CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-AP01 (AP01) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 235 PN-AP01 (AP01) Locations of Lamps, Switches, and Connectors Lamp Indications LAMP NAME COLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. L0-L3 L3 Green Indication of CTS signal status on RS-232C port. L2 Indication of DCD signal status on RS-232C port. L1 Indication of TXD signal status on RS-232C port. L0 Indication of RXD signal status on RS-232C port. RS0 SENSE RUN MB SW1 L3 L2 L1 L0 SW0 IP J19
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-AP01 (AP01) NEAX2000 IVS2 Installation Procedure ManualPage 236ND-70928 (E), Issue 1.0 Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-15) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2UP For make-busy For normal operation SW1 (Piano Key SW) 1For normal operation OFF Not used 2For normal operation OFF Not used 3For normal operation OFF Not used 4For normal operation OFF Not used (Continued) F 4AP No.04 05 06 07 08 09 10 11 12 13 14 15 SW No.456789ABCDEF ON DOWN 4 3 2 1 OFF ON ON ON ON ON
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-AP01 (AP01) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 237 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. SW0 (DIP SW) 1ON Receives RT clock Uses internal clock 2ON Receives ST2 clock Uses internal clock 3ON Sends ST1 clock Not send ST1 clock 4 Not used J19 For normal operation (Memory backup ON) LEFTNot used (Memory backup OFF) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1 23 4ONOFF OFF OFF OFF Front (Jumper pin) RIGHT
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-BRTA (BRT) NEAX2000 IVS2 Installation Procedure ManualPage 238ND-70928 (E), Issue 1.0 PN-BRTA (BRT) Locations of Lamps, Switches, and Connectors SENSE RUN MB SW1 SW0B1 B2 D ALM
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-BRTA (BRT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 239 Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. B1 Green B1 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy B2 Green B2 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy D Green D channel status ON: Busy OFF: Idle ALM Red Transmission line fault status ON: Line fault OFF: Normal operation
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-BRTA (BRT) NEAX2000 IVS2 Installation Procedure ManualPage 240ND-70928 (E), Issue 1.0 Switch Settings SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK SENSE (Rotary SW) NOTE 14-F Set the switch to match the AP Number (04-15) to be set by CM05. 0-3 Not used MB (Toggle SW) NOTE 2UP For make-busy For normal operation SW0 (DIP SW) 1For normal operation OFF Not used 2 NOTE 3 NOTE 4ONSource clock signal from network is sent to the PLO of MP according to the switch setting of SW0-3. OFFSource clock signal from network is not sent to the PLO of MP card. 3 NOTE 3 NOTE 4ONClock signal is sent to the PLO 0 of MP. OFFClock signal is sent to the PLO 1 of MP. 4For normal operation OFF Not used (Continued) AP No.04 05 06 07 08 09 10 11 12 13 14 15 SW No.456789ABCDEF ON DOWN 1 23 4ON ON ON
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-BRTA (BRT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 241 The figure in the SWITCH NAME column and the position in in the SETTING POSITION column indicate the standard setting of the switch. When the switch is not set as shown by the figure and , the setting of the switch varies with the system concerned. NOTE 1: Set the groove on the switch to the desired position. NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug- ging the circuit card. SW1 (DIP SW) 1For terminating the transmitting side of channels B1 and B2 with 100 ohms. OFFTo remove the terminating resistor on the transmitting side of channels B1 and B2. 2For terminating the receiving side of channels B1 and B2 with 100 ohms. OFFTo remove the terminating resistor on the receiving side of channels B1 and B2. (Continued) SWITCH NAMESWITCH NUMBERSETTING POSITIONFUNCTION CHECK 1 2ONON ON
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-BRTA (BRT) NEAX2000 IVS2 Installation Procedure ManualPage 242ND-70928 (E), Issue 1.0 NOTE 3: Set the SW0-2 and SW0-3 as follows: NOTE 4: When the system is a clock source office, set the SW0-2 and SW0-3 on all the BRT cards mounted in PIM0 to “OFF”. NOTE 5: Mount the BRT card which receives a source clock signals into PIM0. CONDITIONSBRT0 BRT1 BRT2 ---- BRT11 REMARKS SW 0-2SW 0-3SW 0-2SW 0-3SW 0-2SW 0-3----SW 0-2SW 0-3 When one BRT is provided.ON ONMP card will receive the clock signal from BRT0 at its PLO0 input. When more than one BRT is provided.ON ON ON OFF OFF ON ---- OFF ONMP card will receive the clock signal from BRT0 at its PLO0 input, under nor- mal conditions. Should a clock failure occur with BRT0, MP card will switch to the PLO1 input which gets clock from BRT1.
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-2BRTC (BRT) NEAX2000 IVS2 Installation Procedure Manual ND-70928 (E), Issue 1.0Page 243 PN-2BRTC (BRT) Locations of Lamps, Switches, and Connectors SENSE RUN MB B21 B11 D1 ALM1 B20 B10 D0 ALM0 SW0 SW11 SW10
CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS PN-2BRTC (BRT) NEAX2000 IVS2 Installation Procedure ManualPage 244ND-70928 (E), Issue 1.0 Lamp Indications LAMP NAMECOLOR FUNCTION RUN Green Flashes at 120 IPM while this card is operating normally. B21 Red No.1 Circuit B2 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy B11 Red B1 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy D1 Green D channel status ON: Busy OFF: Idle ALM1 Red Transmission line fault status ON: Line fault OFF: Normal operation B20 Red No.0 Circuit B2 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy B10 Red B1 channel status ON: Busy OFF: Idle Flash (60 IPM): Make Busy D0 Green D channel status ON: Busy OFF: Idle ALM0 Red Transmission line fault status ON: Line fault OFF: Normal operation