000 ft. (304 m) PN-4DLCM/4DLCQ and PN-PW00 or AC Adapter1500 ft. (457 m) Table 1-6 Line Conditions of Each Terminal (Continued) TERMINAL TYPE CARD TYPECABLE LENGTH* (Cable 0.5 φ/24 AWG)REMARKS * The value in brackets [ ] shows the cable length when local power is supplied.
CHAPTER 1 GENERAL INFORMATION Mounting Conditions of Circuit Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 29 MOUNTING CONDITIONS OF CIRCUIT CARD This section explains the conditions for mounting circuit cards used in the system. Circuit Card Mounting Slots The figure below shows circuit card mounting slots allocated in the PIM based on circuit card type. Figure 1-7 Circuit Card Mounting Slots *1 PZ-VM00-M card is to be mounted in LT00 slot to use VM slot. *2 Either line/trunk cards or application processor cards can be mounted in LT00/AP00- LT10/AP10 slots. *3 Either PN-CP15 or a line/trunk card or an application processor card is to be mounted in LT11/AP11/FP11 slot according to the system configuration. *4 PN-CP14 or PN-CP15 card is to be mounted in MP12/FP12 slot according to the system configuration. *5 PZ-8PFTB card is to be mounted in PFT slot. LT00-LT11 : Line/Trunk card mounting slots AP00-AP11 : Application Processor card mounting slots MP : PN-CP14 mounting slot FP : PN-CP15 mounting slotsVM : PZ-VM00-M mounting slot PFT : PZ-8PFTB mounting slot AC/DC PWR : PZ-PW121 mounting slot DC/DC PWR : PZ-PW122 mounting slot LT09/AP09LT08/AP08LT07/AP07 LTC1LTC0LTC2 BWB FRONT AC/DC PWR LT10/AP10LT00/AP00LT01/AP01LT02/AP02LT03/AP03LT04/AP04LT05/AP05LT06/AP06LT11/AP11/FP11MP12/FP12 LTC3 DC/DC PWR PFTVM *1*2*3*4*5
CHAPTER 1 GENERAL INFORMATION Circuit Card Mounting Slots NEAX2000 IVS2 Installation Procedure ManualPage 30ND-70928 (E), Issue 1.0 Mountable slots according to the number of ports The PIM can mount 8-port circuit cards. Available slots are defined by the number of ports of the circuit card. * In Slots 08-11, 8-port circuit cards are not mountable. The number of physical ports which can be provided by Slots 08-11 depends on the number of ports of the circuit cards mounted in Slots 04-07. MOUNTING CIRCUIT CARDS IN SLOT 04-07MOUNTABLE CIRCUIT CARDS IN SLOT 08-11 8-port circuit cards such as; PN-8COT, PN-8DLC, PN-8LC, PN-8RSTA, PN-4DAT, PN-CFTB, PN-2CSI, PN-2ILCAny application processor cards Such as; PN-AP00-A, PN-AP00-B, PN-AP01, PN-BRTA, PN-2BRTC, PN-CC01, PN-24DTA-C, PN-30DTC-A, PN-IPTA, PN-M03, PN-24PRTA, PN-4RSTB, PN-4RSTC, PN-SC01, PN-SC02, PN-SC03, PN-SC03-A 4-port circuit cards 4-port line/trunk cards or any application processor cards 00 01 02 03 04 05 06 07 08 09 10 11 12 P F T V M 8-port circuit cards are mountable 4-port circuit cards are mountableSee below.*
CHAPTER 1 GENERAL INFORMATION Control Card Mounting Conditions NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 31 Control Card Mounting Conditions (1) PN-CP14 (MP) Mount the PN-CP14 card in the MP slot (Slot 12) of PIM0. (2) PN-CP15 (FP) When the system is configured with three PIMs or more, mount one PN-CP15 card in the FP slot (PIM0: Slot 11, PIM2, 4, 6: Slot 12) of PIM0, PIM2, PIM4, and PIM6. When the system is configured with one or two PIMs, the PN-CP15 card needs not to be mounted. NOTE:For the correct number of FPs per system, refer to the Business/Hotel/Data Features and Specifications manual. Figure 1-8 MP/FP Card Mounting Slots F P 12 F P 11 F P 12 F P 12M P 12PIM7 PIM6 PIM5 PIM4 PIM3 PIM2 PIM1 PIM0
CHAPTER 1 GENERAL INFORMATION Application Processor Card Mounting Conditions NEAX2000 IVS2 Installation Procedure ManualPage 32ND-70928 (E), Issue 1.0 Application Processor Card Mounting Conditions (1) System Capacity for Application Processor Card Max. 24 cards per system Max. 256 ports per system (2) Mounting Application Processor Cards in PIM0 Use slots AP00 to AP11 to mount application processor cards in PIM0. AP11 Slot (FP11 slot) of PIM0 is not available for application processor if the system is configured with three or more PIMs, as this slot is used to mount FP card for that configuration. Figure 1-9 Application Processor Card Mounting Slots (PIM0) *1Application processor cards can be mounted in AP00 to AP10 slots. *2AP11 slot is available for application processor cards only when the system is configured with two or less PIMs. AP09AP08AP07 LTC1LTC0LTC2 BWB PIM 0 FRONT AC/DC PWR AP10AP00AP01AP02AP03AP04AP05AP06AP11/FP11MP12 LTC3 DC/DC PWR PFTVM *2*1
CHAPTER 1 GENERAL INFORMATION Application Processor Card Mounting Conditions NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 33 (3) Mounting Application Processor Cards in PIM1-7 Use Slots AP00 to AP11 to mount application processor cards in PIM1 through 7. Figure 1-10 Application Processor Card Mounting Slots (PIM1-7) *1 Application processor cards can be mounted in AP00 to AP11 slots. AP09AP08AP07 LTC1LTC0LTC2 BWB PIM 1 - 7 FRONTAC/DC PWR AP10AP00AP01AP02AP03AP04AP05AP06AP11FP12 LTC3 DC/DC PWR PFTVM *1
CHAPTER 1 GENERAL INFORMATION Application Processor Card Mounting Conditions NEAX2000 IVS2 Installation Procedure ManualPage 34ND-70928 (E), Issue 1.0 (4) Mounting Conditions of Each Card CARD NAME MOUNTING CONDITIONS PN-PW00 No circuit card can be mounted in the adjoining left side slot because one card occupies two physical slots width. PN-CC01 Mount the PN-CC01 card in the slot that adjoins the PN-AP01 card. Connect both cards using cable (48-TW-0.3 CONN CA). PN-BRTA PN-2BRTC PN-24DTA-C PN-30DTC-A PN-24PRTAMount at least one card in PIM0 to receive source clock signals. PZ-M542 PZ-M557Mount the PZ-M542/PZ-M557 card into any LTC connector of PIM BWB. Max. two cards can be mounted per PIM as follows: LTC0 and LTC2 LTC0 and LTC3 LTC1 and LTC3