    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-8DLCP (DLC)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 355
    PN-8DLCP (DLC)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0-7 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL7
    BL6
    BL5
    BL4
    BL3
    BL2
    BL1
    BL0 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2DPCB (DPC)
    NEAX2000 IVS2 Installation Procedure ManualPage 356ND-70928 (E), Issue 1.0
    PN-2DPCB (DPC)
    Location of Lamps, Switches, and Connectors
    SW0
    XCN1
    XCN0
    RS1
    RS0BL1
    LB11
    LB12 RSC1
    SDT1
    RDR1
    CDI1
    RSC0
    SDT0
    RDR0
    CDI0BL0
    LB01
    LB02
    SW1
    To X.21 DTE/DCE 
    or PN-M03
    To V.24/V.28 DTE/DCE 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2DPCB (DPC)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 357
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    BL0 Red No. 0 
    CircuitON:  Ready for digital data transmission or the cir-
    cuit is busy.
    OFF: Fixed path is not connected.
    Flash (60 IPM):  Make-busy state or the system 
    data for this card is not assigned.
    Flash (120 IPM): Fixed path is connected.
    LB01 Red ON:  Loop Back 1 is set.
    OFF: Normally operating.
    LB02 Red ON:  Loop Back 2 is set.
    OFF: Normally operating.
    RSC0 Green ON:  RTS/C signal ON
    OFF: RTS/C signal OFF
    SDT0 Green ON:  TXD/T signal is “0”.
    OFF: TXD/T signal is “1”.
    RDR0 Green ON:  RXD/R signal is “0”.
    OFF: RXD/R signal is “1”.
    CDI0 Green ON:  DCD/I signal ON
    OFF: DCD/I signal OFF
    (Continued) 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2DPCB (DPC)
    NEAX2000 IVS2 Installation Procedure ManualPage 358ND-70928 (E), Issue 1.0
    Switch SettingsBL1 Red No. 1
    CircuitON:  Ready for digital data transmission or the cir-
    cuit is busy.
    OFF: Fixed path is not connected.
    Flash (60 IPM):  Make-busy state or the system 
    data for this card is not assigned.
    Flash (120 IPM): Fixed path is connected.
    LB11 Red ON:  Loop Back 1 is set.
    OFF: Normally operating.
    LB12 Red ON:  Loop Back 2 is set.
    OFF: Normally operating.
    RSC1 Green ON:  RTS/C signal ON
    OFF: RTS/C signal OFF
    SDT1 Green ON:  TXD/T signal is “0”.
    OFF: TXD/T signal is “1”.
    RDR1 Green ON:  RXD/R signal is “0”.
    OFF: RXD/R signal is “1”.
    CDI1 Green ON:  DCD/I signal ON
    OFF: DCD/I signal OFF
    SWITCH NAMESWITCH 
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SW1
    (Piano Key SW)1ON No. 0 
    CircuitLoop Back 1 ON
    Loop Back 1 OFF
    2ON Loop Back 2 ON
    Loop Back 2 OFF
    3ON No. 1 
    CircuitLoop Back 1 ON
    Loop Back 1 OFF
    4ON Loop Back 2 ON
    Loop Back 2 OFF
    (Continued)
    LAMP 
    NAMECOLOR FUNCTION
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF
    OFF 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2DPCB (DPC)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 359
    The figure in the SWITCH NAME column and the position in in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and , the setting of the switch varies with the system concerned.
    NOTE:
    When the power is on, disconnect the cables before unplugging the circuit card and
    connect the cables after plugging the circuit card. SW0 (DIP SW)
    1ONNo. 0 
    CircuitForcibly turning the DTR 
    signal to ON
    OFFThe DTR signal from DTE 
    goes through the card
    2ONForcibly turning the RTS/C 
    signal to ON
    OFFThe RTS/C signal from 
    DTE goes through the 
    card
    3 Not used
    4ON V.11 (X.21) interface
    OFFV.24/V.28 (RS-232C) 
    interface
    5ONNo. 1 
    CircuitForcibly turning the DTR 
    signal to ON
    OFFThe DTR signal from DTE 
    goes through the card
    6ONForcibly turning the RTS/C 
    signal to ON
    OFFThe RTS/C signal from 
    DTE goes through the 
    card
    7 Not used
    8ON V.11 (X.21) interface
    OFFV.24/V.28 (RS-232C) 
    interface
    SWITCH NAMESWITCH 
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    1
    23
    45
    67
    8ON
    OFF
    OFF 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2ILCA (ILC)
    NEAX2000 IVS2 Installation Procedure ManualPage 360ND-70928 (E), Issue 1.0
    PN-2ILCA (ILC)
    Locations of Lamps, Switches, and Connectors
    PA L 1AC T1
    LPB1
    B21
    B11
    PA L 0 AC T0
    LPB0
    B20
    B10
    SW1
    SW0 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2ILCA (ILC)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 361
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    ACT1 Green No.1 
    CircuitON: Normally operating.
    OFF: Not operating.
    PAL1 Red ON:  Line is short-circuiting.
    OFF: Normally operating.
    LPB1 Red OFF: Not used.
    B21 Green ON: B2 channel is in use.
    OFF: B2 channel is idle.
    B11 Green ON: B1 channel is in use.
    OFF: B1 channel is idle.
    ACT0 Green No. 0 
    CircuitON: Normally operating.
    OFF: Not operating.
    PAL0 Red ON: Line is short-circuiting.
    OFF: Normally operating.
    LPB0 Red OFF: Not used
    B20 Green ON: B2 channel is in use.
    OFF: B2 channel is idle.
    B10 Green ON: B1 channel is in use.
    OFF: B1 channel is idle. 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2ILCA (ILC)
    NEAX2000 IVS2 Installation Procedure ManualPage 362ND-70928 (E), Issue 1.0
    Switch Settings
    The figure in the SWITCH NAME column and the position in in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and , the setting of the switch varies with the system concerned.
    SWITCH NAMESWITCH 
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    SW1
    (Piano Key SW)1 Always set to OFF
    2 Always set to OFF
    3 Always set to OFF
    4 Always set to OFF
    SW0
    (Piano Key SW)
    1No.0
    Circuit
    (Receiving)Terminating register is
    provided.
    OFFTerminating register is
    not provided.
    2No.0
    Circuit
    (Sending)Terminating register is
    provided.
    OFFTerminating register is
    not provided.
    3No.1
    Circuit
    (Receiving)Terminating register is
    provided.
    OFFTerminating register is
    not provided.
    4No.1
    Circuit
    (Sending)Terminating register is
    provided.
    OFFTerminating register is
    not provided.
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF
    OFF
    4 
    3 
    2 
    1 OFF
    ON
    ON
    ON
    ON
    ON 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-4LCC (LC)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 363
    PN-4LCC (LC)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0-3 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL3
    BL2
    BL1
    BL0 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-4LCD-A (LC)
    NEAX2000 IVS2 Installation Procedure ManualPage 364ND-70928 (E), Issue 1.0
    PN-4LCD-A (LC)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0-3 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL3
    BL2
    BL1
    BL0 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Installation Procedure Manual