CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-CP15 (FP) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 215 PN-CP15 (FP) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while the circuit card is operating normally. SENSE RUN MB SW1
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-CP15 (FP) NEAX2000 IVS2 Installation Procedure ManualPage 216ND-70928 (E), Issue 1.0 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE10-3For setting FP No. 0 For mounting this card in PIM0 1 For mounting this card in PIM2 2 For mounting this card in PIM4 3 For mounting this card in PIM6 4-F Not used MB (Toggle SW) NOTE 2UPFor make-busy For normal operation SW1 (Piano Key SW)1 - 3Not used 4For normal operation OFFNot used 0 1 2 3 ON DOWN 4 3 2 1 OFF ON OFF ON
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-PW00 (EXTPWR) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 217 PN-PW00 (EXTPWR) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Remains lit while –48V power is being supplied RUN MB08 07 06 05-48V -48V E E 04 03 02 01-48V -48V E E CONNTO DESKCON
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-PW00 (EXTPWR) NEAX2000 IVS2 Installation Procedure ManualPage 218ND-70928 (E), Issue 1.0 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK MB (Toggle SW) NOTEUPFor make-busy (–48V power off) For normal operation (–48V power on) ON DOWN
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PZ-PW121 (AC/DC PWR) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 219 PZ-PW121 (AC/DC PWR) Locations of Lamps, Switches, and Connectors SW 1 SW2 SW 102SW 301 SW 101 ON OFF BATT BATT SW2 CN1 CN104 CN103 (SIGNAL) MJ MN ON MJ MN ON
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PZ-PW121 (AC/DC PWR) NEAX2000 IVS2 Installation Procedure ManualPage 220ND-70928 (E), Issue 1.0 Lamp Indications Switch Settings LAMP NAME COLOR FUNCTION MJ Red Remains lit when a major trouble occurres or resident system program is not properly loaded MN Yellow Remains lit when a minor trouble occurres or resident system program is successfully loaded, or a station line is locked out ON Green Remains lit while the operating power is being supplied C AUTION When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its mounting slot. SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK SW1 For turning AC power and the bat- tery on OFF For turning AC power and the bat- tery off SW2 FORWARD AC INPUT: 90V-132V BACKWARD AC INPUT: 180V-264V SW101 (Piano key) 1 Not used 2Float charging, for sealed batteries (Normal Setting). OPTION: Periodic Equalize charg- ing of external vented batteries. OFF Float charging, for vented batteries only. (Continued) OFF ON ON 100/120V AC 240V AC OFF ON 1 2 OFF ON
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PZ-PW121 (AC/DC PWR) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 221 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW301 (DIP SW) 1ON CR Voltage: 75Vrms OFF CR Voltage: 90Vrms 2ON Frequency: 20 Hz OFF Frequency: 25 Hz SW102 PRESS MOMEN- TA R I LYTo start each PIM on battery power when AC power is not provided 1 2ON OFF 25Hz 20Hz90V 75V
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PZ-PW122 (DC/DC PWR) NEAX2000 IVS2 Installation Procedure ManualPage 222ND-70928 (E), Issue 1.0 PZ-PW122 (DC/DC PWR) Locations of Lamps, Switches, and Connectors SWON CONN CONN connector: To PWR1 connector on PIM BWB POWER OUTPUT CABLE (-48V, E): To PWR0C connector on PIM BWB
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PZ-PW122 (DC/DC PWR) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 223 Lamp Indications Switch Settings LAMP NAME COLOR FUNCTION ON Green Remains lit while the operating power is being supplied C AU TIO N When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its mounting slot. SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK SW ON For turning AC power on OFF For turning AC power off OFF ON
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS Application Processor Card NEAX2000 IVS2 Installation Procedure ManualPage 224ND-70928 (E), Issue 1.0 APPLICATION PROCESSOR CARD The table below shows the application cards to be explained in this section. Table 3-2 List of Application Processor Cards NAME (FUNCTIONAL NAME)LAMP X: PROVIDED –:NOT PROVIDEDSWITCH X: PROVIDED –:NOT PROVIDEDEXTRACTION/ INSERTION WITH POWER ON X: ALLOWED : ALLOWED AFTER MB* –: NOT ALLOWEDREFERENCE PA G E PN-AP00-A (DBM) X XPage 226 PN-AP00-B (AP00) X XPage 229 PN-AP01 (AP01) X XPage 235 PN-BRTA (BRT) X XPage 238 PN-2BRTC (BRT) X XPage 243 PN-CC01 (ETHER) X X XPage 248 PN-DAIA (DAI) X XPage 252 PN-DAIB (DAI) X XPage 257 PN-DAIC (DAI) X XPage 261 PN-DAID (DAI) X XPage 264 PN-DAIE (DAI) X XPage 270 PN-DAIF (DAI) X XPage 274 PN-24DTA-C (DTI) X XPage 278 PN-30DTC-A (DTI) X XPage 284 PN-IPTA (IPT) X XPage 290 PN-24PRTA (PRT) X XPage 294 *MB = Make Busy