CHAPTER 2 INSTALLATION System Data Save NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 205 SYSTEM DATA SAVE After system data entry, save the system data to floppy diskette. Refer to “MATWorX Users Guide” for the operation of system data save. CLEANING AND VISUAL CHECK Cleaning Clean the following places: Inside of the main equipment, especially the bottom of the base. On the Top Cover. Around the Main Equipment and the MDF. Keyboard on the Attendant Console. Visual Check (1) Check to see if all circuit cards are in their positions correctly. (2) Check that the cable connections in the PIM are correctly and completely connected, and the routing of the cables has been done smoothly and neatly. (3) Check to see if the MAT is removed.
NEAX2000 IVS2 Installation Procedure ManualPage 206 ND-70928 (E), Issue 1.0 This page is for your notes.
NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 207 CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS This chapter explains the meaning of lamp indications and the method of switch settings of each circuit card used in the system.
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS How To Read This Chapter NEAX2000 IVS2 Installation Procedure ManualPage 208ND-70928 (E), Issue 1.0 HOW TO READ THIS CHAPTER This chapter explains each circuit card used in this system about the following items. Explana- tions are given in alphabetical order of the circuit card names within each circuit card category (Control, Application Processor, and Line/Trunk). (1) Locations of Lamps, Switches, and Connectors The locations of lamps, switches, and connectors of each circuit card are shown by a face layout. (2) Lamp Indications The name, color, and functions of each indicator lamp equipped on each circuit card are described in a table. (3) Switch Settings The name, settings, and functions of each switch equipped on each circuit card are described in a table. Each switch setting table has a “CHECK” column. Make necessary entries in the CHECK column during and/or after the system installation and maintenance, and use each table as a reference for subsequent system maintenance and operations.
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS Control Card NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 209 CONTROL CARD The table below shows the control cards explained in this section. *MB = Make Busy Table 3-1 List of Control Cards NAME (FUNCTIONAL NAME)LAMP X: PROVIDED –:NOT PROVIDEDSWITCH X: PROVIDED –:NOT PROVIDEDEXTRACTION/ INSERTION WITH POWER ON X: ALLOWED : ALLOWED AFTER MB* –: NOT ALLOWEDREFERENCE PA G E PN-CP14 (MP) X X–Page 210 PN-CP15 (FP) XXPage 215 PN-PW00 (EXTPWR)XXPage 217 PZ-PW121 (AC/DC PWR)XX–Page 219 PZ-PW122 (DC/DC PWR)XX–Page 222
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-CP14 (MP) NEAX2000 IVS2 Installation Procedure ManualPage 210ND-70928 (E), Issue 1.0 PN-CP14 (MP) Locations of Lamps, Switches, and Connectors CONN: To CONNR connector on PZ-M537 (EXPMEM) Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. CLK Green Remains lit while receiving clock signals to the PLO. SW3 RUN SW1 SW2 CLK VR DK JACK CONNSW4 JP0JP1 RS1 RS0
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-CP14 (MP) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 211 Switch Settings NOTE 1: Set the groove on the switch to the desired position. NOTE 2: Only when executing “MP Program Download ” in MATWorX, set the SW3 to 5-8. C AU TIO N When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its mounting slot. SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK SW3 (Rotary SW) NOTE 1 0-FOn Line (Call processing is in progress) 2 Off Line (Call processing is stopped) I/O port: As per CM40 YY=08 3 Off Line (Call processing is stopped) I/O por t: 9600 bps (Fixed) 5 NOTE 2 Off Line (Call processing is stopped) I/O por t: 9600 bps 6 NOTE 2 Off Line (Call processing is stopped) I/O por t: 19200 bps 7 NOTE 2 Off Line (Call processing is stopped) I/O por t: 38400 bps 8 NOTE 2 Off Line (Call processing is stopped) I/O por t: 57600 bps B For clearing the office data C For setting the resident system pro- gram 1, 4, 9 A, D-F Not used (Continued) 0 0
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-CP14 (MP) NEAX2000 IVS2 Installation Procedure ManualPage 212ND-70928 (E), Issue 1.0 SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW1 (Push SW) For initializing CPU SW2 (Piano Key SW)1ON A-law (Australia) OFF µ-law (North America) 2, 3Selection of PLO0 input (Phase Locked Oscillator) For clock receiver office: For clock source office: SW2-2 SW2-3 OFF OFF 4ONWhen using RS1 por t for built-in MODEM OFF When using RS1 port for RS-232C (Continued) 4 3 2 1 OFF ONSW2-2 SW2-3 FUNCTION OFF OFF 1.5MHz clock [For PN-24DTA-C/PN-24PRTA] ON OFF 192kHz clock [For PN-BRTA] OFF ON 2MHz clock [For PN-30DTC-A/PN-2BRTC] ON ON Not used
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-CP14 (MP) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 213 SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SW4 (DIP SW)1 Not used 2 Not used 3, 4Selection of PLO1 input (Phase Locked Oscillator) For clock receiver office: For clock source office: SW4-3 SW4-4 OFF OFF VR (Rotary SW) Variable Resistor for External Hold Tone Source (0 - 20 Kohms : Clockwise) DK (Connector) 02 Ground detection 01 Ground sending (Continued) 1 23 4ON OFF OFF SW4-3 SW4-4 FUNCTION OFF OFF 1.5MHz clock [For PN-24DTA-C/PN-24PRTA] ON OFF 192kHz clock [For PN-BRTA] OFF ON 2MHz clock [For PN-30DTC-A/PN-2BRTC] ON ON Not used 20 0 01 02
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-CP14 (MP) NEAX2000 IVS2 Installation Procedure ManualPage 214ND-70928 (E), Issue 1.0 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK JP0 (Jumper pin) UPNot used (Memory backup OFF) For normal operation (Memory backup ON) JP1 (Jumper pin) For using internal tone source DOWN For using external tone source FrontDOWN Fr o n t UP