    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-143 Connector and Cable Diagrams (Pinout Charts) 
    5
    Table 5-41. Circuit Pack and Auxiliary Equipment Classifications.Analog
    Line (8)2-Wire 
    Digital 
    & 
    Analog
    Line (16)Data 
    Line & 
    Digital
    Line 
    4-Wire2-Wire 
    Digital 
    & 
    Analog
    Line (24) Hybrid
    LineMET
    LineAUX
    Tr u n kCentral 
    Office
    Tr u n kDID/
    DIOD
    Tr u n kTie
    Tr u n kDS1
    Tie
    TrunkISDN
    BRI
    Line 
    4-wirePacket 
    Data 
    Line Central
    Office
    Tr u n k
    3-WireISDN
    BRI
    Line 
    2-wireFour 
    Port 
    DIO
    D
    TN467 TN2149 TN726B TN2224 TN762 TN735 TN417 TN429 TN2199 TN429 TN478 TN483 TN556B TN2198 TN553 TN21
    8
    TN432 TN2135 TN754B TN2214 TN762B TN763 TN493 TN2139 TN458 TN722
    TN431 TN468B TN564B TN793 TN763D TN422 TN459B TN449 TN767
    TN411B TN448 TN413 TN2793 TN421 TN436B TN760
    DTN722B
    TN742 TN746 TN2214B TN438B TN753 TN760
    CTN2464
    TN769 TN746B TN2224B TN447 TN2146 TN434
    TN2181 TN793B TN465C TN414 TN415
    TN2183 TN2793B TN747B
    TN2215 TN2138
    TN7921 TN2147C
    TN21481. DID means Direc t Inward  Dialing
    2. DIOD means Direc t Inward  Outward  Dialing
    3. MET means Multibutton Elec tronic  Telep hone 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-144 Connector and Cable Diagrams (Pinout Charts)
    5
    5Table 5-42. Circuit Pack and Auxiliary Equipment Leads (Pinout Charts)Color Connector
    Pin
    NumbersAnalog
    Line
    8 ports2-Wire
    Digital
    Line &
    Analog
    Line
    16 portsData 
    Line & 
    Digital
    Line
    4-wire2-Wire
    Digital
    Line &
    Analog
    Line
    24 PortsHybrid
    LineMET
    LineAUX
    TrunkCO
    Tr k .CO
    Tr u n k
    3-wireDID/
    DIOD
    Tr u n kTie
    Tr k .DS1
    Ti e
    Tr u n kISDN
    BRI
    Line
    4-wireISDN
    BRI
    Line
    2-wirePacket
    Data 
    LineFour 
    Port 
    DIOD
    W- B L 2 6 T1 T1 T1 V1 T1 T1 T1 T1 A 1 T1 T1 PXR1 T1 TXT1 T1
    B L-W 01 R1 R1 R1 V1R1 R1 R1 R1 B 1 R1 R1 PXT1 R1 TXR1 R1
    W- O 2 7 T2 TXT1 T2 C T1 TXT1 SZ 1 T1 1 TXT1 T2 PXT1
    O- W 02 R2 TXR1 R2 CR1 TXR1 SZ 11 R11 TXR1 R2 PXR1
    W-G 28 T3 PXT1 T3 P-1 PXT1 S1 E1 PXR2 T3 TXT2
    G- W 03 R3 PXR1 R3 P+ 1 PXR1 S11 C1 M1 PXT2 R3 TXR2
    W- B R 2 9 T2 T4 T4 V1 T2 T2 T2 T2 A 2 T2 T2 TXT2 T4 PXT2 T2
    B R-W 04 R2 R4 R4 V1R2 R2 R2 R2 B 2 R2 R2 TXR2 R4 PXR2 R2
    W-S 30 TXT2 T5 CT2 TXT2 SZ 2 T1 2 PXR3 T5 TXT3
    S- W 05 TXR2 R5 CR2 TXR2 SZ 12 R12 PXT3 R5 TXR3
