CHAPTER 2 INSTALLATION Power Failure Transfer (8PFT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 185 Power Failure Transfer (8PFT) (1) Connection Outline Figure 2-91 PFT Connection Outline (8PFT) NOTE:Using the PN-AUCA card (long line card) instead of the PN-8LC card is not recom- mended due to the variations from Central Office to the PBX; line quality cannot be as- sured. PZ-8PFTB PBX MDF MDFMDF MDF TO C.O. LINE PN-8LC PN-8COT TEL NOTE
CHAPTER 2 INSTALLATION Power Failure Transfer (8PFT) NEAX2000 IVS2 Installation Procedure ManualPage 186ND-70928 (E), Issue 1.0 (2) Installation of PZ-8PFTB STEP 1: Mount the PZ-8PFTB card into the PFT slot of the PIM. STEP 2: Connect the champ connectors of 25-pair cables to the PFT0 and PFT1 connectors on the PZ-8PFTB card as shown below. Figure 2-92 Connection of 25-Pair Cable and PZ-8PFTB PFT1 CONNECTOR CHAMP CONNECTOR ATTACHED TO PZ-8PFTB 25-PAIR CABLE To M D F (SEE STEP 3) PFT0 CONNECTOR PZ-8PFTB Page 187
CHAPTER 2 INSTALLATION Power Failure Transfer (8PFT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 187 STEP 3: Connect the 25-pair cables on the MDF. This figure shows the PFT connector pin assignment for each PFT circuit number (No. 0 - No. 7). Figure 2-93 PFT Connector Pin Assignment PFT0 1 Sta. R0 26 Sta. T0 2 8LC. R0 27 8LC. T0 3 C.O. R0 28 C.O. T0 4 8COT. R0 29 8COT. T0 5 Sta. R1 30 Sta. T1 6 8LC. R1 31 8LC. T1 7 C.O. R1 32 C.O. T1 8 8COT. R1 33 8COT. T1 9 Sta. R2 34 Sta. T2 10 8LC. R2 35 8LC. T2 11 C.O. R2 36 C.O. T2 12 8COT. R2 37 8COT. T2 13 Sta. R3 38 Sta. T3 14 8LC. R3 39 8LC. T3 15 C.O. R3 40 C.O. T3 16 8COT. R3 41 8COT. T3 17 Sta. R4 42 Sta. T4 18 8LC. R4 43 8LC. T4 19 C.O. R4 44 C.O. T4 20 8COT. R4 45 8COT. T4 21 Sta. R5 46 Sta. T5 22 8LC. R5 47 8LC. T5 23 C.O. R5 48 C.O. T5 24 8COT. R5 49 8COT. T5 25 50PFT1 1 Sta. R6 26 Sta. T6 2 8LC. R6 27 8LC. T6 3 C.O. R6 28 C.O. T6 4 8COT. R6 29 8COT. T6 5 Sta. R7 30 Sta. T7 6 8LC. R7 31 8LC. T7 7 C.O. R7 32 C.O. T7 8 8COT. R7 33 8COT. T7 934 10 35 11 36 12 37 13 38 14 39 15 40 16 41 17 42 18 43 19 44 20 45 21 46 22 47 23 48 24 49 E 25 50–27V o. 6 o. 7No. 6 No. 7 No. 0 No. 1 No. 3 No. 2 No. 5 No. 4
CHAPTER 2 INSTALLATION Power Failure Transfer (8PFT) NEAX2000 IVS2 Installation Procedure ManualPage 188ND-70928 (E), Issue 1.0 This figure shows MDF cross connection for No. 0 circuit on the PZ-8PFTB. Figure 2-94 MDF Cross Connection for PFT (8PFT) (1 of 2) TO STATION 272 338 261 272 261 338 JP PIM0 LT 0 0 35 41 349 35 349 41 T1LEN009 (No. 1)R1 T0LEN008 (No. 0)R0 T7LEN015 (No. 7)R7 PN-8COT LT 0 1 T1LEN001 (No. 1)R1 T0LEN000 (No. 0)R0 T7LEN007 (No. 7)R7 PN-8LC PZ-PW121 –27V G261 Sta. R0 Sta. T0 283 C.O. R0 C.O. T0 294 8COT. R0 8COT. T0 272 8LC. R0 8LC. T0PFT0 TO C. O. L IN E PZ-8PFTB No. 0 PJ PFT1 49 24 50 25 –27V E PJ Tip Ring Tip Ring MDF INSTALLATION CABLE LT C 0 10 10 16 16
