    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-24PRTA (PRT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 295
    Lamp Indications
    Switch Settings
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    LC Green Remains lit when communications are normally ongoing with the 
    D channel data links connected.
    LPB–Not used
    CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) 
    errors.
    PCM Red Remains lit when detecting PCM signal loss.
    FRM Red Remains lit when detecting Frame Alignment signal loss.
    RMT Red Remains lit when receiving Frame Alignment signal loss alarm 
    from a distant office.
    AIS Red Remains lit when a pattern of consecutive “1” is received. 
    The distant office transmits this signal for a loop-back test.
    BL Red B channel status
    ON : More than 10 channels are busy
    OFF : All channels are idle
    Flash (60 IPM) : Only one channel is busy
    Flash (120 IPM) : 2 through 10 channels are busy
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 10-3 Not used
    4-F Set the switch to match the AP Number (04-31) to
    be set by CM05.
    (Continued)
    F
    4
    AP No.SW1-4: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW1-4: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-24PRTA (PRT)
    NEAX2000 IVS2 Installation Procedure ManualPage 296ND-70928 (E), Issue 1.0
    MB (Toggle SW)
    NOTE 2UP For make-busy
    For normal operation
    SW0
    (Piano Key SW)
    1
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO 0 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO 0 input on MP 
    card. 
    2 
    NOTE 3
    NOTE 4ONSource clock signal from network is 
    sent to the PLO 1 input on MP card.
    OFFSource clock signal from network is 
    not sent to the PLO 1 input on MP 
    card. 
    3ONRemote loop-back
    For normal operation
    4ONLocal loop-back (AIS send)
    For normal operation
    5Set equalizer according to the cable 
    length between the PBX and the 
    MDF. OFF
    6
    OFF
    7
    OFF
    8 Not used
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    ON
    DOWN
    OFF
    ON
    5 6 7 8
    1 2 3 4
    OFF
    OFF
    ON
    OFF
    80-120m (262.5-394ft.)
    SW0-5 SW0-6 SW0-7CABLE LENGTH
    ON ON0-40m (0-131.2ft.)
    40-80m (131.2-262.5ft.)
    120-160m (394-525ft.)
    160-200m (525-656ft.)
    Signal is not sent ON ON ON
    ON ON OFF
    OFF ON OFF
    ON OFF ON
    OFF OFF OFF
    ON
    ON
    OFF 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-24PRTA (PRT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 297
    SW1
    (Piano Key SW)
    NOTE 41 Not used
    2 Not used
    3 Not used
    4ON AP No. 04-15
    OFF AP No. 20-31
    SW2 (DIP SW) 1
    Always set to OFF
    2[North America only for AT&T]
    ONDeletion of Area Code on 
    International Outgoing call
    OFFNo deletion of Area Code on 
    International Outgoing call
    [Australia/Other countries]
    Always set to OFF
    3 Always set to OFF
    4 Always set to OFF
    5 Always set to OFF
    6 Always set to OFF
    7 Always set to OFF
    8 Always set to OFF
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF
    1
    23
    45
    67
    8OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-24PRTA (PRT)
    NEAX2000 IVS2 Installation Procedure ManualPage 298ND-70928 (E), Issue 1.0
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and   , the setting of the switch varies with the system concerned.
    NOTE 1:
    Set the groove on the switch to the desired position.
    NOTE 2:
    When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
    ging the circuit card. JPR0 (Jumper pin)
    UPNeutral grounding on the receiving
    line is provided.
    Neutral grounding on the receiving
    line is not provided.
    JPR1 (Jumper pin)
    Line impedance: 100 ohms
    Left Line impedance: 110 ohms
    JPS (Jumper pin)
    UPNeutral grounding on the transmit-
    ting line is provided.
    Neutral grounding on the transmit-
    ting line is not provided.
    MAS (Jumper pin)
    UP Clock Source
    Clock Receiver
    AISS (Jumper pin)
    AIS signal is sent out when make-
    busy or power on.
    DOWNAIS signal is not sent out when 
    make-busy or power on.