    R-B L 31 PXT2 T6 P-2 PXT2 S2 E2 TXT3 T6 PXT3
    B L-R 06 PXR2 R6 P+ 2 PXR2 S12 C 2 M2 TXR3 R6 PXR3
    R-O32 T3 T7 V1T3T3T3 T3A3T3T3 PXR4T7TXT4T3
    O-R07 R3 R7 V1R3R3R3 R3B3R3R3 PXT4R7TXR4R3
    R- G 3 3 TXT3 T8 C T3 TXT3 SZ 3 T1 3 TXT4 T8 PXT4
    G- R 08 TXR3 R8 CR3 TXR3 SZ 13 R13 TXR4 R8 PXR4
    R-B R 34 T5 PXT3 T9 P-3 PXT3 S3 E3 PXR5 T9 TXT5
    B R-R 09 R5 PXR3 R9 P+ 3 PXR3 S13 C 3 M3 PXT5 R9 TXR5
    R- S 3 5 T4 T6 T1 0 V1 T4 T4 T4 T4 A 4 T4 T4 TXT5 T1 0 PXT5 T4
    S- R 10 R4 R6 R10 V1R4 R4 R4 R4 B 4 R4 R4 TXR5 R1 0 PXR5 R4
    BK-BL 36 T7 TXT4 T11 CT4 TXT4 SZ 4 T1 4 PXR6 T11 TXT6
    BL-BK 11 R7 TXR4 R11 CR4 TXR4 SZ14 R14 PXT6 R11 TXR6
    Continued on next page 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-145 Connector and Cable Diagrams (Pinout Charts)
    5
    B K -O 37 T8 PXT4 T12 P-4 PXT4 S4 E4 TXT6 T12 PXT6
    O- BK 12 R8 PXR4 R12 P+ 4 PXR4 S14 M4 TXR6 R1 2 PXR6
    B K - G 3 8 T5 T9 T1 3 V1 T5 T5 T5 PXR7 TXT7
    G- BK 13 R5 R9 R13 V1R5 R5 R5 PXT7 TXR7
    BK-BR 39 T10 TXT5 T14 CT4TXT7 PXT7
    B R-B K 14 R10 TXR5 R14 C R4TXR7 PXR7
    BK-S 40 T11 PXT5 T15 P-5PXR8 TXT8
    S-BK 15 R11 PXR5 R15 P+ 5PXT8 TXR8
    Y- B L 4 1 T6 T1 2 T1 6 V1 T6 T6 T6 TXT8 PXT8
    B L-Y 16 R6 R12 R16 V1R6 R6 R6 TXR8 PXR8
    Y- O 4 2 TXT6 T1 7 C T6PXR9 TXT9
    O-Y 17 TXR6 R17 CR6PXT9 TXR9
    Y- G 43 PXT6 T18 P-6TXT9 PXT9
    G- Y 18 PXR6 R18 P+ 6TXR9 PXR9
    Y-BR 44 T7 T19 V1T7 T7 T7 PXR10 TXT10
    B R-Y 19 R7 R19 V1R7 R7 R7 PXT1 0 TXR1 0
    Y- S 4 5 TXT7 T2 0 C T7TXT1 0 PXT1 0
    S- Y 2 0 TXR7 R2 0 C R7TXR1 0 PXR1 0
    V-BL 46 T13 PXT7 T21 P-7PXR1 1 TXT1 1
    BL-V 21 R13 PXR7 R21 P+ 7PXT1 1 TXR1 1
    V- O 4 7 T8 T1 4 T2 2 V1 T8 T8 T8 L I * TXT1 1 PXT1 1
    O-V 22 R8 R14 R22 V1R8 R8 R8 LI TXR11 PXR11
    V- G 4 8 T1 5 TXT8 T2 3 C T8 L O PXR1 2 TXT1 2Table 5-42. Circuit Pack and Auxiliary Equipment Leads (Pinout Charts)Color Connector
    Pin
    NumbersAnalog
    Line
    8 ports2-Wire
    Digital
    Line &
    Analog
    Line
    16 portsData 
    Line & 
    Digital
    Line
    4-wire2-Wire
    Digital
    Line &
    Analog
    Line
    24 PortsHybrid
    LineMET
    LineAUX
    TrunkCO
    Tr k .CO
    Tr u n k
    3-wireDID/
    DIOD
    Tr u n kTie
    Tr k .DS1
    Ti e
    Tr u n kISDN
    BRI
    Line
    4-wireISDN
    BRI
    Line
    2-wirePacket
    Data 
    LineFour 
    Port 
    DIOD
    Continued on next page 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-146 Connector and Cable Diagrams (Pinout Charts)
    5
    †The wire colors in this chart apply only to B25A and A25B c ables. H600-307 c able c olors are not shown.
