CHAPTER 1 GENERAL INFORMATION Control Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 15 Control Card This table shows the names and functions of each control card. Table 1-3 Control Card Name and Function EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION PN-CP14 MP Main Processor Card Provides Memory, TDSW (1024CH x 1024CH), 16-line CFT, PB sender, Clock, PLO 2 ports (receiver mode/source mode), two RS-232C ports, 2-line DAT (Recording duration: Max. 128sec.), DK, 4-line PB receiver, Modem for remote maintenance (19.2 kbps), internal Music-on-Hold tone source and BUS interface. BUS interface functions as a driver/receiver of various signals, adjusts gate delay timing and cable delay timing, monitors I/O Bus and PCM BUS. One card is required per system. PN-CP15 FP Firmware Processor Card Provides Line/Trunk interface, Memory (RAM 768KB), and inter-module BUS interface. BUS interface functions as a driver/receiver of various signals, adjusts gate delay timing and cable delay timing, monitors I/O Bus and PCM BUS. When the system consists of three PIMs or more, one each of this card is mounted respectively in PIM0, PIM2, PIM4, and PIM6. PN-PW00 EXTPWR Power Supply Card for DESKCON Provides –48V DC power. Max. four cards per frame (four PIMs). Max. three cards per PIM. Occupies two physical slots width per card. PZ-PW121 AC/DC PWR Main Power Supply Card Input: AC120V/240V (50Hz/60Hz) Output:–27V (4.4A), +5V (7.2A), CR (38mA), +90V (80mA) One card is pre-installed per PIM. PZ-PW122 DC/DC PWR Power Supply Card for Cell Station (Zone Transceiver) Input:–24V DC Output:–48V DC (1.7A) One card per PIM. Max. 16 CS (ZT)s backed up by one card.
CHAPTER 1 GENERAL INFORMATION Application Processor Card NEAX2000 IVS2 Installation Procedure ManualPage 16ND-70928 (E), Issue 1.0 Application Processor Card This table shows the names and functions of each application processor card. Table 1-4 Application Processor Card Name and Function EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION PN-AP00-A [For North America/ Latin America Only]DBM Data Base Module Card for WCS Roaming function One card per WCS system. PN-AP00-B AP00 Application Processor Card Provides four RS-232C ports and is used for SMDR, Hotel Printer, CIS, PMS, MCI, CS report functions. One card per system. PN-AP01 AP01 Application Processor Card Provides one RS-232C port and one Ethernet interface port. Used for OAI function, ID code expansion. One card per system. PN-BRTA BRT 1-line Basic Rate (2B+D) Interface Trunk Card Accomodates one 2-channel PCM digital lines. PN-2BRTC BRT 2-line Basic Rate (2B+D) Interface Trunk Card Accomodates two 2-channel PCM digital lines. PN-CC01 ETHER Ethernet Control Card Used with the PN-AP01 card to accommodate the Ethernet and transmit/receive a signal of TCP/IP protocol. 10 BASE-T twisted pair cable is connected directly to this card.
