Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-143 Connector and Cable Diagrams (Pinout Charts) 5 Table 5-41. Circuit Pack and Auxiliary Equipment Classifications.Analog Line (8)2-Wire Digital & Analog Line (16)Data Line & Digital Line 4-Wire2-Wire Digital & Analog Line (24) Hybrid LineMET LineAUX Tr u n kCentral Office Tr u n kDID/ DIOD Tr u n kTie Tr u n kDS1 Tie TrunkISDN BRI Line 4-wirePacket Data Line Central Office Tr u n k 3-WireISDN BRI Line 2-wireFour Port DIO D TN467 TN2149 TN726B TN2224 TN762 TN735 TN417 TN429 TN2199 TN429 TN478 TN483 TN556B TN2198 TN553 TN21 8 TN432 TN2135 TN754B TN2214 TN762B TN763 TN493 TN2139 TN458 TN722 TN431 TN468B TN564B TN793 TN763D TN422 TN459B TN449 TN767 TN411B TN448 TN413 TN2793 TN421 TN436B TN760 DTN722B TN742 TN746 TN2214B TN438B TN753 TN760 CTN2464 TN769 TN746B TN2224B TN447 TN2146 TN434 TN2181 TN793B TN465C TN414 TN415 TN2183 TN2793B TN747B TN2215 TN2138 TN7921 TN2147C TN21481. DID means Direc t Inward Dialing 2. DIOD means Direc t Inward Outward Dialing 3. MET means Multibutton Elec tronic Telep hone
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-144 Connector and Cable Diagrams (Pinout Charts) 5 5Table 5-42. Circuit Pack and Auxiliary Equipment Leads (Pinout Charts)Color Connector Pin NumbersAnalog Line 8 ports2-Wire Digital Line & Analog Line 16 portsData Line & Digital Line 4-wire2-Wire Digital Line & Analog Line 24 PortsHybrid LineMET LineAUX TrunkCO Tr k .CO Tr u n k 3-wireDID/ DIOD Tr u n kTie Tr k .DS1 Ti e Tr u n kISDN BRI Line 4-wireISDN BRI Line 2-wirePacket Data LineFour Port DIOD W- B L 2 6 T1 T1 T1 V1 T1 T1 T1 T1 A 1 T1 T1 PXR1 T1 TXT1 T1 B L-W 01 R1 R1 R1 V1R1 R1 R1 R1 B 1 R1 R1 PXT1 R1 TXR1 R1 W- O 2 7 T2 TXT1 T2 C T1 TXT1 SZ 1 T1 1 TXT1 T2 PXT1 O- W 02 R2 TXR1 R2 CR1 TXR1 SZ 11 R11 TXR1 R2 PXR1 W-G 28 T3 PXT1 T3 P-1 PXT1 S1 E1 PXR2 T3 TXT2 G- W 03 R3 PXR1 R3 P+ 1 PXR1 S11 C1 M1 PXT2 R3 TXR2 W- B R 2 9 T2 T4 T4 V1 T2 T2 T2 T2 A 2 T2 T2 TXT2 T4 PXT2 T2 B R-W 04 R2 R4 R4 V1R2 R2 R2 R2 B 2 R2 R2 TXR2 R4 PXR2 R2 W-S 30 TXT2 T5 CT2 TXT2 SZ 2 T1 2 PXR3 T5 TXT3 S- W 05 TXR2 R5 CR2 TXR2 SZ 12 R12 PXT3 R5 TXR3 R-B L 31 PXT2 T6 P-2 PXT2 S2 E2 TXT3 T6 PXT3 B L-R 06 PXR2 R6 P+ 2 PXR2 S12 C 2 M2 TXR3 R6 PXR3 R-O32 T3 T7 V1T3T3T3 T3A3T3T3 PXR4T7TXT4T3 O-R07 R3 R7 V1R3R3R3 R3B3R3R3 PXT4R7TXR4R3 R- G 3 3 TXT3 T8 C T3 TXT3 SZ 3 T1 3 TXT4 T8 PXT4 G- R 08 TXR3 R8 CR3 TXR3 SZ 13 R13 TXR4 R8 PXR4 R-B R 34 T5 PXT3 T9 P-3 PXT3 S3 E3 PXR5 T9 TXT5 B R-R 09 R5 PXR3 R9 P+ 3 PXR3 S13 C 3 M3 PXT5 R9 TXR5 R- S 3 5 T4 T6 T1 0 V1 T4 T4 T4 T4 A 4 T4 T4 TXT5 T1 0 PXT5 T4 S- R 10 R4 R6 R10 V1R4 R4 R4 R4 B 4 R4 R4 TXR5 R1 0 PXR5 R4 BK-BL 36 T7 TXT4 T11 CT4 TXT4 SZ 4 T1 4 PXR6 T11 TXT6 BL-BK 11 R7 TXR4 R11 CR4 TXR4 SZ14 R14 PXT6 R11 TXR6 Continued on next page
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-145 Connector and Cable Diagrams (Pinout Charts) 5 B K -O 37 T8 PXT4 T12 P-4 PXT4 S4 E4 TXT6 T12 PXT6 O- BK 12 R8 PXR4 R12 P+ 4 PXR4 S14 M4 TXR6 R1 2 PXR6 B K - G 3 8 T5 T9 T1 3 V1 T5 T5 T5 PXR7 TXT7 G- BK 13 R5 R9 R13 V1R5 R5 R5 PXT7 TXR7 BK-BR 39 T10 TXT5 T14 CT4TXT7 PXT7 B R-B K 14 R10 TXR5 R14 C R4TXR7 PXR7 BK-S 40 T11 PXT5 T15 P-5PXR8 TXT8 S-BK 15 R11 PXR5 R15 P+ 5PXT8 TXR8 Y- B L 4 1 T6 T1 2 T1 6 V1 T6 T6 T6 TXT8 PXT8 B L-Y 16 R6 R12 R16 V1R6 R6 R6 TXR8 PXR8 Y- O 4 2 TXT6 T1 7 C T6PXR9 TXT9 O-Y 17 TXR6 R17 CR6PXT9 TXR9 Y- G 43 PXT6 T18 P-6TXT9 PXT9 G- Y 18 PXR6 R18 P+ 6TXR9 PXR9 Y-BR 44 T7 T19 V1T7 T7 T7 PXR10 TXT10 B R-Y 19 R7 R19 V1R7 R7 R7 PXT1 0 TXR1 0 Y- S 4 5 TXT7 T2 0 C T7TXT1 0 PXT1 0 S- Y 2 0 TXR7 R2 0 C R7TXR1 0 PXR1 0 V-BL 46 T13 PXT7 T21 P-7PXR1 1 TXT1 1 BL-V 21 R13 PXR7 R21 P+ 7PXT1 1 TXR1 1 V- O 4 7 T8 T1 4 T2 2 V1 T8 T8 T8 L I * TXT1 1 PXT1 1 O-V 22 R8 R14 R22 V1R8 R8 R8 LI TXR11 PXR11 V- G 4 8 T1 5 TXT8 T2 3 C T8 L O PXR1 2 TXT1 2Table 5-42. Circuit Pack and Auxiliary Equipment Leads (Pinout Charts)Color Connector Pin NumbersAnalog Line 8 ports2-Wire Digital Line & Analog Line 16 portsData Line & Digital Line 4-wire2-Wire Digital Line & Analog Line 24 PortsHybrid LineMET LineAUX TrunkCO Tr k .CO Tr u n k 3-wireDID/ DIOD Tr u n kTie Tr k .DS1 Ti e Tr u n kISDN BRI Line 4-wireISDN BRI Line 2-wirePacket Data LineFour Port DIOD Continued on next page
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-146 Connector and Cable Diagrams (Pinout Charts) 5 †The wire colors in this chart apply only to B25A and A25B c ables. H600-307 c able c olors are not shown. The following ab breviations ap p ly for all circuit p ac ks unless otherwise noted: T,R PBX transmit voic e T Tip (A) Green T1,R1 PBX rec eive voice R Ring (B) Red M PBX transmit signal S Sleeve E PBX r ec ei v e s ig n al PX PBX t ra ns m i t TX Te r m i n a l t r a n sm i t LI, LI* Dig ital Trunk IN LO, LO* Digital Trunk OUT The following wire c olors app ly in the ab ove chart: W White S Slate (Grey) BL Blue R Red OOrange BK Black G Green Y Yellow BRBrown V VioletG-V 23 R15 TXR8 R23 C R8 LO* PXT12 TXR1 2 V- B R 4 9 T1 6 PXT8 T2 4 P- 8 L B A C K2 TXT1 2 PXT1 2 B R- V 24 R16 PXR8 R24 P+ 8 LB A C K1 TXR1 2 PXR12 V- S 5 0 S- V 2 5Table 5-42. Circuit Pack and Auxiliary Equipment Leads (Pinout Charts)Color Connector Pin NumbersAnalog Line 8 ports2-Wire Digital Line & Analog Line 16 portsData Line & Digital Line 4-wire2-Wire Digital Line & Analog Line 24 PortsHybrid LineMET LineAUX TrunkCO Tr k .CO Tr u n k 3-wireDID/ DIOD Tr u n kTi e Tr k .DS1 Ti e Tr u n kISDN BRI Line 4-wireISDN BRI Line 2-wirePacket Data LineFour Port DIOD Continued on next page
Test Telephones and Other Equipment 6-1 6 DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 6 Test Telephones and Other Equipment This c hapter d esc rib es how to test the telep hones and other eq uip ment. The following tests must be performed: 1. Make test calls 2. Test 302C Attend ant Console 3. Test Selector Console 4. Test External Ring ing 5. Test Queue Warning Indicator 6. Test Integ rated Announc ement 7. Test Music-on-Hold 8. Test Emerg ency Transfer 9. Test Remote Ac c ess Interfac e (INADS) 10. Test Basic Rate Interfac e (BRI) NOTE: The tests in this c hap ter are p erformed after the eq uip ment has b een wired to the system and after the c ustomer’s data for that eq uip ment has been ad ministered . The following tests are ac c ep tanc e tests or sanity tests and p rovid e some assuranc e the system will p erform p rop erly after installation and ad ministration. If p rob lems oc c ur or more extensive or sp ec ific tests are req uired, refer to DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8si.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test Telephones and Other Equipment 6-2 Make Test Calls 6 Make Test Calls Make two c alls from one telep hone to another telep hone. Make the first c all b y d ialing a telephone and make the sec ond c all b y dialing a trunk ac c ess c od e and a Listed Direc tory Numb er (LDN). Test 302C Attendant Console Chec k all lamp s are op erational and c all another telep hone in the system. 