CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC00 (CCH) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 305 Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-31) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2UP For make-busy For normal operation SW0 (Piano Key SW)1ON Loop-back test For normal operation 2ON Analog interface OFF Digital interface 3ONRS-232C RTS signal (to MODEM) ON NOTE 3 OFFRS-232C RTS signal (to MODEM) OFF 4ON AP No. 04-15 OFF AP No. 20-31 (Continued) F 4AP No.SW0-4: ON 04 05 06 07 08 09 10 11 12 13 14 15 SW0-4: OFF 20 21 22 23 24 25 26 27 28 29 30 31 SW No. 456789ABCDEF ON DOWN 4 3 2 1 OFF ON OFF
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC00 (CCH) NEAX2000 IVS2 Installation Procedure ManualPage 306ND-70928 (E), Issue 1.0 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. NOTE 3: This setting is available when SW0-2 is set to ON (Analog Interface). NOTE 4: The following two kinds of rate adaptation methods are available in 48 Kbps data trans- mission. The rate adaptation method must be set to match the rate adaptation of mas- ter office. SW1(DIP SW) 1ONCommon channel signalling data transmission speed (For Digital Interface) Common channel signalling data transmission speed (For Analog Interface) Set switches (SW1-1 - SW1-5) to OFF. OFF 2ON OFF 3ON OFF 4ON OFF 5ON OFF 6ON A-law OFFµ -law 7 Always set to OFF 8 Always set to OFF SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1 23 45 67 8ON TRANSMISSION SPEEDSW 1-1SW 1-2SW 1-3SW 1-4SW 1-5 48kbps NOTE 4 ON ON OFF OFF ON 48kbps NOTE4 ON ON ON OFF ON 56kbps ON ON OFF ON ON 64kbps ONONONONON OFF OFF 11 48kbps Data SW1-3: OFF 11 48kbps SW1-3: ON Data
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC01 (DCH) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 307 PN-SC01 (DCH) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. LC Green Remains lit when communications are normally ongoing with the D channel data links connected. LPB Green Not used SENSE RUN MB SW0 LC LPB SW1
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC01 (DCH) NEAX2000 IVS2 Installation Procedure ManualPage 308ND-70928 (E), Issue 1.0 Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-31) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2UP For make-busy For normal operation SW0 (Piano Key SW)1 Always set to OFF 2 Always set to OFF 3 Always set to OFF 4ON AP No. 04-15 OFF AP No. 20-31 (Continued) F 4 AP No.SW0-4: ON 04 05 06 07 08 09 10 11 12 13 14 15 SW0-4: OFF 20 21 22 23 24 25 26 27 28 29 30 31 SW No. 456789ABCDEF ON DOWN 4 3 2 1 OFF ON OFF OFF OFF
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC01 (DCH) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 309 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. SW1 (DIP SW) 1 Always set to OFF 2 Always set to OFF 3 Always set to OFF 4 Always set to OFF 5 Always set to OFF 6 Always set to OFF 7 Always set to OFF 8 Always set to OFF SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1 23 45 67 8ON OFF OFF OFF OFF OFF OFF OFF OFF
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC03 (ICH) NEAX2000 IVS2 Installation Procedure ManualPage 310ND-70928 (E), Issue 1.0 PN-SC03 (ICH) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. DOPE7 Green Remains lit when No. 7 circuit D channel link is connected. DOPE6 Green Remains lit when No. 6 circuit D channel link is connected. DOPE5 Green Remains lit when No. 5 circuit D channel link is connected. DOPE4 Green Remains lit when No. 4 circuit D channel link is connected. DOPE3 Green Remains lit when No. 3 circuit D channel link is connected. DOPE2 Green Remains lit when No. 2 circuit D channel link is connected. DOPE1 Green Remains lit when No. 1 circuit D channel link is connected. DOPE0 Green Remains lit when No. 0 circuit D channel link is connected. SENSE RUN MB DOPE7 DOPE6 DOPE5 DOPE4 DOPE3 DOPE2 DOPE1 DOPE0
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC03 (ICH) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 311 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-15) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2UP For make-busy For normal operation F 4AP No.04 05 06 07 08 09 10 11 12 13 14 15 SW No.456789ABCDEF ON DOWN
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC03-A (CSH) NEAX2000 IVS2 Installation Procedure ManualPage 312ND-70928 (E), Issue 1.0 PN-SC03-A (CSH) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. DOPE7 Green Remains lit when No. 7 circuit D channel link is connected. DOPE6 Green Remains lit when No. 6 circuit D channel link is connected. DOPE5 Green Remains lit when No. 5 circuit D channel link is connected. DOPE4 Green Remains lit when No. 4 circuit D channel link is connected. DOPE3 Green Remains lit when No. 3 circuit D channel link is connected. DOPE2 Green Remains lit when No. 2 circuit D channel link is connected. DOPE1 Green Remains lit when No. 1 circuit D channel link is connected. DOPE0 Green Remains lit when No. 0 circuit D channel link is connected. SENSE RUN MB DOPE7 DOPE6 DOPE5 DOPE4 DOPE3 DOPE2 DOPE1 DOPE0 SW1
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-SC03-A (CSH) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 313 Switch Settings The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-31) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2UP For make-busy For normal operation SW1 (Piano SW)1 Not used 2 Not used 3 Not used 4ON AP No. 04-15 OFF AP No. 20-31 F 4AP No.SW1-1: ON 04 05 06 07 08 09 10 11 12 13 14 15 SW1-1: OFF 20 21 22 23 24 25 26 27 28 29 30 31 SW No. 456789ABCDEF ON DOWN 4 3 2 1 OFF ON OFF OFF OFF
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PZ-M537 (EXPMEM) NEAX2000 IVS2 Installation Procedure ManualPage 314ND-70928 (E), Issue 1.0 PZ-M537 (EXPMEM) Locations of Lamps, Switches, and Connectors FA C E REAR CONNR: To CONN connector on PN-CP14 (MP) or PN-AP00-B (AP00) CONNR SW