Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual
Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Option Switch Settings A-11 Call Detail Recording Option Settings A Call Detail Recording Option Settings The interfac e between the system and Call Detail Rec ord ing (CDR) equip ment may b e one of the following : nData Module — Rec ommend ed op tion setting s are shown in Ta b l e A - 3. nMod em — Rec ommend ed option setting s are in mod em vend or document nTN726 Data Line c irc uit p ac k and an Async hronous Data Unit — Data mod ules or mod ems are not req uired . nConnec ted d irec tly to the DCE connector (Electronic Industries Assoc iation (EIA) Port) loc ated on the rear of the Control Carrier — data mod ules or mod ems are not req uired . A 572 Printer c an be used as an outp ut rec eiving d evic e for Call Detail Rec ord ing (CDR). The rec ommend ed option setting s for this p rinter are shown in the f o l lo w in g t a b le s. Al so , a TEL ESEER, C a ll D e t a il Re c o rd in g ( C D R) , 9 4 A L o c a l Storag e Unit (LSU), or Customer Premises Eq uip ment (CPE) c an b e used as the output receiving d evice. Ad ministration p roc ed ures for Call Detail Rec ord ing (CDR) eq uip ment are p rovid ed in DEFINITY Enterp rise Communic ations Server Release 8 Ad ministration and Feature Desc ription . AUDIX Interface Option Settings The Aud io Information Exc hang e (AUDIX) is sometimes c onnec ted to the system throug h the TN765 Proc essor Interfac e c irc uit p ac k. The first c irc uit on the p roc essor interfac e c an b e c onnec ted d irec tly to the AUDIX throug h the PI c onnec tor on the rear of the c ontrol c arrier. Any of the remaining three c irc uits on the p roc essor interfac e to b e used to sup p ort AUDIX must b e c onnec ted throug h a 7400D Data Mod ule serving as the interfac e link for AUDIX. The option setting s are shown in Ta b l e A - 6 . Table A-6. Data Module Settings for DEFINITY AUDIX DIP Switch 1 Setting 9600 ON SYN C O N INT ON AANS ON All Other Switc hes OFF
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Option Switch Settings A-12 TN760D Tie Trunk Circuit Pack Option Settings A TN760D Tie Trunk Circuit Pack Option Settings The TN760D Tie Trunk c irc uit p ac k interfac es b etween the tie trunks and the Time Division Multip lex (TDM) b us. Two tip and ring p airs form a 4-wire analog transmission line. An E and M pair is used for signaling and are DC signaling lead s used for c all setup . The E lead rec eives sig nals from the tie trunk and the M lead transmits sig nals to the tie trunk. To c hoose the preferred sig naling format (Ta b l e A - 7 and Ta b l e A - 8), set the switc hes on the TN760D and ad minister the p ort per Fi g u re A - 3 and Ta b l e A - 9. !CAUTION: To p revent d amag e from static elec tric ity, wear an EMC wrist strap (c omc od e 900698226) when hand ling c irc uit p ac ks or other c omp onents. Table A-7. Signaling Formats for TN760D Mode Type E & M Typ e I Stand ard (unp rotec ted ) E & M Typ e I Comp atib le (unp rotec ted ) Protected Type I Compatible, Type I Standard Sim p l e x Typ e V E & M Typ e V E & M Typ e V Revised Table A-8. Signaling Type Summary Signaling Transmit (M-Lead) Receive (E-Lead) Type On-Hook Off-Hook On-Hook Off-Hook Type I Standard grd bat open 1/b at 1. An op en c irc uit is p referred instead of b attery voltag e.grd Type I Compatible open 1/b at g rd g rd op en1/b at Type V open 1/bat grd open grd Type V Reversed grd open grd open
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Option Switch Settings A-13 TN760D Tie Trunk Circuit Pack Option Settings A Figure A-3. TN760D Tie Trunk Circuit Pack (Component Side) 4321 PORT 4 PORT 3 PORT 2PORT 1 UNPROT PROTSMPLX E&MSMPLX E&MSMPLX E&MSMPLX E&M r758183RBP050896
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Option Switch Settings A-14 TN760D Tie Trunk Circuit Pack Option Settings A Table A-9. TN760D Option Switch Settings and Administration Installation SituationSet Prot/ Unprot Option Switch Preferred Signaling FormatSet E&M/SMPLX Option SwitchAdministered Port Circumstance To System Far-End Co-Loc ated Sys75/G1 Simp lex Simp lex SMPLX Either Typ e 5 Typ e 5 Typ e 5 Inter-Build ing Sys75/G1 Simp lex Simp lex SMPLX Either Typ e 5 Typ e 5 Typ e 5 Co-Loc ated Sys85/G2 Simp lex Simp lex SMPLX Either Typ e 5 Typ e 5 Typ e 5 Inter-Build ing Sys85/G2 Simp lex Simp lex SMPLX Either Typ e 5 Typ e 5 Typ e 5 Co-Loc ated DIMENSION E&M Typ e 1 E&M Typ e 1 E&M Unp rotec ted Typ e 1 PBX Comp atible Stand ard Compatible Inter-Build ing DIMENSION Protec ted Ty p e 1Protec ted Typ e 1E&M Pro te c t e d Typ e 1 PBX Comp atible Stand ard Compatible Co-Loc ated Other E&M Typ e 1 E&M Typ e 1 E&M Unp rotec ted Typ e 1 Comp atible Stand ard Compatible Inter-Build ing Other Protec ted Ty p e 1Protec ted Typ e 1E&M Pro te c t e d Typ e 1 Comp atible Stand ard Pl u sCompatible Protec tion Unit Co-Loc ated Net Integ ratedE&M Typ e 1 Any PBX E&M Unp rotec ted Typ e 1 Stand ard
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Option Switch Settings A-15 TN464/2464 Option Settings A TN464/2464 Option Settings The TN464/2464 DS1/E1 Interfac e-T1/E1 c irc uit p ac k interfac es b etween a 24 or 32 c hannel CO/ISDN or tie trunk and the Time Division Multip lexing (TDM) b us. Set the switc hes on the c irc uit p ac k to selec t b it rate and imp edanc e matc h. See Ta b l e A - 1 0 and Fi g u re A - 4. Figure A-4. TN464/2464 Option Settings Table A-10. Option Switch Settings on TN464/2464 120 Ohms Twisted pair 75 Ohms Coaxial req uiring 888A ad ap ter 32 Channel 2.048 Mb p s 24 Channel 1.544 Mb p s 3 8 4 9 5 10 1 6 2 7 1. Bac kp lane Connec tors 2. 24/32 Channel Selec tor 3. 75/120 ohm Selec tor 4. Fac ep late 5. 32 Channel6. 120 ohm (shown selec ted ) 7. 24 Channel (shown selec ted ) 8. 75 ohm 9. Connec tor 10. TN464/2464 Figure Notes:
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Option Switch Settings A-16 TN464/2464 Option Settings A
Connecting and Handling Fiber Optic Cables B-1 LASER Product B DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 B Connecting and Handling Fiber Optic Cables Sig nals b etween the c ab inets c omp osing the system are c arried by fib er op tic c ab les. To ac c omp lish this, the elec tronic signals at the c onnec tors on the b ac k of a c ab inet must b e c onverted into op tic al sig nals and op tic al sig nals from another c ab inet must b e c onverted b ac k into elec tronic sig nals. Op to-elec tronic d evic es (lig htwave transc eivers) p rovid e this interfac e. LASER Product The DEFINITY ECS may c ontain a Class 1 LASER devic e if sing le-mod e fib er op tic c ab le is c onnec ted to a remote Exp ansion Port Network (EPN). The LASER d evic e op erates within the following p arameters: nPower Output: -5 d Bm nWaveleng th: 1310 nm nMod e Field Diameter: 8.8 µm nCLASS 1 LASER PRODUCT nIEC 825 1993 !CAUTION: Use of c ontrols or ad justments or p erformanc e of p roc ed ures other than those specified herein may result in hazardous radiation exp osure. Contac t your Luc ent Tec hnolog ies rep resentative for more information.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Connecting and Handling Fiber Optic Cables B-2 Optical Cross-Connect Hardware B Optical Cross-Connect Hardware Optic al c ross-c onnec ts c onsist of Lightg uide Interc onnec t Units (LIUs) with lig htg uid e troug hs in b etween them. Fi g u re B - 1 shows a typ ic al LIU. One LIU terminates the inc oming c ab les and the other terminates the outg oing c ab les. A fib er op tic p atc h c ord or jump er is used to c onnec t the c irc uits. Circ uits c an b e rerouted the same as on 110-typ e c onnec ting b loc ks, by moving the p atc h c ord from one p oint on the Main Distrib ution Frame (MDF) to another. Figure B-1. Typical Optical Lightguide Interconnect Unit 1. 100A Lig htguide Interc onnect Unit (LIU) 2. Multi-Mod e Connec tor (C2000A-2) Sing le-Mod e Connec tor (C3000A-2) 3. Ad hesive-Bac ked Circuit Labels4. 1A4 Lig htg uid e Troug h 5. Fib er Patc h Cord 6. 1A6 Lig htg uid e Troug h 7.Op en Lig htg uid e Interc onnec t Unit (LIU) Figure Notes:
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Connecting and Handling Fiber Optic Cables B-3 Optical Cross-Connect Hardware B Optic al interc onnec ts c onsist of Lig htg uid e Interc onnec t Units (LIUs) without a troug h b etween them. Fi g u re B - 2 shows a typ ic al Interc onnec t field. Inc oming and outg oing multi-mod e and sing le-mode c ab les are c onnec ted d irec tly to eac h other. This arrang ement makes c irc uit c hang es more d iffic ult, b ut red uc es op tic al losses. Figure B-2. Typical Optical Interconnect Field Optic al c ross-c onnec t and interc onnec t field s are made up of the following: n100A Lig htguid e Interc onnec t Unit (LIU) n10A Lig htg uid e Connec tor Panel nC2000A-2 Connec tor Coup ling (Multi-Mod e) or C3000A-2 Connec tor Coupling (Single-Mode) n1A4 Lig htg uid e Troug h n1A6 Lig htg uid e Troug h nMulti-Mod e or Sing le-Mod e Fiber Interc onnec t Cab le 1. 100A Lig htg uid e Interc onnec t Unit (LIU) 2. Op en Lig htg uid e Interc onnec t Unit (LIU) Door3. C2000A-2 Connec tor (Multi-Mod e) C3000A-2 Connec tor (Single-Mode) 4. Labels Figure Notes:
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Connecting and Handling Fiber Optic Cables B-4 Optical Cross-Connect Hardware B 100A Lightguide Interconnect Unit The 100A Lig htg uid e Interc onnec t Unit (LIU) (c omc od e 104141841) c onsists of a c ab inet with retainer ring s to hold slac k fib er c ab les, mounting c utouts for two 10A lightg uid e c onnec tor p anels, and a d oor with c irc uit lab els on eac h sid e. See Fi g u re B - 3 . Figure B-3. 100A Lightguide Interconnection Unit 1. 100A Lig htg uid e Interc onnec t Unit (LIU)2. Retainer Ring s 3. Circ uit Lab els Figure Notes: