    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-93 Add CallVisor ASAI 
    5
    Add CallVisor ASAI
    Service Interruption
    1. If ad d ing  the pac ket b us sup p ort and  TN570s must b e installed  as part of 
    that sup p ort, then ad d ing  CallVisor ASAI req uires a servic e interrup tion. 
    Notify the c ustomer in ad vanc e as to when the ad d ition will take p lac e. 
    See ‘‘Add Packet Bus Support to R8si’’ on page 5-87
     for further 
    information.
    Enter Added Translations
    1. On the System-Parameters Customer-Op tions form, disab le the Calling  
    Party Numb er/Billing  Numb er (CPN/BN) op tion, and  enab le the CallVisor 
    ASAI Interfac e op tion. 
    2. See 
    DEFINITY Enterp rise Communic ations Server Release 8 
    Ad ministrator’s Guid e
    , for d etails on d isab ling  and  enab ling these op tions.
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    Add Packet Bus Support
    1. If p ac ket b us sup p ort is not alread y installed , see ‘‘Add Packet Bus 
    Support to R8si’’ on page 5-87 and  p erform the step s. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-94 Add CallVisor ASAI 
    5
    Add Circuit Packs
    1. Determine port assig nment of c irc uit p ac ks to be ad d ed .
    2. Install the ap p rop riate c irc uit pac ks in assigned  c ab inet slot (as req uired ).
    The TN748B (or later) or TN744/C/D Call Classifier c irc uit p ac k is req uired . 
    The TN744 is req uired  for those c ustomers who d esire switc h c all 
    c lassific ation.
    A vac ant p ort is req uired on a TN556/B ISDN—BRI circuit pack.
    Install Cables
    1. Install c ab les from c ab inet to the MDF as req uired .
    Enter Added Translations
    1. Ad minister the req uired  translation d ata using the forms listed und er 
    “ Ad junc t/Switc h Ap p lic ations Interfac e (ASAI)”  in 
    DEFINITY Enterp rise 
    Communic ations Server Release 8 Ad ministrator’s Guid e
    .
    Resolve Alarms
    1. Examine the alarm log. Resolve any alarms that may exist using  D EFI N I TY 
    Enterp rise Communic ations Server Release 8 Maintenanc e for R8si
    . 
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    3. Up d ate b ac kup  translation c ard s, if required .
    EXAMPLE:1 A 07 01
    Cab inet (Port 
    Network)Carrier Slot 
    Numb erPo rt  
    Number 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-95 Add ISDN—BRI 
    5
    Add ISDN—BRI
    Service Interruption
    1. If ad d ing  the pac ket b us sup p ort and  TN570s must b e installed  as part of 
    that sup p ort, ad d ing ISDN—BRI req uires a servic e interrup tion. Notify the 
    c ustomer in ad vanc e as to when the ad d ition will b e c arried  out. See ‘‘Add 
    Packet Bus Support to R8si’’ on page 5-87 for further information.
    Add Packet Bus Support
    1. If p ac ket b us sup p ort is not alread y installed , see ‘‘Add Packet Bus 
    Support to R8si’’ on page 5-87 and  p erform the step s.
    Add Circuit Packs
    1. Determine port assignments of circuit packs to be added.
    2. Install the ap p rop riate c irc uit pac ks in assigned  c ab inet slot (as req uired ).
    Required circuit packs:
    nTN794 Network Control/Pac ket Interfac e (Net/Pkt) c irc uit p ac k
    nTN556 or TN2198 ISDN BRI c irc uit p ac k.
    nTN570/B/C Exp ansion Interfac e c irc uit p ac k (if EPN p resent)
    Ad d  the TN794 Pac ket Interfac e c irc uit p ac k first.
    Install Cables
    1. Install the c ab les from the c ab inet to the MDF as req uired .
    NOTE:
    A TN556 ISDN BRI req uires an 8-p ort b ac kplane c ab le terminator 
    (b reakout c onnec tor); aTN2198 ISDN BRI req uires a 12-p ort 
    b ac kp lane c ab le terminator. Connec t the 25-p air c ab le to the 
    ap p rop riate terminator.
    EXAMPLE:1 A 07 01
    Cab inet (Port 
    Network)Carrier Slot 
    Numb erPo rt  
    Number 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-96 Add IP Interface Assembly 
    5
    Enter Added Translations
    1. Ad minister the req uired  translation d ata using the forms listed und er 
    7500D voic e terminals and  8500 voic e terminals in 
    DEFINITY Enterp rise 
    Communic ations Server Release 8 Ad ministrator’s Guid e
    .
    Resolve Alarms
    1. Examine the alarm log . Resolve any alarms using  DEFINITY Enterp rise 
    Communic ations Server Release 8 Maintenanc e for R8si
    . 
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    3. If the system c ontains a TN750/B/C Announc ement c irc uit pac k, typ e list 
    configuration software-version
     and  p ress 
    En t e r. To restore these 
    announc ements, typ e restore announcements
     and  press 
    En t e r.
    4. Update backup cards, if required.
    Add IP Interface Assembly
    DEFINITY ECS IP Solutions allows you to send  voic e and  fax from the DEFINITY 
    ECS throug h an Internet p rotoc ol (IP) network to other DEFINITY ECSs having  
    this feature or to other H.323 V2 c omp liant end p oints. It is imp lemented  using  the 
    TN802/B IP Interfac e, whic h is a Wind ows NT server resid ing  on the IP Interfac e 
    Assemb ly insid e the DEFINITY ECS.
    The IP Interfac e is an assemb ly c omp osed  of a TN802B c irc uit b oard, a 
    p roc essor c ard , and DSP resourc e c ard . For ord ering  p urp oses, the assemb ly is 
    id entified  as a J58890MA-1 L30, b ut for simp lic ity, we refer to it in this b ook as the 
    TN802B IP Interfac e.
    The TN802B IP Interfac e op erates in two mod es: IP Trunk, availab le with Release 
    7 or later, and  Med ia Proc essor (Med Pro), availab le with Release 8. The IP Trunk 
    mod e is Internet Telep hone Server—Enterp rise (ITS-E) c omp atib le, and  the 
    Med Pro mod e is H.323 V2 c omp atib le. The TN802B IP Interfac e is b ac kward s 
    c omp atib le and  d efaults to IP Trunk mod e.You must ad minister it to use it in 
    Med Pro mod e.
    For more information on the IP Interfac e c ap ab ilities and  limitations, refer to the 
    DEFINITY Enterp rise Communic ations Server Release 8 Overview. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-97 Add IP Interface Assembly 
    5
    The following sec tions d esc rib e the proc ess for
    nInstalling  in Med ia Proc essor Mod e
    nInstalling  in IP Trunk Mod e
    nUp g rad ing  a TN802 V3 (or later) to a TN802B (Med Pro mod e)
    !WARNING:
    When c onnec ted  remotely via p c ANYWHERE, only use the p c ANYWHERE 
    Restart Host Computer b utton on the toolb ar to restart Wind ows NT.
    Installing in Media Processor Mode
    To operate in Med Pro mod e, you must install the TN802B IP Interfac e and , if the 
    system d oes not have one, you must also install and  administer a TN799B
     C-LAN 
    c irc uit p ac k. For C-LAN administration, refer to 
    DEFINITY Enterprise 
    Communic ations Server Ad ministration for Network Connec tivity.
    If you have existing  TN802 IP Interfac e c irc uit p ac ks, you c an up g rad e them 
    either b y rep lac ing  the c irc uit p ac k with a TN802B or b y d ownload ing  the 
    TN802B firmware onto the c irc uit p ac ks (see ‘‘Up g rad e to TN802B (R8)’’ on p ag e 
    5-126). 
    Prepare for Installation
    Have the following  eq uip ment on site b efore your ship ment arrives:
    nAC p ower outlets for the mod em and  monitor.
    nThree unoc c up ied  and  ad joining  p ort slots in the DEFINITY ECS for the 
    TN802B IP Interfac e, if need ed.
    The TN802B oc c up ies only one slot, b ut it need s the two slots to its left for 
    c learanc e.
    nAn ad d itional unoc c up ied  p ort slot for the TN799B, if need ed . If you have 
    an existing TN799 c irc uit p ac k, rep lac e it with the TN799B.
    nA 10 BaseT or 10/100 BaseT Ethernet c onnec tion into your loc al area 
    network for the TN802B.
    nA 10 BaseT Ethernet c onnec tion into your loc al area network for the 
    TN799B.
    nTwo or more valid , unused  IP ad d resses on your network (one for MedPro 
    and  one for C-LAN) that c an b e assig ned  to the IP Interfac e server. You 
    also need  the subnet mask and  d efault g ateway. 
    nAn analog telep hone line reserved  (DID is okay) for the IP Interfac e 
    diagnostic modem 
    nA valid  telep hone numb er reserved  for the IP Interfac e d iag nostic  mod em  
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-98 Add IP Interface Assembly 
    5
    In ad dition if non-U.S. c ustomer:
    nMod em c omp arab le to a U.S. Rob otic s Sportster Mod el USR 33.6 EXT.
    nCable from modem to TN802B external c able assembly.
    We rec ommend  that you p rotec t your c ab inet with an uninterrup tib le power 
    system (UPS).
    Check your Shipment
    When your DEFINITY IP Trunk ord er arrives at your site, c hec k the c ontents (see 
    Tab le 5-28
    ).
    1. Insp ec t the ship p ing  c arton for d amag e b efore op ening  it. If the b ox is 
    damaged, 
    do not open it. Inform the ship p ing  c omp any, and  ask for 
    instruc tions on filing a c laim.
    2. If the b ox is und amag ed , c hec k the c ontents ag ainst the p ac king  slip . 
    Chec k the c ondition of eac h c omp onent, and note any d amag e or 
    shortag es on the p ac king  slip . The c arton should  c ontain the following  for 
    eac h IP Interfac e ord ered :
    3. Read  and  follow any d irec tions inserted  into the p ac kag e b y the fac tory.
    The TN802B external c ab le assemb ly is a bund le of c ab les with an amp henol 
    c onnec tor at the end  of the b und le and  various PC-typ e c onnec tors (VGA, 
    Universal Serial Bus [ USB] , mouse, keyb oard , Ethernet, mod em, and  COM2) at 
    the end s of the ind ivid ual c ab les. See Fig ure 5-30
    . Look for the lab el where the 
    b und le enters the amp henol c onnec tor. 
    Table 5-28. Required Hardware
    Comcode/Code Description Quantity
    108525528 TN799B C-LAN c irc uit p ac k. One TN799B 
    sup ports more than one TN802B.1
    J58890MA-1 L30 TN802B IP Interfac e Assemb ly
    1 or more
    601939804 H600-512,G1 external c ab le assembly 1 or more
    259A c onnec tor 1
    CAT5 or b etter c ab le 1
    407633999 U.S. Rob otic s Sp ortster external mod em, 
    Mod el USR 33.6 EXT (U.S. c ustomers 
    only). Non-U.S. c ustomers must p rovid e a 
    mod em c omp arab le to this mod el.1
    601087091 20-ft DB-25 serial c ab le from mod em to 
    TN802B external c ab le assemb ly (U.S. 
    c ustomers only). Non-U.S. c ustomers must 
    p rovid e a serial c ab le.1 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-99 Add IP Interface Assembly 
    5
    Figure 5-30. TN802B IP Interface External Cable Assembly
    Connect the Cables
    1. Determine into whic h p ort slots you are p utting the TN799B C-LAN and  
    TN802B IP Interfac e c irc uit p ac ks.
    NOTE:
    Make sure that at least 3 ad jac ent slots are free for the TN802B.
    From the rear of the c ab inet:
    2. If add ing  a new TN799B, c onnec t the 259A c onnec tor to the b ac kp lane 
    c onnec tor c orrespond ing  to the TN799B slot.
    3. If add ing  a new TN799B, c onnec t one end  of the DW8 c able to the 259A 
    c onnec tor. Connec t the other end  to the c ustomer’s network.
    4. Connec t the amp henol c onnec tor on the external c ab le assemb ly to the 
    b ac kp lane c onnec tor c orresp ond ing  to the TN802B slot (the hig hest 
    numb ered c onnec tor of the 3 slots req uired ) Figure Notes
    1. Amp henol c onnec tor to c onnec tor 
    c orresp ond ing  to TN802B slot
    2. To VGA monitor
    3. To USB (not used )
    4. To keyb oard5. To mouse
    6. To ethernet
    7. 25-p in male c onnec tor to mod em
    8. 25-p in male c onnec tor to COM2 
    cbdfocto AWF 122398
    2
    1
    345678 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-100 Add IP Interface Assembly 
    5
    Connect the Modem
    NOTE:
    These instruc tions are for c onnec ting  the U.S. Rob otic s modem sup p lied  to 
    U.S. c ustomers only. If using  a d ifferent mod em, follow the manufac turer’s 
    instruc tions on c onnec ting  the mod em.
