Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-19 Administer the System 3 Set Country Options Certain c ountry options need to b e set to turn red failure ind ic ation LEDs off. Refer to Ta b l e 3 - 5 for a list of c ountry c od es. 1. Verify the sc reen d isp lays command: 2. Type change system-parameters country options and press En te r. A sc reen similar to Sc reen 3-3 is d isp layed . The c ursor is set on the Companding Mode line. Screen 3-3. Typical System Parameters Country-Options Screen
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-20 Administer the System 3 3. The d efault c omp and ing mode is mu-Law. If the c ountry uses A-Law c omp and ing , typ e A-Law. Press En te r when this information is c orrec t. Other items eventually need to b e entered on this sc reen, b ut this is all that must b e d one to turn the red alarm LEDs off. 4. If all red LEDs d o not g o off, reseat (unp lug and reinsert) any port circuit p acks d isp laying red LEDs. !CAUTION: To avoid a disk c rash, never reseat the DEFINITY AUDIX System without first shutting it d own. Shut d own the DEFINITY AUDIX System (and allow the d isk to c omp letely spin d own) b efore unp lugg ing the assemb ly. See ‘‘ D EFI N I TY A U D I X Sy st e m Po w e r Pro c e d u re s’’ o n page 3-33 for the p rop er p roc ed ures. 5. If the red LEDs still d o not g o off, refer to D EFI N I TY En t e rp r i se Communic ations Server Release 8 Maintenanc e for R8si . NOTE: Ig nore the red alarm ind ic ation LED on the TN767 or TN464/2464 DS1 c irc uit p ac k until after the DS1 c irc uit p ac k is ad ministered . Alarms will ap p ear in the Alarm Log when p ower is ap p lied to the system b efore all eq uip ment c onnec ting to port c irc uit p ac ks is installed . Normally, some alarms will b e log g ed when p ower is ap p lied to the system, b ut should b e resolved q uic kly. If no eq uip ment is c onnec ted to the p ort c irc uit p ac ks, alarms assoc iated with these p orts c an take up to four hours to log , b ut will c lear automatic ally after all equip ment is installed and op erating c orrec tly. Table 3-5. Country Codes Country Code Country Code USA 1 France 12 Australia 2 Germany 13 Jap an 3 Czec hoslovakia 14 Italy 4 Russia 15 Netherland s 5 Argentina 16 Sing ap ore 6 Greec e 17 Mexic o 7 China 18 Belg ium 8 Hong Kong 19 Saud i Arabia 9 Thailand 20 United King d om 10 Maced onia 21 Sp a i n 1 1
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-21 Administer the System 3 Change Craft Password The p assword for the c raft log in must be changed b y the installing tec hnic ian to p revent unauthorized ad ministration c hang es. !CAUTION: After the password is changed, the new password must be safeguarded so no unauthorized ad ministration c hang es c an b e mad e. This p assword M U ST N O T B E REVEAL ED t o t h e c u s t o m e r o r t o a n y u n a u t h o r iz e d p e r s o n . Passwords are changed using the Change Password Screen. See Sc reen 3-4. 1. Verify the sc reen d isp lays command: 2. Type change password craft. Press En t e r . Screen 3-4. Typical Change Password Screen 3. Verify the sc reen d isp lays the Chang e Password Sc reen. The c ursor is p ositioned on Password for Login Making Change: ” 4. Typ e the p assword assig ned to the c raft log in (assig ned as c rftp w when system is shipped) and press En t e r. The c ursor is p ositioned on Login’s Password :.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-22 Administer the System 3 5. Enter new p assword . Valid p assword s c onsist of a c omb ination of from four to eleven alp ha or numeric c harac ters. At least one letter and one numb er must be used in eac h password . 6. Press En te r. The c ursor is p ositioned on Reenter Login’s Password :. 7. Type new password again and press EN TER. 8. Verify the sc reen d isp lays: command successfully completed command : Set Daylight Savings Rules You c an set up to 15 c ustomized d aylig ht saving s time rules. If you have switc hes in several d ifferent time zones, you c an set up rules for eac h. A d aylig ht saving s time rule sp ec ifies the exac t time when you want to transition to and from daylig ht saving s time. It also spec ifies the inc rement at whic h to transition. NOTE: The d efault d aylig ht saving s rule is 0 , no d aylig ht saving s. 1. Type change daylight-savings-rules and press En t e r. 2. Type the appropriate start and stop information in the Change Day , Month , Date , Time , and Increment (for example, 1:00 eq uals one hour) field s for eac h rule. NOTE: You c an c hang e any rule exc ep t rule 0 (zero). You c annot delete a d aylig ht saving s rule if it is in use on either the Loc ations or Date and Ti m e s c re e n s . 3. Press En t e r. DAYLIGHT SAVINGS RULES Rule Change Day Month___Date Time____Increment 0: No Daylight Savings 1: Start: first Sunday ___ on or after April___ 1 at _2:00 01:00Stop: first Sunday___ on or after October_ 25 at _2:002: Start: first _________ on or after ________ __ at __: : Stop: first _________ on or after ________ __ at __:__ 3: Start: first _________ on or after ________ __ at __: : Stop: first _________ on or after ________ __ at __:__ 4: Start: first _________ on or after ________ __ at __: : Stop: first _________ on or after ________ __ at __:__ 5: Start: first _________ on or after ________ __ at __: : Stop: first _________ on or after ________ __ at __:__ 6: Start: first _________ on or after ________ __ at __: : Stop: first _________ on or after ________ __ at __:__ 7: Start: first _________ on or after ________ __ at __: : Stop: first _________ on or after ________ __ at __:__
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-23 Administer the System 3 Set Date and Time 1. Type set time and press En t e r. . Screen 3-5. Typical Date and Time Screen 2. Typ e the d ay of the week in Eng lish (Sunday throug h Saturd ay) and press TA B to move to next field . See Tab le 3-6 for Eng lish day of the week names. 3. The c ursor is p ositioned on the Month: field . Typ e the c urrent month in Eng lish (January throug h Dec emb er). See Tab le 3-7 for English month names. After the month is entered, p ress TA B to move to next field . Table 3-6. English Day of the Week Names Day Number Day Name 1Sunday 2 Mond ay 3Tuesday 4 Wed nesd ay 5Thursday 6Friday 7Saturday DATE AND TIME DATE Day of the Week: Tuesday Month: FebruaryDay of the Month: 8 Year: 2000 TIME Hour: 20 Minute: 30Second: XX Type: standardDaylight Savings Rule: 0
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-24 Administer the System 3 4. The c ursor is p ositioned on the Day of the Month: field . Typ e the d ay of month (1 through 31) and p ress TA B to move to the next field . 5. The c ursor is p ositioned on the Year: field . Typ e the c urrent year and p ress Ta b to move to the next field . 6. The c ursor is p ositioned on the Hour: field . Typ e the c urrent hour for a 24-hour c loc k. See Ta b l e 3 - 8 . Press Ta b to move to the next field . 7. The c ursor is p ositioned on the Minute: field . Type c urrent minute (0 throug h 59). Sec ond s c annot b e set. 8. Type standard or daylight savings in the Type field . 9. Typ e the rule (numb er) in the Daylight Savings Rule field. 10. Press En t e r when the information is c orrec t. Table 3-7. English Month Names Month Number Month Name 1 January 2February 3March 4April 5May 6 June 7July 8 Aug ust 9 Sep temb er 10 Oc tob er 11 Novemb er 12 Dec ember
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-25 Administer the System 3 11. Verify the sc reen d isp lays: command successfully completed command: 12. Typ e display time , and p ress En t e r to verify d ate/time d ata. Table 3-8. Conversion to 24-Hour Clock Standard Time Standard Time 12-Hour 24-Hour 12-Hour 24-Hour 12:00 mid nig ht0000 12:00 noon1200 1:00 am 0100 1:00 p m 1300 2:00 am 0200 2:00 p m 1400 3:00 am 0300 3:00 p m 1500 4:00 am 0400 4:00 p m 1600 5:00 am 0500 5:00 p m 1700 6:00 am 0600 6:00 p m 1800 7:00 am 0700 7:00 p m 1900 8:00 am 0800 8:00 p m 2000 9:00 am 0900 9:00 p m 2100 10:00 am 1000 10:00 p m 2200 11:00 am 1100 11:00 p m 2300
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-26 Administer the Circuit Packs 3 Administer the Circuit Packs After the eq uip ment is installed (inc lud ing c irc uit p ac ks), the c irc uit pac ks must b e ad ministered . Refer to DEFINITY Enterp rise Communic ations Server Release 8 Ad ministration and Feature Desc rip tion for more information. The following information d esc ribes general ad ministration information: nUse the Circ uit Pac ks form to ad minister c irc uit p ac ks to c arrier slots. The c irc uit p ac ks must b e installed (or assig ned using the Circ uit Pac ks form) before administering voice terminals, attendant consoles, or trunks. nEac h p ag e of the form rep resents one c arrier in the c ab inet shown on the c ommand line. All c arriers and slots ap p ear even if they are not inc lud ed in the hardware. nIt is not nec essary to fill in the Circ uit Pac ks form if the c irc uit p ac ks are installed at the time of ad ministration. nRefer to DEFINITY Communic ations System Generic 3 Planning and Config uration , 555-230-601, for more information ab out c irc uit pac k ad ministration and port assig nment rec ord s. nFor initial installation, assig n c irc uit p ac ks to slots using