Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-83 Add DCS Interface 5 Install Cables 1. Install c ab le from the c ab inet to a hub or Internet Protoc ol (IP) Switc h as req uired. Connec t the 259A c onnec tor to the p ort slot c ontaining the C-LAN c irc uit p ac k. See Fig ure 5-29 . For a p inout of TN799, see Ta b l e 5-25. Figure 5-29. Cable Connection for C-LAN Figure Notes 1. 259A Connec tor 2. DW8A Cab le3. Hub or IP Switc h 1 2 3cydflan2 EWS 101398
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-84 Add DCS Interface 5 Enter Added Translations 1. Get the DOSS order numb er of the upg rad e. Call the reg ional CSA to p erform the step s in this sec tion. 2. To enab le DCS, set the DCS field on the System Parameters-Customer Options form to y . 3. Ad minister the other req uired translation data using the forms listed und er Distrib uted Communic ations System (DCS) in DEFINITY Communic ations System Generic 4 V4 Imp lementation . Save Translations 1. If the system is hig h- or c ritic al-reliab ility, typ e status spe and press En te r to verify that the stand b y SPE is refreshed and that the stand b y d isk is in servic e. 2. Type save translation [spe-a or both] disk and press En te r. This c ommand instruc ts the system to take all translation information in memory and write it to the d isk(s). Table 5-25. TN799 Pinout Backplane Pin 25-Pair Wire Color Lead NamePeripheral Connector Pin 103 White/Orang e TD+ 27 003 Orang e/White TD- 2 104 White/Green RD+ 28 004 Green/White RD- 3
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-85 Add ISDN — PRI 5 Add ISDN — PRI North American 1. Use a TN767E (or later) DS1 or a TN464F DS1/E1 c irc uit p ac k for a sig naling link and up to 23 ISDN — PRI Trunk Group members. 2. Install a Tone-Cloc k c irc uit p ac k to p rovid e sync hronization for the DS1 circuit pack. 3. If using a TN464F, then p ac ket b us sup p ort has not b een ad d ed , req uiring greater than 4 PRI signaling groups, see ‘‘Add Packet Bus Support to R8si’’ on page 5-87 for installation of ad d itional c irc uit p ac ks for p ac ket bus support. As an op tion to the TN768 or TN2182B Tone-Cloc k, a TN780 Tone-Cloc k (installed in the PPN) c an interfac e external Stratum 3 sync hronization for DS1. International 1. Install a TN464C (or later) DS1/E1 c irc uit p ac k for the assig nment of the 2 sig naling c hannels and up to 30 ISDN — PRI Trunk Group memb ers. Eac h E1 sp an p rovid es 32 p orts. 2. Install a Tone-Cloc k c irc uit pac k to p rovid e sync hronization for the DS1/E1 circuit pack. 3. If packet bus support has not been added and greater than 8 PRI sig naling g roups are req uired , see ‘‘Ad d Pac ket Bus Sup p ort to R8si’’ on page 5-87 for installation of ad d itional c irc uit p ac ks for p ac ket b us support. As an op tion to the TN2182B Tone-Cloc k, a TN780 Tone-Cloc k (installed in the PPN) can interface external Stratum 3 sync hronization for DS1. Service Interruption If packet bus support for R8si must be added and TN750s must be installed as p art of that sup p ort, then add ing ISDN — PRI req uires a servic e interruption. Notify the c ustomer in ad vanc e as to when the ad d ition will b e c arried out. See ‘‘Add Packet Bus Support to R8si’’ on page 5-87 for further information. Add Packet Bus Support If p ac ket b us sup p ort is not alread y installed , see ‘‘Ad d Pac ket Bus Supp ort to R8si’’ on page 5-87 and p erform the step s.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-86 Add ISDN — PRI 5 Add Circuit Packs 1. Determine port assig nment of c irc uit p ac ks to be ad d ed . 2. Install the DS1 Interfac e c irc uit p ac k in the assig ned c arrier slot. 3. Install a TN748B (or later) (or the international TN420B/C) Tone Detec tor circuit pack if required. Install Cables 1. Install c ab les from c ab inet to MDF as req uired . Enter Added Translations 1.Ad minister the forms listed und er “ Integ rated Servic es Dig ital Network — Primary Rate Interfac e” in DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e . Resolve Alarms 1. Examine the alarm log. Resolve any alarms that may exist using D EFI N I TY Enterp rise Communic ations Server Release 8 Maintenanc e for R8si . Save Translations 1. If the system is hig h or c ritic al reliab ility, typ e status system 1 and press En t e r to verify that the system is in the “ ac tive/stand b y” mode. 2. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard s. 3. Up d ate b ac kup c ard s, if nec essary.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-87 Add Packet Bus Support to R8si 5 Add Packet Bus Support to R8si Standard Reliability R8si System Service Interruption Installing TN570 Exp ansion Interfac e c irc uit pac ks as part of ad d ing p ac ket b us sup p ort req uires a servic e interrup tion. Notify the c ustomer in ad vanc e as to when the ad d ition will b e c arried out. If not installing TN570 c irc uit p ac ks, then servic e is not interrup ted and you c an skip to the Install Circ uit Pac ks sec tion. Set Offer Category and Activate Offer 1. Type change system-parameters offer and press En t e r. 2. Set the Offer Category field to A , if not alread y set. 3. Set the Activate Offer field to y . Disable Alarm Origination 1. Type change system-parameters maintenance and press En t e r. 2. Set the Alarm Origination Activated field to n . !CAUTION: If you d o not d isab le Alarm Orig ination, the system may g enerate alarms, resulting in unnec essary troub le tic kets. 3. For some releases of software, disab le Cleared Alarm Notification and Restart Notification b efore sub mitting the form. Save Translations 1. If the system is hig h or c ritic al reliab ility, typ e status system 1 and press En t e r to verify that the system is in the “ ac tive/stand b y” mode. 2. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard . 3. If the system c ontains a TN750/B Announc ement c irc uit p ac k, type display announcements and p ress En t e r. If ad ministered rec orded announc ements are listed , typ e list configuration software-version long and p ress En t e r. To save the announc ements, typ e save announcements and p ress En t e r.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-88 Add Packet Bus Support to R8si 5 Power Down Cabinet 1. At the PPN, set the main c irc uit b reaker to OFF. 2. At an EPN, set the main c irc uit b reaker to OFF. Install Circuit Packs 1. Install the ap p rop riate c irc uit pac ks. See Tab le 5-26. Power Up System 1. At the EPN, set the main c irc uit b reaker to ON. 2. At the PPN, set the main c irc uit b reaker to ON. 3. The system p erforms a level 4 reb oot, load ing the system translations from the translation c ard s. Reb ooting takes ab out 10 minutes. 4. After all troub le is c leared , verify the EMERGENCY TRANSFER CONTROL switc h is set to AUTO. This restores the system to the normal mod e. Test the Packet Bus and C-LAN Circuit Pack 1. Type test packet port-network 1 long and p ress En t e r. For more d etail ab out these tests, refer to the test p kt c ommand sec tion in the maintenanc e b ook. Resolve Alarms 1. Examine the alarm log . Resolve any alarms using DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8si . Table 5-26. Circuit Pack Locations for Packet Bus in R8 PPN Circuit Pack Carrier Quantity Slot TN570 Control Carrier A 1 or 2 1 1. Quantity of this p ack should equal the numb er of EPNs. EXPN INTFC/1 and /2 TN771C Control Carrier A 1 2 2. Op tional for d ig ital trunk testing . Any Availab le Port Slot
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-89 Add Packet Bus Support to R8si 5 Enable Customer Options and Alarm Origination 1. Get the DOSS order numb er of the upg rad e and c all the reg ional CSA to p erform the step s in this sec tion. 2. To use Ac cess Security Gateway (ASG), see Appendix D, ‘‘Access Sec urity Gateway’’. 3. Type change system-parameters customer-options and press En te r. Use these forms to verify the c ustomer op tions are p roperly set. NOTE: If the c ustomer was using Sup p lementary Servic es Protoc ol “ b ” or “ d” on an ISDN-PRI trunk g roup b efore the up g rad e, set the Basic Call Setup field on the QSIG Op tional Features p ag e to y . 4. Be sure the system is p art of the existing INADS d atab ase b y c alling the INADS Datab ase Administrator at the Tec hnic al Servic e Center (TSC). Verify that INADS c an d ial into the system and that the system c an d ial out to INADS. As p art of the system reg istration proc ess, the INADS Datab ase Ad ministrator enab les Alarm Orig ination and c ustomer op tions. !CAUTION: If you d o not enab le Alarm Orig ination when the c ustomer has p urc hased a servic es c ontrac t, the system c annot rep ort any alarm to the TSC automatic ally, c ausing the TSC to b e unab le to fulfill the servic es c ontrac t. Save Translations 1. If the system is hig h or c ritic al reliab ility, typ e status system 1 and press En t e r to verify that the system is in the “ ac tive/stand b y” mode. 2. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard s. 3. If the system c ontains a TN750/B/C Announc ement c irc uit pac k, typ e restore announcements and press En t e r. 4. Up d ate b ac kup c ard s, if nec essary.