CHAPTER 1 GENERAL INFORMATION Application Processor Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 17 PN-DAIA DAI Digital Trunk Interface (23B+D, 1.5 Mbps) Card for Remote PIM Accomodates 24-channel PCM digital lines, and provides Firmware Processor and BUS interface. One through three cards, corresponding to the number of remote site, must be provided at main site. PN-DAIB DAI Digital Trunk Interface (23B+D, 1.5 Mbps) Card for Remote PIM Accomodates 24-channel PCM digital lines, and provides Firmware Processor. One card is required per Remote PIM at remote site. PN-DAIC DAI Digital Trunk Interface (23B+D, 1.5 Mbps) Channel Expansion Card Accomodates 24-channel PCM digital lines. One through six cards can be provided at main site. Two cards can be provided at remote site. PN-DAID DAI Digital Trunk Interface (2 Mbps) Card for Remote PIM Accomodates 30-channel PCM digital lines, and provides Firmware Processor and BUS interface. One through three cards, corresponding to the number of remote site, must be provided at main site. PN-DAIE DAI Digital Trunk Interface (2 Mbps) Card for Remote PIM Accomodates 30-channel PCM digital lines, and provides Firmware Processor. One card is required per Remote PIM at remote site. PN-DAIF DAI Digital Trunk Interface (2 Mbps) Channel Expansion Card Accomodates 30-channel PCM digital lines. One through three cards can be provided at main site. One card can be provided at remote site. PN-24DTA-C DTI Digital Trunk Interface (23B+D, 1.5 Mbps) Card Accommodates 24-channel PCM digital lines. PN-30DTC-A DTI Digital Trunk Interface (2 Mbps) Card Accommodates 30-channel PCM digital lines. Table 1-4 Application Processor Card Name and Function (Continued) EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION
CHAPTER 1 GENERAL INFORMATION Application Processor Card NEAX2000 IVS2 Installation Procedure ManualPage 18ND-70928 (E), Issue 1.0 PN-IPTA IPT IP Trunk Card Accommodates the IP network and transmit/receive com- pressed voice or signals over IP network. Used with max. four PN-4VCTH cards (16 channels). 10 BASE-T/100 BASE-TX twisted pair cable is connected directly to this card. PN-24PRTA PRT ISDN Primary Rate (23B+D) Interface Card Provides a built-in D-channel Handler (DCH). PN-4RSTB MFR 4-line MF Receiver, MFC Receiver/Sender Card Used for MF/MFC-R2 Signaling on DID/DOD trunks. Max. four cards can be provided per system, including the PN-4RSTC card. PN-4RSTC CIR 4-line Caller ID Receiver Trunk Card Used for Caller ID (CLASS SM) on analog trunks. Max. four cards per system, including the PN-4RSTB card. PN-SC00 CCH Common Channel Handler Card Transmits/receives signals on the common signalling channel of No. 7 CCIS. PN-SC01 DCH D-channel Handler Card Transmits/receives signals on the D-channel of ISDN Primary Rate (23B+D) interface or WCS Roaming interface. PN-SC03 ICH ISDN-channel Handler Card Provides the D-channel signaling interface and controls max. four ILC cards (Layer 2 and 3). PN-SC03-A CSH CS(ZT) Handler Card Provides the D-channel signaling interface and controls max. four CSI cards, eight CS(ZT)s. Table 1-4 Application Processor Card Name and Function (Continued) EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION
CHAPTER 1 GENERAL INFORMATION Application Processor Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 19 PZ-M537 EXPMEM Memory Expansion Card for MP/AP00 Card The system capacity is expanded as follows: When mounted on PN-CP14 (MP) card: When mounted on PN-AP00-B (AP00) card: PZ-M542 [For Other Countries]CONN Coaxial Cable Connection Card Used to connect a coaxial cable for Digital Trunk Interface. Max. two cards can be connected to LTC connector of each PIM. PZ-M557 [For Australia]CONN Coaxial Cable Connection Card Used to connect a coaxial cable for Digital Trunk Interface. Max. two cards can be connected to LTC connector of each PIM. Table 1-4 Application Processor Card Name and Function (Continued) EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION System Capacity w/o EXPMEM with EXPMEM Line/Trunk 384 768 DID dial conversion 500 1000 IP trunk 1 4 Analog Station 256 512 D term256 512 Analog Station+D term256 512 Analog Station+D term+PS256 512 D term (24/32 button)256 512 PS 128 256 ISDN terminal 64 128 Data station 64 128 Call Forwarding-Outside set 240 496 Authorization Code/ Forced Account Code/ Remote Access to System (DISA) Code1000 3000 Message Remider set 512 1024 Name Display/ Guest Name Display256 512 Speed Calling-Station (Station Speed Dial) set4000 10000 MP built-in SMDR call record 256 1280 System Capacity w/o EXPMEM with EXPMEM SMDR call record 1600 27000
CHAPTER 1 GENERAL INFORMATION Line/Trunk Card NEAX2000 IVS2 Installation Procedure ManualPage 20ND-70928 (E), Issue 1.0 Line/Trunk Card This table shows the names and functions of each line/trunk card. Table 1-5 Line/Trunk Card Name and Function EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION PN-2AMPA AMP 2-line Amplifier Trunk Card Provides Echo Canceller (EC), Automatic Gain Controller (AGC) and Tone Disabler (TD) functions. PN-AUCA AUC 2-line Analog Long Line Circuit Card provided with Power Failure Transfer (PFT) Function, or 2-line Direct Inward Dialing Trunk Card Line resistance in the case of a long line circuit: Max. 2500 ohms (inclusive of the internal resistance of the distant office equipment) Equipped with –48V DC-DC on-board power supply. PN-CFTA CFT 6/10 Party Conference Trunk Card Use of one card: Can control a conference of up to six participants. Use of two cards: Can control a conference of up to ten participants. PN-CFTB CFT 6 Party Conference Trunk Card One card can control a conference of up to ten par ticipants. Occupies 8 time slots per one card. PN-2COTD [For Austra- lia/Others]COT 2-line Central Office Trunk Card (Loop Start Trunk) Provides metering pulse detection function. PN-4COTA-A COT 4-line Central Office Trunk Card (Loop Start Trunk) PN-4COTB COT 4-line Central Office Trunk Card (Ground Start Trunk) Provides loop detection, sending/detecting ground on Tip/ Ring wire. PN-4COTF [For N.Z.]COT 4-line Central Office Trunk Card (Loop Start/Ground Start Tr u n k ) Provides loop holding, pulse sender, and a detector for ground signals.
