Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual
Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-9 Access the System 3 . Setting the Data Module Operating Mode 1. Connec t an RS-232 c ab le from the DSA/DNA c omp uter to the d ata mod ule. If you are using an 8400B+ , c onnec t the DSA/DNA c omp uter to the data module using the supplied adapter cable. 2. Using a terminal emulator, c onnec t to the serial p ort to whic h the d ata mod ule is c onnec ted , and set the emulation to vt100 mod e. 3. Type AT at the p romp t and p ress En t e r.The d ata mod ule should return an OK. If it d oes not, b e sure that a stand ard RS-232 or EIA-232 c ab le is connec ted (not a null modem c able). 4. Set the operating mode as described in the following table. 5. Disc onnec t the terminal from the d ata mod ule and rec onnec t the d ata mod ule to the system c ab ling . Ty p e o f Data Module How to Test and Troubleshoot 8400B+ The red LED should b e stead y on. If the red and g reen LEDs are b linking , the unit is not c ommunic ating with the DEFINITY ECS. Chec k the wiring at the MDF, wall jac k, and the 8400B+ . 7400B+ The Power and TR LEDs should b e stead y on. If the Power and Data LEDs are b linking , the unit is not c ommunic ating with the DEFINITY ECS. Chec k the wiring at the MDF, wall jac k, and the 7400B+ . 7400A Set the 7400A to DCE mod e. The Power LED must b e stead y on. The DTR, DSR, DCD, RTS, and CTS setting s must b e hig hlig hted in the d isp lay. If the Power LED is b linking , the d ata mod ule is not c ommunic ating with the DEFINITY ECS. Chec k the wiring at the MDF, wall jac k, and 7400A. Ty p e o f Data Module How to set the operating mode 8400B+ Typ e AT&F and press En t e r. Typ e ATS24=1 and press En te r. Type AT&WØ and press En t e r to save the operating mode into non-volatile RAM. 7400A 7400B+Ty p e AT&F and press En t e r. Typ e AT&WØ and press En te r to save the op erating mod e into non-volatile RAM.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-10 Access the System 3 Setting the 7400B+ Options 1. Set the DIP switc hes for the 7400B+ using Tab le 3-3. The DIP switc hes are loc ated insid e the unit. To ac c ess them a. Remove the p ower c ord from the unit. b . Remove the c over from the top rear of the unit. c . Set the d ip switc hes. d . Rep lac e the c over. e. Connect the power c ord.The unit performs a self test. 2. If any switc hes were set in step 1, c yc le the p ower to the d ata mod ule so that the firmware c an read the new switc h setting s. Table 3-3. DIP Switch Settings (7400B+) Option DIP Switch Setting No Telep hone Connec ted 1 On Data Metering 5 Off Sup p ress Touc h-tone/Dial Tone 6 Off Sp eakerp hone Disab le/Enab le 7 Off Busyout on Loc al Loop 8 Off Unused DIP Switc hes 2, 3, and 4 Off
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-11 Access the System 3 Connecting by analog modem to INADS port You c an c onnec t a PC to the DEFINITY ECS throug h a mod em. 1. Connec t the eq uip ment as shown in Fi g u re 3 - 5 . Figure 3-5. A typical remote connection through a modem to access a remote DEFINITY ECS Follow these step s to c onnec t to the DEFINITY ECS through a mod em. 1. Connec t the c omp uter to the mod em. 2. Connec t an analog telephone line to the left most analog -line p ort on the mod em. 3.Make sure that the mod em’s DIP switc hes are set as shown in Ta b l e 3 - 4 . Figure Notes 1. Comp uter with DSA or DNA 2. 50-ft (15-m) M25A c ab le (RS-232— 9-25 p in ad ap ter if need ed ) 3. Analog mod em 4. 7-ft (2-m) D2W mod ular c ord 5. 103A or Luc ent mod ular wall jac k 6. Main d istrib ution frame (MDF)7. Analog line circuit pack 8. Analog trunk c irc uit p ac k Pac ket d ata line (R8r) Data line (R8r) 9. DEFINITY ECS 10. B25A c ab le 11. Analog line cydr0031 LJK 021800 1 2 3 11 4 5 78 9 1010 6
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-12 Access the System 3 4. Plug the mod em into an AC p ower outlet. 5. Turn on the modem. 6. Set the following p ort setting s: Table 3-4. U.S. Robotics Modem Dip Switch Settings Dip Switch Setting Description 1UP DOWNData Terminal Ready normal Data Terminal Ready override 2UP DOWNVe r b a l re su lt c o d e s Numeric result codes 3UP DOWNSuppress result codes Display result codes 4UP DOWNEc ho offline c ommand s No echo, offline commands 5UP DOWNAuto answer on first ring or higher if specified in NVRAM Auto answer off 6UP DOWNCarrier detec t normal Carrier detect override 7UP DOWNLoad NVRAM defaults Load factory defaults 8UP DOWNDumb mode Smart mode Baud rate 9600 Data b its 8 Pa r it y N o n e Stop b its 1 Flow c ontrol hard ware
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-13 Activate the System 3 Activate the System !CAUTION: It may b e nec essary to reseat c irc uit p ac ks. To p revent d amag e from static elec tric ity, always wear an Elec tromag netic Comp atib ility (EMC) wrist strap (c omc od e 900698226) when hand ling all system c omp onents. Install Translation Flash Memory Card 1. Verify the write switc h on the Translation Flash-Memory Card (Translation Card ) is positioned d own so the c ard c an b e written to. See Figure 3-14 . 2. Insert the Translation Card into the TN794 Network Control/Pac ket Interfac e (Net/Pkt) c irc uit p ac k in the d irec tion ind ic ated b y the arrow on the lab el. Power Up AC-Powered System 1. Set the assoc iated c irc uit b reakers on the AC p ower panel ON . NOTE: If the system is high or c ritic al reliab ility, p ower-up the Exp ansion Port Network (EPN) first, then the Proc essor Port Network (PPN). Always p ower up the c ontrol c ab inet last. 2. At the rear of eac h c ab inet, set the c irc uit b reaker to ON . This starts the system initialization and test. Some red lights may be on but will be turned off b y other p roc ed ures in this c hap ter. 3. Skip to ‘‘Verify Messag es on Terminal’’ on p ag e 3-15 .
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-14 Activate the System 3 Figure 3-6. Write Switch on Translation Card Power Up DC-Powered System NOTE: If the system is high or c ritic al reliab ility, p ower-up the Exp ansion Port Network (EPN) first, then the Proc essor Port Network (PPN). Always power up the c ontrol c ab inet last. 1. At the DC Battery Cab inet (if installed ), set the c irc uit breaker to ON . 2. At the DC Power Cab inet, set the c irc uit b reakers on the assoc iated rec tifiers ON . 3. At the rear of eac h Power Distribution Unit (if installed ), set the c irc uit breaker to ON . This starts the system initialization and test. Some red lig hts may b e on but will b e turned off b y other p roc ed ures in this c hap ter.Figure Notes 1. Slot in TN794 Network Control/Pac ket Control Circ uit Pac k 2. Insert Card in Direc tion of Arrow3. Write Switc h Positioned Down netcon KLC 053196
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-15 Activate the System 3 Verify Messages on Terminal 1. After several minutes, verify all tests p ass. Sc reen 3-1 d isp lays the sc reen of a typ ic al Release 8si system. NOTE: If any of the terminal messag es ind ic ate a test has failed or if the message spe down mode is d isp layed , refer to DEFINITY Enterprise Communic ations Server Release 8 Maintenanc e for R8si, to c lear the troub le, or c all your Luc ent Tec hnolog ies rep resentative. Screen 3-1. Typical Start-up Messages 2. Ab out two minutes after REBOOT PERFORMED is displayed , verify the sc reen d isp lays: Login: CONTROL STATUS TEST DCACHE TEST ICACHE TEST WRITE BUFFER TEST BTO TEST INTERNAL REGISTER TESTPASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED MEM CONFIG TEST MEMORY FUNCTIONAL TEST MEMORY MODULE A PARITY TESTMEMORY MODULE A STUCK BIT TEST MEMORY MODULE A BURST TEST MEMORY MODULE B PARITY TESTMEMORY MODULE B STUCK BIT TEST MEMORY MODULE B BURST TEST MEMORY MODULE C PARITY TESTMEMORY MODULE C STUCK BIT TEST MEMORY MODULE C BURST TEST VIRTUAL MEMORY TEST EXCEPTION TEST TIMER TEST MTP TEST SANITY TIMER TEST ADDRESS MATCHER TEST FLASH TEXT CHECKSUM TEST RAM DATA CHECKSUM TEST RESET 4 (REBOOT PERFORMED)LOOP DATA TEST DUART TEST ROM CHECKSUM TEST
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-16 Screens and Commands 3 Screens and Commands Screens The system is ad ministered using sc reens d isp layed on the terminal. The sc reens are used to ad d , c hang e, d isp lay, list d ata, and to remove system and telep hone features. To ac c ess a sc reen, enter a valid system c ommand in resp onse to the command: prompt. Commands System c ommand s are stand ard word s and phrases instruc ting the system to p erform a spec ific func tion. The c ommand s are arranged in a hierarc hy of keyword s; that is, enter one c ommand to g o to a different level. The c ommand s c ontain three parts: ACTION, OBJECT, and QUALIFIER. nACTION is the first p