    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-83 Add DCS Interface 
    5
    Install Cables
    1. Install c ab le from the c ab inet to a hub  or Internet Protoc ol (IP) Switc h as 
    req uired. Connec t the 259A c onnec tor to the p ort slot c ontaining the 
    C-LAN c irc uit p ac k. See Fig ure 5-29
    . For a p inout of TN799, see Ta b l e  
    5-25. 
    Figure 5-29. Cable Connection for C-LAN Figure Notes
    1. 259A Connec tor
    2. DW8A Cab le3. Hub  or IP Switc h
    1
    2
    3cydflan2  EWS 101398 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-84 Add DCS Interface 
    5
    Enter Added Translations
    1. Get the DOSS order numb er of the upg rad e. Call the reg ional CSA to 
    p erform the step s in this sec tion.
    2. To enab le DCS, set the DCS
     field  on the System Parameters-Customer 
    Options form to y
    .
    3. Ad minister the other req uired  translation data using  the forms listed  und er 
    Distrib uted  Communic ations System (DCS) in 
    DEFINITY Communic ations 
    System Generic  4 V4 Imp lementation
    .
    Save Translations
    1. If the system is hig h- or c ritic al-reliab ility, typ e status spe
     and press En te r  
    to verify that the stand b y SPE is refreshed  and  that the stand b y d isk is in 
    servic e.
    2. Type save translation [spe-a or both] disk
     and press 
    En te r. This 
    c ommand  instruc ts the system to take all translation information in 
    memory and  write it to the d isk(s).
    Table 5-25. TN799 Pinout
    Backplane Pin 25-Pair Wire Color Lead NamePeripheral 
    Connector Pin
    103 White/Orang e TD+ 27
    003 Orang e/White TD- 2
    104 White/Green RD+ 28
    004 Green/White RD- 3 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-85 Add ISDN — PRI 
    5
    Add ISDN — PRI
    North American
    1. Use a TN767E (or later) DS1 or a TN464F DS1/E1 c irc uit p ac k for a 
    sig naling  link and  up  to 23 ISDN — PRI Trunk Group members. 
    2. Install a Tone-Cloc k c irc uit p ac k to p rovid e sync hronization for the DS1 
    circuit pack. 
    3. If using  a TN464F, then p ac ket b us sup p ort has not b een ad d ed , req uiring  
    greater than 4 PRI signaling groups, see ‘‘Add Packet Bus Support to 
    R8si’’ on page 5-87 for installation of ad d itional c irc uit p ac ks for p ac ket 
    bus support.
    As an op tion to the TN768 or TN2182B Tone-Cloc k, a TN780 Tone-Cloc k 
    (installed  in the PPN) c an interfac e external Stratum 3 sync hronization for DS1.
    International
    1. Install a TN464C (or later) DS1/E1 c irc uit p ac k for the assig nment of the 2 
    sig naling  c hannels and  up  to 30 ISDN — PRI Trunk Group  memb ers. Eac h 
    E1 sp an p rovid es 32 p orts. 
    2. Install a Tone-Cloc k c irc uit pac k to p rovid e sync hronization for the DS1/E1 
    circuit pack.
    3. If packet bus support has not been added and greater than 8 PRI 
    sig naling  g roups are req uired , see ‘‘Ad d Pac ket Bus Sup p ort to R8si’’ on 
    page 5-87 for installation of ad d itional c irc uit p ac ks for p ac ket b us 
    support.
    As an op tion to the TN2182B Tone-Cloc k, a TN780 Tone-Cloc k (installed  in the 
    PPN) can interface external Stratum 3 sync hronization for DS1.
    Service Interruption
    If packet bus support for R8si must be added and TN750s must be installed as 
    p art of that sup p ort, then add ing  ISDN — PRI req uires a servic e interruption. 
    Notify the c ustomer in ad vanc e as to when the ad d ition will b e c arried  out. See 
    ‘‘Add Packet Bus Support to R8si’’ on page 5-87
     for further information.
    Add Packet Bus Support
    If p ac ket b us sup p ort is not alread y installed , see ‘‘Ad d  Pac ket Bus Supp ort to 
    R8si’’ on page 5-87 and  p erform the step s. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-86 Add ISDN — PRI 
    5
    Add Circuit Packs
    1. Determine port assig nment of c irc uit p ac ks to be ad d ed .
    2. Install the DS1 Interfac e c irc uit p ac k in the assig ned c arrier slot.
    3. Install a TN748B (or later) (or the international TN420B/C) Tone Detec tor 
    circuit pack if required.
    Install Cables
    1. Install c ab les from c ab inet to MDF as req uired .
    Enter Added Translations
    1.Ad minister the forms listed  und er “ Integ rated  Servic es Dig ital Network — 
    Primary Rate Interfac e”  in 
    DEFINITY Enterp rise Communic ations Server 
    Release 8 Ad ministrator’s Guid e
    .
    Resolve Alarms
    1. Examine the alarm log. Resolve any alarms that may exist using  D EFI N I TY 
    Enterp rise Communic ations Server Release 8 Maintenanc e for R8si
    . 
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    3. Up d ate b ac kup  c ard s, if nec essary. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-87 Add Packet Bus Support to R8si 
    5
    Add Packet Bus Support to R8si
    Standard Reliability R8si System
    Service Interruption
    Installing  TN570 Exp ansion Interfac e c irc uit pac ks as part of ad d ing  p ac ket b us 
    sup p ort req uires a servic e interrup tion. Notify the c ustomer in ad vanc e as to 
    when the ad d ition will b e c arried  out. If not installing  TN570 c irc uit p ac ks, then 
    servic e is not interrup ted  and  you c an skip  to the Install Circ uit Pac ks sec tion.
    Set Offer Category and Activate Offer
    1. Type change system-parameters offer
     and press En t e r.
    2. Set the Offer Category
     field  to A
    , if not alread y set.
    3. Set the Activate Offer
     field  to y
    . 
    Disable Alarm Origination
    1. Type change system-parameters maintenance
     and press En t e r. 
    2. Set the Alarm Origination Activated
     field  to n
    .
    !CAUTION:
    If you d o not d isab le Alarm Orig ination, the system may g enerate 
    alarms, resulting  in unnec essary troub le tic kets. 
    3. For some releases of software, disab le Cleared Alarm Notification
     
    and  Restart Notification
     b efore sub mitting  the form.
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard .
    3. If the system c ontains a TN750/B Announc ement c irc uit p ac k, type 
    display announcements
     and  p ress 
    En t e r. If ad ministered  rec orded  
    announc ements are listed , typ e list configuration software-version long
     
    and  p ress 
    En t e r. To save the announc ements, typ e save announcements
     
    and  p ress 
    En t e r. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-88 Add Packet Bus Support to R8si 
    5
    Power Down Cabinet 
    1. At the PPN, set the main c irc uit b reaker to OFF.
    2. At an EPN, set the main c irc uit b reaker to OFF.
    Install Circuit Packs
    1. Install the ap p rop riate c irc uit pac ks. See Tab le 5-26.
    Power Up System
    1. At the EPN, set the main c irc uit b reaker to ON.
    2. At the PPN, set the main c irc uit b reaker to ON.
    3. The system p erforms a level 4 reb oot, load ing  the system translations from 
    the translation c ard s. Reb ooting  takes ab out 10 minutes.
    4. After all troub le is c leared , verify the EMERGENCY TRANSFER CONTROL 
    switc h is set to AUTO. This restores the system to the normal mod e.
    Test the Packet Bus and C-LAN Circuit Pack
    1. Type test packet port-network 1 long 
    and p ress En t e r. For more d etail 
    ab out these tests, refer to the test p kt c ommand  sec tion in the 
    maintenanc e b ook. 
    Resolve Alarms
    1. Examine the alarm log . Resolve any alarms using  DEFINITY Enterp rise 
    Communic ations Server Release 8 Maintenanc e for R8si
    . 
    Table 5-26. Circuit Pack Locations for Packet Bus in R8 PPN
    Circuit Pack Carrier Quantity Slot
    TN570 Control Carrier A 1 or 2
    1
    1. Quantity of this p ack should  equal the numb er of EPNs.
    EXPN INTFC/1 and  /2
    TN771C Control Carrier A 1
    2
    2. Op tional for d ig ital trunk testing .
    Any Availab le Port Slot 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-89 Add Packet Bus Support to R8si 
    5
    Enable Customer Options and Alarm Origination
    1. Get the DOSS order numb er of the upg rad e and  c all the reg ional CSA to 
    p erform the step s in this sec tion.
    2. To use Ac cess Security Gateway (ASG), see Appendix D, ‘‘Access 
    Sec urity Gateway’’.
    3. Type change system-parameters customer-options
     and press 
    En te r. 
    Use these forms to verify the c ustomer op tions are p roperly set.
    NOTE:
    If the c ustomer was using  Sup p lementary Servic es Protoc ol “ b ”  or 
    “ d”  on an ISDN-PRI trunk g roup  b efore the up g rad e, set the Basic 
    Call Setup 
    field  on the QSIG Op tional Features p ag e to y
    .
    4. Be sure the system is p art of the existing  INADS d atab ase b y c alling  the 
    INADS Datab ase Administrator at the Tec hnic al Servic e Center (TSC). 
    Verify that INADS c an d ial into the system and  that the system c an d ial out 
    to INADS. 
    As p art of the system reg istration proc ess, the INADS Datab ase 
    Ad ministrator enab les Alarm Orig ination and  c ustomer op tions.
    !CAUTION:
    If you d o not enab le Alarm Orig ination when the c ustomer has p urc hased  a 
    servic es c ontrac t, the system c annot rep ort any alarm to the TSC 
    automatic ally, c ausing the TSC to b e unab le to fulfill the servic es c ontrac t.
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    3. If the system c ontains a TN750/B/C Announc ement c irc uit pac k, typ e 
    restore announcements
     and press 
    En t e r.
    4. Up d ate b ac kup  c ard s, if nec essary. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-90 Add Packet Bus Support to R8si 
    5
    High or Critical Reliability R8si System
    Service Interruption
    If no TN570 Exp ansion Interfac e c irc uit p ac ks need  to b e installed  for PktBus 
    sup p ort, skip  to and p erform only the Install Circ uit Pac ks sec tion. This 
    p roc ed ure d oes not interrup t servic e in this c ase.
    Set Offer Category and Activate Offer
    1. Type change system-parameters offer
     and press En t e r.
    2. Set the Offer Category
     field  to A
    , if not alread y set.
    3. Set the Activate Offer
     field  to y
    . 
    Disable Alarm Origination
    1. Type change system-parameters maintenance
     and press En t e r. 
    2. Set the Alarm Origination Activated to OSS Numbers 
    field to n
    .
    !CAUTION:
    If you d o not d isab le Alarm Orig ination, the system may g enerate 
    alarms, resulting  in unnec essary troub le tic kets. 
    3. For some releases of software, disab le Cleared Alarm Notification
     
    and  Restart Notification
     b efore sub mitting  the form.
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    3. If the system c ontains a TN750/B Announc ement c irc uit p ac k, type 
    display announcements
     and  p ress 
    En t e r. If ad ministered  rec orded  
    announc ements are listed , typ e list configuration software-version long
     
    and  p ress 
    En t e r. To save the announc ements, typ e save announcements
     
    and  p ress 
    En t e r.
    Power Down Cabinet (Standby Cabinet)
    1. At the PPN, set the main c irc uit b reaker to OFF.
    2. At an EPN, set the main c irc uit b reaker to OFF. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-91 Add Packet Bus Support to R8si 
    5
    Install Circuit Packs
    1. Install the ap p rop riate c irc uit pac ks. See Tab le 5-27.
    Power Up System
    1. At the EPN, set the main c irc uit b reaker to ON.
    2. At the PPN, set the main c irc uit b reaker to ON.
    3. The system p erforms a level 4 reb oot, load ing  the system translations from 
    the translation c ard s. Reb ooting  takes ab out 10 minutes.
    4. After all troub le is c leared , verify the EMERGENCY TRANSFER CONTROL 
    switc h is set to AUTO. This restores the system to the normal mod e.
    Test the Packet Bus and C-LAN Circuit Pack
    1. Type test packet port-network 1 long 
    and p ress En t e r. For more d etail 
    ab out these tests, refer to the “ test p kt c ommand ”  sec tion in the 
    DEFINITY 
    Enterp rise Communic ations Server Release 8 Maintenanc e for R8si
    . 
    Resolve Alarms
    1. Examine the alarm log. Resolve any alarms that may exist using  D EFI N I TY 
    Enterp rise Communic ations Server Release 8 Maintenanc e for R8si.
     
    Table 5-27. Circuit Pack Locations for Packet Bus in PPN
    Circuit Pack Carrier Quantity Slot
    TN570 Control Carrier A 1 or 2
    1
    1. Quantity of this p ack should  equal the numb er of EPNs.EXPN INTFC/1 and  /2
    Control Carrier B 1 or 2 EXPN INTFC/1 and  /2
    TN771C Control Carrier A 1
    2
    2. Req uired  for critic al-reliab ility EPNs and PPN. Optional for d ig ital trunk testing  in
    hig h-reliab ility PPN.
    Any Availab le Port Slot 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-92 Add Packet Bus Support to R8si 
    5
    Enable Customer Options and Alarm Origination
    1. Get the DOSS order numb er of the upg rad e. Call the reg ional CSA to 
    p erform the step s in this sec tion.
    2. To use Ac cess Security Gateway (ASG), see Appendix D, ‘‘Access 
    Sec urity Gateway’’.
    3. Type change system-parameters customer-options
     and press 
    En te r. 
    Use these forms to verify the c ustomer op tions are p roperly set.
    NOTE:
    If the c ustomer was using  Sup p lementary Servic es Protoc ol “ b ”  or 
    “ d”  on an ISDN-PRI trunk g roup  b efore the up g rad e, set the Basic 
    Call Setup 
    field  on the QSIG Op tional Features p ag e to y
    .
    4. Be sure the system is p art of the existing  INADS d atab ase b y c alling  the 
    INADS Datab ase Administrator at the Tec hnic al Servic e Center (TSC). 
    Verify that INADS c an d ial into the system and  that the system c an d ial out 
    to INADS. 
    As p art of the system reg istration proc ess, the INADS Datab ase 
    Ad ministrator enab les Alarm Orig ination and  c ustomer op tions.
    !CAUTION:
    If you d o not enab le Alarm Orig ination when the c ustomer has p urc hased  a 
    servic es c ontrac t, the system c annot rep ort any alarm to the TSC 
    automatic ally, c ausing the TSC to b e unab le to fulfill the servic es c ontrac t.
    Save Translations
    1. If the system is hig h or c ritic al reliab ility, typ e status system 1
     and press 
    En t e r  to verify that the system is in the “ ac tive/stand b y”  mode.
    2. Type save translation
     and press 
    En te r. This instruc ts the system to take all 
    translation information in memory and  write it to the translation c ard s.
    3. If the system c ontains a TN750/B/C Announc ement c irc uit pac k, typ e 
    restore announcements
     and press 
    En t e r.
    4. Up d ate b ac kup  c ard s, if nec essary. 
    						