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    DOWN
    Right
    DOWN
    DOWN
    UP 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-24PRTA (PRT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 299
    NOTE 3:
    Set SW0-1 and SW0-2 as follows:
    NOTE 4:
    When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the PRT cards
    mounted in PIM0 to “OFF”.
    NOTE 5:
    Mount the PRT card which receives a source clock signal into PIM 0.
    CONDITIONSPRT0 PRT1 PRT2 PRT3 PRT4
    REMARKS
    SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2SW
    0-1SW
    0-2
    When one PRT 
    is provided.ON OFF––––––––MP card will receive the 
    clock signal from PRT0 
    at its PLO0 input.
    When more 
    than one PRT 
    is provided.ON OFF OFF ON OFF OFF OFF OFF OFF OFFMP card will receive the 
    clock signal from PRT0 
    at its PLO0 input, under 
    normal conditions.
    Should a clock failure 
    occur with PRT0, MP 
    card will automatically 
    switch to the PLO1 
    input which gets clock 
    from PRT1. 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-4RSTB (MFR)
    NEAX2000 IVS2 Installation Procedure ManualPage 300ND-70928 (E), Issue 1.0
    PN-4RSTB (MFR)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    OPE0-3 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    SENSE
    RUN
    MB
    OPE3 
    OPE2 
    OPE1 
    OPE0 SW 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-4RSTB (MFR)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 301
    Switch Settings
    NOTE 1:
    Set the groove on the switch to the desired position.
    NOTE 2:
    When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
    ging the circuit card.
    SWITCH NAMESWITCH 
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 14-F Set the switch to match the AP Number (04-31) to
    be set by CM05
    0-3 Not used
    MB (Toggle SW)
    NOTE 2UP For make-busy
    For normal operation
    SW
    (Piano Key SW)1ON For make-busy No. 0 circuit
    For normal operation
    2ON For make-busy No. 1 circuit
    For normal operation
    3ON For make-busy No. 2 circuit
    For normal operation
    4ON For make-busy No. 3 circuit
    For normal operation
    5
    Not used 6
    7
    8ON AP No. 04-15
    OFF AP No. 20-31
    F
    4AP No.SW-8: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW-8: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF
    ON
    DOWN
    OFF
    ON
    5 6 7 8
    1 2 3
    4
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-4RSTC (CIR)
    NEAX2000 IVS2 Installation Procedure ManualPage 302ND-70928 (E), Issue 1.0
    PN-4RSTC (CIR)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    BL0-3 Red Remains lit when receiving a CALLER ID (CLASS SM) signal.
    SENSE
    RUN
    MB
    BL3 
    BL2 
    BL1 
    BL0 SW1
    JP0 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-4RSTC (CIR)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 303
    Switch Settings
    NOTE 1:
    Set the groove on the switch to the desired position.
    NOTE 2:
    When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
    ging the circuit card.
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 14-F Set the switch to match the AP Number (04-15) to
    be set by CM05.
    0-3 Not used
    MB (Toggle SW)
    NOTE 2UP For make-busy
    For normal operation
    SW1 
    (Piano Key SW)1ON For make-busy No. 0 circuit
    For normal operation
    2ON For make-busy No. 1 circuit
    For normal operation
    3ON For make-busy No. 2 circuit
    For normal operation
    4ON For make-busy No. 3 circuit
    For normal operation
    JP0
    For normal operation
    F
    4AP No.04 05 06 07 08 09 10 11 12 13 14 15
    SW No.456789ABCDEF
    ON
    DOWN
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF
    OFF
    (
    Jumper pin)RIGHT 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-SC00 (CCH)
    NEAX2000 IVS2 Installation Procedure ManualPage 304ND-70928 (E), Issue 1.0
    PN-SC00 (CCH)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    LC Green Remains lit when communications are normally ongoing with the 
    common signalling channel data links connected.
    LPB Green Remains lit when a loop-back test is in progress.
    RS
    SENSE
    RUN
    MB
    SW0
    LC
    LPB SW1
    TO  M O D E M  
    ( FOR ANALOG INTERFACE) 
    						