the hard ware configuration layout record from the fac tory or Customer Services Org anization. Do not arb itrarily assig n c irc uit p ac ks to slots. nWhen a c irc uit p ac k in a slot d iffers from what has b een ad ministered on the form, a “ #” d isp lays b etween the “ Sfx” and “ Name” field s. nAll slot field s are d isp layed . Administration Commands Use the following ad ministration c ommand s to ad minister the Circ uit Pac k form. NOTE: If no cabinet number is specified, this command defaults to 1. Table 3-9. Administration Commands Action Object Qualifier 1 1.Brackets [ ] indicate the qualifier is optional. Single quotes (’ ’) indicate the text inside the quote must be entered exactly as shown or an abbreviated form of the word may be entered. xx is the cabinet number. c hang e c irc uit-p ac ks xx (c ab inet number) d isp lay circuit-p acksxx (c ab inet number) [ ’p rint’ or ’sc hed ule’]
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-27 Administer the Circuit Packs 3 Form Instructions Screen 3-6. Change Circuit-Packs Screen NOTE: Each page of the form represents 1 carrier within the cabinet specified on the command line. For R8si configurations, all carriers and slots appear even if they are not included in the actual hardware. This supports reconfiguration. nCabinet — Disp lay-only field . This field shows the c abinet numb er as entered on the c ommand line. nCarrier — Disp lay-only field . This field shows the letter of the c arrier (A throug h E) c irc uit p ac ks are b eing ad ministered on. nCarrier Type — Disp lay-only field . This field shows the typ e of c arrier. nSlot — Disp lay-only field . The slot eq uates to the physic al slot of the g iven c arrier; the numb er of slots d isp layed d ep end s on the system being configured. For R8si c onfig urations, ALL slots that c ould p ossib ly b e ad ministered are d isp layed even if they do not ap p ly to the c urrent c onfig uration of the system. This is to ac c ommod ate the situation when a system is b eing rec onfig ured . change circuit-packs Page 1 of 5 CIRCUIT PACKS Cabinet: 1 Carrier: A Carrier Type: processor Slot Code Sf Mode Name 01: TN758 POOLED MODEM 02: TN726 B DATA LINE 03: TN763 D AUXILIARY TRUNK 04: TN750 C ANNOUNCEMENT 05: TN2181 DIGITAL LINE 06: TN464 F DS1 INTERFACE 07: TN2138 CO TRUNK 08: TN754 B DIGITAL LINE 09: TN799 B CONTROL-LAN 10: TN767 D DS1 INTERFACE Slot Code Sf Mode Name Slot Code Sf Mode Name 11: TN464 F DS1 INTERFACE 01: TN758 POOLED MODEM 12: MEDPRO RESERVED-IP 02: TN726 B DATA LINE 13: TN802 B MAPD BOARD 03: TN763 D AUXILIARY TRUNK 14: TN2149 ANALOG LINE 04: TN750 C ANNOUNCEMENT 15: TN754 B DIGITAL LINE 05: TN2181 DIGITAL LINE 16: TN754 B DIGITAL LINE # indicates circuit pack conflict.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-28 Administer the Circuit Packs 3 Tab le 3-10 lists the slots to use, and the c irc uit p ac k typ es that may b e ad ministered in those slots, for eac h c omb ination of Cab inet/Carrier/Carrier Typ e in a R8si c onfig uration. nCode — Enter the c irc uit p ac k c od e (TN followed b y a 3- or 4-d ig it numb er). If there is a p hysic al c irc uit p ac k installed in the slot, the entry must matc h that of the c irc uit p ac k. If there is eq uip ment ad ministered on a slot, the eq uip ment must b e removed from the c irc uit p ac k b efore the c irc uit p ac k c an b e c hang ed or removed . nSfx — Enter the c irc uit pac k suffix, if ap p lic able. nName — Disp lay-only field. This field shows the alp hanumeric name of the c irc uit p ac k (suc h as Dig ital Line). NOTE: When the circuit pack physically inserted in the slot differs from what has been administered on this form, a # displays between the Sfx and Name fields. Implementation Notes Sc reen 3-6 shows all field s that may b e displayed . The field s that ap p ear on a p artic ular sc reen may vary d ep end ing up on the system c onfig uration b eing ad ministered . The number of slot fields displayed may vary depending on the system being config ured . For R8si configurations, all p ossib le slots d isp lay. Table 3-10. Circuit Pack Cabinet Layout Cabinet Layout Carrier TypeUse Slots Circuit Pack Types 1A (SCC Basic Control Cab inet) p roc essor 01-10 All port c irc uit p ac ks 1A (SCC Enhanc ed Control Cab inet) p roc essor 01-16 All port c irc uit p ac ks 1B (SCC Dup lic ated Control Cab inet) p roc essor 01-10 All port c irc uit p ac ks 1B, C, D (SCC Port Cab inet) p ort 01-18 All port c irc uit p ac ks 2A & 3A (SCC Exp ansion Control Cab inet)exp ansion-c ontrol 01 TN570, TN776 02-17 All p ort c irc uit p ac ks 2B, C, D (SCC Port Cab inet) 3B, C, Dp ort 01-18 All p ort c irc uit p ac ks