NEC Neax 2000 Ivs2 Installation Procedure Manual
Have a look at the manual NEC Neax 2000 Ivs2 Installation Procedure Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CHAPTER 2 INSTALLATION MDF Cross Connections NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 125 Table 2-5 LTC0 - LTC3 MDF Cross Connection Information PINRUNNING CABLESTATION CABLESLOTSTYPE OF INTERFACE 2 wire D term/ SMARTCON/ DSSCON/ DESKCON4 wire SMARTCON (SN610 ATTCON)EXT. KEY/ EXT. RELAYEXT. PA G E / MOH/ BGMDigital TRK NOTE 3 8DLC 4DLC 2DLC 2DLCC DK00 4COT DTI 26 WH-BL GN 1T0 T0 T0 RA0 K1 T RA 1 BL-WH RD R0 R0 R0 TA0 K0 R RB 27WH-ORBK T1T1T1 RB0 K3T TA 2 OR-WH YL R1 R1 R1 TB0 K2 R TB 28 WH-GN GN T2 T2 RA1 K5 T 3 GN-WH RD R2 R2 TA1 K4 R 29 WH-BR BK T3 T3 RB1 K7 T 4 BR-WH YL R3 R3 TB1 K6 R 30 WH-SL GN T4 5 SL-WH RD R4 31 RD-BL BK T5 6 BL-RD YL R5 32 RD-OR GN T6 7 OR-RD RD R6 33 RD-GN BK T7 8 GN-RD YL R7 NOTE 1
CHAPTER 2 INSTALLATION MDF Cross Connections NEAX2000 IVS2 Installation Procedure ManualPage 126ND-70928 (E), Issue 1.0 34 RD-BR GN 2T0 T0 T0 RA0 K1 T RA 9 BR-RD RD R0 R0 R0 TA0 K0 R RB 35RD-SL BK T1T1T1 RB0 K3T TA 10 SL-RD YL R1 R1 R1 TB0 K2 R TB 36 BK-BL GN T2 T2 RA1 K5 T 11 BL-BK RD R2 R2 TA1 K4 R 37 BK-OR BK T3 T3 RB1 K7 T 12 OR-BK YL R3 R3 TB1 K6 R 38 BK-GN GN T4 13 GN-BK RD R4 39 BK-BR BK T5 14 BR-BK YL R5 40 BK-SL GN T6 15 SL-BK RD R6 41 YL-BL BK T7 16 BL-YL YL R7 Table 2-5 LTC0 - LTC3 MDF Cross Connection Information (Continued) PINRUNNING CABLESTATION CABLESLOTSTYPE OF INTERFACE 2 wire D term/ SMARTCON/ DSSCON/ DESKCON4 wire SMARTCON (SN610 ATTCON)EXT. KEY/ EXT. RELAYEXT. PA G E / MOH/ BGMDigital TRK NOTE 3 8DLC 4DLC 2DLC 2DLCC DK00 4COT DTI NOTE 1
CHAPTER 2 INSTALLATION MDF Cross Connections NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 127 42 YL-OR GN 3T0 T0 T0 RA0 K1 T RA 17 OR-YL RD R0 R0 R0 TA0 K0 R RB 43YL-GNBK T1T1T1 RB0 K3T TA 18 GN-YL YL R1 R1 R1 TB0 K2 R TB 44 YL-BR GN T2 T2 RA1 K5 T 19 BR-YL RD R2 R2 TA1 K4 R 45 YL-SL BK T3 T3 RB1 K7 T 20 SL-YL YL R3 R3 TB1 K6 R 46 VI-BL GN T4 21 BL-VI RD R4 47 VI-OR BK T5 22 OR-VI YL R5 48 VI-GN GN T6 23 GN-VI RD R6 49 VI-BR BK T7 24 BR-VI YL R7 50 VI-SL MN * 25 SL-VI MJ* * PIN No.50, 25 in PIM0 are connected to external indication equipment for major card minor alarm. NOTE 1: PIN No. 46, 21 to 49, 24 on LTC3 cannot be used. NOTE 2: PIN No. 46, 21 to 49, 24 on LTC2 and LTC3 cannot