    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-9 Access the System 
    3
    .
    Setting the Data Module Operating Mode
    1. Connec t an RS-232 c ab le from the DSA/DNA c omp uter to the d ata 
    mod ule. If you are using  an 8400B+ , c onnec t the DSA/DNA c omp uter to 
    the data module using the supplied adapter cable.
    2. Using  a terminal emulator, c onnec t to the serial p ort to whic h the d ata 
    mod ule is c onnec ted , and  set the emulation to 
    vt100 mod e.
    3. Type AT
     at the p romp t and  p ress 
    En t e r.The d ata mod ule should  return an 
    OK. If it d oes not, b e sure that a stand ard RS-232 or EIA-232 c ab le is 
    connec ted (not a null modem c able).
    4. Set the operating mode as described in the following table.
    5. Disc onnec t the terminal from the d ata mod ule and  rec onnec t the d ata 
    mod ule to the system c ab ling . Ty p e  o f  
    Data Module How to Test and Troubleshoot
    8400B+ The red  LED should b e stead y on. If the red  and  g reen LEDs 
    are b linking , the unit is not c ommunic ating  with the DEFINITY 
    ECS. Chec k the wiring  at the MDF, wall jac k, and  the 8400B+ . 
    7400B+ The Power and  TR LEDs should  b e stead y on. If the Power 
    and  Data LEDs are b linking , the unit is not c ommunic ating  with 
    the DEFINITY ECS. Chec k the wiring  at the MDF, wall jac k, 
    and  the 7400B+ . 
    7400A Set the 7400A to DCE mod e. The Power LED must b e stead y 
    on. The DTR, DSR, DCD, RTS, and  CTS setting s must b e 
    hig hlig hted in the d isp lay. If the Power LED is b linking , the 
    d ata mod ule is not c ommunic ating  with the DEFINITY ECS. 
    Chec k the wiring  at the MDF, wall jac k, and  7400A.
    Ty p e  o f  
    Data Module How to set the operating mode
    8400B+ Typ e AT&F
     and press 
    En t e r. Typ e ATS24=1
     and press 
    En te r. Type AT&WØ
     and press En t e r to save the operating 
    mode into non-volatile RAM.
    7400A
    7400B+Ty p e  AT&F
     and press 
    En t e r. Typ e AT&WØ
     and press 
    En te r to save the op erating  mod e into non-volatile RAM. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-10 Access the System 
    3
    Setting the 7400B+ Options
    1. Set the DIP switc hes for the 7400B+  using  Tab le 3-3. The DIP switc hes are 
    loc ated  insid e the unit. To ac c ess them
    a. Remove the p ower c ord  from the unit.
    b . Remove the c over from the top  rear of the unit.
    c . Set the d ip  switc hes.
    d . Rep lac e the c over.
    e. Connect the power c ord.The unit performs a self test.
    2. If any switc hes were set in step  1, c yc le the p ower to the d ata mod ule so 
    that the firmware c an read  the new switc h setting s.
    Table 3-3. DIP Switch Settings (7400B+)
    Option DIP Switch Setting
    No Telep hone Connec ted 1 On
    Data Metering 5 Off
    Sup p ress Touc h-tone/Dial Tone 6 Off
    Sp eakerp hone Disab le/Enab le 7 Off
    Busyout on Loc al Loop 8 Off
    Unused  DIP Switc hes 2, 3, and  4 Off 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-11 Access the System 
    3
    Connecting by analog modem to INADS port
    You c an c onnec t a PC to the DEFINITY ECS throug h a mod em.
    1. Connec t the eq uip ment as shown in Fi g u re  3 - 5
    .
    Figure 3-5. A typical remote connection through a modem to access a remote 
    DEFINITY ECS
    Follow these step s to c onnec t to the DEFINITY ECS through a mod em.
    1. Connec t the c omp uter to the mod em.
    2. Connec t an analog  telephone line to the left most analog -line p ort on the 
    mod em. 
    3.Make sure that the mod em’s DIP switc hes are set as shown in Ta b l e  3 - 4
    . Figure Notes
    1. Comp uter with DSA or DNA
    2. 50-ft (15-m) M25A c ab le (RS-232—
    9-25 p in ad ap ter if need ed )
    3. Analog  mod em
    4. 7-ft (2-m) D2W mod ular c ord
    5. 103A or Luc ent mod ular wall jac k
    6. Main d istrib ution frame (MDF)7. Analog line circuit pack
    8. Analog  trunk c irc uit p ac k
    Pac ket d ata line (R8r)
    Data line (R8r)
    9. DEFINITY ECS
    10. B25A c ab le
    11. Analog  line
    cydr0031 LJK 021800
    1
    2
    3
    11
    4
    5
    78
    9
    1010
    6 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-12 Access the System 
    3
    4. Plug  the mod em into an AC p ower outlet.
    5. Turn on the modem.
    6. Set the following  p ort setting s:
    Table 3-4. U.S. Robotics Modem Dip Switch Settings
    Dip 
    Switch Setting Description
    1UP
    DOWNData Terminal Ready normal
    Data Terminal Ready override
    2UP
    DOWNVe r b a l  re su lt  c o d e s
    Numeric result codes
    3UP
    DOWNSuppress result codes
    Display result codes
    4UP
    DOWNEc ho offline c ommand s
    No echo, offline commands
    5UP
    DOWNAuto answer on first ring or higher if specified in NVRAM
    Auto answer off
    6UP
    DOWNCarrier detec t normal
    Carrier detect override
    7UP
    DOWNLoad  NVRAM defaults
    Load factory defaults
    8UP
    DOWNDumb  mode
    Smart mode
    Baud  rate 9600
    Data b its 8
    Pa r it y N o n e
    Stop  b its 1
    Flow c ontrol hard ware 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-13 Activate the System 
    3
    Activate the System
    !CAUTION:
    It may b e nec essary to reseat c irc uit p ac ks. To p revent d amag e from static  
    elec tric ity, always wear an Elec tromag netic  Comp atib ility (EMC) wrist strap  
    (c omc od e 900698226) when hand ling  all system c omp onents.
    Install Translation Flash Memory Card
    1. Verify the write switc h on the Translation Flash-Memory Card  (Translation 
    Card ) is positioned  d own so the c ard  c an b e written to. See Figure 3-14
    .
    2. Insert the Translation Card  into the TN794 Network Control/Pac ket 
    Interfac e (Net/Pkt) c irc uit p ac k in the d irec tion ind ic ated  b y the arrow on 
    the lab el.
    Power Up AC-Powered System
    1. Set the assoc iated  c irc uit b reakers on the AC p ower panel ON
    .
    NOTE:
    If the system is high or c ritic al reliab ility, p ower-up  the Exp ansion 
    Port Network (EPN) first, then the Proc essor Port Network (PPN). 
    Always p ower up  the c ontrol c ab inet last.
    2. At the rear of eac h c ab inet, set the c irc uit b reaker to ON
    . This starts the 
    system initialization and test. Some red lights may be on but will be turned 
    off b y other p roc ed ures in this c hap ter.
    3. Skip  to ‘‘Verify Messag es on Terminal’’ on p ag e 3-15
    . 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-14 Activate the System 
    3
    Figure 3-6. Write Switch on Translation Card
    Power Up DC-Powered System
    NOTE:
    If the system is high or c ritic al reliab ility, p ower-up  the Exp ansion Port 
    Network (EPN) first, then the Proc essor Port Network (PPN). 
    Always power 
    up  the c ontrol c ab inet
     last.
    1. At the DC Battery Cab inet (if installed ), set the c irc uit breaker to ON
    .
    2. At the DC Power Cab inet, set the c irc uit b reakers on the assoc iated 
    rec tifiers ON
    .
    3. At the rear of eac h Power Distribution Unit (if installed ), set the c irc uit 
    breaker to ON
    .
    This starts the system initialization and  test. Some red  lig hts may b e on but will b e 
    turned  off b y other p roc ed ures in this c hap ter.Figure Notes
    1. Slot in TN794 Network Control/Pac ket 
    Control Circ uit Pac k
    2. Insert Card  in Direc tion of Arrow3. Write Switc h Positioned  Down
    netcon KLC 053196 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-15 Activate the System 
    3
    Verify Messages on Terminal
    1. After several minutes, verify all tests p ass. Sc reen 3-1 d isp lays the sc reen 
    of a typ ic al Release 8si system.
    NOTE:
    If any of the terminal messag es ind ic ate a test has failed  or if the 
    message spe down mode
     is d isp layed , refer to 
    DEFINITY 
    Enterprise Communic ations Server Release 8 Maintenanc e for R8si, 
    to c lear the troub le, or c all your Luc ent Tec hnolog ies rep resentative.
    Screen 3-1. Typical Start-up Messages 
    2. Ab out two minutes after REBOOT PERFORMED
     is displayed , verify the 
    sc reen d isp lays: Login:
    CONTROL STATUS TEST
    DCACHE TEST
    ICACHE TEST
    WRITE BUFFER TEST
    BTO TEST
    INTERNAL REGISTER TESTPASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED
    PASSED MEM CONFIG TEST
    MEMORY FUNCTIONAL TEST
    MEMORY MODULE A PARITY TESTMEMORY MODULE A STUCK BIT TEST
    MEMORY MODULE A BURST TEST
    MEMORY MODULE B PARITY TESTMEMORY MODULE B STUCK BIT TEST
    MEMORY MODULE B BURST TEST
    MEMORY MODULE C PARITY TESTMEMORY MODULE C STUCK BIT TEST
    MEMORY MODULE C BURST TEST
    VIRTUAL MEMORY TEST
    EXCEPTION TEST
    TIMER TEST
    MTP TEST
    SANITY TIMER TEST
    ADDRESS MATCHER TEST
    FLASH TEXT CHECKSUM TEST
    RAM DATA CHECKSUM TEST
    RESET 4 (REBOOT PERFORMED)LOOP DATA TEST
    DUART TEST
    ROM CHECKSUM TEST 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-16 Screens and Commands 
    3
    Screens and Commands
    Screens
    The system is ad ministered  using  sc reens d isp layed  on the terminal. The 
    sc reens are used  to ad d , c hang e, d isp lay, list d ata, and  to remove system and  
    telep hone features. To ac c ess a sc reen, enter a valid system c ommand in 
    resp onse to the command: 
    prompt.
    Commands
    System c ommand s are stand ard word s and phrases instruc ting the system to 
    p erform a spec ific  func tion. The c ommand s are arranged  in a hierarc hy of 
    keyword s; that is, enter one c ommand  to g o to a different level. The c ommand s 
    c ontain three parts: ACTION, OBJECT, and  QUALIFIER.
    nACTION is the first p art of the c ommand . When command:
     ap p ears on the 
    sc reen. The ACTION sp ec ifies the op eration d esired . Examp les inc lude 
    add,
     duplicate,
     change,
     remove,
     display,
     list,
     and save.
    nOBJECT is the sec ond  p art of the c ommand  and  sp ec ifies the p artic ular 
    ob jec t to b e ad ministered . Typ ic al entries are hunt-group,
     coverage 
    path,
     and station.
    nQUALIFIER is the last p art of the c ommand . It is one or more word s or 
    d ig its used  to further id entify or c omp lete the OBJECT. For examp le, 
    hunt 
    g roup 15
     or station 3600, where 15 and  3600 are q ualifiers.
    An examp le of the c ommand  line req uired  to ad d  a station with extension numb er 
    1234 is add station 1234
    . In this examp le, add
     is the ACTION, station
     is the 
    OBJECT, and  1234
     is the QUALIFIER. In the c ommand  line, spac es are req uired  
    b etween the ACTION, OBJECT, and  QUALIFIER.
    To save time, enter enoug h letters for eac h p art of the c ommand to make it 
    uniq ue. For examp le, if you want to enter the c ommand  change 
    system-parameters country-options
    , typ ing  cha sys coun
     is sufficient.
    NOTE:
    The c raft log in may not b e allowed  to p erform some of the steps need ed  
    to initialize the system. If ac c ess is denied  to some of these p roc ed ures, 
    c ontac t your Luc ent Tec hnologies representative for assistanc e.
    Getting Help
    Use the HELP key for a list of op tions and  the CANCEL key to b ac k out of any 
    c ommand . Refer to 
    DEFINITY Enterp rise Communic ations Server Release 8 
    Ad ministration and  Feature Desc ription
    , for d etailed  p roc ed ures. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-17 Administer the System 
    3
    Administer the System
    Contac t the reg ional CSA (Customer Software Assoc iate) to req uest an “ init”  
    login. The CSA assig ns the Offer Categ ory op tion. This op tion must b e set b efore 
    c ontinuing  with this installation. Limited  c ommand  op tions are availab le until this 
    op tion is set. 
    Log into the System
    1. Verify the sc reen d isp lays Login:
    2. Type craft
     and  p ress 
    EN TER.
    3. Verify the sc reen d isp lays password
    :
    4. Type crftpw
     and press
     EN TER.  For sec urity reasons, the p assword is not 
    displayed as it is typed. The system verifies a valid login and password 
    name were entered . If an invalid  log in or p assword  name was entered , the 
    sc reen d isp lays login incorrect:
    In this c ase, repeat the p roc ed ure using  the c orrec t log in and  matc hing  
    password.
    If the system rec og nizes the log in and  p assword  name, the sc reen 
    d isp lays the software version.
    5. Verify the sc reen d isp lay is similar to:
    Terminal Type (513, 715, 4410, 4425, VT220): [715]
    6. Typ e the numb er of the manag ement terminal and  p ress 
    EN TER.
    7. Verify the sc reen d isp lays command
    :
    NOTE:
    The following  sec tions d esc rib e some of the p roc ed ures used  to ac c ess 
    and  c hang e c ertain op tions. These sec tions are not intend ed  to rep lac e or 
    mod ify the instruc tions p rovid ed  in 
    DEFINITY Enterp rise Communic ations 
    Server Release 8 Ad ministration and  Feature Desc rip tion
    . 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-18 Administer the System 
    3
    Change Customer Options
    The following features are p art of the b asic  software p ac kag e and  d o not need  to 
    b e ac tivated . They d efault to y
     (yes) on the Op tional Features sc reen.
    nARS/AAR Partitioning
    nEmerg enc y Ac c ess to Attend ant
    nHosp itality (Basic )
    nService Ob serving
    Use the following  p roc ed ure to c hang e the c ustomer’s optional features.
    1. At the command:
     promp t, enter the change system-parameters 
    customer-options
     and press 
    En te r. A d isp lay similar to Sc reen 3-2 
    ap p ears.
    Screen 3-2. Typical Customer-Options Form 
    2. Using  the Customer Ord er, enab le the op tional features purc hased  b y the 
    c ustomer (as shown b y PEC c od es on the Customer Ord er).
    In Release 8 systems, a sep arate sc reen offers ASAI c ap ab ility g roup s for 
    selec tion in c ases where the ASAI interfac e has b een enab led . Chang e 
    this sc reen in the same manner as Pag e 1 of the c ustomer-op tions form.
    3. When finished , log off and  b ac k in to effec t the c hanges.
    change system-parameters customer-options                      Page   1 of 6
                               OPTIONAL FEATURES                        
                     G3 Version: V8
                       Location: 1
      
               G3 Version: V8                  Maximum Ports: 100
                 Location: 1        Maximum XMOBILE Stations: 0
                                        Maximum H.323 Trunks: 10
                                      Maximum H.323 Stations: 10
                                       Maximum IP SoftPhones: 10
            (NOTE: You must logoff & login to effect the permission changes.) 
    						