Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test the System 4-5 Test Time Division Multiplexing Bus in Processor Port Network 4 Test Time Division Multiplexing Bus in Processor Port Network 1. Verify the sc reen d isp lays command: 2. Type test tdm port-network 1 and p ress En t e r. 3. Verify the sc reen d isp lays the results of this test. See Sc reen 4-4 . Screen 4-4. Sample Test Results for TDM Bus Port Network 1 4. If the result is FAIL for any test, c hec k the c onnec tors of the TDM b us c ab les in Proc essor Port Network (PPN) 1. test tdm port-network 1 TEST RESULTS Port Maintenance Name Alt. Name Test No. Result Error Code PN 01A TDM-BUS 294 PASS PN 01A TDM-BUS 296 PASS PN 01A TDM-BUS 297 ABORT 1005 PN 01B TDM-BUS 294 PASS PN 01B TDM-BUS 296 ABORT 1005 PN 01B TDM-BUS 297 PASS Command successfully completed Command:
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test the System 4-6 Test Tone-Clock Boards 4 Test Tone-Clock Boards Testing the Tone-Clock board also detects problems with the TDM bus cables. 1. Verify the sc reen d isp lays command: 2. Type test tone-clock 1a and p ress En t e r. 3. Verify pag e 1 disp lays the test results similar to Sc reen 4-5 . Screen 4-5. Sample Test Results for Tone-Clock 1A test tone-clock 1a TEST RESULTS Port Maintenance Name Alt. Name Test No. Result Error Code 01A TONE-BD 46 PASS 01A TONE-BD 52 PASS 01AXX01 ETR-PT 42 PASS 01AXX01 ETR-PT 43 PASS 01AXX02 ETR-PT 42 PASS 01AXX02 ETR-PT 43 PASS 01AXX03 ETR-PT 42 PASS 01AXX03 ETR-PT 43 PASS 01AXX04 ETR-PT 42 PASS 01AXX04 ETR-PT 43 PASS 01AXX05 ETR-PT 42 PASS 01AXX05 ETR-PT 43 PASS 01AXX06 ETR-PT 42 PASS 01AXX06 ETR-PT 43 PASS Command successfully completed Command:
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test the System 4-7 Test Expansion Interface Circuit Packs 4 Test Expansion Interface Circuit Packs Chec k eac h Expansion Interfac e (EI) c irc uit pac k in the system. 1. Verify the sc reen d isp lays command: 2. Type test board xxx where xxx is the c ab inet, c arrier, and slot for an Exp ansion Interfac e (EI) c irc uit p ac k in the system, and p ress En te r. NOTE: Lab els on the p ort network and c arrier and on the strip und er the c irc uit pac k c ontain this information. 3. Verify the sc reen d isp lays test results similar to Sc re e n 4 - 6 . This examp le is for b oard 2a01. Screen 4-6. Sample Test Results for Expansion Interface Board 2A01 4. If any result is FAIL, c hec k the c onnec tions for the fib er optic link. 5. Rep eat Step s 2 and 3 for eac h Exp ansion Interfac e c irc uit p ac k. TEST RESULTS Port Maintenance Name Alt. Name Test No. Result Error Code 02A01 EXP-INTF 237 PASS 02A01 EXP-INTF 238 PASS 02A01 EXP-INTF 240 PASS 02A01 EXP-INTF 241 PASS 02A01 EXP-INTF 244 PASS 02A01 EXP-INTF 316 PASS
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test the System 4-8 Test Time Division Multiplexing Bus for Each Expansion Port Network 4 Test Time Division Multiplexing Bus for Each Expansion Port Network Check eac h TDM bus for each Expansion Port Network (EPN) in the system. 1. Verify the sc reen d isp lays command: 2. Type test tdm port-network 2 and p ress En t e r. 3. Verify a test results sc reen similar to Sc reen 4-7 is d isp layed : Screen 4-7. Sample Test Results for Time Division Multiplexing Bus Port Network 2 4. If result is FAIL for any test, c hec k the c onnec tors of the TDM b us c ab les in Pro c e ss o r Po r t N e t w o r k (PPN ) 2 . 5. Rep eat these step s for eac h Exp ansion Port Network (EPN) to c hec k the TDM bus cables. test tdm port-network 2 TEST RESULTS Port Maintenance Name Alt. Name Test No. Result Error Code PN 02A TDM-BUS 294 PASS PN 02A TDM-BUS 296 PASS PN 02A TDM-BUS 297 ABORT 1005 PN 02B TDM-BUS 294 PASS PN 02B TDM-BUS 296 ABORT 1005 PN 02B TDM-BUS 297 PASS Command successfully completed Command:
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test the System 4-9 Test Tone-Clock for Each Expansion Port Network 4 Test Tone-Clock for Each Expansion Port Network 1. Verify the sc reen d isp lays command: 2. Type test tone-clock 2A where 2A is the c abinet and c arrier numb er for one of the Tone-Cloc ks installed , and p ress En t e r. If any result is FAIL , c hec k the assoc iated TDM b us c ables and interc ab inet c ab les in the Exp ansion Port Network (EPN). 3. Rep eat Step 2 for eac h installed Tone-Cloc k c irc uit pac k. Test Tone-Clock Interchange for Each Expansion Port Network If the system is c ritic al reliab ility, test the Tone-Cloc k interc hang e for eac h Exp a n si o n Po r t N e t w o rk ( EPN ). 1. Verify the sc reen d isp lays command: 2. Type status system all-cabinets and press En t e r. This d isp lays the loc ation of the Stand b y Tone-Cloc k. 3. Type set tone-clock xx where xx is the Port-Network/Carrier for the St a n d b y To n e - C lo c k . Pre s s En te r. 4. Type status system all-cabinets and press En t e r. 5. Verify the dup lic ated Tone-Cloc k is ac tive using the information d isplayed on the sc reen. If any p rob lems are ind ic ated , c hec k the TDM c ab les in the assoc iated Exp a n si o n Po r t N e t w o rk ( EPN ).
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test the System 4-10 Test Expansion Interface Exchange for Each Expansion Port Network 4 Test Expansion Interface Exchange for Each Expansion Port Network If the system is c ritic al reliab ility, test the exp ansion interfac e exc hang e for eac h Exp a n si o n Po r t N e t w o rk ( EPN ). 1. Verify the sc reen d isp lays command: 2. Type status system all-cabinets and press En t e r. This d isp lays the stand b y exp ansion link. See Sc reen 4-8 . Screen 4-8. Sample of System Status before Expansion Link is Set 3. Type set expansion-link xxxx where xxxx is the either one of the c ab inet, c arrier, and p ort loc ations of the standb y exp ansion link. 4. Verify the sc reen d isp lays: Command successfully completed Command: 5. Type status system all-cabinets and press En t e r. A sc reen similar to Sc reen 4-9 is displayed. status system all-cabinets SYSTEM STATUS CABINET 1 EMERGENCY SELECT SERVICE CABINET TRANSFER SWITCH EXP-LINK STATE MODE TYPE 1A unavail 01A01-02A01 in standby ESCC 1B auto-on 01B01-02B02 in active - - Command successfully completed Command:
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test the System 4-11 Check Circuit Pack Configuration 4 Screen 4-9. Sample of System Status after Expansion Link is Set 6. Verify the MODE s of the exp ansion links have c hang ed . 7. If any prob lems are ind ic ated , c hec k the TDM c ab les and the inter-c ab inet c ab les (ICC) in the assoc iated Exp ansion Port Network (EPN). Check Circuit Pack Configuration 1. Verify the sc reen d isp lays command: 2. Type list configuration all and p ress En t e r. 3. Verify all circuit packs are listed in the reports. Refer to DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8si , to resolve any d isc rep anc ies. Save Translations, if Required If any ad ministration c hang es have b een mad e, save and make a b ac k up c op y of the translations. See Chap ter 3, ‘‘Ac c essing and Ac tivating the System’’ for instruc tions. status system all-cabinets SYSTEM STATUS CABINET 1 EMERGENCY SELECT SERVICE CABINET TRANSFER SWITCH EXP-LINK STATE MODE TYPE 1A auto-on 01A01-02A01 in active ESCC 1B auto-on 01B01-02B02 in standby Command successfully completed Command:
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test the System 4-12 Next Steps 4 Next Steps 1. Install the telep hones and other equip ment. These p roc ed ures are in Chapter 5, ‘‘Install and Wire Telep hones and Other Eq uip ment’’ . 2. Ad minister the features, telep hones, and other eq uipment ac c ord ing to c ustomer d ata found on the p rovisioning p lan. Use the p roc ed ures in DEFINITY Enterp rise Communic ations Server Release 8 Ad ministration and Feature Desc rip tion . 3. After the system is administered , test the telep hones and other eq uip ment using Chap ter 6, ‘‘Test Telep hones and Other Eq uip ment’’ . NOTE: It may b e more effic ient to install eac h hard ware c omp onent, ad minister it, and test it b efore g oing on to install another c omp onent. As an examp le, install the attend ant c onsole using the p roc ed ures in Chap ter 5, ‘‘Install and Wire Telephones and Other Eq uip ment’’, ad minister it using the p roc ed ures in DEFINITY Enterprise Communic ations Server Release 8 Ad ministration and Feature Desc rip tion , and test it using the p roc ed ures in Chap ter 6, ‘‘Test Telep hones and Other Eq uip ment’’. !CAUTION: To p revent unnec essary troub le tic kets, d o not enab le the system alarms (Alarm Orig ination feature) until all installation and ad ministration p roc ed ures are c ompleted .
Install and Wire Telephones and Other Equipment 5-1 Voice and Data Terminals 5 DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 5 Install and Wire Telephones and Other Equipment The wiring p roc ed ures are the same for most of the DEFINITY System telep hones and other eq uip ment. This sec tion p rovid es wiring examp les of these similar installation p roc ed ures. These are examp les only and ac tual wiring p roc ed ures may vary at eac h site. All wiring p inouts for all c irc uit p ac ks in this c hap ter c an b e found in the tab les at the end of this c hap ter. Voice and Data Terminals The system c an b e c onnec ted to all DTE terminals and have RS-232 (or EIA-232) or DCP interfac es. Telephone Connection Example The 302C1 Attend ant Console is used to desc rib e a typic al telep hone c onnec tion. This information is typ ic al of the 603E, 84xx (4-wire), and 94xx telep hones. The attend ant c onsole always req uires auxiliary (ad junc t) power (-48 VDC). Power is c onnec ted to the c onsole throug h Pins 7 and 8 of the information outlet. See Fig ure 5-1 . Only three c onsoles c an b e powered b y the system throug h the AUX c onnec tor. When p ossib le, the p rimary c onsole should b e p owered from the system so it has the same p ower failure b ac kup as the system. The maximum c abling d istanc e for the c onsole p owered from the c ab inet is 350 feet (100 meters).
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-2 Telephone Connection Example 5 The g eneral step s to c onnec t a telep hone are: 1. Choose a d evic e to c onnec t suc h as a 302C1 Attend ant Console. 2. Choose the port circuit pac k and its carrier and slot number, such as c ab inet 1, c arrier C, slot 02. 3. Choose a p ort c irc uit on the p ort c irc uit pac k. Suc h as Port 05. Figure 5-1. 302C1 to 4-wire DCP Wiring 4. Install c ross-c onnec t jump ers to wire the terminal to the p ort c irc uit p ac k. See Fig ure 5-1 . This p inout is for the 4-wire Dig ital Line c irc uit p ac k. 5. For terminals need ing ad junc t p ower, wire -48 VDC and g round to ap p rop riate p ins on the terminal. See Fig ure 5-1 . Figure Notes 1. 302C1 Attend ant Console 2. 4-wire Dig ital Line Circ uit Pac k (Position 1C02)3. -48 VDC From Ad junc t Power 4. Ground From Ad junc t Power 302cwire RBP 040596 139 14 40 15 2 3 6 7 8 TXT TXR PXT PXRTXT5 TXR5 PXT5 PXR5