    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-8COTQ (COT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 335
    PN-8COTQ (COT)
    Locations of Lamps, Switches, and Connectors 
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0-7 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL7
    BL6
    BL5
    BL4
    BL3
    BL2
    BL1
    BL0 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-8COTR (COT)
    NEAX2000 IVS2 Installation Procedure ManualPage 336ND-70928 (E), Issue 1.0
    PN-8COTR (COT)
    Locations of Lamps, Switches, and Connectors 
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0-7 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL7
    BL6
    BL5
    BL4
    BL3
    BL2
    BL1
    BL0 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-8COTS (COT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 337
    PN-8COTS (COT)
    Locations of Lamps, Switches, and Connectors 
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0-7 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL7
    BL6
    BL5
    BL4
    BL3
    BL2
    BL1
    BL0 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-8COTT (COT)
    NEAX2000 IVS2 Installation Procedure ManualPage 338ND-70928 (E), Issue 1.0
    PN-8COTT (COT)
    Locations of Lamps, Switches, and Connectors 
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0-7 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    LF0-7 RedRemains lit when the corresponding circuit detects a line fault 
    condition.
    BL7
    BL6
    BL5
    BL4
    BL3
    BL2
    BL1
    BL0
    LF7
    LF6
    LF5
    LF4
    LF3
    LF2
    LF1
    LF0 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2CSIA (CSI)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 339
    PN-2CSIA (CSI)
    Locations of Lamps, Swtiches, and Connectors
    OPE
    B13 LB
    B12
    B11
    B10
    B02 B03
    B01
    B00
    DL1
    DL0 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2CSIA (CSI)
    NEAX2000 IVS2 Installation Procedure ManualPage 340ND-70928 (E), Issue 1.0
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    OPE Green Remains lit when the corresponding circuit is in use.
    LB Red Remains lit when a loop-back is in progress.
    B13 Red Not used (Flash [60 IPM])
    B12 Red B channel status
    ON  :  B2 channel of the No. 1 circuit is in use.
    OFF :  B2 channel of the No. 1 circuit is idle.
    Flash (60 IPM) :  ZT is not connected to the No. 1 circuit.
    ZT is in make-busy status.
    B11 Red B channel status
    ON  :  B1 channel of the No. 1 circuit is in use.
    OFF :  B1 channel of the No. 1 circuit is idle.
    Flash (60 IPM) :  ZT is not connected to the No. 1 circuit.
    ZT is in make-busy status.
    B10 Red B channel status
    ON  :  B0 channel of the No. 1 circuit is in use.
    OFF  :  B0 channel of the No. 1 circuit is idle.
    Flash (60 IPM) :  ZT is not connected to the No. 1 circuit.
    ZT is in make-busy status.
    B03 Red Not used (Flash [60 IPM])
    B02 Red B channel status
    ON  :  B2 channel of the No. 0 circuit is in use.
    OFF  :  B2 channel of the No. 0 circuit is idle.
    Flash (60 IPM) :  ZT is not connected to the No. 0 circuit.
    ZT is in make-busy status.
    B01 Red B channel status
    ON  :  B1 channel of the No. 0 circuit is in use.
    OFF  :  B1 channel of the No. 0 circuit is idle.
    Flash (60 IPM) :  ZT is not connected to the No. 0 circuit.
    ZT is in make-busy status.
    (Continued) 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2CSIA (CSI)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 341
    Switch Settings
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION 
    column indicate the standard setting of the switch. When the switch is not set as shown by the 
    figure and   , the setting of the switch varies with the system concerned.
    NOTE:
    Set the groove on the switch to the desired position. B00 Red B channel status
    ON  :  B0 channel of the No. 0 circuit is in use.
    OFF  :  B0 channel of the No. 0 circuit is idle.
    Flash (60 IPM) :  ZT is not connected to the No. 0 circuit.
    ZT is in make-busy status.
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    DL0
    (Rotary SW)
    NOTE0-FFor normal operation
    1-F Not used
    DL1
    (Rotary SW)
    NOTE0-FFor normal operation
    1-F Not used
    LAMP 
    NAMECOLOR FUNCTION
    0
    0
    0
    0 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2CSIA-A (CSI)
    NEAX2000 IVS2 Installation Procedure ManualPage 342ND-70928 (E), Issue 1.0
    PN-2CSIA-A (CSI)
    Locations of Lamps, Swtiches, and Connectors
    OPE
    B13 LB
    B12
    B11
    B10
    B02 B03
    B01
    B00
    DL1
    DL0
    SP 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2CSIA-A (CSI)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 343
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    OPE Green Remains lit when the corresponding circuit is in use.
    LB Red Remains lit when a loop-back is in progress.
    B13 Red Not used (Flash [60 IPM])
    B12 Red B channel status
    ON  :  B2 channel of the No. 1 circuit is in use.
    OFF :  B2 channel of the No. 1 circuit is idle.
    Flash (60 IPM) :  CS is not connected to the No. 1 circuit.
    CS is in make-busy status.
    B11 Red B channel status
    ON  :  B1 channel of the No. 1 circuit is in use.
    OFF :  B1 channel of the No. 1 circuit is idle.
    Flash (60 IPM) :  CS is not connected to the No. 1 circuit.
    CS is in make-busy status.
    B10 Red B channel status
    ON  :  B0 channel of the No. 1 circuit is in use.
    OFF  :  B0 channel of the No. 1 circuit is idle.
    Flash (60 IPM) :  CS is not connected to the No. 1 circuit.
    CS is in make-busy status.
    B03 Red Not used (Flash [60 IPM])
    B02 Red B channel status
    ON  :  B2 channel of the No. 0 circuit is in use.
    OFF  :  B2 channel of the No. 0 circuit is idle.
    Flash (60 IPM) :  CS is not connected to the No. 0 circuit.
    CS is in make-busy status.
    B01 Red B channel status
    ON  :  B1 channel of the No. 0 circuit is in use.
    OFF  :  B1 channel of the No. 0 circuit is idle.
    Flash (60 IPM) :  CS is not connected to the No. 0 circuit.
    CS is in make-busy status.
    (Continued) 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2CSIA-A (CSI)
    NEAX2000 IVS2 Installation Procedure ManualPage 344ND-70928 (E), Issue 1.0
    Switch Settings
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION 
    column indicate the standard setting of the switch. When the switch is not set as shown by the 
    figure and   , the setting of the switch varies with the system concerned.
    NOTE:
    Set the groove on the switch to the desired position. B00 Red B channel status
    ON  :  B0 channel of the No. 0 circuit is in use.
    OFF  :  B0 channel of the No. 0 circuit is idle.
    Flash (60 IPM) :  CS is not connected to the No. 0 circuit.
    CS is in make-busy status.
    SWITCH NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    DL0
    (Rotary SW)
    NOTE0-FFor normal operation
    1-F Not used
    DL1
    (Rotary SW)
    NOTE0-FFor normal operation
    1-F Not used
    SP (jumper SW)
    For normal operation
    DOWN Not used
    LAMP 
    NAMECOLOR FUNCTION
    0
    0
    0
    0
    Front 1
    2
    3
    UP 
    						