CHAPTER 2 INSTALLATION Battery Connection NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 95 C AU TIO N 3. Battery Replacement Table and Battery Warnings The label which shows battery replacement table and battery warnings is attached to the reverse side of Front Cover for PIM and BATTM. During the battery installation process, the warning statements must be observed. When re- placing batteries, the battery replacement table should be observed in order to increase bat- tery life and insure a safe operation. 0 ~ 50 °C 2 YEARS(AVERAGE 25 °C) LABEL PIM/BATTM FRONT COVER BATTERY REPLACEMENT TABLE INSTALLATION DATE: AMBIENT TEMPERATURE5 ~ 35 °C(AVERAGE 25 °C) REPLACEMENT INTERVAL 3 YEARS 1 YEAR CAUTIONTO PREVENT INJURY AND SKIN BURN, PAY ATTENTION TO THE FOLLOWING. o DO NOT STRIKE A MATCH OR CAUSE A SPARK IN VICINITY OF BATTERY. o PLACE THE EQUIPMENT WELL VENTILATED AREA. o DO NOT SHORT. o REPLACE BATTERY ONLY AFTER BATTERY GASES HAVE BEEN DISPERSED. o ELECTROLYTE LEAKAGE OR OTHER HAZARDS MAY RESULT IF THE BATTERY IS NOT REPLACED IN ACCORDANCE WITH THE SPECIFIED INTER- VALS. (AVERAGE 40 °C)0 ~ 50 °C
CHAPTER 2 INSTALLATION Internal Battery Connection NEAX2000 IVS2 Installation Procedure ManualPage 96ND-70928 (E), Issue 1.0 Internal Battery Connection (1) Connect the BATT CA INT cable to the batteries as shown below. (2) Mount the battery unit (24V DC, 3.2-3.4AH) into the PIM. (3) Plug the BATT CA INT connector into the BATT1 connector on the PZ-PW121 card. (4) Secure the batteries and battery cable using tie wraps. Figure 2-37 Internal Battery Mounting (1 of 2) 67 mmDIMENSION OF BATTERY(2.6 inch) 134 mm (5.3 inch) 60 mm (2.4 inch) Recommended Batteries Yuasa NPH-3.2-12 Matsushita LCR-12V 3.4NE BLUE/BLACK INTERNAL BATTERY UNIT (24V DC, 3.2 TO 3.4AH) PIM + + – RED BATT CA INT BLACK TO BATT1 CONNECTOR ON PZ-PW121 –
CHAPTER 2 INSTALLATION Internal Battery Connection NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 97 Figure 2-37 Internal Battery Mounting (2 of 2) TIE WRAP + + – –
CHAPTER 2 INSTALLATION Internal Battery Connection NEAX2000 IVS2 Installation Procedure ManualPage 98ND-70928 (E), Issue 1.0 (5) When the system is configured with two or more PIMs, connect the BATT CA INT and the PWR CA-A as shown below. Figure 2-38 Internal Battery Connection for Multiple-PIM Configuration NOTE 1: One Internal Battery unit (24V DC, 3.2-3.4AH) can be mounted in each PIM. NOTE 2: Internal Batteries are multi-connected for each two PIMs. PIM3PWR PIM2 PIM1PIM7 PIM6 PIM5 PIM4 PIM0 PWR PWR PWR PWR PWR PWR PWR BATT CA INT BATT CA INT BATT CA INT BATT CA INTBATT CA INT BATT CA INT BATT CA INT BATT CA INT PWR CA-A PWR CA-APWR CA-A PWR CA-A
CHAPTER 2 INSTALLATION External / BATTM Battery Connection NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 99 External / BATTM Battery Connection (1) Connect the BATT CA EXT cable to the batteries as shown below. (2) Mount the battery units (24V DC, 24AH per unit) into the Battery Module (BATTM), if the BATTM required. (3) Plug the BATT CA EXT connector into the BATT1 connector on the PZ-PW121 card in PIM0 or PIM4. NOTE:Screws are attached to the BATTM. Figure 2-39 Battery Mounting into BATTM Recommended Batteries Yuasa NP-24-12B Matsushita LCL-12V-24 DIMENSION OF BATTERY 175 mm (6.9 inch) 125 mm (4.9 inch) 165 mm (6.5 inch) BATTERY UNIT (24V DC, 24AH) BATTERY UNIT (24V DC, 24AH) BATT CA EXTTO BATT1 CONNECTOR ON PZ-PW121 IN PIM0/PIM4
CHAPTER 2 INSTALLATION External / BATTM Battery Connection NEAX2000 IVS2 Installation Procedure ManualPage 100ND-70928 (E), Issue 1.0 Figure 2-40 Battery Mounted into BATTM BATTM FRONT TO BATT1 CONNECTOR ON PZ-PW121 IN PIM0/PIM4
CHAPTER 2 INSTALLATION External / BATTM Battery Connection NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 101 (3) When the system is configured with two or more PIMs, connect the BATT CA EXT and the PWR CA-A as shown below. Figure 2-41 External/BATTM Battery Connection for Multiple-PIM Configuration NOTE 1: One pair each of battery unit (24V DC, 24AH) can be housed in a BATTM, for each two PIMs. NOTE 2: External Batteries are multi-connected for each four PIMs. PWR BATT CA EXTPWR CA-APWR CA-A PWR PWR PWR PWR PWR PWR PWR PIM0 BATT CA EXTPIM4 BATTM/ EXTERNAL BATTBATTM/ EXTERNAL BATT PIM1PIM5 PIM2PIM6 PIM3PIM7
CHAPTER 2 INSTALLATION Cable Running to MDF NEAX2000 IVS2 Installation Procedure ManualPage 102ND-70928 (E), Issue 1.0 CABLE RUNNING TO MDF Installation of External MDF Secure the external MDF onto the floor or the wall. Mount the required MDF components. If required, install the cable ducts for the cables to be laid between the MDF and the Main Equipment. In this case, confirm the locations of the cable holes for the Main Equipment. Figure 2-42 MDF Cable Hole Location BASE MODULE : CABLE HOLE FRONT
CHAPTER 2 INSTALLATION MDF Cable NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 103 MDF Cable To facilitate the termination of the 25 pair cables (MDF cables) from the system to the MDF shown in Figure 2-43, the length of each cable to be used should be predetermined according to the distance between the MDF and the system. Each cable should be labeled at both ends using a cable number or cable designation as shown in Table 2-2. Figure 2-43 MDF Cable TO P I MCHAMP CONNECTOR TWISTED 25 PAIR CABLES TO M DF
CHAPTER 2 INSTALLATION MDF Cable NEAX2000 IVS2 Installation Procedure ManualPage 104ND-70928 (E), Issue 1.0 Table 2-2 MDF Cables for each PIM FROM CABLE NUMBERTOCABLE DESIGNATION MODULE CONNECTION PIM 0 LTC0 1 MDF 0 LTC0 LT C 1 2 0 LT C 1 LT C 2 3 0 LT C 2 LT C 3 4 0 LT C 3 PIM 1 LTC0 5 MDF 1 LTC0 LT C 1 6 1 LT C 1 LT C 2 7 1 LT C 2 LT C 3 8 1 LT C 3 PIM 2 LTC0 9 MDF 2 LTC0 LT C 1 1 0 2 LT C 1 LT C 2 1 1 2 LT C 2 LT C 3 1 2 2 LT C 3 PIM 3 LTC0 13 MDF 3 LTC0 LT C 1 1 4 3 LT C 1 LT C 2 1 5 3 LT C 2 LT C 3 1 6 3 LT C 3 PIM 4 LTC0 17 MDF 4 LTC0 LT C 1 1 8 4 LT C 1 LT C 2 1 9 4 LT C 2 LT C 3 2 0 4 LT C 3 PIM 5 LTC0 21 MDF 5 LTC0 LT C 1 2 2 5 LT C 1 LT C 2 2 3 5 LT C 2 LT C 3 2 4 5 LT C 3