be used. NOTE 3: For the Digital Trunk Interface card, use the different LTC connector from the analog line/trunk card. The digital line should be separated from the analog line. Table 2-5 LTC0 - LTC3 MDF Cross Connection Information (Continued) PINRUNNING CABLESTATION CABLESLOTSTYPE OF INTERFACE 2 wire D term/ SMARTCON/ DSSCON/ DESKCON4 wire SMARTCON (SN610 ATTCON)EXT. KEY/ EXT. RELAYEXT. PA G E / MOH/ BGMDigital TRK NOTE 3 8DLC 4DLC 2DLC 2DLCC DK00 4COT DTI NOTE 2
CHAPTER 2 INSTALLATION Installation of Peripheral Equipment NEAX2000 IVS2 Installation Procedure ManualPage 128ND-70928 (E), Issue 1.0 INSTALLATION OF PERIPHERAL EQUIPMENT Table 2-6 Peripheral Equipment and Card List PERIPHERAL EQUIPMENT CIRCUIT CARDREFERENCE Pag e Analog C.O. Trunk PN-2COT/PN-4COT/PN-6COT/PN-8COTPage 129 Tie Line Trunk PN-2LDT PN-2ODTPage 130 DID Trunk PN-AUC PN-4DITPage 135 Digital Trunk Interface PN-24DTA/PN-30DTC PZ-M542/PZ-M557 [For Others/Australia]Page 137 Single Line Telephone PN-4LC/PN-8LC PN-AUCPage 144 D term/DSS Console PN-2DLC PN-4DLC/PN-8DLCPage 146 SN716 DESKCON PN-4DLC/PN-8DLCPage 148 SN610/708/709/712 ATTCON PN-2DLC/PN-4DLC/PN-8DLCPage 158 Day/Night Mode Change by External KeyPN-DK00/PN-CP14Page 168 External TAS Indicator PN-DK00/PN-CP14Page 169 Paging Equipment PN-2COT/PN-4COT/PN-6COT/PN-8COT PN-DK00/PN-CP14Page 172 External Tone Source/Announcement MachinePN-2COT/PN-4COT/PN-6COT/PN-8COT PN-TNTA PN-DK00/PN-CP14Page 175 External BGM Source PN-2COT/PN-4COT/PN-6COT/PN-8COT PN-TNTA PN-DK00/PN-CP14Page 180 Power Failure Transfer PN-2COT/PN-4COT/PN-6COT/PN-8COT PN-AUCPage 182 Power Failure Transfer PN-8PFTB PN-8LC PN-8COTPage 185 Alarm Display Panel PN-CP14Page 190 Built-in SMDR PN-CP14Page 191 SMDR/PMS/MCI/CIS Printer/ Hotel PrinterPN-AP00-BPage 194
CHAPTER 2 INSTALLATION Analog C.O. Trunk (COT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 129 Analog C.O. Trunk (COT) Figure 2-47 MDF Cross Connection for C.O. Trunk Card 33T7338 R7832 T6327 R6727 T12726 T026 2 1 26 T0 1 R0 27 T1 2 R1 32 T6 7 R6 33 T7 8 R7 LT C 0 ( P ) 1R026T0 2R127T1 7R632T6 8R733T7LEN000 LEN001 LEN006 LEN007 LT C 0 ( J )MDF R01 R12 LEN000 (No. 0) PIM0 P PN-8COT LT 0 0LT C 0 J LEN001 (No. 1) LEN006 (No. 6) LEN007 (No. 7) TO C.O. LINE
CHAPTER 2 INSTALLATION Tie Line Trunk (LDT/ODT) NEAX2000 IVS2 Installation Procedure ManualPage 130ND-70928 (E), Issue 1.0 Tie Line Trunk (LDT/ODT) LD Trunk (PN-2LDT) Figure 2-48 MDF Cross Connection for LD Trunk Card 272726 26 2 1 MDF 1 2 PIM0 P PN-2LDT LT 0 0LT C 0 J T0 R0 T1 R1 TO T IE L I N E TO T IE L I N ELEN001 (No. 1) LEN000 (No. 0) LEN000 LEN0011R026T0 2R127T1 328 429 LT C 0 ( P )LT C 0 ( J ) 26 T0 1 R0 27 T1 2 R1 28 3 29 4
CHAPTER 2 INSTALLATION Tie Line Trunk (LDT/ODT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 131 4W E&M Trunk (PN-2ODT) When connecting the E and M, make the installation cable by using the connector attached with the PN-2ODT card. NOTE: Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN- 2ODT card. Figure 2-49 MDF Cross Connection for 4W E&M Trunk Card (1 of 2) 1 26 2 27 3 28 4 29TxR0 TxT0 RcvR0 RcvT0 TxR1 TxT1 RcvR1 RcvT1MDF LEN001 (No. 1) LEN000 (No. 0)PIM0 PN-2ODT LT 0 0 LEN001 (No. 1) 1 26 2 27 3 28 4 29 (Rcv Tip) (Rcv Ring) (M) TO TI E L IN E JPLT C 0 LEN000 (No. 0) 08 07 06 05 04 M1 03 E1 02 M0 01 E0(E) (Tx Tip) (Tx Ring) JCN1 INSTALLATION CABLE 2 1
CHAPTER 2 INSTALLATION Tie Line Trunk (LDT/ODT) NEAX2000 IVS2 Installation Procedure ManualPage 132ND-70928 (E), Issue 1.0 Figure 2-49 MDF Cross Connection for 4W E&M Trunk Card (2 of 2) LTC CONNECTORCN1 CONNECTOR (FRONT CONNECTOR) LEN000 LEN0011 TxR0 26 TxT0 2 RcvR0 27 RcvT0 3 TxR1 28 TxT1 4 RcvR1 29 RcvT1 LT C 0 ( P ) 26 TxT0 1 TxR0 27 RcvT0 2 RcvR0 28 TxT1 3 TxR1 29 RcvT1 4 RcvR1 LT C 0 ( J ) 12 M1 E1 M0 E0LEN001 LEN000 CN1
CHAPTER 2 INSTALLATION Tie Line Trunk (LDT/ODT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 133 2W E&M Trunk (PN-2ODT) When connecting the E and M, make the installation cable by using the connector attached with the PN-2ODT card. NOTE: Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN- 2ODT card. Figure 2-50 MDF Cross Connection for 2W E&M Trunk Card (1 of 2) 1 26 3 28R0 T0 R2 T2MDF LEN001 (No. 1) LEN000 (No. 0)PIM0 PN-2ODT LT 0 0 LEN001 (No. 1) 1 26 3 28 (M) TO TIE LINE JPLT C 0 LEN000 (No. 0) CN1 08 07 06 05 04 M1 03 E1 02 M0 01 E0(E) (Ring) (Tip) J INSTALLATION CABLE 2 1
CHAPTER 2 INSTALLATION Tie Line Trunk (LDT/ODT) NEAX2000 IVS2 Installation Procedure ManualPage 134ND-70928 (E), Issue 1.0 Figure 2-50 MDF Cross Connection for 2W E&M Trunk Card (2 of 2) LTC CONNECTORCN1 CONNECTOR (FRONT CONNECTOR) LEN000 LEN0011R026T0 227 3R228T2 429 LT C 0 ( P ) 26 T0 1 R0 27 2 28 T2 3 R2 29 4 LT C 0 ( J ) M1 E1 M0 E0LEN001 LEN000 CN1 1 2