    							CHAPTER 2 INSTALLATION
    External Tone Source/Announcement Machine (DK/TNT/MP)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 175
    External Tone Source/Announcement Machine (DK/TNT/MP)
    (1) Requirement for Customer-owned External Tone Source/Announcement Machine
    Output level : Less than 0 dbm (Adjustable)
    Output impedance : Less than 1 kohms (When using PN-4COT/8COT and PN-DK00)
    : Less than 10 kohms (When using Pin Jacks on PN-TNTA)
    Control Method : Start - Ground Start  
    NOTE 1
    : Stop - Ground Off (Open)
    NOTE 1:The current capacity of relay contact (PN-DK00 card) is 0.125A.
    NOTE 2:When connecting the external tone source/announcement machine using the PN-
    4COT/8COT and PN-DK00 cards, an appropriate diode must be installed on the MDF,
    as shown in Figure 2-84. 
    						
    							CHAPTER 2 INSTALLATION
    External Tone Source/Announcement Machine (DK/TNT/MP)
    NEAX2000 IVS2 Installation Procedure ManualPage 176ND-70928 (E), Issue 1.0
    (2) Connection Outline
    Figure 2-84  External Tone Source/Announcement Machine Connection Outline
    JACK1
    External Tone Source/Announcement Machine
    PN-8COT 
    PN-DK00
    External Tone Source/Announcement Machine
    Diode *
    MDF
    PN-TNTA
    JACK0
    External Tone Source/Announcement Machine 
    When using PN-8COT and PN-DK00
    When using Pin Jacks on PN-TNTA
    PBX PBX
    * Rating for the Diode
     V
    R Less than –50V
     I
    O  More than 20mA
     V
    F Less than 1.0V
    PN-CP14
    JACKExternal Tone Source/Announcement Machine
    When using Pin Jack on PN-CP14
    PBX 
    						
    							CHAPTER 2 INSTALLATION
    External Tone Source/Announcement Machine (DK/TNT/MP)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 177
    (3) MDF Cross Connection
    Figure 2-85  MDF Cross Connection for External Tone Source/Announcement 
    Machine (1 of 2)
    29K7294
    K6428
    K5283
    K4327
    K32726
    K126
    2
    1K01
    K22LEN000
    LEN002
    PIM0
    P PN-DK00
    LT 0 0LT C 0
    J
    414116
    1640
    4015
    1534
    349
    9
    PN-8COT
    PZ-PW121
    MDF
    G
    Ring
    TipCONTROL
    CIRCUIT
    SPEECH
    PAT H
    CIRCUIT
    G
    LT 0 1
    T7
    R7
    T6
    R6
    T0
    R0
    LEN008 (No. 0)
    LEN014  (No. 6)
    LEN015  (No. 7)
    K0EXTERNAL TONE SOURCE/
    ANNOUNCEMENT MACHINE
    
    
    
    
    
    
    
    
     
    						
    							CHAPTER 2 INSTALLATION
    External Tone Source/Announcement Machine (DK/TNT/MP)
    NEAX2000 IVS2 Installation Procedure ManualPage 178ND-70928 (E), Issue 1.0
    Figure 2-85  MDF Cross Connection for External Tone Source/Announcement 
    Machine (2 of 2)
    26 1 K0
    27 2
    28 3
    29 4
    LT C 0  ( J )
    1K026
    227
    328
    429
    LT C 0  ( P )
    LEN008
    LEN009
    LEN015
    LEN016
    LEN000
    LEN002
    34 T0 9 R0
    35 T1 10 R1
    40 T6 14 R6
    41 T7 15 R7 9R034T0
    10 R1 35 T1
    14 R6 40 T6
    15 R7 41 T7
    
    
    
    
    
    
    
    
    
    
     
    
    
    
    
    
    
    
     
    						
    							CHAPTER 2 INSTALLATION
    External Tone Source/Announcement Machine (DK/TNT/MP)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 179
    If a D.C. voltage is supplied with the tone from the external tone source/announcement ma-
    chine, a transformer or coupling capacitor should be used as shown below.
    Figure 2-86  Connecting External Tone Source/Announcement Machine Supplied 
    with D.C.
    TO  P B XTO  C OTRing
    Tip
    KTRANSFORMER
    SOURCE
    CAPACITOR
    SOURCE
    TO  C OT
    Tip
    K Ring
    TO CONTROL CIRCUIT
    FROM PN-DK00
    2µF
    TO  P B XTO CONTROL CIRCUIT
    FROM PN-DK00CAPACITOR
    2µF
    R
    R
    EXTERNAL TONE SOURCE/
    EXTERNAL TONE SOURCE/DC
    VOLTAGE
    SOURCE
    DC
    VO LTAG E
    SOURCE ANNOUNCEMENT MACHINE
    ANNOUNCEMENT MACHINE 
    						
