    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    Application Processor Card
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 225
    PN-4RSTB (MFR) X X XPage 300
    PN-4RSTC (CIR) X XPage 302
    PN-SC00 (CCH) X XPage 304
    PN-SC01 (DCH) X XPage 307
    PN-SC03 (ICH) X XPage 310
    PN-SC03-A (CSH) X XPage 312
    PZ-M537
    (EXPMEM)–X–Page 314
    PZ-M542 (CONN)–XXPage 317
    PZ-M557 (CONN)–XXPage 319
    Table 3-2  List of Application Processor Cards (Continued)
    NAME
    (FUNCTIONAL
    NAME)LAMP
    X: PROVIDED
    –:NOT 
    PROVIDEDSWITCH
    X: PROVIDED
    –:NOT 
    PROVIDEDEXTRACTION/
    INSERTION WITH 
    POWER ON
    X: ALLOWED
    : ALLOWED 
    AFTER MB*
    –: NOT ALLOWEDREFERENCE
    PA G E
    *MB = Make Busy 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-AP00-A (DBM)
    NEAX2000 IVS2 Installation Procedure ManualPage 226ND-70928 (E), Issue 1.0
    PN-AP00-A (DBM)
    Locations of Lamps, Switches, and Connectors
    RS3
    RS2
    RS1
    RS0
    SENSE
    RUN
    MB
    SW0
    WE 
    L3 
    L2 
    L1 
    L0 SW1
    J16 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-AP00-A (DBM)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 227
    Lamp Indications
    Switch Settings
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    WE Red Not used
    L0-L3 Green Second data setting value for CMD001 > 250
    0 1 (Port 0)-3 (Port 2)
    L3 Indication of transmitting 
    status of Por t 0Indication of CTS signal status on 
    Po r t  0 - 2
    L2 Indication of transmitting 
    status of Por t 1Indication of DCD signal status on 
    Po r t  0 - 2
    L1 Indication of transmitting 
    status of Por t 2Indication of TXD signal status on 
    Po r t  0 - 2
    L0 Indication of transmitting 
    status of Por t 3Indication of RXD signal status on 
    Po r t  0 - 2
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 14-F Set the switch to match the AP Number (04-15) to
    be set by CM05.
    0-3 Not used
    MB (Toggle SW)
    NOTE 2UP For make-busy
    For normal operation
    (Continued)
    F
    4AP No.04 05 06 07 08 09 10 11 12 13 14 15
    SW No.456789ABCDEF
    ON
    DOWN 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-AP00-A (DBM)
    NEAX2000 IVS2 Installation Procedure ManualPage 228ND-70928 (E), Issue 1.0
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and   , the setting of the switch varies with the system concerned.
    NOTE 1:
    Set the groove on the switch to the desired position.
    NOTE 2:
    When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
    ging the circuit card. SW1
    (Piano Key SW)
    1For normal operation
    OFF Not used
    2For normal operation
    OFF Not used
    3For normal operation
    OFF Not used
    4 Not used
    SW0 (DIP SW)
    1 - 8 Not used
    J16 For normal operation
    (Memory backup ON)
    LEFTNot used
    (Memory backup OFF)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    4 
    3 
    2 
    1 OFF
    ON
    ON
    ON
    ON
    OFF
    1
    23
    45
    67
    8ONOFF
    Front (Jumper pin)
    RIGHT 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-AP00-B (AP00)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 229
    PN-AP00-B (AP00)
    Locations of Lamps, Switches, and Connectors
    CONN: To CONNR connector on PZ-M537 (EXPMEM)
    RS3
    RS2
    RS1
    RS0
    SENSE
    RUN
    MB
    SW0 SW2
    L3 
    L2 
    L1 
    L0 SW1 CONN
    JP0
    JP1 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-AP00-B (AP00)
    NEAX2000 IVS2 Installation Procedure ManualPage 230ND-70928 (E), Issue 1.0
    Lamp Indications
    Switch Settings
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    L0-L3 Green Second data setting value for CMD001 > 250
    0 1 (Por t 0)-3 (Por t 2)
    L3 Indication of transmitting 
    status of Por t 0Indication of CTS signal status on
    Po r t  0 - 2
    L2 Indication of transmitting 
    status of Por t 1Indication of DCD signal status on
    Po r t  0 - 2
    L1 Indication of transmitting 
    status of Por t 2Indication of TXD signal status on
    Po r t  0 - 2
    L0 Indication of transmitting 
    status of Por t 3Indication of RXD signal status on
    Po r t  0 - 2
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE 
    (Rotary SW)
    NOTE 10-3 Not used
    4-F Set the switch to match the AP Number (04-31) to
    be set by CM05.
    MB (Toggle SW)
    NOTE 2UP For make-busy
    For normal operation
    (Continued)
    F
    4
    AP No.SW1-4: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW1-4: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF
    ON
    DOWN 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-AP00-B (AP00)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 231
    SW0 (DIP SW)
    1-3ON Not used
    For normal operation
    4, 5For normal operation
    OFF Not used
    6
    NOTE 3ONSets No. 0 Port forcibly in a state 
    which DSR signal is always pro-
    vided.
    OFFReceives DSR signal from the DCE 
    on No. 0 Port.
    7
    NOTE 3ONSets No. 1 Port forcibly in a state 
    which DSR signal is always provided.
    OFFReceives DSR signal from the DCE 
    on No. 1 Port.
    8
    NOTE 3ONSets No. 2 Port forcibly in a state 
    which DSR signal is always provided.
    OFFReceives DSR signal from the DCE 
    on No. 2 Port.
    SW1
    (Piano Key SW)
    1For normal operation
    OFF Not used
    2For normal operation
    OFFFor AP data clearing by CMD100/
    CMD101
    3For normal operation
    OFFFor AP data clearing by CMD100/
    CMD101
    4ON AP No. 4-15
    OFF AP No. 20-31
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    1
    23
    45
    67
    8ONOFF
    ON
    4 
    3 
    2 
    1 OFF
    ON
    ON
    ON
    ON 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-AP00-B (AP00)
    NEAX2000 IVS2 Installation Procedure ManualPage 232ND-70928 (E), Issue 1.0
    SW2 (DIP SW)
    1
    NOTE 3ONSets No. 3 Port forcibly in a state 
    which DSR signal is always pro-
    vided.
    OFFReceives DSR signal from the DCE 
    on No. 3 Port.
    2ONEnables the receive clock from the 
    DCE (Modem) when No. 1 Port is 
    synchronous. (Clock is received at 
    the RXC terminal)
    OFFUses internal clock as the receive 
    clock when No. 1 Port is synchro-
    nous.
    When No. 1 Port is asynchronous.
    3ONEnables transmit clock from the 
    DCE (Modem) when No. 1 Port is 
    synchronous. (Clock is received at 
    the TXC (2) terminal.)
    OFFUses internal clock as the send 
    clock when No. 1 Port is synchro-
    nous.
    When No. 1 Port is asynchronous.
    4ONTransmit the send clock from the 
    DTE (this card) when No. 1 Port is 
    synchronous. (Clock is transmitted 
    from the TXC (1) terminal)
    OFFNot transmit the send clock from 
    the DTE (this card) when No. 1 
    Port is synchronous.
    When  No. 1 Port is asynchronous.
    5ON When No. 1 Port is asynchronous.
    OFF When No. 1 Port is synchronous.
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    1
    23
    45
    67
    8ON 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-AP00-B (AP00)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 233
    The figure in the SWITCH NAME column and the position in    in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and   , the setting of the switch varies with the system concerned.
    NOTE 1:
    Set the groove on the switch to the desired position.
    NOTE 2:
    When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
    ging the circuit card.
    NOTE 3:
    When the DCE connected to the port does not provide a function to send the DSR sig-
    nals, set the switch to ON. In this case, the AP00 card cannot recognize the actual state
    of the DCE, so that the call records or system messages will not be stored in the mem- SW2 (DIP SW)
    6
    NOTE 4ONUses internal clock as the receive 
    clock when No. 1 Port is synchro-
    nous.
    When No. 1 Port is asynchronous.
    OFFEnables receive clock from the DCE 
    (Modem) when No. 1 Port is syn-
    chronous. (Clock is received at the 
    RXC terminal)
    7Not used
    8Not used
    JP0 (Jumper SW) For normal operation
    (Memory backup ON)
    DOWNNot used
    (Memory backup OFF)
    JP1 (Jumper SW)
    UP Not used
    For normal operation
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    1
    23
    45
    67
    8ON
    OFF
    OFF
    UP
    DOWN 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-AP00-B (AP00)
    NEAX2000 IVS2 Installation Procedure ManualPage 234ND-70928 (E), Issue 1.0
    ory buffer on the AP00 card even if the cable is disconnected from the DCE.
    When the switch is set to OFF, the call records or system messages will be stored
    when the cable is disconnected, and will be sent when the cable is re-connected.
    NOTE 4:
    The use of the external clock (from the distant end) or the internal clock is determined
    by the following table:
    CLOCKSW2
    26
    External ON OFF
    Internal OFF ON 
    						
    All NEC manuals Comments (0)