CHAPTER 2 INSTALLATION Power Failure Transfer (8PFT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 189 Figure 2-94 MDF Cross Connection for PFT (8PFT) (2 of 2) 3LTC0 CONNECTOR 2 PFT1 CONNECTOR 24 49 E 25 50–27V49 E 24 50–27V 25 PFT1 (J) 26 Sta. T0 1 Sta. R0 27 8LC. T0 2 8LC. R0 28 C.O. T0 3 C.O. R0 29 8COT. T0 4 8COT. R0 1 Sta. R0 26 Sta. T0 2 8LC. R0 27 8LC. T0 3 C.O. R0 28 C.O. T0 4 8COT. R0 29 8COT. T0 PFT0 (P) TO S TAT IO N TO P N - 8 L C TO C.O. L IN E TO P N - 8 C OT PFT0 (J) PFT1 (P) 1 PFT0 CONNECTOR TO PZ-PW121 26 T0 1 R0 27 2 28 3 29 4 LT C 0 ( J ) LEN000 LEN008 1R026T0 227 328 429 LT C 0 ( P ) TO PZ-8PFTB TO PZ-8PFTB34 T0 9 R0 35 10 36 11 37 12 9R034T0 10 35 11 36 12 37
CHAPTER 2 INSTALLATION Alarm Display Panel (MP) NEAX2000 IVS2 Installation Procedure ManualPage 190ND-70928 (E), Issue 1.0 Alarm Display Panel (MP) Figure 2-95 MDF Cross Connection for Alarm Display Panel REAR ALARM DISPLAY PANEL 26 1 50 MN 25 MJ LT C 0 ( J ) 126 25 MJ 50 MN LT C 0 ( P ) PWRMJMIN FRONT25 5025 50MJ MN –27V GPN-CP14PIM0 MDF LT C 0 P J PZ-PW121
CHAPTER 2 INSTALLATION Built-in SMDR (MP) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 191 Built-in SMDR (MP) The MP card provides a RS-232C interface port for SMDR connection. No.0 Port : Async.: 1200/2400/4800/9600/19200 bps Direct connection Connect the SMDR terminal to the RS 0 Port of the PN-CP14 card using the RS RVS-15 (S) CA-A/RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C as shown below. Figure 2-96 SMDR Terminal Direct Connection Connection via MODEM When the cable length between the PBX and the terminal is more than 15 m (49.2 ft.), con- nect the SMDR terminal to the RS0 Port of the PN-CP14 card through the MODEMs using the RS NORM-4 (S) CA-A as shown below. Figure 2-97 SMDR Terminal Connection via MODEMs PN-CP14 RS 0 RS RVS-15 (S) CA-A: 15 m (49.2 ft.) PBX 15 m (49.2 ft.) MAX. TO RS-232C PORT SMDR RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C: 4 m (13.1 ft.) PN-CP14 RS 0 PBX MODEM MODEM 2P RS NORM-4 CA-A/ RS NORM-4S CA-A: 4 m (13.1 ft.) MORE THAN 15 m (49.2 ft.)MODEM INTERFACE CABLE (STRAIGHT) TO RS-232C PORT SMDR
CHAPTER 2 INSTALLATION Built-in SMDR (MP) NEAX2000 IVS2 Installation Procedure ManualPage 192ND-70928 (E), Issue 1.0 Figure 2-98 RS RVS-15 CA-A/RS RVS-15S CA-A/ RS RVS-4 CA-A/RS RVS-4 CA-C/ RS RVS-4S CA-A/RS RVS-4S CA-C NOTE: If the SMDR terminal does not send DTR or RTS signal, cut the signal lead marked by X in the D-Sub connector (SMDR terminal side) as shown in the wiring diagram above. See Table 2-7. 05A-TXD 05B-GND 06A-TXC (2) 06A-TXC (2) 06B-RXC 06D-TXC (1) 04B-RXD 04A-RTS 03-RXD 01-GND 06-DSR 24-TXC (1) 17-RXC 02-TXD 08-DCD 15-TXC (2) 02B-GND 03A-DSR 03B-CTS 02A-DCD 01C-LALB 07-GND 20-DTR 05-CTS 04-RTS 18-LALB DC B A 06 TXC (1) RXC TXC (2) 05 DTR GND TXD 04 (RT) RXD RTS 03 (ST) CTS DSR 02 ---- GND DCD 01 LALB G 13 ---- 12 ---- 11 ---- 10 ---- 09 ---- 08 DCD 07 GND 06 DSR 05 CTS 04 RTS 03 RXD 02 TXD 25 ---- 24 TXC (1) 23 ---- 22 ---- 21 ---- 20 DTR 19 ---- 18 LALB 17 RXC 16 ---- 15 TXC (2) 14 ----01 GND X NOTE X X X X X XXG: GROUND RS RVS-15 CA-A/RS RVS-15S CA-A: 15 m (49.2 ft.) MAX. X RS RVS-4 CA-A/RS RVS-4 CA-C/ RS RVS-4S CA-A/RS RVS-4S CA-C: 4 m (13.1 ft.) MAX.
CHAPTER 2 INSTALLATION Built-in SMDR (MP) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 193 Figure 2-99 RS NORM-4 CA-A/RS NORM-4S CA-A See Table 2-7. 05A-TXD 05B-GND 0 5C-DTR 06A-TXC (2) 06B-RXC 06D-TXC (1) 04B-RXD 04A-RTS 02-TXD 01-GND 20-DTR 15-TXC (2) 17-RXC 03-RXD 04-RTS 24-TXC (1) 02B-GND 03A-DSR 03B-CTS 02A-DCD 01C-LALB 07-GND 06-DSR 05-CTS 08-DCD 18-LALB DC B A 06 TXC (1) X RXC TXC (2) 05 X DTR GND TXD 04 (RT) X RXD RTS 03 X (ST) CTS DSR 02 ---- X GND DCD 01 X LALB X G 13 ---- 12 ---- 11 ---- 10 ---- 09 ---- 08 DCD 07 GND 06 DSR 05 CTS 04 RTS 03 RXD 02 TXD 25 ---- 24 TXC (1) 23 ---- 22 ---- 21 ---- 20 DTR 19 ---- 18 LALB 17 RXC 16 ---- 15 TXC (2) 14 ----01 GND 4 m (13.1 ft.) MAX. G: GROUND
CHAPTER 2 INSTALLATION SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00) NEAX2000 IVS2 Installation Procedure ManualPage 194ND-70928 (E), Issue 1.0 SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00) The PN-AP00-B card provides 4 RS-232C interface ports for SMDR, PMS, MCI, CIS Printer, Ho- tel Printer. (1) SMDR/PMS/MCI (VMS) Direct Connection Connect the terminal to the RS0-RS3 port of the PN-AP00-B card using the RS RVS-15 (S) CA-A/RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C as shown below. See also Figure 2-98. Figure 2-100 SMDR/PMS/MCI Terminal Direct Connection PBX (PIM0 - PIM7) PN-RS0 - RS3 15 m (49.2 ft.) MAX. RS RVS-15 (S) CA-A : 15 m (49.2 ft.) SMDR0/SMDR1/ TO RS-232C PORT AP00-B PMS/MCI (VMS) RS RVS-4 (S) CA-A/RS R VS-4 (S) CA-C: 4 m (13.1 ft.)