    The following  ab breviations ap p ly for all circuit p ac ks unless otherwise noted:
    T,R PBX transmit voic e  T Tip  (A) Green
    T1,R1 PBX rec eive voice  R Ring  (B) Red
    M PBX transmit signal  S Sleeve
    E PBX r ec ei v e s ig n al  PX PBX t ra ns m i t
    TX Te r m i n a l  t r a n sm i t
    LI, LI* Dig ital Trunk IN LO, LO* Digital Trunk OUT
    The following  wire c olors app ly in the ab ove chart:
    W White S Slate (Grey)
    BL Blue R Red
    OOrange BK Black
    G Green Y Yellow
    BRBrown V VioletG-V 23 R15 TXR8 R23 C R8 LO* PXT12 TXR1 2
    V- B R 4 9 T1 6 PXT8 T2 4 P- 8 L B A C K2 TXT1 2 PXT1 2
    B R- V 24 R16 PXR8 R24 P+ 8 LB A C K1 TXR1 2 PXR12
    V- S 5 0
    S- V 2 5Table 5-42. Circuit Pack and Auxiliary Equipment Leads (Pinout Charts)Color Connector
    Pin
    NumbersAnalog
    Line
    8 ports2-Wire
    Digital
    Line &
    Analog
    Line
    16 portsData 
    Line & 
    Digital
    Line
    4-wire2-Wire
    Digital
    Line &
    Analog
    Line
    24 PortsHybrid
    LineMET
    LineAUX
    TrunkCO
    Tr k .CO
    Tr u n k
    3-wireDID/
    DIOD
    Tr u n kTi e
    Tr k .DS1
    Ti e
    Tr u n kISDN
    BRI
    Line
    4-wireISDN
    BRI
    Line
    2-wirePacket
    Data 
    LineFour 
    Port 
    DIOD
    Continued on next page 
    						
    							Test Telephones and Other Equipment 
    6-1  
    6
    DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    6
    Test Telephones and Other 
    Equipment
    This c hapter d esc rib es how to test the telep hones and  other eq uip ment. The 
    following tests must be performed:
    1. Make test calls
    2. Test 302C Attend ant Console
    3. Test Selector Console
    4. Test External Ring ing
    5. Test Queue Warning Indicator
    6. Test Integ rated  Announc ement
    7. Test Music-on-Hold
    8. Test Emerg ency Transfer
    9. Test Remote Ac c ess Interfac e (INADS)
    10. Test Basic  Rate Interfac e (BRI)
    NOTE:
    The tests in this c hap ter are p erformed  after the eq uip ment has b een 
    wired  to the system and  after the c ustomer’s data for that eq uip ment 
    has been ad ministered .
    The following tests are ac c ep tanc e tests or sanity tests and  p rovid e some 
    assuranc e the system will p erform p rop erly after installation and  ad ministration. If 
    p rob lems oc c ur or more extensive or sp ec ific  tests are req uired, refer to 
    DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8si. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Test Telephones and Other Equipment 
    6-2 Make Test Calls 
    6
    Make Test Calls 
    Make two c alls from one telep hone to another telep hone. Make the first c all b y 
    d ialing  a telephone and  make the sec ond  c all b y dialing a trunk ac c ess c od e 
    and  a Listed  Direc tory Numb er (LDN).
    Test 302C Attendant Console
    Chec k all lamp s are op erational and  c all another telep hone in the system.
    1. Simultaneously p ress and  hold  the Ringer Volume up button
     and  the 
    POS BUSY button
    . This p uts the c onsole in the self-test mod e.
    NOTE:
    Releasing the buttons c auses the c onsole to return to normal mod e.
    2. Verify all lamp s on d isp lay lig ht and  remain lighted . Eac h row of lamp s on 
    the c onsole lights and  g oes d ark in seq uenc e from top to b ottom.
    3. Press Start
    . 
    Listen for d ial tone.
