CHAPTER 2 INSTALLATION SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 195 Connection via MODEM When the cable length between the PBX and the terminal is more than 15 m (49.2 ft), MO- DEMs are required. Use RS RORM-4(S) CA-A as shown below. See also Figure 2-99. Figure 2-101 SMDR/PMS/MCI Terminal Connection via MODEMs RS0 - RS3 PN- PBX (PIM0 - PIM7) RS NORM-4S CA-A: 4m (13.1 ft.)MODEM MODEM2P MORE THAN 15m (49.2 ft.) MODEM: FULL DUPLEX (4W) 1200 bps (LEASED TYPE)INTERFACE CABLE (FOR STRAIGHT CONNECTION) TO RS-232C PORT RS NORM-4 CA-A/ SMDR0/SMDR1/ PMS/MCI (VMS) AP00-B
CHAPTER 2 INSTALLATION SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00) NEAX2000 IVS2 Installation Procedure ManualPage 196ND-70928 (E), Issue 1.0 (2) CIS Printer/Hotel Printer Direct Connection Connect a maximum of two printers to the PN-AP00-B using the RS PRT-15(S) CA-A as shown below. Figure 2-102 Printer Direct Connection Connection via MODEM When the cable length between the printer and the PBX is more than 15 m (49.2 ft.), MO- DEMs are required. Figure 2-103 Printer Connection via MODEMs PN-PBX RS0-RS3 RS PRT-15 CA-A/ RS PRT-15S CA-A : 15 m (49.2 ft.) PRINTER0/PRINTER1 MAX. 15 m (49.2 ft.) AP00-BCONNECTOR PN-PBX RS0-RS3 RS NORM-4 CA-A/ RS NORM-4S CA-A : 4 m (13.1 ft.) PRINTER0/PRINTER1 MORE THAN 15 m (49.2 ft.) INTERFACE CABLE (FOR STRAIGHT CONNECTION) MODEM MODEM2P MODEM: FULL DUPLEX (4W) 1200 bps (LEASED TYPE) AP00-BCONNECTOR
CHAPTER 2 INSTALLATION SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 197 Figure 2-104 RS PRT-15 CA-A/RS PRT-15S CA-A See Table 2-7. 05C-DTR MAX. 15 m (49.2 ft.) 05B-GND 01-GND 05A-TXD 03-RXD 03B-CTS 20-DTR 03A-DSR 02B-GND 07-GND DCB A 06 TXC (1)XRXCTXC (2) 05 X DTR GND TXD 04 (RT) X RXD RTS 03 X (ST) CTS DSR 02 ---- X GND DCD 01 X LALB X G25 ---- 24 ---- 23 ---- 22 ---- 21 ---- 20 DTR 19 ---- 18 ---- 17 ---- 16 ---- 15 ---- 14 ----13 ---- 12 ---- 11 ---- 10 ---- 09 ---- 08 ---- 07 GND 06 ---- 05 ---- 04 ---- 03 RXD 02 ---- 01 GND G: GROUND
CHAPTER 2 INSTALLATION SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00) NEAX2000 IVS2 Installation Procedure ManualPage 198ND-70928 (E), Issue 1.0 Table 2-7 RS-232C Connector Layout PIN NO.SIGNAL-NAME SIGNAL DIRECTIONMEANING RS-232C JIS C6361ITU-T V. 2 4ANOTHER 1 AA (FG) 101 GND Frame Ground 2 BA SD 103 TXD DTE Send Data 3 BB RD 104 RXD DCE Receive Data 4 CA RS 105 RTS DTE Request to Send 5 CB CS 106 CTS DCE Clear to Send 6 CC DR 107 DSR DCE Data Set Ready 7 AB SG 102 GND Signal Ground 8 CF CD 109 DCD DCE Data Channel Receive Carrier Detect 9 Not Used 10 Not Used 11 PB Peripheral Busy 12 SCF BCD 122 DCE Backward Channel Receive Carrier Detect 13 SCB BCS 121 DCE Backward Channel Send (OK) 14 SBA BSD 118 DTE Backward Channel Send Data 15 DB ST2 114 TXC (2) DCE Send Signal Element Timing 16 SBB BRD 119 DCE Backward Channel Receive Data 17 DD RT 115 RXC DCE Receive Signal Element Timing 18 Not Used 19 SCA BRS 120 DTE Backward Channel Send Detect 20 CD ER 108/2 DTR DTE Data Terminal Ready 21 CG SQD 110 DCE Data Signal Quality Detect 22 CE CI 125 RI DCE Call Indication 23 CI, CH SRS 112, 111 – Data Signal Speed Choice 24 DA ST1 113 TXC (1) DCE Send Signal Element Timing 25 Not Used
CHAPTER 2 INSTALLATION Mounting Circuit Cards NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 199 MOUNTING CIRCUIT CARDS (1) Before mounting the circuit cards, confirm the following items. Wrist Strap is connected to Frame Ground. Switch settings of circuit cards are already completed. See CHAPTER 3. The “SW1” switches of all PZ-PW121 cards are turned off. (2) Mount circuit cards into their mounting positions according to the “Bay Face Layout” and “Port Assignment Table” given in the Office Data Programming Manual. See CHAPTER 1 “MOUNTING CONDITIONS OF CIRCUIT CARD”on Page 29 . This figure shows the mounting method of circuit cards. Figure 2-105 Mounting of Circuit Cards AT T E N T I O NContents Static Sensitive Handling Precautions Required CARD LABEL CARD FRONT SIDE WRIST STRAP TO FRAME GROUND CONNECTION (Page 39 ) CARD CONTACT SIDE
CHAPTER 2 INSTALLATION Mounting Circuit Cards NEAX2000 IVS2 Installation Procedure ManualPage 200ND-70928 (E), Issue 1.0 (3) Fix the CARD STOPPER according to the following procedure. STEP 1: After mounting all circuit cards slide the CARD STOPPER to the left. STEP 2: Tighten the screws of the CARD STOPPER as shown below. NOTE: When sliding the PIM CARD STOPPER, loosen all of the screws securing the PIM CARD STOPPER and the PZ-M542/PZ-M557 card (the screws need not to be re- moved). Figure 2-106 Installation of the CARD STOPPER CARD STOPPER CARD STOPPER CIRCUIT CARD CIRCUIT CARD SLIDE THE CARD STOPPER TO THE LEFT.SCREWSCREW
CHAPTER 2 INSTALLATION System Initialization NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 201 SYSTEM INITIALIZATION There are two methods for System Initialization. The first method is to Clear All Data, except LEN000 as a CAT terminal, then program the System Data. The second method is to use the Resident System Program, which causes the sys- tem to configure itself automatically to the default settings, wherever the line/ trunk cards are installed. NOTE 1: See CHAPTER 3 for MP switch settings. Page 209 NOTE 2: Refer to the Command Manual for default settings on the Resident System Program. All Clear, Except LEN000 CAT STEP 1: Turn on the “SW1” switch on all the PZ-PW121 cards. -The “ON” lamp must be lit on all the PZ-PW121 cards. STEP 2: On the MP Card, set SW3 to “B” and press SW1. STEP 3: When the “MN” lamp on the system is lit, set SW3 to the “0” position and press SW1. - The operating mode has been changed to the ON LINE mode. Resident System Program STEP 1: Mount the line/trunk cards into PIM. STEP 2: Turn on the “SW1” switch on all the PZ-PW121 cards. -The “ON” lamp must be lit on all the PZ-PW121 cards. STEP 3: On the MP card, set SW3 to “C” and press SW1. - After 30 to 40 seconds, the “MN” lamp turns on. - The system has loaded the Resident System Program. NOTE: If the “MJ” lamp is lit, repeat Step 3. STEP 4: On the MP card, set SW3 to the “0” position and press SW1. - The operating mode has been changed to the ON LINE mode. AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 2 INSTALLATION System Data Entry NEAX2000 IVS2 Installation Procedure ManualPage 202ND-70928 (E), Issue 1.0 SYSTEM DATA ENTRY There are two methods for data entry, using a Customer Administration Terminal (CAT) or a Maintenance Administration Terminal (MAT). NOTE: For assigning system data, refer to the Command Manual. CAT Any Dterm can be assigned as a CAT through programming. The Dterm can still be used as a reg- ular telephone when it is not in CAT mode. If the system is initialized by “C” (Resident System Program), every D term will be able to go into CAT mode. If the system is initialized by “B” (All Clear), only LEN000 is assigned as a CAT port (the DLC card must be installed in slot LT00). To use a D term as a CAT, follow the procedures shown below. NOTE: It is necessary to complete steps 1 through 6 within 4 seconds. To set CAT mode: 1. Press or 2. Press or - CNF/Conf lamp flashes 3. Press - CNF/Conf lamp is off 4. Press or 5. Press or - CNF/Conf lamp flashes 6. Press - CNF/Conf, SPKR/Speaker, FNC/Feature lamps are lit -“CAT MODE” is displayed on the LCD 7. Press or -“COMMAND = -” is displayed on the LCD AT T E N T I O NContents Static Sensitive Handling Precautions Required TRFTr a n s f e r CNFConf * TRFTr a n s f e r CNFConf # LNR/SPDRedial
CHAPTER 2 INSTALLATION MAT NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 203 To reset CAT mode: While “COMMAND = -” is displayed on the LCD: 1. Lift the handset (off hook) - SPKR/Speaker lamp turns off. 2. Restore the handset (on hook) - CNF/Conf, FNC/Feature lamps turn off. - LCD returns to clock. MAT Refer to the MATWorX User Guide. Cofirming Lamp Indication After system data entry, confirm proper operation of the system using indicator lamps. RUN Lamp Flashing (120 IPM) Check that the RUN lamps of PN-CP14 card and other application circuit cards are flashing. ON Lamps of All PZ-PW121 Cards Lightning Check that the ON lamps of all the PZ-PW121 cards are lightning and their MJ/MN lamps have gone out. BL Lamps Gone Out Check that the BL lamps of all the line/trunk circuit cards have gone out. If BL lamps are flashing, it means that the corresponding circuit is in make-busy state or the system data for this card is not assigned. For more details of lamp indication, see CHAPTER 3. For information of maintenance servicing and troubleshooting of the equipment, refer to the Maintenance Manual. AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 2 INSTALLATION Operation Test NEAX2000 IVS2 Installation Procedure ManualPage 204ND-70928 (E), Issue 1.0 OPERATION TEST Confirm the entered system data and hardware, including cable connection, by completing the following operational tests. Basic Connection Test at MDF Station Line Test (Operator Call from all stations) Central Office Trunk Test (Incoming, Outgoing) Tie Line Trunk Test (Incoming, Outgoing) Service Feature Test Call Transfer Step Call Executive Right of Way (Executive Override) Call Hold Call Back Call Forwarding-All Calls/Don’t Answer (No Answer)/Busy Line Call Pickup Station Hunting-Pilot/Circular Speed Calling-Station/System (Station Speed Dial/System Speed Dial) Paging Access (External Paging with Meet-me) Announcement Service Other selected features NOTE: Feature names in parentheses are for North America.