    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-CP15 (FP)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 215
    PN-CP15 (FP)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while the circuit card is operating normally.
    SENSE
    RUN
    MB
    SW1 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-CP15 (FP)
    NEAX2000 IVS2 Installation Procedure ManualPage 216ND-70928 (E), Issue 1.0
    Switch Settings
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and    , the setting of the switch varies with the system concerned.
    NOTE 1:
    Set the groove on the switch to the desired position.
    NOTE 2:
    When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
    ging the circuit card. 
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE 
    (Rotary SW)
    NOTE10-3For setting FP No.
    0 For mounting this card in PIM0
    1 For mounting this card in PIM2
    2 For mounting this card in PIM4
    3 For mounting this card in PIM6
    4-F Not used
    MB (Toggle SW)
    NOTE 2UPFor make-busy
    For normal operation
    SW1
    (Piano Key SW)1 - 3Not used
    4For normal operation
    OFFNot used
    0
    1
    2
    3
    ON
    DOWN
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    ON 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-PW00 (EXTPWR)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 217
    PN-PW00 (EXTPWR)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Remains lit while –48V power is being supplied
    RUN
    MB08
    07
    06
    05-48V
    -48V
    E
    E
    04
    03
    02
    01-48V
    -48V
    E
    E
    CONNTO DESKCON 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-PW00 (EXTPWR)
    NEAX2000 IVS2 Installation Procedure ManualPage 218ND-70928 (E), Issue 1.0
    Switch Settings
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    NOTE:
    When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
    ging the circuit card.
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    MB (Toggle SW)
    NOTEUPFor make-busy 
    (–48V power off)
    For normal operation
    (–48V power on)
    ON
    DOWN 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PZ-PW121 (AC/DC PWR)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 219
    PZ-PW121 (AC/DC PWR)
    Locations of Lamps, Switches, and Connectors
    SW 1
    SW2 SW 102SW 301
    SW 101
    ON
    OFF
    BATT BATT
    SW2
    CN1 CN104 CN103 (SIGNAL)
    MJ 
    MN 
    ON 
     MJ 
    MN 
    ON 
      
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PZ-PW121 (AC/DC PWR)
    NEAX2000 IVS2 Installation Procedure ManualPage 220ND-70928 (E), Issue 1.0
    Lamp Indications 
    Switch Settings
    LAMP 
    NAME COLOR FUNCTION
    MJ Red Remains lit when a major trouble occurres or resident system
    program is not properly loaded
    MN Yellow Remains lit when a minor trouble occurres or resident system program is successfully loaded, or a station line is locked out
    ON Green Remains lit while the operating power is being supplied
    C AUTION
    When the operating power is being supplied to this circuit card, do not plug/unplug this circuit
    card into/from its mounting slot.
    SWITCH NAME SWITCH 
    NUMBER SETTING 
    POSITION FUNCTION CHECK
    SW1 For turning AC power and the bat-
    tery on
    OFF For turning AC power and the bat- 
    tery off
    SW2 FORWARD AC INPUT: 90V-132V
    BACKWARD AC INPUT: 180V-264V
    SW101
    (Piano key) 1 Not used 
    2Float charging, for sealed batteries 
    (Normal Setting).
    OPTION: Periodic Equalize charg- 
    ing of external vented batteries.
    OFF Float charging, for vented batteries 
    only.
    (Continued)
    OFF
    ON
    ON
    100/120V AC 240V AC
    OFF
    ON
    1 
    2
    OFF
    ON 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PZ-PW121 (AC/DC PWR)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 221
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and    , the setting of the switch varies with the system concerned.
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SW301 (DIP SW)
    1ON CR Voltage: 75Vrms
    OFF CR Voltage: 90Vrms
    2ON Frequency: 20 Hz
    OFF Frequency: 25 Hz
    SW102
    PRESS 
    MOMEN-
    TA R I LYTo start each PIM on battery power
    when AC power is not provided
    1
    2ON OFF
    25Hz 20Hz90V 75V 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PZ-PW122 (DC/DC PWR)
    NEAX2000 IVS2 Installation Procedure ManualPage 222ND-70928 (E), Issue 1.0
    PZ-PW122 (DC/DC PWR)
    Locations of Lamps, Switches, and Connectors
    SWON CONN
    CONN connector: 
    To PWR1 connector on PIM BWB
    POWER OUTPUT CABLE (-48V, E): 
    To PWR0C connector on PIM BWB 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PZ-PW122 (DC/DC PWR)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 223
    Lamp Indications 
    Switch Settings
    LAMP 
    NAME COLOR FUNCTION
    ON Green Remains lit while the operating power is being supplied
    C
    AU TIO N
    When the operating power is being supplied to this circuit card, do not plug/unplug this circuit
    card into/from its mounting slot.
    SWITCH NAME SWITCH
    NUMBER SETTING
    POSITION FUNCTION CHECK
    SW
    ON For turning AC power on
    OFF For turning AC power off
    OFF 
    ON 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    Application Processor Card
    NEAX2000 IVS2 Installation Procedure ManualPage 224ND-70928 (E), Issue 1.0
    APPLICATION PROCESSOR CARD
    The table below shows the application cards to be explained in this section.
    Table 3-2  List of Application Processor Cards 
    NAME
    (FUNCTIONAL
    NAME)LAMP
    X: PROVIDED
    –:NOT 
    PROVIDEDSWITCH
    X: PROVIDED
    –:NOT 
    PROVIDEDEXTRACTION/
    INSERTION WITH 
    POWER ON
    X: ALLOWED
    : ALLOWED 
    AFTER MB*
    –: NOT ALLOWEDREFERENCE
    PA G E
    PN-AP00-A (DBM) X XPage 226
    PN-AP00-B (AP00) X XPage 229
    PN-AP01 (AP01) X XPage 235
    PN-BRTA (BRT) X XPage 238
    PN-2BRTC (BRT) X XPage 243
    PN-CC01 (ETHER) X X XPage 248
    PN-DAIA (DAI) X XPage 252
    PN-DAIB (DAI) X XPage 257
    PN-DAIC (DAI) X XPage 261
    PN-DAID (DAI) X XPage 264
    PN-DAIE (DAI) X XPage 270
    PN-DAIF (DAI) X XPage 274
    PN-24DTA-C (DTI) X XPage 278
    PN-30DTC-A (DTI) X XPage 284
    PN-IPTA (IPT) X XPage 290
    PN-24PRTA (PRT) X XPage 294