CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIF (DAI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 275 Switch Settings SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK MB (Toggle SW) N OTE UP For make-busy For normal operation SW1 (Piano Key SW) 1 Always set to OFF 2 ON Line impedance: 75 ohms (For coaxial cable) Line impedance: 120 ohms (For twisted-pair cable) 3 Always set to OFF 4 Always set to OFF (Continued) ON DOWN 4 3 2 1 OFF ON OFF OFF OFF OFF
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIF (DAI) NEAX2000 IVS2 Installation Procedure ManualPage 276ND-70928 (E), Issue 1.0 SW2 (DIP SW) 1ONControl channel signaling data transmission speed: 48kbps Control channel signaling data transmission speed: 64kbps 2ONCRC Synchronization Detection Timer is provided. CRC Synchronization Detection Timer is not provided. 3ON CRC4 Check is provided. CRC4 Check is not provided. 4 Not used 5 Not used 6 Not used 7 Not used 8 Not used (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1 23 45 67 8ON OFF OFF OFF OFF OFF OFF OFF OFF
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-DAIF (DAI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 277 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. SW3 (DIP SW) 1 Always set to ON 2 Always set to ON 3 Always set to ON 4ONWhen mounting this card on remote site. OFFWhen mounting this card on main site. JPS (Jumper pin) RightTA is grounded on the transmission line: 75 ohms (For coaxial cable) Balanced transmission: 120 ohms (For twisted-pair cable) JPR (Jumper pin) RightRA is grounded on the transmission line: 75 ohms (For coaxial cable) Balanced transmission: 120 ohms (For twisted-pair cable) JP (Jumper pin) UPLine impedance: 75 ohms (For coaxial cable) Line impedance: 120 ohms (For twisted-pair cable) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1 23 4ON ON ON ON Left Left DOWN
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24DTA-C (DTI) NEAX2000 IVS2 Installation Procedure ManualPage 278ND-70928 (E), Issue 1.0 PN-24DTA-C (DTI) Locations of Lamps, Switches, and Connectors SENSE RUN MB CRC PCM FRM RMT AIS BL SW1 SW0 JRR1 AISS MAS JPR0 JPS
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24DTA-C (DTI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 279 Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. CRC Red Remains lit when detecting Cyclic Redundancy Checking (CRC) errors. PCM Red Remains lit when detecting PCM signal loss. FRM Red Remains lit when detecting Frame Alignment signal loss. RMT Red Remains lit when receiving Frame Alignment signal loss alarm from a distant office. AIS Red Remains lit when a pattern of consecutive “1” is received. The distant office transmits this signal for a loop-back test. BL Red B channel status ON : More than 10 channels are busy OFF : All channels are idle Flash (60 IPM) : Only one channel is busy Flash (120 IPM) : 2 through 10 channels are busy
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24DTA-C (DTI) NEAX2000 IVS2 Installation Procedure ManualPage 280ND-70928 (E), Issue 1.0 Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 10-3 Not used 4-F Set the switch to match the AP Number (04-31) to be set by CM05. MB (Toggle SW) NOTE 2UP For make-busy For normal operation (Continued) F 4 AP No.SW1-4: ON 04 05 06 07 08 09 10 11 12 13 14 15 SW1-4: OFF 20 21 22 23 24 25 26 27 28 29 30 31 SW No. 456789ABCDEF ON DOWN
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24DTA-C (DTI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 281 SW0 (Piano Key SW) 1 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO 0 input on MP card. OFFSource clock signal from network is not sent to the PLO 0 input on MP card. 2 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO 1 input on MP card. OFFSource clock signal from network is not sent to the PLO 1 input on MP card. 3ONRemote loop-back For normal operation 4ONLocal loop-back (AIS send) For normal operation 5Set equalizer according to the cable length between the PBX and the MDF. OFF 6 OFF 7 OFF 8 Not used (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK OFF ON 5 6 7 8 1 2 3 4 OFF OFF ON OFF 80-120m (262.5-394ft.) SW0-5 SW0-6 SW0-7CABLE LENGTH ON ON0-40m (0-131.2ft.) 40-80m (131.2-262.5ft.) 120-160m (394-525ft.) 160-200m (525-656ft.) Signal is not sent ON ON ON ON ON OFF OFF ON OFF ON OFF ON OFF OFF OFF ON ON OFF
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24DTA-C (DTI) NEAX2000 IVS2 Installation Procedure ManualPage 282ND-70928 (E), Issue 1.0 The figure in the SWITCH NAME column and the position in in the SETTING POSITION- column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned.SW1 (Piano Key SW) NOTE 41 Not used 2 Not used 3 Not used 4ON AP No. 04-15 OFF AP No. 20-31 JPR0 (Jumper pin) UPNeutral grounding on the receiving line is provided. Neutral grounding on the receiving line is not provided. JPR1 (Jumper pin) Line impedance: 100 ohms Left Line impedance: 110 ohms JPS (Jumper pin) UPNeutral grounding on the transmit- ting line is provided. Neutral grounding on the transmit- ting line is not provided. MAS (Jumper pin) UP Clock Source Clock Receiver AISS (Jumper pin) AIS signal is sent out when make- busy or power on. DOWNAIS signal is not sent out when make-busy or power on. (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 4 3 2 1 OFF ON OFF OFF OFF DOWN Right DOWN DOWN UP
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-24DTA-C (DTI) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 283 NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. NOTE 3: Set SW0-1 and SW0-2 as follows: NOTE 4: When the PBX is a clock source office, set the SW0-1 and SW0-2 on all the DTI cards mounted in PIM0 to “OFF”. NOTE 5: Mount the DTI card which receives a source clock signal into PIM0. CONDITIONSDTI0 DTI1 DTI2 DTI3 DTI4 REMARKS SW 0-1SW 0-2SW 0-1SW 0-2SW 0-1SW 0-2SW 0-1SW 0-2SW 0-1SW 0-2 When one DTI is provided.ON OFF––––––––MP card will receive the clock signal from DTI0 at its PLO0 input. When more than one DTI is pro- vided.ON OFF OFF ON OFF OFF OFF OFF OFF OFFMP card will receive the clock signal from DTI0 at its PLO0 input, under normal conditions. Should a clock failure occur with DTI0, MP card will auto- matically switch to the PLO1 input which gets clock from DTI1.
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-30DTC-A (DTI) NEAX2000 IVS2 Installation Procedure ManualPage 284ND-70928 (E), Issue 1.0 PN-30DTC-A (DTI) Locations of Lamps, Switches, and Connectors SENSE RUN MB SW PCM FRM MFRM RMT MRMT AIS BL JP JPSJPR