CHAPTER 1 GENERAL INFORMATION Line/Trunk Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 21 PN-4COTE [For Australia]COT 4-line Central Office Trunk Card (Loop Start Trunk) Provides a detector for line fault conditions. PN-4COTG COT 4-line Central Office Trunk Card (Loop Start trunk) Provides loop detection, receiving/sending the Caller ID (CLASS SM) signal. PN-6COTJ [For Australia]COT 6-line Central Office Trunk Card (Loop Start Trunk) Provides a detector for line fault conditions. PN-8COTR COT 8-line Central Office Trunk Card (Loop Start Trunk) PN-8COTS COT 8-line Central Office Trunk Card (Ground Start Trunk) Provides loop detection, sending/detecting ground on Tip/ Ring wire. PN-8COTT [For Australia]COT 8-line Central Office Trunk Card (Loop Start Trunk) Provides a detector for line fault conditions. PN-8COTQ COT 8-line Central Office Trunk Card (Loop Start Trunk) Provides loop detection, receiving/sending the Caller ID (CLASS SM) signal. PN-2CSIA [For North America/ Latin America]CSI 2-line Zone Transceiver Interface Card Used to interface with the ZT, based on ISDN S-interface. Max. two ZTs can be connected per CSI card. Occupies eight time slots per one card. PN-2CSIA-A [For Austra- lia/Others]CSI 2-line Cell Station Interface Card Used to interface with the CS, based on ISDN S-interface. Max. two CSs can be connected per one card. Occupies eight time slots per one card. PN-4DATC DAT 4-line Digital Announcement Trunk Card Recording duration: Max. 120 seconds Occupies eight time slots per one card. Table 1-5 Line/Trunk Card Name and Function (Continued) EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION
CHAPTER 1 GENERAL INFORMATION Line/Trunk Card NEAX2000 IVS2 Installation Procedure ManualPage 22ND-70928 (E), Issue 1.0 PN-2DITA [For Hong Kong]DIT 2-line Direct Inward Dialing Trunk Card Provides loop detection, sending reverse signal and PB to DP signal conversion. Equipped with –48V DC-DC on-board power supply. PN-4DITB DIT 4-line Direct Inward Dialing Trunk Card Provides loop detection, sending reverse signal and PB to DP signal conversion. Equipped with –48V DC-DC on-board power supply. PN-DK00 DK 8-circuit External Relay Control/External Key Scan Card Provides the above-mentioned control functions on a per cir- cuit basis. PN-2DLCB/ PN-2DLCNDLC 2-line Digital Long Line Circuit Card for D term75/65 (Series E/ III), D term70/60 (Elite/Electra Pro), DSS Console, ATTCON [–48V version, 2-wire type] Equipped with –48V DC-DC on-board power supply. PN-2DLCC DLC 2-line Digital Long Line Circuit Card for SN610 ATTCON [–48V version, 4-wire type] Equipped with –48V DC-DC on-board power supply. PN-4DLCF DLC 4-line Digital Line Circuit Card for SN610 ATTCON [–27V version, 4-wire type] PN-4DLCM DLC 4-line Digital Line Circuit Card for D term75/65 (Series E/III), D term70/60 (Elite/Electra Pro), DSS Console, ATTCON, DESKCON [–27V version, 2-wire type] PN-4DLCQ DLC 4-line Digital Line Circuit Card for D term75/65(Series E/III), DSS Console, ATTCON, DESKCON [–27V version, 2-wire type] PN-8DLCL DLC 8-line Digital Line Circuit Card for D term75/65 (Series E/III), D term70/60 (Elite/Electra Pro), DSS Console, ATTCON, DESKCON [–27V version, 2-wire type] Table 1-5 Line/Trunk Card Name and Function (Continued) EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION
CHAPTER 1 GENERAL INFORMATION Line/Trunk Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 23 PN-8DLCP DLC 8-line Digital Line Circuit Card for Dterm75/65 (Series E/III), DSS Console, ATTCON, DESKCON [–27V version, 2-wire type] PN-2DPCB DPC 2-line Data Port Controller Card Used for intra-office or inter-office digital data transmission on nailed down connection. Accommodates max. two DTEs with V.11 (X.21) interface or V.24/V.28 (RS-232C) interface. PN-2ILCA ILC 2-line ISDN Line Circuit Card Provides a physical interface to ISDN Terminals. Occupies eight time slots per one card. PN-4LCC [For Others]LC 4-line Analog Line Circuit Card for Single Line Telephones Loop resistance: Max. 600 ohms (including telephone set) PN-4LCD-A LC 4-Line Analog Line Circuit Card for Single Line Telephones Loop resistance : Max. 600 ohms (including telephone set) Provides momentary open and Message Waiting Lamp control functions for each circuit. Equipped with +80V DC-DC on-board power supply. PN-4LCE [For Australia]LC 4-line Analog Line Circuit Card for Single Line Telephones Loop resistance: Max. 600 ohms (including telephone set) PN-4LCF [For Australia]LC 4-line Analog Line Circuit Card for Single Line Telephones Loop resistance: Max. 600 ohms (including telephone set) Provides Message Waiting Lamp control function for each circuit, and reverse function for only No. 3 circuit. Equipped with +80V DC-DC on-board power supply. PN-4LCK [For China]LC 4-Line Analog Line Circuit Card for Single Line Telephones Loop resistance : Max. 600 ohms (including telephone set) Table 1-5 Line/Trunk Card Name and Function (Continued) EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION
CHAPTER 1 GENERAL INFORMATION Line/Trunk Card NEAX2000 IVS2 Installation Procedure ManualPage 24ND-70928 (E), Issue 1.0 PN-4LCL [For China]LC 4-line Analog Line Circuit Card for Single Line Telephones Loop resistance : Max. 600 ohms (including telephone set) Provides Message Waiting Lamp control function for each circuit, and reverse function for only No. 3 circuit. Equipped with +80V DC-DC on-board power supply. PN-4LCV [For Brazil]LC 4-Line Analog Line Circuit Card for Single Line Telephones Loop resistance : Max. 600 ohms (including telephone set) PN-4LCW [For Brazil]LC 4-line Analog Line Circuit Card for Single Line Telephones Loop resistance : Max. 600 ohms (including telephone set) Provides Message Waiting Lamp control function for each circuit, and reverse function for only No. 3 circuit. Equipped with +80V DC-DC on-board power supply. PN-8LCAA LC 8-line Analog Line Circuit Card for Single Line Telephones Loop resistance : Max. 600 ohms (including telephone set) Provides Message Waiting Lamp control, momentary open functions for each circuit. PN-2LDTA [For Australia/Oth- ers]LDT 2-line Loop Dial Trunk Card Line resistance: Max. 2500 ohms (including internal resis- tance of the distant office equipment) Equipped with –48V DC-DC on-board power supply. PN-M03 M03 V.35 Data Terminal Equipment Interface Card Used together with the PN-2DPCB card to provide the V.35 interface. PN-M10 M10 Optical Interface Card Provides internal optical modem to T1/E1 network or Remote PIM. Line length : 10 km or less Line coding : CMI Table 1-5 Line/Trunk Card Name and Function (Continued) EQUIPMENT NAMEFUNCTIONAL NAMEFUNCTION