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-90 Add Packet Bus Support to R8si 5 High or Critical Reliability R8si System Service Interruption If no TN570 Exp ansion Interfac e c irc uit p ac ks need to b e installed for PktBus sup p ort, skip to and p erform only the Install Circ uit Pac ks sec tion. This p roc ed ure d oes not interrup t servic e in this c ase. Set Offer Category and Activate Offer 1. Type change system-parameters offer and press En t e r. 2. Set the Offer Category field to A , if not alread y set. 3. Set the Activate Offer field to y . Disable Alarm Origination 1. Type change system-parameters maintenance and press En t e r. 2. Set the Alarm Origination Activated to OSS Numbers field to n . !CAUTION: If you d o not d isab le Alarm Orig ination, the system may g enerate alarms, resulting in unnec essary troub le tic kets. 3. For some releases of software, disab le Cleared Alarm Notification and Restart Notification b efore sub mitting the form. Save Translations 1. If the system is hig h or c ritic al reliab ility, typ e status system 1 and press En t e r to verify that the system is in the “ ac tive/stand b y” mode. 2. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard s. 3. If the system c ontains a TN750/B Announc ement c irc uit p ac k, type display announcements and p ress En t e r. If ad ministered rec orded announc ements are listed , typ e list configuration software-version long and p ress En t e r. To save the announc ements, typ e save announcements and p ress En t e r. Power Down Cabinet (Standby Cabinet) 1. At the PPN, set the main c irc uit b reaker to OFF. 2. At an EPN, set the main c irc uit b reaker to OFF.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-91 Add Packet Bus Support to R8si 5 Install Circuit Packs 1. Install the ap p rop riate c irc uit pac ks. See Tab le 5-27. Power Up System 1. At the EPN, set the main c irc uit b reaker to ON. 2. At the PPN, set the main c irc uit b reaker to ON. 3. The system p erforms a level 4 reb oot, load ing the system translations from the translation c ard s. Reb ooting takes ab out 10 minutes. 4. After all troub le is c leared , verify the EMERGENCY TRANSFER CONTROL switc h is set to AUTO. This restores the system to the normal mod e. Test the Packet Bus and C-LAN Circuit Pack 1. Type test packet port-network 1 long and p ress En t e r. For more d etail ab out these tests, refer to the “ test p kt c ommand ” sec tion in the DEFINITY Enterp rise Communic ations Server Release 8 Maintenanc e for R8si . Resolve Alarms 1. Examine the alarm log. Resolve any alarms that may exist using D EFI N I TY Enterp rise Communic ations Server Release 8 Maintenanc e for R8si. Table 5-27. Circuit Pack Locations for Packet Bus in PPN Circuit Pack Carrier Quantity Slot TN570 Control Carrier A 1 or 2 1 1. Quantity of this p ack should equal the numb er of EPNs.EXPN INTFC/1 and /2 Control Carrier B 1 or 2 EXPN INTFC/1 and /2 TN771C Control Carrier A 1 2 2. Req uired for critic al-reliab ility EPNs and PPN. Optional for d ig ital trunk testing in hig h-reliab ility PPN. Any Availab le Port Slot
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-92 Add Packet Bus Support to R8si 5 Enable Customer Options and Alarm Origination 1. Get the DOSS order numb er of the upg rad e. Call the reg ional CSA to p erform the step s in this sec tion. 2. To use Ac cess Security Gateway (ASG), see Appendix D, ‘‘Access Sec urity Gateway’’. 3. Type change system-parameters customer-options and press En te r. Use these forms to verify the c ustomer op tions are p roperly set. NOTE: If the c ustomer was using Sup p lementary Servic es Protoc ol “ b ” or “ d” on an ISDN-PRI trunk g roup b efore the up g rad e, set the Basic Call Setup field on the QSIG Op tional Features p ag e to y . 4. Be sure the system is p art of the existing INADS d atab ase b y c alling the INADS Datab ase Administrator at the Tec hnic al Servic e Center (TSC). Verify that INADS c an d ial into the system and that the system c an d ial out to INADS. As p art of the system reg istration proc ess, the INADS Datab ase Ad ministrator enab les Alarm Orig ination and c ustomer op tions. !CAUTION: If you d o not enab le Alarm Orig ination when the c ustomer has p urc hased a servic es c ontrac t, the system c annot rep ort any alarm to the TSC automatic ally, c ausing the TSC to b e unab le to fulfill the servic es c ontrac t. Save Translations 1. If the system is hig h or c ritic al reliab ility, typ e status system 1 and press En t e r to verify that the system is in the “ ac tive/stand b y” mode. 2. Type save translation and press En te r. This instruc ts the system to take all translation information in memory and write it to the translation c ard s. 3. If the system c ontains a TN750/B/C Announc ement c irc uit pac k, typ e restore announcements and press En t e r. 4. Up d ate b ac kup c ard s, if nec essary.