Home > NEC > Communications System > NEC Neax 2000 Ivs2 Installation Procedure Manual

NEC Neax 2000 Ivs2 Installation Procedure Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2000 Ivs2 Installation Procedure Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 416
    							CHAPTER 2 INSTALLATION
    Connection of DC Power Cable
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 85
    Connection of DC Power Cable
    (1) Confirm the connection of power output cables, as shown below (These cables are pre-
    installed).
    (2) For PIM0, connect the PWR CNT CA-E to the CN103 connector on the PZ-PW121 card and 
    the PWR1 connector on the BWB.
    For PIM1 to PIM7, connect the PWR CNT CA-D to the CN103 connector on the PZ-PW121 
    card and the PWR1 connector on the BWB.
    Figure 2-29  PWR CNT CA-D/PWR CNT CA-E
    Figure 2-30  Cable Connection between PZ-PW121 and BWB
    550 mm (21.7 inch)300 mm (11.8 inch) 250 mm (9.8 inch)
    PWR CNT CA-E  (FOR PIM0) 
    PWR CNT CA-D (FOR PIM1 TO PIM7)PWR0B PWR1 PZ-PW121 BWB (BACK WIRING BOARD)PIM
    PWR0CPWR0A
    POWER OUTPUT CABLE (+90V, CR, E)POWER OUTPUT CABLE (+5V, -27V, E)CARD SLOT AREA
    LTC CONNECTOR AREA
    CN103 
    						
    							CHAPTER 2 INSTALLATION
    Connection of DC Power Cable
    NEAX2000 IVS2 Installation Procedure ManualPage 86ND-70928 (E), Issue 1.0
    (3) When you need a –48V DC power supply installed for a Cell Station (Zone Transceiver) in 
    WCS system, do the following procedure. If not, skip this procedure and go to item (4) on 
    Page 88
    .
    STEP 1: Attach four screws preliminary to the PZ-PW122 card.
    STEP 2: Mount the PZ-PW122 card into the PIM which accommodates the CSI cards, and fas-
    ten the screws.
    NOTE:
    Screws are attached to the PZ-PW122 card.
    Figure 2-31  Mounting PZ-PW122 into PIM
    PIM
    PZ-PW122 
    						
    							CHAPTER 2 INSTALLATION
    Connection of DC Power Cable
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 87
    STEP 3:  Connect the PWR CNT CA-E or PWR CNT CA-D, and POWER OUTPUT CABLE 
    (–48V, E) as shown below.
    Figure 2-32  Cable Connection between PZ-PW121/PZ-PW122 and BWB
    PWR CNT CA-E  (FOR PIM0) 
    PWR CNT CA-D (FOR PIM1 TO PIM7)PWR0B PWR1 PZ-PW121 BWB (BACK WIRING BOARD)PIM
    PWR0CPWR0A
    POWER OUTPUT CABLE (+90V, CR, E) PZ-PW122
    POWER OUTPUT CABLE (+5V, -27V, E)
    POWER OUTPUT CABLE (-48V, E)CARD SLOT AREA
    LTC CONNECTOR AREA
    CN103 
    						
    							CHAPTER 2 INSTALLATION
    Connection of DC Power Cable
    NEAX2000 IVS2 Installation Procedure ManualPage 88ND-70928 (E), Issue 1.0
    (4) When the system is configured with two or more PIMs, connect the PZ-PW121 cards to 
    each other using the PWR CA-A for power multi-connection.
    Figure 2-33  PWR CA-A
    Figure 2-34  Connection of PWR CA-A Cables
    (a) When using an Internal Battery
    550 mm (21. 7inch)
    PWR CA-A
    PIM3
    TO INTERNAL 
    BATTERY PWR
    PWR 
    CA-A
    PIM2
    PIM1PIM7
    PIM6
    PIM5
    PIM4 PIM0
    TO INTERNAL 
    BATTERY PWR
    TO INTERNAL 
    BATTERY PWR
    PWR 
    CA-A
    TO INTERNAL 
    BATTERY PWR
    TO INTERNAL 
    BATTERY PWR
    PWR 
    CA-A
    TO INTERNAL 
    BATTERY PWR
    TO INTERNAL 
    BATTERY PWR
    PWR 
    CA-A
    TO INTERNAL 
    BATTERY PWR 
    						
    							CHAPTER 2 INSTALLATION
    Connection of DC Power Cable
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 89
    Figure 2-35  Connection of PWR CA-A Cables
    (b) When using an External Battery
    PIM 3PWR
    PIM 2
    PIM 1PIM 7
    PIM 6
    PIM 5
    PIM 4 PIM 0
    PWR
    PWRPWR 
    CA-A
    PWR
    PWR
    PWR
    PWR
    PWR
    PWR 
    CA-A
    TO EXTERNAL BATTERY 
    						
    							CHAPTER 2 INSTALLATION
    Supply Voltage Check And Heat Run Test
    NEAX2000 IVS2 Installation Procedure ManualPage 90ND-70928 (E), Issue 1.0
    SUPPLY VOLTAGE CHECK AND HEAT RUN TEST
    Precautions
    (1) Check the switch position of each PZ-PW121 card before turning power on.
    Make sure that the AC120V/240V selector switch is positioned to appropriate voltage for 
    each country (AC120V or AC240V).
    Make sure that the battery mode selector switch is positioned as shown below to meet the 
    kind of battery:
    (2) When the operating power is being supplied to the PZ-PW121 card, do not plug/unplug this 
    circuit card into/from its mounting slot.
    (3) Immediately follow the instructions below if the MJ lamp on the PZ-PW121 lights up or 
    smoke or an unpleasant odor is produced during the test: 
    a) Turn power off of all PZ-PW121 cards.
    b) Unplug the AC code from the wall outlet.
    c) Carefully check for cause(s) of the failure occurring. 
    NOTE:
    Do not turn power on again until the cause is detected. 
    (4) When the system is configured with two or more PIMs, the BUS cable is providing gang 
    control for the PZ-PW121 card of PIM0 and other PIMs. Therefore, if the power of PIM0 is 
    off, no power is supplied to the whole system even when the power switch(es) of other PIMs 
    are left on. Note, however, that the battery charging is continuing even under these 
    circumstances.
    SW
    240V 100V/120V
    ON OFF
    12
    SW101
    1 : Not used 
    2 : ON   (SEAL/FLOAT2) 
         OFF (OPEN/FLOAT1) 
      
    						
    							CHAPTER 2 INSTALLATION
    Power Routing
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 91
    Power Routing
    NOTE 1:PN-4LCD/4LCF/4LCL/4LCW card provides +80V on-board power supply (+80VOBP).
    NOTE 2:PN-AUCA, PN-2DLCB/PN-2DLCN, PN-2DLCC, PN-2LDTA, PN-2ODTA/2ODTB card
    provides –48V on-board power supply (–48VOBP).
    +5V
    -27V
    Ð27V
    CR
    +90V
    +90V AC
    AC PZ-PW121
    +5V
    -5V
    -5V +5V
    +80V
    -27V-27V
    -27V
    CR
    CR
    PZ-PW121
    NOTE 1
    +80VOBP
    +5V
    -48V
    -27V
    CR-48VOBP
    NOTE 2
    BATTERY PWR CA-A
    AC CORD-B
    TERMINAL 
    BLOCKSBASE PIM0 PIM1 TO  P I M 2
    +5V
    -27V
    -5V
    CR
    PN-8LCAA
    +90V
    TO AC MAINS INPUTAC CORD-D 
    						
    							CHAPTER 2 INSTALLATION
    Checking for Supply Voltage
    NEAX2000 IVS2 Installation Procedure ManualPage 92ND-70928 (E), Issue 1.0
    Checking for Supply Voltage
    Heat Run Test
    Turn the SW1 switch ON. Keep it on for 5 minutes to check for no abnormal voltage. After com-
    pleting the test, turn OFF the SW1 switch of the PZ-PW121 card on PIM0. Then, turn OFF the
    SW1 switches of all the PZ-PW121 cards.
    Before connecting AC Cord, verify:
    - that the SW1 switch of the PZ-PW121 card is positioned to OFF;
    - that the AC Cord is unplugged from the wall outlet.
    Use a tester to verify that the input power is AC120±10V or AC240±10V.
    Plug the AC cord into a wall outlet.
    Turn the SW1 switches of all the PZ-PW121 cards on PIM1 to PIM7 to 
    ON. Then, turn the SW1 switch of the PZ-PW121 card on PIM0 to ON 
    last of all.
    Verify that the ON lamp on the PZ-PW121 card lights up.
    Measure the output voltage: -20V should be observed at GND and -27V 
    terminals of the PZ-PW121 card. See Figure 2-36.
    Start 
    Checking power cable
    Connecting AC power
    Turning power ON
    Verifying power
    Testing for
    Testing for input power
    End and
    grounding conductor
    pilot lamp ON
    output voltage 
    						
    							CHAPTER 2 INSTALLATION
    Heat Run Test
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 93
    Figure 2-36  Confirming Output Voltage
    TESTER
    DC100V
    MJ
    MN
    ON
    -27V
    FG
    GND
    I O
    SW1
    TO         FRAME GROUND 
    TERMINAL IN PIM
    TO TERMINAL 
    BLOCK ON BASE 
    						
    							CHAPTER 2 INSTALLATION
    Battery Connection
    NEAX2000 IVS2 Installation Procedure ManualPage 94ND-70928 (E), Issue 1.0
    BATTERY CONNECTION
    WAR NIN G
    TURN OFF AC POWER BEFORE CONNECTING BATTERIES.
    CAU TIO N
    1. 24V batteries must be used in this system. 
    2. If battery terminals (+,  –) come in contact with the module while connecting the battery cable
    to the PZ-PW121 card, the PZ-PW121 card or the BWB may be broken. Therefore, you must
    perform work in accordance with the following steps when mounting or removing the batter-
    ies.
    (1) When mounting batteries: (a) Connect the battery cable to the batteries.
    (b) Mount the batteries into the appointed position of the PIM or the BATTM. 
    (c) Connect the battery cable to the PZ-PW121 card.
    (2) When removing batteries: (a) Disconnect the battery cable from the PZ-PW121 card. 
    (b) Remove the batteries from the PIM or the BATTM.
    Recommended Battery Internal Battery: YUASA MATSUSHITAtype NPH-3.2-12 
    type LCR-12V3.4NE
    External Battery: 
    (BATTM) YUASA
    MATSUSHITAtype NP-24-12B
    type LCL-12V-24 
    						
    All NEC manuals Comments (0)