    							CHAPTER 2 INSTALLATION
    External BGM Source (COT/TNT/MP)
    NEAX2000 IVS2 Installation Procedure ManualPage 180ND-70928 (E), Issue 1.0
    External BGM Source (COT/TNT/MP)
    The system can connect a maximum of 10 customer-owned BGM sources.
    (1) Connection Outline
    Figure 2-87  External BGM Sources Connection Outline
    
    When using PN-8COT
    
    When using Pin Jacks on PN-TNTA
    
    When using Pin Jack on PN-CP14
    BGM SOURCE
    PN-8COT
    #0
    #1 BGM SOURCE
    BGM SOURCE
    MDF
    BGM SOURCE
    PN-TNTA
    JACK1
    JACK0#0
    #1 BGM SOURCE
    BGM SOURCE
    PN-CP14
    JACK
    BGM SOURCE 
    						
    							CHAPTER 2 INSTALLATION
    External BGM Source (COT/TNT/MP)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 181
    (2) MDF Cross Connection
    
    When using PN-8COT
    Figure 2-88  MDF Cross Connection for External BGM Sources
    LT C 0  ( P )LT C 0  ( J )
    BGM SOURCE
    #0
    33338
    832
    327
    727
    2726
    26
    2 1
    MDF
    1
    2
    PIM0
    P PN-8COT
    LT 0 0LT C 0
    J
    T7
    R7
    T6
    R6
    T1
    T0
    R0
    R1
    LEN000    (No. 0)
    LEN001    (No. 1)
    LEN006    (No. 6)
    LEN007    (No. 7)
    BGM SOURCE
    0
    1
    
    
    
    
    
    
    
    
    
    LEN000
    LEN001
    LEN006
    LEN00726 T0 1 R0
    27 T1 2 R1
    32 T6 7 R6
    33 T7 8 R7
    1R026T0
    2R127T1
    7R632T6
    8R733T7
    
    
    
    
    
    
    
    
    
    
     
    
    
    
    
    
    
    
     
    						
    							CHAPTER 2 INSTALLATION
    Power Failure Transfer (AUC)
    NEAX2000 IVS2 Installation Procedure ManualPage 182ND-70928 (E), Issue 1.0
    Power Failure Transfer (AUC)
    (1) Connection Outline
    Figure 2-89  PFT Connection Outline (AUC)
    MDF TEL
    PN-AUCPBX
    MDF
    PN-4COTTO C.O. LINE 
    						
    							CHAPTER 2 INSTALLATION
    Power Failure Transfer (AUC)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 183
    (2) MDF Cross Connection
    Figure 2-90  MDF Cross Connection for PFT (AUC) (1 of 2)
    NOTE 1:
    The No. 2 and No. 3 circuit in the PN-4COT card cannot be used for PFT function.
    NOTE 2:
    When using Ground Start trunks with PFT function, the single line stations must have
    a ground sending button and a ground lead must be run to the station.
    1
    26
    2
    27
    3
    28
    4
    29
    9
    34
    10
    35
    C.O.R0
    C.O.T0
    C.O.R1
    C.O.T1 PN-4COT1
    26
    2
    27
    3
    28
    4
    29
    TO
    STATIONSta. R0
    Sta. T0
    Sta. R1
    Sta. T1
    MDF PIM0
    PN-AUC LT 0 0
    9
    34
    10
    35
    JPLT C 0
    4Q-TW-0.3 CONN CA
    LT 0 1
    LEN000 (No. 0)
    LEN001 (No. 1)
    CN1
    04
    03
    02
    01
    CN1 04
    03
    02
    01LEN008 (No. 0)
    LEN009 (No. 1)
    Ring
    TO
    STATION Tip
    Tip Ring
    TO
    C.O. LINE
    TO
    C.O. LINE Ring
    Ring Tip
    Tip 
    						
    							CHAPTER 2 INSTALLATION
    Power Failure Transfer (AUC)
    NEAX2000 IVS2 Installation Procedure ManualPage 184ND-70928 (E), Issue 1.0
    Figure 2-90  MDF Cross Connection for PFT (AUC) (2 of 2)
    26 C.O.T0 1 C.O.R0
    27 C.O.T1 2 C.O.R1
    LT C 0  ( J )
    1 C.O.R0 26 C.O.T0
    2 C.O.R1 27 C.O.T1
    LT C 0  ( P )
    LEN008
    LEN009
    LEN000
    LEN001
    34 Sta.T0 9 Sta.R0
    35 Sta.T1 10 Sta.R1
    36 11
    37 12 9 Sta.R0 34 Sta.T0
    10 Sta.R1 35 Sta.T1
    11 36
    12 37 
    						