    							CHAPTER 2 INSTALLATION
    Power Failure Transfer (8PFT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 185
    Power Failure Transfer (8PFT)
    (1) Connection Outline
    Figure 2-91  PFT Connection Outline (8PFT)
    NOTE:Using the PN-AUCA card (long line card) instead of the PN-8LC card is not recom-
    mended due to the variations from Central Office to the PBX; line quality cannot be as-
    sured.
    PZ-8PFTB
    PBX
    MDF MDFMDF MDF
    TO C.O. 
    LINE PN-8LC PN-8COT
    TEL
    NOTE 
    						
    							CHAPTER 2 INSTALLATION
    Power Failure Transfer (8PFT)
    NEAX2000 IVS2 Installation Procedure ManualPage 186ND-70928 (E), Issue 1.0
    (2) Installation of PZ-8PFTB
    STEP 1: Mount the PZ-8PFTB card into the PFT slot of the PIM.
    STEP 2: Connect the champ connectors of 25-pair cables to the PFT0 and PFT1 connectors on
    the PZ-8PFTB card as shown below.
    Figure 2-92  Connection of 25-Pair Cable and PZ-8PFTB
    PFT1 CONNECTOR
    CHAMP CONNECTOR ATTACHED TO PZ-8PFTB 
    25-PAIR CABLE
    To  M D F  
    (SEE STEP 3) PFT0 CONNECTOR PZ-8PFTB
       Page 187 
    						
    							CHAPTER 2 INSTALLATION
    Power Failure Transfer (8PFT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 187
    STEP 3: Connect the 25-pair cables on the MDF.
    
    This figure shows the PFT connector pin assignment for each PFT circuit number
    (No. 0 - No. 7).
    Figure 2-93  PFT Connector Pin Assignment
    PFT0
    1 Sta. R0 26 Sta. T0
    2 8LC. R0 27 8LC. T0
    3 C.O. R0 28 C.O. T0
    4 8COT. R0 29 8COT. T0
    5 Sta. R1 30 Sta. T1
    6 8LC. R1 31 8LC. T1
    7 C.O. R1 32 C.O. T1
    8 8COT. R1 33 8COT. T1
    9 Sta. R2 34 Sta. T2
    10 8LC. R2 35 8LC. T2
    11 C.O. R2 36 C.O. T2
    12 8COT. R2 37 8COT. T2
    13 Sta. R3 38 Sta. T3
    14 8LC. R3 39 8LC. T3
    15 C.O. R3 40 C.O. T3
    16 8COT. R3 41 8COT. T3
    17 Sta. R4 42 Sta. T4
    18 8LC. R4 43 8LC. T4
    19 C.O. R4 44 C.O. T4
    20 8COT. R4 45 8COT. T4
    21 Sta. R5 46 Sta. T5
    22 8LC. R5 47 8LC. T5
    23 C.O. R5 48 C.O. T5
    24 8COT. R5 49 8COT. T5
    25 50PFT1
    1 Sta. R6 26 Sta. T6
    2 8LC. R6 27 8LC. T6
    3 C.O. R6 28 C.O. T6
    4 8COT. R6 29 8COT. T6
    5 Sta. R7 30 Sta. T7
    6 8LC. R7 31 8LC. T7
    7 C.O. R7 32 C.O. T7
    8 8COT. R7 33 8COT. T7
    934
    10 35
    11 36
    12 37
    13 38
    14 39
    15 40
    16 41
    17 42
    18 43
    19 44
    20 45
    21 46
    22 47
    23 48
    24 49 E
    25 50–27V
    o. 6
    o. 7No. 6
    No. 7
    No. 0
    No. 1
    No. 3
    No. 2
    No. 5
    No. 4 
    						
    							CHAPTER 2 INSTALLATION
    Power Failure Transfer (8PFT)
    NEAX2000 IVS2 Installation Procedure ManualPage 188ND-70928 (E), Issue 1.0
    