art of the c ommand . When command: ap p ears on the sc reen. The ACTION sp ec ifies the op eration d esired . Examp les inc lude add, duplicate, change, remove, display, list, and save. nOBJECT is the sec ond p art of the c ommand and sp ec ifies the p artic ular ob jec t to b e ad ministered . Typ ic al entries are hunt-group, coverage path, and station. nQUALIFIER is the last p art of the c ommand . It is one or more word s or d ig its used to further id entify or c omp lete the OBJECT. For examp le, hunt g roup 15 or station 3600, where 15 and 3600 are q ualifiers. An examp le of the c ommand line req uired to ad d a station with extension numb er 1234 is add station 1234 . In this examp le, add is the ACTION, station is the OBJECT, and 1234 is the QUALIFIER. In the c ommand line, spac es are req uired b etween the ACTION, OBJECT, and QUALIFIER. To save time, enter enoug h letters for eac h p art of the c ommand to make it uniq ue. For examp le, if you want to enter the c ommand change system-parameters country-options , typ ing cha sys coun is sufficient. NOTE: The c raft log in may not b e allowed to p erform some of the steps need ed to initialize the system. If ac c ess is denied to some of these p roc ed ures, c ontac t your Luc ent Tec hnologies representative for assistanc e. Getting Help Use the HELP key for a list of op tions and the CANCEL key to b ac k out of any c ommand . Refer to DEFINITY Enterp rise Communic ations Server Release 8 Ad ministration and Feature Desc ription , for d etailed p roc ed ures.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-17 Administer the System 3 Administer the System Contac t the reg ional CSA (Customer Software Assoc iate) to req uest an “ init” login. The CSA assig ns the Offer Categ ory op tion. This op tion must b e set b efore c ontinuing with this installation. Limited c ommand op tions are availab le until this op tion is set. Log into the System 1. Verify the sc reen d isp lays Login: 2. Type craft and p ress EN TER. 3. Verify the sc reen d isp lays password : 4. Type crftpw and press EN TER. For sec urity reasons, the p assword is not displayed as it is typed. The system verifies a valid login and password name were entered . If an invalid log in or p assword name was entered , the sc reen d isp lays login incorrect: In this c ase, repeat the p roc ed ure using the c orrec t log in and matc hing password. If the system rec og nizes the log in and p assword name, the sc reen d isp lays the software version. 5. Verify the sc reen d isp lay is similar to: Terminal Type (513, 715, 4410, 4425, VT220): [715] 6. Typ e the numb er of the manag ement terminal and p ress EN TER. 7. Verify the sc reen d isp lays command : NOTE: The following sec tions d esc rib e some of the p roc ed ures used to ac c ess and c hang e c ertain op tions. These sec tions are not intend ed to rep lac e or mod ify the instruc tions p rovid ed in DEFINITY Enterp rise Communic ations Server Release 8 Ad ministration and Feature Desc rip tion .
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-18 Administer the System 3 Change Customer Options The following features are p art of the b asic software p ac kag e and d o not need to b e ac tivated . They d efault to y (yes) on the Op tional Features sc reen. nARS/AAR Partitioning nEmerg enc y Ac c ess to Attend ant nHosp itality (Basic ) nService Ob serving Use the following p roc ed ure to c hang e the c ustomer’s optional features. 1. At the command: promp t, enter the change system-parameters customer-options and press En te r. A d isp lay similar to Sc reen 3-2 ap p ears. Screen 3-2. Typical Customer-Options Form 2. Using the Customer Ord er, enab le the op tional features purc hased b y the c ustomer (as shown b y PEC c od es on the Customer Ord er). In Release 8 systems, a sep arate sc reen offers ASAI c ap ab ility g roup s for selec tion in c ases where the ASAI interfac e has b een enab led . Chang e this sc reen in the same manner as Pag e 1 of the c ustomer-op tions form. 3. When finished , log off and b ac k in to effec t the c hanges. change system-parameters customer-options Page 1 of 6 OPTIONAL FEATURES G3 Version: V8 Location: 1 G3 Version: V8 Maximum Ports: 100 Location: 1 Maximum XMOBILE Stations: 0 Maximum H.323 Trunks: 10 Maximum H.323 Stations: 10 Maximum IP SoftPhones: 10 (NOTE: You must logoff & login to effect the permission changes.)