    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-AUCA (AUC)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 325
    PN-AUCA (AUC)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0, 1 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL1
    BL0
    CN1 TO COT CARD 
    FOR PFT CONNECTION 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-CFTA (CFT)
    NEAX2000 IVS2 Installation Procedure ManualPage 326ND-70928 (E), Issue 1.0
    PN-CFTA (CFT)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL RedRemains lit when this card is in use.
    Flashes (60 IPM) when the circuit on the card is in make-busy 
    state on the system data for this card is not assigned.
    BL 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-CFTB (CFT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 327
    PN-CFTB (CFT)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL RedRemains lit when this card is in use.
    Flashes (60 IPM) when the circuit on the card is in make-busy 
    state on the system data for this card is not assigned.
    BL 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2COTD (COT)
    NEAX2000 IVS2 Installation Procedure ManualPage 328ND-70928 (E), Issue 1.0
    PN-2COTD (COT)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0, 1 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in  make-
    busy state or the system data for this card is not assigned.
    LF0, 1 RedRemains lit when the corresponding circuit detects a meter sig-
    nal or a line fault condition.
    BL1
    BL0
    LF1
    LF0
    CN0 TO PN-AUCA CARD 
    FOR PFT CONNECTION 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-4COTA-A (COT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 329
    PN-4COTA-A (COT)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0-3 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL3
    BL2
    BL1
    BL0
    CN1
    TO PN-AUCA CARD 
    FOR PFT CONNECTION 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-4COTB (COT)
    NEAX2000 IVS2 Installation Procedure ManualPage 330ND-70928 (E), Issue 1.0
    PN-4COTB (COT)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0-3 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL3
    BL2
    BL1
    BL0
    CN1
    TO PN-AUCA CARD 
    FOR PFT CONNECTION 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-4COTE (COT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 331
    PN-4COTE (COT)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0-3 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    LF0-3 RedRemains lit when the corresponding circuit detects a line fault 
    condition.
    BL3
    BL2
    BL1
    BL0
    LF3
    LF2
    LF1
    LF0
    CN1
    TO PN-AUCA CARD 
    FOR PFT CONNECTION 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-4COTF (COT)
    NEAX2000 IVS2 Installation Procedure ManualPage 332ND-70928 (E), Issue 1.0
    PN-4COTF (COT)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0-3 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL3
    BL2
    BL1
    BL0
    CN1
    TO PN-AUCA CARD 
    FOR PFT CONNECTION 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-4COTG (COT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 333
    PN-4COTG (COT)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0-3 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    BL3
    BL2
    BL1
    BL0
    CN1
    TO PN-AUCA CARD 
    FOR PFT CONNECTION 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-6COTJ (COT)
    NEAX2000 IVS2 Installation Procedure ManualPage 334ND-70928 (E), Issue 1.0
    PN-6COTJ (COT)
    Locations of Lamps, Switches, and Connectors
    Lamp Indications
    Switch Settings
    This card has no switches.
    LAMP 
    NAMECOLOR FUNCTION
    BL0-5 RedRemains lit when the corresponding circuit is in use.
    Flashes at 60 IPM when the corresponding circuit is in make-
    busy state or the system data for this card is not assigned.
    LF0-5 RedRemains lit when the corresponding circuit detects a line fault
    condition.
    LF5
    LF4
    LF3
    LF2
    LF1
    LF0
    BL5
    BL4
    BL3
    BL2
    BL1
    BL0 
    						