    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2BRTC (BRT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 245
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 14-F Set the switch to match the AP Number (04-31) to
    be set by CM05.
    0-3 Not used
    MB (Toggle SW)
    NOTE 2UP For make-busy
    For normal operation
    SW0, SW10
    (DIP SW)
    1For terminating the transmitting side 
    of channels B1 and B2 with 100 
    ohms.
    OFFTo remove the terminating resistor 
    on the transmitting side of channels 
    B1 and B2.
    2For terminating the receiving side of 
    channels B1 and B2 with 100 ohms.
    OFFTo remove the terminating resistor 
    on the receiving side of channels B1 
    and B2.
    (Continued)
    F
    4AP No.SW11-4: ON
    04 05 06 07 08 09 10 11 12 13 14 15
    SW11-4: OFF
    20 21 22 23 24 25 26 27 28 29 30 31
    SW No.
    456789ABCDEF
    ON
    DOWN
    1
    2ON
    ON
    ON 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2BRTC (BRT)
    NEAX2000 IVS2 Installation Procedure ManualPage 246ND-70928 (E), Issue 1.0
    The figure in the SWITCH NAME column and the position in   in the SETTING POSITION
    column indicate the standard setting of the switch. When the switch is not set as shown by the
    figure and  , the setting of the switch varies with the system concerned.
    NOTE 1:
    Set the groove on the switch to the desired position.
    NOTE 2:
    When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
    ging the circuit card. SW11 (DIP SW)
    1For normal operation
    OFF Not used
    2
    NOTE 3
    NOTE 4ONOutput clock signals according to
    the switch setting of SW11-3.
    OFF Do not output clock signals.
    3
    NOTE 3
    NOTE 4ON Output clock signals to PLO 0 of MP.
    OFF Output clock signals to PLO 1 of MP.
    4ON AP No. 04-15
    OFF AP No. 20-31
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    1
    23
    4ON
    ON 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-2BRTC (BRT)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 247
    NOTE 3:
    The system can supply clock signals from two clock supply routes.
    In normal condition, the system synchronizes to the clock signals supplied on the PLO
    0 of MP card via the Back Wiring Board, and if the clock signals are failed, the clock
    supply route takes over to PLO1 automatically. Set SW11-2 and SW11-3 as follows.
    NOTE 4:
    When the system is a clock source office, set the SW11-2 and SW11-3 on all the BRT
    cards mounted in PIM0 to “OFF”.
    NOTE 5:
    Mount the BRT card which receives a source clock signals into PIM0. CONDITIONSBRT0 BRT1 BRT2 ---- BRT11
    REMARKS
    SW
    11-2SW
    11-3SW
    11-2SW
    11-3SW
    11-2SW
    11-3----SW
    11-2SW
    11-3
    When one BRT 
    is provided.ON ONMP card will receive the clock 
    signal from No.0 circuit of 
    BRT0 at its PLO0 input.
    Should a clock failure occure 
    with No.0 circuit, MP card will 
    switch to No. 1 circuit of 
    BRT0.
    When more 
    than one BRT 
    is provided.ON ON ON OFF OFF ON ---- OFF ONMP card will receive the clock 
    signal from BRT0 at its PLO0 
    input, under normal condi-
    tions.
    Should a clock failure occure 
    with both No.0 and No.1 cir-
    cuits of BRT0, MP card will 
    switch to the PLO1 input 
    which gets clock from BRT1. 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-CC01 (ETHER)
    NEAX2000 IVS2 Installation Procedure ManualPage 248ND-70928 (E), Issue 1.0
    PN-CC01 (ETHER)
    Location of Lamps, Switches, and Connectors
    RUN
    MB
    LINK 
    XMT 
    RCV 
    RV P  
    ERR
    IP 10BASE-T
    SW1SW2 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-CC01 (ETHER)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 249
    Lamp Indications
    Switch Settings
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 60 IPM while this card is operating normally.
    LINK Green Remains lit when link is established.
    XMT Green Remains lit when it is transmitting the data.
    RCV Green Remains lit when it is receiving the data.
    RVP Green Remains lit only when it is receiving the data with its own IP
    address.
    ERR–Not used
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    MB (Toggle SW)
    NOTE 1UP For make-busy
    For normal operation
    (Continued)
    ON
    DOWN 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-CC01 (ETHER)
    NEAX2000 IVS2 Installation Procedure ManualPage 250ND-70928 (E), Issue 1.0
    SW1 (DIP SW)
    NOTE 2
    SW1-5 (D11)
    SW1-6 (D10)
    SW1-7 (D9)
    SW1-8 (D8)
    1 (D15) ON
    2 (D14) ON
    3 (D13) ON
    4 (D12) OFF
    5 (D11)ON
    OFF
    6 (D10)ON
    OFF
    7 (D9)ON
    OFF
    8 (D8)ON
    OFF
    SW2 (DIP SW)
    NOTE 21 (D7)ON
    OFF
    2 (D6)ON
    OFF
    3 (D5)ON
    OFF
    4 (D4)ON
    OFF
    5 (D3)ON
    OFF
    6 (D2)ON
    OFF
    7 (D1)ON
    OFF
    8 (D0)ON
    OFF
    SWITCH
    NAMESWITCH
    NUMBERSETTING
    POSITIONFUNCTION CHECK
    1
    23
    45
    67
    8ON
    MAC ADDRESS SWITCH SETTING
    00004CA4 X X X X 
    (HEX)
        FixedSW2-5 (D3)
    SW2-6 (D2)
    SW2-7 (D1)
    SW2-8 (D0)ON/OFF
    ON/OFF
    ON/OFF
    ON/OFF
    SW2-1 (D7)
    SW2-2 (D6)
    SW2-3 (D5)
    SW2-4 (D4)ON/OFF
    ON/OFF
    ON/OFF
    ON/OFF
    SW1-5 (D11)
    SW1-6 (D10)
    SW1-7 (D9)
    SW1-8 (D8)ON/OFF
    ON/OFF
    ON/OFF
    ON/OFF
    SW1-1 (D15)
    SW1-2 (D14)
    SW1-3 (D13)
    SW1-4 (D12)ON/OFF
    ON/OFF
    ON/OFF
    ON/OFF
    ON:0  OFF:1
    1
    23
    45
    67
    8ON 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-CC01 (ETHER)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 251
    NOTE 1:
    When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
    ging the circuit card.
    NOTE 2:
    Each equipment must have a unique MAC address to distinguish between systems.
    Therefore, when more than one PBX is installed in the same network, assign the lower
    4 digits of the following MAC address by SW1 and SW2 to prevent duplicate address-
    es. 
    00004CA4 XX XX (HEX)
    According to the switch setting of SW2 (D7-D0)
    According to the switch setting of SW1 (D15-D8)
    Fixed 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-DAIA (DAI)
    NEAX2000 IVS2 Installation Procedure ManualPage 252ND-70928 (E), Issue 1.0
    PN-DAIA (DAI)
    Location of Lamps, Switches, and Connectors
    Lamp Indications
    LAMP 
    NAMECOLOR FUNCTION
    RUN Green Flashes at 120 IPM while this card is operating normally.
    LINK Green Remains lit when a link between this card and a distant office is 
    normally connected.
    Goes out after 15 seconds of link disconnection.
    RED Red Remains lit when detecting PCM signal loss or Frame Alignment 
    signal loss.
    RMT Red Remains lit when receiving the alarm signal from a distant office.
    LOOP–Not used
    PWR–Not used
    BL Red Remains lit while data transmission on control channel (D ch).
    Flashes while FP data downloading. 
    JPS
    JPR
    SW2
    SW3BUS
    PCM1
    PCM0
    CNSENSE
    RUN
    MB
    SW1LINK 
    RED 
    RMT 
    LOOP 
    PWR 
    BL 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-DAIA (DAI)
    NEAX2000 IVS2 Installation Procedure Manual
    ND-70928 (E), Issue 1.0Page 253
    Switch Settings
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    SENSE
    (Rotary SW)
    NOTE 10-FFP (Firmware Processor) Number setting for the
    DAIA card.
    By this setting, the system regards the DAIA card
    and the opposite DAIB card as one Firmware Pro-
    cessor.
    0 Not used
    1FP No. 1
    2FP No. 2
    3FP No. 3
    4 – F Not used
    MB (Toggle SW)
    NOTE 2UP For make-busy
    For normal operation
    SW1
    (Piano Key SW)1
    NOTE 3ONFor supplying 1.5MHz clock to 
    PLO 0
    No clock supply to PLO 0
    2
    NOTE 3ONFor supplying 1.5MHz clock to 
    PLO 1
    No clock supply to PLO 1
    3 Always set to OFF
    4 Always set to OFF
    (Continued)
    1
    32
    ON
    DOWN
    4 
    3 
    2 
    1 OFF
    ON
    OFF
    OFF
    OFF
    OFF 
    						
    							CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
    PN-DAIA (DAI)
    NEAX2000 IVS2 Installation Procedure ManualPage 254ND-70928 (E), Issue 1.0
    SW2 (DIP SW)
    1ONControl channel signaling data 
    transmission speed: 48kbps
    Control channel signaling data 
    transmission speed: 64kbps
    2ONDTI frame configuration: 12-Multi 
    Fram e
    DTI frame configuration: 24-Multi 
    Fram e
    3ON Line code: AMI with ZCS
    Line code: B8ZS
    4ONSetting of control signal time slot
    NOTE 4, NOTE 5 5ON
    6ON
    7
    OFF
    8ON
    (Continued)
    SWITCH NAMESWITCH 
    NUMBERSETTING 
    POSITIONFUNCTION CHECK
    1
    23
    45
    67
    8ONOFF
    OFF
    OFF
    SWITCH NUMBER
    TIME SLOT
    NUMBER
    45678
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    ON
    OFF
    OFFON
    OFF
    OFF
    ON
    ON
    OFF
    OFF
    ON
    ON
    OFF
    OFF
    ON
    ON
    OFF
    OFF
    ON
    ON
    OFF
    OFF
    OFFON
    ON
    ON
    OFF
    OFF
    OFF
    OFF
    ON
    ON
    ON
    ON
    OFF
    OFF
    OFF
    OFF
    ON
    ON
    ON
    ON
    OFFON
    ON
    ON
    ON
    ON
    ON
    ON
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    OFF
    ON
    ON
    ON
    ON
    ONON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    ON
    OFF
    OFF
    OFF
    OFF
    OFFTS1
    TS2
    TS3
    TS4
    TS5
    TS6
    TS7
    TS8
    TS9
    TS10
    TS11
    TS12
    TS13
    TS14
    TS15
    TS16
    TS17
    TS18
    TS19
    TS23
    OFF
    OFF
    OFF
    ON
    OFF 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2000 Ivs2 Installation Procedure Manual