    1. Connec t the RS232 p ort of the mod em to the MODEM c onnec tor of the 
    TN802B external c ab le assembly. 
    NOTE:
    Chec k the lab els near the c onnec tors; the MODEM and  COM2 
    c onnec tors look the same.
    2. Connec t an analog  telephone line to the left most analog -line p ort on the 
    mod em as shown in Fig ure 5-31
    . 
    3. Make sure that the mod em’s DIP switc hes are set as shown in 
    Fi g u re  5 - 3 1
     and Tab le 5-29.
    4. Plug  the mod em into an AC p ower outlet.
    5. Turn on the mod em using  the switc h on the front of the mod em.
    Figure 5-31. External Modem Connections for U.S. Robotics Modem Figure Notes
    1. Connec t analog  line here.
    2. DIP switc h 5 must b e up .3. Connec t MODEM c onnec tor here.
    4. Connec t p ower c onnec tor here.
    12345678
    modfrobo KLC 030499
    234
    1 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-101 Add IP Interface Assembly 
    5
    Connect the Ethernet
    1. Connec t the network c ab le to the ETHERNET c onnec tor on the TN802B 
    external c ab le assemb ly.
    NOTE:
    You need  a CAT5 or better c ab le for 100-Mb yte operation.
    Install the Circuit Packs
    !CAUTION:
    When add ing  or rep lac ing  any hard ware, b e sure to g round  yourself against 
    elec trostatic  d isc harg e (ESD) b y wearing  a g round ed  wrist strap .
    NOTE:
    The TN799B and  TN802B c irc uit p ac ks are hot-swap p ab le, so you d o not 
    need  to p ower d own the c arrier to install them.
    If you need  to remove the TN802B IP Interfac e from the c arrier at a later 
    time, shut down Wind ows NT first b y p ressing the rec essed reset button on 
    the fac ep late (see Figure 5-32
    ) of the TN802B IP Interfac e until the LCD 
    shows a flashing MSHUT *
    . When the flashing  stop s and  the asterisk 
    d isap p ears (ab out 2 min), it is safe to remove the c irc uit p ac k.
    Table 5-29. U.S. Robotics Modem Dip Switch Settings
    Dip 
    Switch Setting Description
    1UP
    DOWNData Terminal Read y normal
    Data Terminal Read y overrid e
    2UP
    DOWNVe r b a l  r e s u lt  c o d e s
    Numeric  result c od es
    3UP
    DOWNSuppress result codes
    Disp lay result cod es
    4UP
    DOWNEc ho offline c ommand s
    No ec ho, offline c ommand s
    5UP
    DOWNAuto answer on first ring or higher if specified in NVRAM
    Auto answer off
    6UP
    DOWNCarrier d etec t normal
    Carrier d etec t overrid e
    7UP
    DOWNLoad  NVRAM d efaults
    Load  fac tory d efaults
    8UP
    DOWNDumb  mod e
    Sm a rt  m o d e 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-102 Add IP Interface Assembly 
    5
    Figure 5-32. TN802B IP Interface faceplate
    NOTE:
    If rep lac ing  the existing  TN799 c irc uit p ac k, remove it first and rep lac e it 
    with the new one.
    1. Insert the TN799B c irc uit p ac k into the p ort slot id entified  earlier.
    NOTE:
    To p rop erly seat the c irc uit p ac k, p ush firmly on the front of the 
    fac ep late until the latc h reac hes the bottom rail of the c arrier. Then 
    c lose the latc h until it is fully eng ag ed . Figure Notes
    1. LCD d isp lay
    2. Reset b utton (rec essed )
    3. Red  b oard  status LED4. PCMCIA c ard slot
    5. Yellow PCMCIA d isk-in-use LED
    1
    2
    3
    4
    5
    fpdfmapd KLC 030899 
    						