    							CHAPTER 2 INSTALLATION
    SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 195
    
    Connection via MODEM
    When the cable length between the PBX and the terminal is more than 15 m (49.2 ft), MO-
    DEMs are required. Use RS RORM-4(S) CA-A as shown below. See also Figure 2-99.
    Figure 2-101  SMDR/PMS/MCI Terminal Connection via MODEMs
    RS0 - RS3
    PN- PBX
    (PIM0 - PIM7)
    RS NORM-4S CA-A: 
    4m (13.1 ft.)MODEM MODEM2P
    MORE THAN 15m (49.2 ft.) 
    MODEM: FULL DUPLEX (4W)
    1200 bps (LEASED TYPE)INTERFACE CABLE
    (FOR STRAIGHT
    CONNECTION)
    TO RS-232C PORT
    RS NORM-4 CA-A/
    SMDR0/SMDR1/
    PMS/MCI (VMS) AP00-B 
    						
    							CHAPTER 2 INSTALLATION
    SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
    NEAX2000 IVS2 Installation Procedure ManualPage 196ND-70928 (E), Issue 1.0
    (2) CIS Printer/Hotel Printer
    
    Direct Connection
    Connect a maximum of two printers to the PN-AP00-B using the RS PRT-15(S) CA-A as 
    shown below.
    Figure 2-102  Printer Direct Connection
    
    Connection via MODEM
    When the cable length between the printer and the PBX is more than 15 m (49.2 ft.), MO-
    DEMs are required.
    Figure 2-103  Printer Connection via MODEMs
    PN-PBX
    RS0-RS3
    RS PRT-15 CA-A/
    RS PRT-15S CA-A : 15 m (49.2 ft.)
    PRINTER0/PRINTER1
    MAX. 15 m (49.2 ft.) AP00-BCONNECTOR
    PN-PBX
    RS0-RS3
    RS NORM-4 CA-A/
    RS NORM-4S CA-A : 4 m (13.1 ft.)
    PRINTER0/PRINTER1
    MORE THAN 15 m (49.2 ft.)
    INTERFACE CABLE
    (FOR STRAIGHT
    CONNECTION)
    MODEM MODEM2P
    MODEM:  FULL DUPLEX (4W)
    1200 bps (LEASED TYPE) AP00-BCONNECTOR 
    						
    							CHAPTER 2 INSTALLATION
    SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 197
    Figure 2-104  RS PRT-15 CA-A/RS PRT-15S CA-A
    See Table 2-7.
    05C-DTR
    MAX. 15 m (49.2 ft.)
    05B-GND 01-GND
    05A-TXD 03-RXD
    03B-CTS 20-DTR
    03A-DSR
    02B-GND 07-GND
    DCB A
    06 TXC
    (1)XRXCTXC
    (2)
    05 X DTR GND TXD
    04 (RT) X RXD RTS
    03 X (ST) CTS DSR
    02 ---- X GND DCD
    01 X LALB X G25 ----
    24 ----
    23 ----
    22 ----
    21 ----
    20 DTR
    19 ----
    18 ----
    17 ----
    16 ----
    15 ----
    14 ----13 ----
    12 ----
    11 ----
    10 ----
    09 ----
    08 ----
    07 GND
    06 ----
    05 ----
    04 ----
    03 RXD
    02 ----
    01 GND
    G:  GROUND 
    						
    							CHAPTER 2 INSTALLATION
    SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
    NEAX2000 IVS2 Installation Procedure ManualPage 198ND-70928 (E), Issue 1.0
    Table 2-7  RS-232C Connector Layout
    PIN 
    NO.SIGNAL-NAME
    SIGNAL 
    DIRECTIONMEANING
    RS-232C JIS C6361ITU-T 
    V. 2 4ANOTHER
    1 AA (FG) 101 GND Frame Ground
    2 BA SD 103 TXD DTE Send Data
    3 BB RD 104 RXD DCE Receive Data
    4 CA RS 105 RTS DTE Request to Send
    5 CB CS 106 CTS DCE Clear to Send
    6 CC DR 107 DSR DCE Data Set Ready
    7 AB SG 102 GND Signal Ground
    8 CF CD 109 DCD DCE Data Channel Receive Carrier 
    Detect
    9 Not Used
    10 Not Used
    11 PB Peripheral Busy
    12 SCF BCD 122 DCE Backward Channel Receive Carrier
    Detect
    13 SCB BCS 121 DCE Backward Channel Send (OK)
    14 SBA BSD 118 DTE Backward Channel Send Data
    15 DB ST2 114 TXC (2) DCE Send Signal Element Timing
    16 SBB BRD 119 DCE Backward Channel Receive Data
    17 DD RT 115 RXC DCE Receive Signal Element Timing
    18 Not Used
    19 SCA BRS 120 DTE Backward Channel Send Detect
    20 CD ER 108/2 DTR DTE Data Terminal Ready
    21 CG SQD 110 DCE Data Signal Quality Detect
    22 CE CI 125 RI DCE Call Indication
    23 CI, CH SRS 112, 111 –  Data Signal Speed Choice
    24 DA ST1 113 TXC (1) DCE Send Signal Element Timing
    25 Not Used 
    						
    							CHAPTER 2 INSTALLATION
    Mounting Circuit Cards
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 199
    MOUNTING CIRCUIT CARDS
    (1) Before mounting the circuit cards, confirm the following items.
    Wrist Strap is connected to Frame Ground.
    Switch settings of circuit cards are already completed. See CHAPTER 3.
    The “SW1” switches of all PZ-PW121 cards are turned off.
    (2) Mount circuit cards into their mounting positions according to the “Bay Face Layout” and 
    “Port Assignment Table” given in the Office Data Programming Manual. See CHAPTER 1 
    “MOUNTING CONDITIONS OF CIRCUIT CARD”on  Page 29
    .
    This figure shows the mounting method of circuit cards.
    Figure 2-105  Mounting of Circuit Cards
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    CARD LABEL
    CARD FRONT SIDE
    WRIST STRAP
    TO FRAME GROUND CONNECTION
    (Page 39
    )
    CARD CONTACT SIDE 
    						
    							CHAPTER 2 INSTALLATION
    Mounting Circuit Cards
    NEAX2000 IVS2 Installation Procedure ManualPage 200ND-70928 (E), Issue 1.0
    (3) Fix the CARD STOPPER according to the following procedure.
    STEP 1: After mounting all circuit cards slide the CARD STOPPER to the left.
    STEP 2: Tighten the screws of the CARD STOPPER as shown below.
    NOTE:
    When sliding the PIM CARD STOPPER, loosen all of the screws securing the PIM
    CARD STOPPER and the PZ-M542/PZ-M557 card (the screws need not to be re-
    moved).
    Figure 2-106  Installation of the CARD STOPPER
    CARD 
    STOPPER
    CARD 
    STOPPER CIRCUIT CARD
    CIRCUIT CARD
    SLIDE THE CARD 
    STOPPER TO THE LEFT.SCREWSCREW 
    						
    							CHAPTER 2 INSTALLATION
    System Initialization
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 201
    SYSTEM INITIALIZATION
    There are two methods for System Initialization. The first method is to Clear All
    Data, except LEN000 as a CAT terminal, then program the System Data. The
    second method is to use the Resident System Program, which causes the sys-
    tem to configure itself automatically to the default settings, wherever the line/
    trunk cards are installed.
    NOTE 1:
    See CHAPTER 3 for MP switch settings.  Page 209
    NOTE 2:
    Refer to the Command Manual for default settings on the Resident System Program.
    All Clear, Except LEN000 CAT
    STEP 1: Turn on the “SW1” switch on all the PZ-PW121 cards.
    -The “ON” lamp must be lit on all the PZ-PW121 cards.
    STEP 2: On the MP Card, set SW3 to “B” and press SW1.
    STEP 3: When the “MN” lamp on the system is lit, set SW3 to the “0” position and press SW1.
    - The operating mode has been changed to the ON LINE mode.
    Resident System Program
    STEP 1: Mount the line/trunk cards into PIM.
    STEP 2: Turn on the “SW1” switch on all the PZ-PW121 cards.
    -The “ON” lamp must be lit on all the PZ-PW121 cards.
    STEP 3: On the MP card, set SW3 to “C” and press SW1.
    - After 30 to 40 seconds, the “MN” lamp turns on.
    - The system has loaded the Resident System Program.
    NOTE:
    If the “MJ” lamp is lit, repeat Step 3.
    STEP 4: On the MP card, set SW3 to the “0” position and press SW1.
    - The operating mode has been changed to the ON LINE mode.
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 2 INSTALLATION
    System Data Entry
    NEAX2000 IVS2 Installation Procedure ManualPage 202ND-70928 (E), Issue 1.0
    SYSTEM DATA ENTRY
    There are two methods for data entry, using a Customer Administration Terminal
    (CAT) or a Maintenance Administration Terminal (MAT).
    NOTE:
    For assigning system data, refer to the Command Manual.
    CAT
    Any Dterm can be assigned as a CAT through programming. The Dterm can still be used as a reg-
    ular telephone when it is not in CAT mode. If the system is initialized by “C” (Resident System
    Program), every D
    term will be able to go into CAT mode. If the system is initialized by “B” (All
    Clear), only LEN000 is assigned as a CAT port (the DLC card must be installed in slot LT00).
    To use a D
    term as a CAT, follow the procedures shown below.
    NOTE:
    It is necessary to complete steps 1 through 6 within 4 seconds.
    To set CAT mode:
    1. Press or
    2. Press or
    - CNF/Conf lamp flashes
    3. Press
    - CNF/Conf lamp is off
    4. Press or
    5. Press or
    - CNF/Conf lamp flashes
    6. Press
    - CNF/Conf, SPKR/Speaker, FNC/Feature lamps are lit
    -“CAT MODE” is displayed on the LCD
    7. Press or
    -“COMMAND = -” is displayed on the LCD
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    TRFTr a n s f e r
    CNFConf
    *
    TRFTr a n s f e r
    CNFConf
    #
    LNR/SPDRedial 
    						
    							CHAPTER 2 INSTALLATION
    MAT
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 203
    To reset CAT mode:
    While “COMMAND = -” is displayed on the LCD:
    1. Lift the handset (off hook)
    - SPKR/Speaker lamp turns off.
    2. Restore the handset (on hook)
    - CNF/Conf, FNC/Feature lamps turn off.
    - LCD returns to clock.
    MAT
    Refer to the MATWorX User Guide.
    Cofirming Lamp Indication
    After system data entry, confirm proper operation of the system using indicator lamps.
    RUN Lamp Flashing (120 IPM)
    Check that the RUN lamps of PN-CP14 card and other application circuit cards are flashing.
    ON Lamps of All PZ-PW121 Cards Lightning
    Check that the ON lamps of all the PZ-PW121 cards are lightning and their MJ/MN lamps 
    have gone out.
    BL Lamps Gone Out
    Check that the BL lamps of all the line/trunk circuit cards have gone out. If BL lamps are 
    flashing, it means that the corresponding circuit is in make-busy state or the system data for 
    this card is not assigned.  
    For more details of lamp indication, see CHAPTER 3. For information of maintenance servicing
    and troubleshooting of the equipment, refer to the Maintenance Manual.
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 2 INSTALLATION
    Operation Test
    NEAX2000 IVS2 Installation Procedure ManualPage 204ND-70928 (E), Issue 1.0
    OPERATION TEST
    Confirm the entered system data and hardware, including cable connection, by completing the
    following operational tests.
    Basic Connection Test at MDF
    Station Line Test (Operator Call from all stations)
    Central Office Trunk Test (Incoming, Outgoing)
    Tie Line Trunk Test (Incoming, Outgoing)
    Service Feature Test
    Call Transfer
    Step Call
    Executive Right of Way (Executive Override)
    Call Hold
    Call Back
    Call Forwarding-All Calls/Don’t Answer (No Answer)/Busy Line
    Call Pickup
    Station Hunting-Pilot/Circular
    Speed Calling-Station/System (Station Speed Dial/System Speed Dial)
    Paging Access (External Paging with Meet-me)
    Announcement Service
    Other selected features
    NOTE:
    Feature names in parentheses are for North America. 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Installation Procedure Manual