1. Simultaneously p ress and hold the Ringer Volume up button and the POS BUSY button . This p uts the c onsole in the self-test mod e. NOTE: Releasing the buttons c auses the c onsole to return to normal mod e. 2. Verify all lamp s on d isp lay lig ht and remain lighted . Eac h row of lamp s on the c onsole lights and g oes d ark in seq uenc e from top to b ottom. 3. Press Start . Listen for d ial tone. The g reen lamp assoc iated with idle c all ap p earanc e b utton lig hts. Th e Position Available lamp g oes d ark. 4. Dial numb er assoc iated with a working telep hone. Aud ib le ring ing tone is heard in ear p iec e. 5. Press Release . Aud ib le ring ing tone is silenc ed. The g reen lamp assoc iated with idle c all ap p earanc e b utton g oes dark. Th e Position Available lamp lig hts. Test Selector Console Chec k all selec tor c onsole lamp s are op erational. Make c all to a telep hone in the system. 1. Simultaneously p ress and hold the Ringer Volume up button and the POS BUSY button . This p uts the c onsole in the self-test mod e. 2. Eac h row of lamp s on the selec tor c onsole lig hts and g oes d ark in seq uenc e from top to b ottom. 3. Press hundred s g roup selec t b utton. The hund red s g roup selec t lamp lig hts and any lamp s assoc iated with b usy telephone lig ht. 4. Press Direct Extension Selection (DXS) button for the d esired extension. Aud ib le ring ing tone is heard in the earp iec e on attend ant console. 5. On attend ant c onsole, p ress Release . Aud ib le ring ing tone is silenc ed .
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test Telephones and Other Equipment 6-3 Test External Ringing 6 Test External Ringing Make a test c all to the attend ant c onsole to verify ring ing d evic e sound s when Night lamp on c onsole is lig hted. If ring ing d evic e has not b een installed b y c ustomer, c onnec t sp are telep hone to information outlet reserved for ring ing d evice and make test call. Test Queue Warning Indicator Make a test c all to an extension assoc iated with a Uniform Call Distrib ution (UCD) or Direc t Dep artment Calling (DDC) g roup , and verify the q ueue warning indic ator lamp lig hts. If the q ueue warning ind ic ator has not b een installed b y c ustomer, c onnec t a spare telep hone to the information outlet reserved for q ueue warning ind ic ator and make a test c all. Test Integrated Announcement The TN750C Announc ement c irc uit p ac k stores messag es. The messages c an b e rec orded from telep hones on- or off-p remises and have flexib le messag e leng ths. The telephone selec ted as the test telep hone must have a c lass of servic e (COS) with c onsole p ermission enab led . Record Announcement 1. Selec t test telep hone with c onsole p ermission enab led . 2. Dial ac c ess c od e followed b y the integ rated announc ement extension numb er. Dial tone is heard . 3.Dial “ 1.” A short b urst of tone is heard and rec ord ing b egins. Sp eak the announc ement into the telep hone. 4. Dial “ #” or hang up . Rec ord ing stop s and d ial tone is heard . Playback Announcement 1. Dial ac c ess c od e followed b y the integ rated announc ement extension numb er. Dial tone is heard . 2. Dial “ 2.” The announc ement is heard and d ial tone is heard at c ompletion of announc ement. Delete Announcement 1. Dial ac c ess c od e followed b y the integ rated announc ement extension numb er. Dial tone is heard . 2. Dial “ 3.” A c onfirmation tone is heard and announc ement is d eleted .