    The g reen lamp  assoc iated  with idle c all ap p earanc e b utton lig hts.
    Th e  Position Available 
    lamp g oes d ark.
    4. Dial numb er assoc iated  with a working  telep hone. Aud ib le ring ing  tone is 
    heard  in ear p iec e.
    5. Press Release
    . 
    Aud ib le ring ing  tone is silenc ed.
    The g reen lamp  assoc iated  with idle c all ap p earanc e b utton g oes dark.
    Th e  Position Available
     lamp lig hts.
    Test Selector Console
    Chec k all selec tor c onsole lamp s are op erational. Make c all to a telep hone in the 
    system.
    1. Simultaneously p ress and  hold  the Ringer Volume up button
     and  the 
    POS BUSY button
    . This p uts the c onsole in the self-test mod e.
    2. Eac h row of lamp s on the selec tor c onsole lig hts and  g oes d ark in 
    seq uenc e from top  to b ottom.
    3. Press hundred s g roup  selec t b utton. The hund red s g roup  selec t lamp  
    lig hts and any lamp s assoc iated  with b usy telephone lig ht.
    4. Press Direct Extension Selection (DXS) button
     for the d esired  
    extension. Aud ib le ring ing  tone is heard  in the earp iec e on attend ant 
    console.
    5. On attend ant c onsole, p ress Release
    . 
    Aud ib le ring ing  tone is silenc ed . 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Test Telephones and Other Equipment 
    6-3 Test External Ringing 
    6
    Test External Ringing
    Make a test c all to the attend ant c onsole to verify ring ing  d evic e sound s when 
    Night
     lamp  on c onsole is lig hted. If ring ing  d evic e has not b een installed  b y 
    c ustomer, c onnec t sp are telep hone to information outlet reserved  for ring ing  
    d evice and  make test call.
    Test Queue Warning Indicator
    Make a test c all to an extension assoc iated  with a Uniform Call Distrib ution (UCD) 
    or Direc t Dep artment Calling  (DDC) g roup , and  verify the q ueue warning  
    indic ator lamp  lig hts. If the q ueue warning  ind ic ator has not b een installed  b y 
    c ustomer, c onnec t a spare telep hone to the information outlet reserved  for q ueue 
    warning ind ic ator and  make a test c all.
    Test Integrated Announcement
    The TN750C Announc ement c irc uit p ac k stores messag es. The messages c an 
    b e rec orded  from telep hones on- or off-p remises and  have flexib le messag e 
    leng ths. The telephone selec ted  as the test telep hone must have a c lass of 
    servic e (COS) with c onsole p ermission enab led .
    Record Announcement
    1. Selec t test telep hone with c onsole p ermission enab led .
    2. Dial ac c ess c od e followed  b y the integ rated announc ement extension 
    numb er. Dial tone is heard .
    3.Dial “ 1.”  A short b urst of tone is heard and  rec ord ing  b egins. Sp eak the 
    announc ement into the telep hone.
    4. Dial “ #”  or hang  up . Rec ord ing  stop s and  d ial tone is heard .
    Playback Announcement
    1. Dial ac c ess c od e followed  b y the integ rated announc ement extension 
    numb er. Dial tone is heard .
    2. Dial “ 2.”  The announc ement is heard  and  d ial tone is heard  at c ompletion 
    of announc ement.
    Delete Announcement
    1. Dial ac c ess c od e followed  b y the integ rated announc ement extension 
    numb er. Dial tone is heard .
    2. Dial “ 3.”  A c onfirmation tone is heard  and  announc ement is d eleted . 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Test Telephones and Other Equipment 
    6-4 Test Music-on-Hold 
    6
    Test Music-on-Hold
    Verify music  is p rovid ed  to a held  p arty during  any hold  interval.
    Test Emergency Transfer
    Put system in emerg enc y transfer mod e and  make c all using  emerg enc y transfer 
    telep hone. There may be up  to 7 Emerg enc y Transfer units, dep end ing  on the 
    system c onfig uration. The switc h is loc ated on the Proc essor c irc uit p ac k(s) in 
    t h e  Pro c e ss o r  Po r t  N e t w o r k (PPN )  c o n t ro l c a r ri e r .
    Test Remote Access Interface
    Test the c ommunic ation link b etween the system and  the remote interfac e 
    (formerly INADS) and  verify the alarm notific ation p roc ess. Make a remote test 
    from the remote interfac e to the DEFINITY System and  a loc al test from the 
    DEFINITY System to the remote interfac e.
    In some c ountries, this remote ac c ess interfac e is not allowed . Contac t your 
    Luc ent Tec hnolog ies rep resentative.
    Remote Test
    1. Call outsid e p ersonnel who will b e ac c essing  the system remotely to 
    p erform ad ministration, maintenanc e, and  testing .
    2. Ask remote p ersonnel to c all system and  log in and  d isp lay System 
    Parameters Maintenanc e sc reen. The log in must b e suc c essful.
    NOTE:
    Produc t Id entific ation on the System Parameters sc reen must matc h 
    the Prod uc t Id entific ation ad ministered  b y the loc al tec hnic ian.
    3. Remote p ersonnel enters test inads-link
     c ommand , terminates login, and  
    d isc onnec ts.
    4. Remote p ersonnel then c hec k the ap p rop riate troub le tic ket. The troub le 
    tic ket should  show INADS,n,MINOR in the desc rip tion field  to ind ic ate a 
    minor off-b oard  alarm was rep orted  to the remote p ersonnel. There may 
    b e more text in the d esc rip tion field  if other resolved  alarms were rep orted .
    5. Remote p ersonnel makes sec ond  c all and  log in to system and  c hec ks the 
    error log to verify no p rob lems. See 
    DEFINITY Enterprise Communic ations 
    Server Release 8 Maintenanc e for R8si, 
    for error log  and  error c od e 
    information.
    6. Remote ac c ess p ersonnel terminate log in and  d isc onnec ts. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Test Telephones and Other Equipment 
    6-5 Test Basic Rate Interface 
    6
    Local Test
    1. Log  in and  enter test inads-link
     c ommand .
    2. Req uest remote ac c ess p ersonnel to verify a troub le tic ket was c reated .
    3. Chec k error log  to verify no prob lems.
    4. Log  off the system.
    Test Basic Rate Interface
    Chec k for normal voic e telephone func tion (d ial tone, ab ility to make and  rec eive 
    c alls). Chec k for the c orrec t Servic e Profile Id entifier (SPID) on a d isp lay 
    telep hone and  the manag ement terminal.
    Test C-LAN Board
    Perform the following  tests of the C-LAN b oard  (Refer to DEFINITY Enterp rise 
    Communic ations Server Release 8 Maintenanc e for R8si 
    for test p roc ed ure 
    details):
    nControl Channel Loop-Around Test
     – This non-d estruc tive test fails if the 
    c irc uit p ac k does not return to a sane state after b eing  reset. This test 
    q ueries the c irc uit p ac k for its c od e and  vintag e, and  verifies its rec ord s.
    nPacket Interface Test
     – This non-d estruc tive test c hec ks the pac ket b us 
    interfac e c irc uitry on the CLAN c irc uit p ac k. Test failure ind ic ates faulty 
    circuit pack.
    nCongestion Query Test
     – This non-d estruc tive test q ueries the numb er of 
    used  b uffers to determine if the CLAN c irc uit pac k is c ong ested .
    Normal c all hand ling  resumes when the CLAN c irc uit pac k has rec overed  
    from c ong estion.
    nLink Status Test
     – This non-d estruc tive test d etermines the state of the 
    c all c ontrol sig naling  link for Control LANs. If the sig naling  link is p hysic ally 
    c onnec ted , the test send s a test frame over the link and  c hec ks for a 
    resp onse. The test passes only if b oth the sig naling link is c onnec ted  and  
    the test frame is suc c essfully transmitted.
    If: Then:
    Used  buffers are, or are 
    nearly, exhausted ,The test fails
    The test fails, The switch red irec ts outg oing  c alls to 
    another availab le CLAN, and  d enies 
    new inc oming  c alls 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Test Telephones and Other Equipment 
    6-6 Test C-LAN Board 
    6
    A failure may ind ic ate a p rob lem with:
    nThis c irc uit p ac k
    nThe packet bus
    nThe p ac ket interfac e c irc uit p ac k 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual