    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-DAIA (DAI)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 255
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    NOTE 1:
    Set the groove on the switch to the desired position.
    NOTE 2:
    When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
    ging the circuit card. SW3 (DIP SW)
    1Set the equalizer according to the 
    cable length between the system 
    and the CSU.
    OFF
    2
    OFF
    3
    OFF
    4 Always set to OFF
    JPS (Jumper pin)
    RightFor mounting this card on PIM1 -
    PIM7
    LeftFor mounting this card on PIM0
    JPR (Jumper pin)
    RightNeutral grounding on the receiving
    line is provided.
    Neutral grounding on the receiving
    line is not provided.
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    1
    23
    4ON
    ON
    SW
    -1SW
    -2SW
    -3CABLE
    LENGTH
    ON ON ON0 - 40m 
    (0-131.2ft.)
    ON ON OFF40 - 80m
    (131.2-262.5ft.)
    ON OFF ON80 - 120m
    (262.5-394ft.)
    ON OFF OFF120 - 160m
    (394-525ft.)
    OFF ON ON160 - 200m
    (525-656ft.)
    OFF OFF OFF Signal is not sent
    ON
    ON
    OFF
    Left 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-DAIA (DAI)
    NEAX2000 IVS2 Installation Procedure ManualPage 256ND-70928 (E), Issue 1.0
    NOTE 3:
    When clock source office signal is supplied via the line between the main site and the
    remote site, set the SW1-1 and SW1-2 as the following table. In this case, DAIA cards
    (DAIA0, DAIA1) must be mounted in PIM0.
    NOTE 4:
    The time slot number 0, 20, 21, and 22 (TS0/20/21/22) cannot be used for control sig-
    nal.
    NOTE 5:
    This setting must be identical with the opposite DAIB card.
    CONDITIONSDAIA0 DAIA1 DAIA2
    REMARKS
    SW
    1-1SW
    1-2SW
    1-1SW
    1-2SW
    1-1SW
    1-2
    One DAIA card 
    is provided.ON OFF––––The clock signal is 
    sent to PLO0 of MP 
    card via supply route 
    0 (DAIA0).
    Two or three 
    DAIA cards are 
    provided.ON OFF OFF ON OFF OFF The clock signal sup-
    ply route is automati-
    cally changed to the 
    route 1 (DAIA1), if a 
    transmission line fail-
    ure occurs on the 
    supply route 0. 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-DAIB (DAI)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 257
    PN-DAIB (DAI)
    Location of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    LINK Green Remains lit when a link between this card and a distant office is
    normally connected.
    Goes out after 15 seconds of link disconnection.
    RED Red Remains lit when detecting PCM signal loss or Frame Alignment 
    signal loss.
    RMT Red Remains lit when receiving the alarm signal from a distant office.
    LOOP–Not used
    BL Red Remains lit while data transmission on control channel (D ch).
    Flashes while FP data downloading.
    JPS
    JPR
     
    SW2
    SW3BUS
    CNSENSE
    RUN
    MB
    LINK 
    RED 
    RMT 
    LOOP 
    BL
    SW1 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-DAIB (DAI)
    NEAX2000 IVS2 Installation Procedure ManualPage 258ND-70928 (E), Issue 1.0
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    0-FAlways set to 0
    1-F Not used
    MB (Toggle SW)
    NOTE 1UP For make-busy
    For normal operation
    SW1
    (Piano Key SW)1 Always set to OFF
    2 Always set to OFF
    3 Always set to OFF
    4 Always set to OFF
    (Continued)
    0
    ON
    DOWN
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF
    OFF 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-DAIB (DAI)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 259
    SW2 (DIP SW)
    1ONControl channel signaling data 
    transmission speed: 48kbps
    Control channel signaling data 
    transmission speed: 64kbps
    2ONDTI frame configuration: 12-Multi 
    Fram e
    DTI frame configuration: 24-Multi 
    Fram e
    3ON Line code: AMI with ZCS
    Line code: B8ZS
    4ONSetting of control signal time slot
    NOTE 2, NOTE 3 5ON
    6ON
    7
    OFF
    8ON
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    1
    23
    45
    67
    8ONOFF
    OFF
    OFF
    SWITCH NUMBER
    TIME SLOT
    NUMBER
    45678
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    OFFON
    OFF
    OFF
    ON
    ON
    OFF
    OFF
    ON
    ON
    OFF
    OFF
    ON
    ON
    OFF
    OFF
    ON
    ON
    OFF
    OFF
    OFFON
    ON
    ON
    OFF
    OFF
    OFF
    OFF
    ON
    ON
    ON
    ON
    OFF
    OFF
    OFF
    OFF
    ON
    ON
    ON
    ON
    OFFON
    ON
    ON
    ON
    ON
    ON
    ON
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    ON
    ON
    ON
    ON
    ONON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    OFF
    OFF
    OFF
    OFF
    OFFTS1
    TS2
    TS3
    TS4
    TS5
    TS6
    TS7
    TS8
    TS9
    TS10
    TS11
    TS12
    TS13
    TS14
    TS15
    TS16
    TS17
    TS18
    TS19
    TS23
    OFF
    OFF
    OFF
    ON
    OFF 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-DAIB (DAI)
    NEAX2000 IVS2 Installation Procedure ManualPage 260ND-70928 (E), Issue 1.0
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    NOTE 1:
    When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
    ging the circuit card.
    NOTE 2:
    Time slot number 0, 20, 21, and 22 (TS0/20/21/22) can not be used for control signal.
    NOTE 3:
    This setting must be identical with the opposite DAIA card. SW3 (DIP SW)
    1Set the equalizer according to the 
    cable length between the system 
    and the CSU.
    OFF
    2
    OFF
    3
    OFF
    4 Always set to OFF
    JPS (Jumper pin)
    UPNeutral grounding on the transmit-
    ting line is provided.
    Neutral grounding on the transmit-
    ting line is not provided.
    JPR (Jumper pin)
    UPNeutral grounding on the receiving
    line is provided.
    Neutral grounding on the receiving
    line is not provided.
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    1
    23
    4ON
    ON
    SW
    -1SW
    -2SW
    -3CABLE
    LENGTH
    ON ON ON0 - 40m 
    (0-131.2ft.)
    ON ON OFF40 - 80m
    (131.2-262.5ft.)
    ON OFF ON80 - 120m
    (262.5-394ft.)
    ON OFF OFF120 - 160m
    (394-525ft.)
    OFF ON ON160 - 200m
    (525-656ft.)
    OFF OFF OFF Signal is not sent
    ON
    ON
    OFF
    DOWN
    DOWN 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-DAIC (DAI)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 261
    PN-DAIC (DAI)
    Location of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    LINK Green Remains lit when the following connection are normal.
    Control channel link between the DAIA card and DAIB card.
    Connection between the opposite DAIC card.
    Goes out after 15 seconds of link disconnection.
    RED Red Remains lit when detecting PCM signal loss or Frame Alignment
    signal loss.
    RMT Red Remains lit when receiving the alarm signal from a distant office.
    LOOP–Not used
    PWR–Not used
    BL–Not used
     
    SW2
    SW3TBUS
    RBUS
    CNRUN
    MB
    LINK 
    RED 
    RMT 
    LOOP 
    PWR 
    BL
    SW1 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-DAIC (DAI)
    NEAX2000 IVS2 Installation Procedure ManualPage 262ND-70928 (E), Issue 1.0
    Switch Settings
    SWITCHNAME SWITCH
    NUMBER SETTING
    POSITION FUNCTION CHECK
    MB (Toggle SW) 
    N
    OTE UP For make-busy
    For normal operation
    SW1  
    (Piano Key SW) 1 Always set to OFF 
    2 Always set to OFF 
    3 Always set to OFF 
    4 Always set to OFF
    SW2 (DIP SW) 1 Not used 
    2ON
    DTI frame configuration: 12-Multi  
    Fram e 
    DTI frame configuration: 24-Multi  
    Fram e
    3 ON Line code: AMI with ZCS
    Line code: B8ZS
    4 Not used 
    5 Not used
    6 Not used
    7 Not used
    8 Not used
    (Continued)
    ON
    DOWN
    4  
    3 
    2 
    1
    OFF
    ON
    OFF
    OFF
    OFF
    OFF
    1
    23
    45
    67
    8ON
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-DAIC (DAI)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 263
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    NOTE:
    When the power is on, flip MB switch to ON (UP position) before plugging/unplugging
    the circuit card.  SW3 (DIP SW)
    1Set the equalizer according to the 
    cable length between the system 
    and the CSU.
    OFF
    2
    OFF
    3
    OFF
    4ONWhen mounting this card on remote
    site.
    OFFWhen mounting this card on main
    site.
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    1
    23
    4ON
    ON
    SW
    -1SW
    -2SW
    -3CABLE
    LENGTH
    ON ON ON0 - 40m 
    (0-131.2ft.)
    ON ON OFF40 - 80m
    (131.2-262.5ft.)
    ON OFF ON80 - 120m
    (262.5-394ft.)
    ON OFF OFF120 - 160m
    (394-525ft.)
    OFF ON ON160 - 200m
    (525-656ft.)
    OFF OFF OFF Signal is not sent
    ON
    ON 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-DAID (DAI)
    NEAX2000 IVS2 Installation Procedure ManualPage 264ND-70928 (E), Issue 1.0
    PN-DAID (DAI)
    Location of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    LINK Green Remains lit when a link between this card and a distant office is
    normally connected.
    Goes out after 15 seconds of link disconnection.
    RMT Red Remains lit when receiving the alarm signal from a distant office.
    LOOP–Not used
    PWR Red Remains lit when detecting PCM signal loss.
    BL Red Remains lit while data transmission on control channel (D ch).
    Remains lit while FP data downloading. 
    SRT
    JPS E1Z
    JPR
     
    SW2
    SW3BUS
    PCM1
    PCM0
    CNSENSE
    RUN
    MB
    SW1LINK
    RMT 
    LOOP 
    PWR 
    BL
    JP 
    						