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test Telephones and Other Equipment 6-4 Test Music-on-Hold 6 Test Music-on-Hold Verify music is p rovid ed to a held p arty during any hold interval. Test Emergency Transfer Put system in emerg enc y transfer mod e and make c all using emerg enc y transfer telep hone. There may be up to 7 Emerg enc y Transfer units, dep end ing on the system c onfig uration. The switc h is loc ated on the Proc essor c irc uit p ac k(s) in t h e Pro c e ss o r Po r t N e t w o r k (PPN ) c o n t ro l c a r ri e r . Test Remote Access Interface Test the c ommunic ation link b etween the system and the remote interfac e (formerly INADS) and verify the alarm notific ation p roc ess. Make a remote test from the remote interfac e to the DEFINITY System and a loc al test from the DEFINITY System to the remote interfac e. In some c ountries, this remote ac c ess interfac e is not allowed . Contac t your Luc ent Tec hnolog ies rep resentative. Remote Test 1. Call outsid e p ersonnel who will b e ac c essing the system remotely to p erform ad ministration, maintenanc e, and testing . 2. Ask remote p ersonnel to c all system and log in and d isp lay System Parameters Maintenanc e sc reen. The log in must b e suc c essful. NOTE: Produc t Id entific ation on the System Parameters sc reen must matc h the Prod uc t Id entific ation ad ministered b y the loc al tec hnic ian. 3. Remote p ersonnel enters test inads-link c ommand , terminates login, and d isc onnec ts. 4. Remote p ersonnel then c hec k the ap p rop riate troub le tic ket. The troub le tic ket should show INADS,n,MINOR in the desc rip tion field to ind ic ate a minor off-b oard alarm was rep orted to the remote p ersonnel. There may b e more text in the d esc rip tion field if other resolved alarms were rep orted . 5. Remote p ersonnel makes sec ond c all and log in to system and c hec ks the error log to verify no p rob lems. See DEFINITY Enterprise Communic ations Server Release 8 Maintenanc e for R8si, for error log and error c od e information. 6. Remote ac c ess p ersonnel terminate log in and d isc onnec ts.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test Telephones and Other Equipment 6-5 Test Basic Rate Interface 6 Local Test 1. Log in and enter test inads-link c ommand . 2. Req uest remote ac c ess p ersonnel to verify a troub le tic ket was c reated . 3. Chec k error log to verify no prob lems. 4. Log off the system. Test Basic Rate Interface Chec k for normal voic e telephone func tion (d ial tone, ab ility to make and rec eive c alls). Chec k for the c orrec t Servic e Profile Id entifier (SPID) on a d isp lay telep hone and the manag ement terminal. Test C-LAN Board Perform the following tests of the C-LAN b oard (Refer to DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8si for test p roc ed ure details): nControl Channel Loop-Around Test – This non-d estruc tive test fails if the c irc uit p ac k does not return to a sane state after b eing reset. This test q ueries the c irc uit p ac k for its c od e and vintag e, and verifies its rec ord s. nPacket Interface Test – This non-d estruc tive test c hec ks the pac ket b us interfac e c irc uitry on the CLAN c irc uit p ac k. Test failure ind ic ates faulty circuit pack. nCongestion Query Test – This non-d estruc tive test q ueries the numb er of used b uffers to determine if the CLAN c irc uit pac k is c ong ested . Normal c all hand ling resumes when the CLAN c irc uit pac k has rec overed from c ong estion. nLink Status Test – This non-d estruc tive test d etermines the state of the c all c ontrol sig naling link for Control LANs. If the sig naling link is p hysic ally c onnec ted , the test send s a test frame over the link and c hec ks for a resp onse. The test passes only if b oth the sig naling link is c onnec ted and the test frame is suc c essfully transmitted. If: Then: Used buffers are, or are nearly, exhausted ,The test fails The test fails, The switch red irec ts outg oing c alls to another availab le CLAN, and d enies new inc oming c alls
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Test Telephones and Other Equipment 6-6 Test C-LAN Board 6 A failure may ind ic ate a p rob lem with: nThis c irc uit p ac k nThe packet bus nThe p ac ket interfac e c irc uit p ac k