    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-11 Call Detail Recording Option Settings 
    A
    Call Detail Recording Option Settings
    The interfac e between the system and  Call Detail Rec ord ing  (CDR) equip ment 
    may b e one of the following :
    nData Module — Rec ommend ed  op tion setting s are shown in Ta b l e  A - 3.
    nMod em — Rec ommend ed  option setting s are in mod em vend or 
    document
    nTN726 Data Line c irc uit p ac k and  an Async hronous Data Unit — Data 
    mod ules or mod ems are not req uired .
    nConnec ted  d irec tly to the DCE
     connector (Electronic Industries 
    Assoc iation (EIA) Port) loc ated  on the rear of the Control Carrier 
    — data 
    mod ules or mod ems are not req uired .
    A 572 Printer c an be used  as an outp ut rec eiving  d evic e for Call Detail Rec ord ing  
    (CDR). The rec ommend ed  option setting s for this p rinter are shown in the 
    f o l lo w in g  t a b le s.  Al so ,  a  TEL ESEER,  C a ll  D e t a il  Re c o rd in g  ( C D R) ,  9 4 A L o c a l 
    Storag e Unit (LSU), or Customer Premises Eq uip ment (CPE) c an b e used  as the 
    output receiving  d evice.
    Ad ministration p roc ed ures for Call Detail Rec ord ing  (CDR) eq uip ment are 
    p rovid ed in 
    DEFINITY Enterp rise Communic ations Server Release 8 
    Ad ministration and  Feature Desc ription
    .
    AUDIX Interface Option Settings
    The Aud io Information Exc hang e (AUDIX) is sometimes c onnec ted  to the system 
    throug h the TN765 Proc essor Interfac e c irc uit p ac k. The first c irc uit on the 
    p roc essor interfac e c an b e c onnec ted  d irec tly to the AUDIX throug h the PI
     
    c onnec tor on the rear of the c ontrol c arrier.
    Any of the remaining  three c irc uits on the p roc essor interfac e to b e used  to 
    sup p ort AUDIX must b e c onnec ted  throug h a 7400D Data Mod ule serving  as the 
    interfac e link for AUDIX. The option setting s are shown in Ta b l e  A - 6
    .
    Table A-6. Data Module Settings for DEFINITY AUDIX
    DIP Switch 1 Setting
    9600 ON
    SYN C O N
    INT ON
    AANS ON
    All Other Switc hes OFF 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-12 TN760D Tie Trunk Circuit Pack Option Settings 
    A
    TN760D Tie Trunk Circuit Pack Option 
    Settings
    The TN760D Tie Trunk c irc uit p ac k interfac es b etween the tie trunks and  the Time 
    Division Multip lex (TDM) b us. Two tip  and ring  p airs form a 4-wire analog  
    transmission line. An E and M pair is used for signaling and are DC signaling 
    lead s used  for c all setup . The E lead  rec eives sig nals from the tie trunk and the M 
    lead  transmits sig nals to the tie trunk. 
    To c hoose the preferred  sig naling  format (Ta b l e  A - 7
     and Ta b l e  A - 8), set the 
    switc hes on the TN760D and  ad minister the p ort per Fi g u re  A - 3
     and  Ta b l e  A - 9.
    !CAUTION:
    To p revent d amag e from static  elec tric ity, wear an EMC wrist strap  
    (c omc od e 900698226) when hand ling  c irc uit p ac ks or other c omp onents.
    Table A-7. Signaling Formats for TN760D
    Mode Type
    E & M Typ e I Stand ard  (unp rotec ted )
    E & M Typ e I Comp atib le (unp rotec ted )
    Protected Type I Compatible, Type I Standard
    Sim p l e x Typ e  V
    E & M Typ e  V
    E & M Typ e V Revised
    Table A-8. Signaling Type Summary
    Signaling Transmit (M-Lead) Receive (E-Lead)
    Type On-Hook Off-Hook On-Hook Off-Hook
    Type I Standard grd bat open
    1/b at
    1. An op en c irc uit is p referred  instead  of b attery voltag e.grd
    Type I Compatible open
    1/b at g rd g rd op en1/b at
    Type V open
    1/bat grd open grd
    Type V Reversed grd open grd open 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-13 TN760D Tie Trunk Circuit Pack Option Settings 
    A
    Figure A-3. TN760D Tie Trunk Circuit Pack (Component Side)
    4321
    PORT 4 PORT 3 PORT 2PORT 1 UNPROT
    PROTSMPLX
    E&MSMPLX
    E&MSMPLX
    E&MSMPLX
    E&M
    r758183RBP050896 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-14 TN760D Tie Trunk Circuit Pack Option Settings 
    A
    Table A-9. TN760D Option Switch Settings and Administration
    Installation
    SituationSet
    Prot/
    Unprot
    Option
    Switch Preferred
    Signaling FormatSet 
    E&M/SMPLX
    Option
    SwitchAdministered
    Port Circumstance To System Far-End
    Co-Loc ated Sys75/G1 Simp lex Simp lex SMPLX Either Typ e 5
    Typ e 5 Typ e 5
    Inter-Build ing Sys75/G1 Simp lex Simp lex SMPLX Either Typ e 5
    Typ e 5 Typ e 5
    Co-Loc ated Sys85/G2 Simp lex Simp lex SMPLX Either Typ e 5
    Typ e 5 Typ e 5
    Inter-Build ing Sys85/G2 Simp lex Simp lex SMPLX Either Typ e 5
    Typ e 5 Typ e 5
    Co-Loc ated DIMENSION E&M Typ e 1 E&M Typ e 1 E&M Unp rotec ted Typ e 1
    PBX Comp atible Stand ard Compatible
    Inter-Build ing DIMENSION Protec ted  
    Ty p e  1Protec ted 
    Typ e 1E&M Pro te c t e d Typ e  1
    PBX Comp atible Stand ard Compatible
    Co-Loc ated Other E&M Typ e 1 E&M Typ e 1 E&M Unp rotec ted Typ e 1
    Comp atible Stand ard Compatible
    Inter-Build ing Other Protec ted  
    Ty p e  1Protec ted 
    Typ e 1E&M Pro te c t e d Typ e  1
    Comp atible Stand ard 
    Pl u sCompatible
    Protec tion
    Unit
    Co-Loc ated Net 
    Integ ratedE&M Typ e 1 Any PBX E&M Unp rotec ted Typ e 1
    Stand ard 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-15 TN464/2464 Option Settings 
    A
    TN464/2464 Option Settings
    The TN464/2464 DS1/E1 Interfac e-T1/E1 c irc uit p ac k interfac es b etween a 24 or 
    32 c hannel CO/ISDN or tie trunk and  the Time Division Multip lexing  (TDM) b us.
    Set the switc hes on the c irc uit p ac k to selec t b it rate and imp edanc e matc h. See 
    Ta b l e  A - 1 0
     and  Fi g u re  A - 4.
    Figure A-4. TN464/2464 Option Settings
    Table A-10. Option Switch Settings on TN464/2464
    120 Ohms Twisted pair
    75 Ohms Coaxial req uiring  888A ad ap ter
    32 Channel 2.048 Mb p s
    24 Channel 1.544 Mb p s
    3
    8
    4
    9
    5
    10
    1
    6
    2
    7
    1. Bac kp lane Connec tors
    2. 24/32 Channel Selec tor
    3. 75/120 ohm Selec tor
    4. Fac ep late
    5. 32 Channel6. 120 ohm (shown selec ted )
    7. 24 Channel (shown selec ted )
    8. 75 ohm
    9. Connec tor
    10. TN464/2464
    Figure Notes: 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-16 TN464/2464 Option Settings 
    A 
    						
    							Connecting and Handling Fiber Optic Cables 
    B-1 LASER Product 
    B
    DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    B
    Connecting and Handling Fiber 
    Optic Cables
    Sig nals b etween the c ab inets c omp osing  the system are c arried  by fib er op tic  
    c ab les. To ac c omp lish this, the elec tronic  signals at the c onnec tors on the b ac k 
    of a c ab inet must b e c onverted  into op tic al sig nals and op tic al sig nals from 
    another c ab inet must b e c onverted  b ac k into elec tronic  sig nals. Op to-elec tronic  
    d evic es (lig htwave transc eivers) p rovid e this interfac e.
    LASER Product
    The DEFINITY ECS may c ontain a Class 1 LASER devic e if sing le-mod e fib er 
    op tic  c ab le is c onnec ted  to a remote Exp ansion Port Network (EPN). The LASER 
    d evic e op erates within the following  p arameters:
    nPower Output: -5 d Bm
    nWaveleng th: 1310 nm
    nMod e Field  Diameter: 8.8 µm
    nCLASS 1 LASER PRODUCT
    nIEC 825 1993
    !CAUTION:
    Use of c ontrols or ad justments or p erformanc e of p roc ed ures other 
    than those specified herein may result in hazardous radiation 
    exp osure.
    Contac t your Luc ent Tec hnolog ies rep resentative for more information. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Connecting and Handling Fiber Optic Cables 
    B-2 Optical Cross-Connect Hardware 
    B
    Optical Cross-Connect Hardware
    Optic al c ross-c onnec ts c onsist of Lightg uide Interc onnec t Units (LIUs) with 
    lig htg uid e troug hs in b etween them. Fi g u re  B - 1
     shows a typ ic al LIU. One LIU 
    terminates the inc oming  c ab les and the other terminates the outg oing  c ab les. A 
    fib er op tic  p atc h c ord  or jump er is used  to c onnec t the c irc uits. Circ uits c an b e 
    rerouted  the same as on 110-typ e c onnec ting  b loc ks, by moving  the p atc h c ord  
    from one p oint on the Main Distrib ution Frame (MDF) to another.
    Figure B-1. Typical Optical Lightguide Interconnect Unit
    1. 100A Lig htguide Interc onnect Unit 
    (LIU)
    2. Multi-Mod e Connec tor (C2000A-2)
    Sing le-Mod e Connec tor (C3000A-2)
    3. Ad hesive-Bac ked  Circuit Labels4. 1A4 Lig htg uid e Troug h
    5. Fib er Patc h Cord
    6. 1A6 Lig htg uid e Troug h
    7.Op en Lig htg uid e Interc onnec t Unit 
    (LIU) 
    Figure Notes: 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Connecting and Handling Fiber Optic Cables 
    B-3 Optical Cross-Connect Hardware 
    B
    Optic al interc onnec ts c onsist of Lig htg uid e Interc onnec t Units (LIUs) without a 
    troug h b etween them. Fi g u re  B - 2
     shows a typ ic al Interc onnec t field. Inc oming  
    and  outg oing  multi-mod e and  sing le-mode c ab les are c onnec ted  d irec tly to eac h 
    other. This arrang ement makes c irc uit c hang es more d iffic ult, b ut red uc es op tic al 
    losses.
    Figure B-2. Typical Optical Interconnect Field
    Optic al c ross-c onnec t and  interc onnec t field s are made up  of the following:
    n100A Lig htguid e Interc onnec t Unit (LIU)
    n10A Lig htg uid e Connec tor Panel
    nC2000A-2 Connec tor Coup ling  (Multi-Mod e) or C3000A-2 Connec tor 
    Coupling (Single-Mode)
    n1A4 Lig htg uid e Troug h
    n1A6 Lig htg uid e Troug h
    nMulti-Mod e or Sing le-Mod e Fiber Interc onnec t Cab le
    1. 100A Lig htg uid e Interc onnec t Unit 
    (LIU)
    2. Op en Lig htg uid e Interc onnec t Unit 
    (LIU) Door3. C2000A-2 Connec tor (Multi-Mod e)
    C3000A-2 Connec tor 
    (Single-Mode)
    4. Labels
    Figure Notes: 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Connecting and Handling Fiber Optic Cables 
    B-4 Optical Cross-Connect Hardware 
    B
    100A Lightguide Interconnect Unit
    The 100A Lig htg uid e Interc onnec t Unit (LIU) (c omc od e 104141841) c onsists of a 
    c ab inet with retainer ring s to hold  slac k fib er c ab les, mounting  c utouts for two 
    10A lightg uid e c onnec tor p anels, and a d oor with c irc uit lab els on eac h sid e. See 
    Fi g u re  B - 3
    .
    Figure B-3. 100A Lightguide Interconnection Unit
    1. 100A Lig htg uid e Interc onnec t 
    Unit (LIU)2. Retainer Ring s
    3. Circ uit Lab els
    Figure Notes: 
    						
    All Lucent Technologies manuals Comments (0)