    This figure shows MDF cross connection for No. 0 circuit on the PZ-8PFTB.
    Figure 2-94  MDF Cross Connection for PFT (8PFT) (1 of 2)
    TO STATION
    272
    338
    261
    272 261
    338 JP PIM0
    LT 0 0
    35
    41
    349
    35 349
    41
    T1LEN009
    (No. 1)R1
    T0LEN008
    (No. 0)R0
    T7LEN015
    (No. 7)R7
    PN-8COT
    LT 0 1
    T1LEN001
    (No. 1)R1
    T0LEN000
    (No. 0)R0
    T7LEN007
    (No. 7)R7
    PN-8LC
    PZ-PW121
    –27V
    G261 Sta. R0
    Sta. T0
    283 C.O. R0
    C.O. T0
    294 8COT. R0
    8COT. T0
    272 8LC. R0
    8LC. T0PFT0
    TO  C. O. L IN E
    PZ-8PFTB
    No. 0
    PJ
    PFT1
    49
    24
    50 25
    –27V E
    PJ
    Tip
    Ring
    Tip
    Ring MDF
    INSTALLATION CABLE LT C 0
    10 10
    16
    16
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
    
     
    						
    							CHAPTER 2 INSTALLATION
    Power Failure Transfer (8PFT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 189
    Figure 2-94  MDF Cross Connection for PFT (8PFT) (2 of 2)
    3LTC0 CONNECTOR
    2 PFT1 CONNECTOR
    24 49 E
    25 50–27V49 E 24
    50–27V 25
    PFT1 (J)
    26 Sta. T0 1 Sta. R0
    27 8LC. T0 2 8LC. R0
    28 C.O. T0 3 C.O. R0
    29 8COT. T0 4 8COT. R0 1 Sta. R0 26 Sta. T0
    2 8LC. R0 27 8LC. T0
    3 C.O. R0 28 C.O. T0
    4 8COT. R0 29 8COT. T0 
    PFT0 (P)
    TO  S TAT IO N
    TO  P N - 8 L C
    TO  C.O. L IN E
    TO  P N - 8 C OT
    PFT0 (J)
    PFT1 (P)
    1 PFT0 CONNECTOR
    TO PZ-PW121
    26 T0 1 R0
    27 2
    28 3
    29 4
    LT C 0  ( J )
    LEN000
    LEN008
    1R026T0
    227
    328
    429
    LT C 0  ( P )
    TO PZ-8PFTB
    TO PZ-8PFTB34 T0 9 R0
    35 10
    36 11
    37 12 9R034T0
    10 35
    11 36
    12 37 
    						
    							CHAPTER 2 INSTALLATION
    Alarm Display Panel (MP)
    NEAX2000 IVS2 Installation Procedure ManualPage 190ND-70928 (E), Issue 1.0
    Alarm Display Panel (MP)
    Figure 2-95  MDF Cross Connection for Alarm Display Panel
    REAR
    ALARM DISPLAY PANEL
    26 1
    50 MN 25 MJ
    LT C 0  ( J )
    126
    25 MJ 50 MN
    LT C 0  ( P )
    PWRMJMIN
    FRONT25
    5025
    50MJ
    MN
    –27V
    GPN-CP14PIM0 MDF
    LT C 0
    P J
    PZ-PW121 
    						
    							CHAPTER 2 INSTALLATION
    Built-in SMDR (MP)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 191
    Built-in SMDR (MP)
    The MP card provides a RS-232C interface port for SMDR connection.
    No.0 Port : Async.: 1200/2400/4800/9600/19200 bps
    
    Direct connection
    Connect the SMDR terminal to the RS 0 Port of the PN-CP14 card using the RS RVS-15 (S)
    CA-A/RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C as shown below.
    Figure 2-96  SMDR Terminal Direct Connection
    
    Connection via MODEM
    When the cable length between the PBX and the terminal is more than 15 m (49.2 ft.), con-
    nect the SMDR terminal to the RS0 Port of the PN-CP14 card through the MODEMs using 
    the RS NORM-4 (S) CA-A as shown below.
    Figure 2-97  SMDR Terminal Connection via MODEMs
    PN-CP14
    RS 0
    RS RVS-15 (S) CA-A: 15 m (49.2 ft.)
    PBX
    15 m (49.2 ft.) MAX.
    TO RS-232C
    PORT
    SMDR
    RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C: 4 m (13.1 ft.)
    PN-CP14
    RS 0
    PBX
    MODEM
    MODEM
    2P
    RS NORM-4 CA-A/
    RS NORM-4S CA-A: 4 m (13.1 ft.)
    MORE THAN 15 m (49.2 ft.)MODEM INTERFACE
    CABLE (STRAIGHT)
    TO RS-232C
    PORT
    SMDR 
    						
    							CHAPTER 2 INSTALLATION
    Built-in SMDR (MP)
    NEAX2000 IVS2 Installation Procedure ManualPage 192ND-70928 (E), Issue 1.0
    Figure 2-98  RS RVS-15 CA-A/RS RVS-15S CA-A/
    RS RVS-4 CA-A/RS RVS-4 CA-C/
    RS RVS-4S CA-A/RS RVS-4S CA-C
    NOTE:
    If the SMDR terminal does not send DTR or RTS signal, cut the signal lead marked by
    X in the D-Sub connector (SMDR terminal side) as shown in the wiring diagram above.
    See Table 2-7.
    05A-TXD
    05B-GND
    06A-TXC (2)
    06A-TXC (2)
    06B-RXC
    06D-TXC (1)
    04B-RXD
    04A-RTS
    03-RXD
    01-GND
    06-DSR
    24-TXC (1)
    17-RXC
    02-TXD
    08-DCD
    15-TXC (2)
    02B-GND
    03A-DSR
    03B-CTS
    02A-DCD
    01C-LALB
    07-GND
    20-DTR
    05-CTS
    04-RTS
    18-LALB
    DC B A
    06 TXC (1) RXC TXC (2)
    05 DTR GND TXD
    04 (RT) RXD RTS
    03 (ST) CTS DSR
    02 ---- GND DCD
    01 LALB G
    13 ----
    12 ----
    11 ----
    10 ----
    09 ----
    08 DCD
    07 GND
    06 DSR
    05 CTS
    04 RTS
    03 RXD
    02 TXD
    25 ----
    24 TXC (1)
    23 ----
    22 ----
    21 ----
    20 DTR
    19 ----
    18 LALB
    17 RXC
    16 ----
    15 TXC (2)
    14 ----01 GND
    X NOTE
    X
    X
    X X
    X
    XXG: GROUND RS RVS-15 CA-A/RS RVS-15S CA-A: 15 m (49.2 ft.) MAX.
    X RS RVS-4 CA-A/RS RVS-4 CA-C/
    RS RVS-4S CA-A/RS RVS-4S CA-C: 4 m (13.1 ft.) MAX.  
    						
    							CHAPTER 2 INSTALLATION
    Built-in SMDR (MP)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 193
    Figure 2-99  RS NORM-4 CA-A/RS NORM-4S CA-A
    See Table 2-7.
    05A-TXD
    05B-GND
    0
    5C-DTR
    06A-TXC (2)
    06B-RXC
    06D-TXC (1)
    04B-RXD
    04A-RTS
    02-TXD
    01-GND
    20-DTR
    15-TXC (2)
    17-RXC
    03-RXD
    04-RTS
    24-TXC (1)
    02B-GND
    03A-DSR
    03B-CTS
    02A-DCD
    01C-LALB
    07-GND
    06-DSR
    05-CTS
    08-DCD
    18-LALB
    DC B A
    06 TXC (1) X RXC TXC (2)
    05 X DTR GND TXD
    04 (RT) X RXD RTS
    03 X (ST) CTS DSR
    02 ---- X GND DCD
    01 X LALB X G
    13 ----
    12 ----
    11 ----
    10 ----
    09 ----
    08 DCD
    07 GND
    06 DSR
    05 CTS
    04 RTS
    03 RXD
    02 TXD
    25 ----
    24 TXC (1)
    23 ----
    22 ----
    21 ----
    20 DTR
    19 ----
    18 LALB
    17 RXC
    16 ----
    15 TXC (2)
    14 ----01 GND
    4 m (13.1 ft.) MAX.
    G: GROUND 
    						
    							CHAPTER 2 INSTALLATION
    SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
    NEAX2000 IVS2 Installation Procedure ManualPage 194ND-70928 (E), Issue 1.0
    SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
    The PN-AP00-B card provides 4 RS-232C interface ports for SMDR, PMS, MCI, CIS Printer, Ho-
    tel Printer.
    (1) SMDR/PMS/MCI (VMS)
    
    Direct Connection
    Connect the terminal to the RS0-RS3 port of the PN-AP00-B card using the RS RVS-15 (S) 
    CA-A/RS RVS-4 (S) CA-A/RS RVS-4 (S) CA-C as shown below. See also Figure 2-98.
    Figure 2-100  SMDR/PMS/MCI Terminal Direct Connection
    PBX
    (PIM0 - PIM7)
    PN-RS0 - RS3
    15 m (49.2 ft.) MAX. RS RVS-15 (S) CA-A : 15 m (49.2 ft.)
    SMDR0/SMDR1/ TO RS-232C PORT
    AP00-B
    PMS/MCI (VMS)
    RS RVS-4 (S) CA-A/RS R VS-4 (S) CA-C: 4 m (13.1 ft.) 
    						