    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-133 Installing a 3150/3170 Channel Service Unit 
    5
    Installing a 3150/3170 
    Channel Service Unit
    1. Install the CSU as shown in Figure 5-39. For some installations (such as a 
    DS1 c onverter), use a Y-c ab le to c onnec t the DEFINITY System to the 
    q uad  c ab le. Fig ure 5-40
     shows the Y-c ab le leng ths. Be sure to lab el all 
    cables. 
    Figure 5-39
     shows a typ ic al c onnec tion from the H600-348 Quad  c ab le to 
    the CSU, through the H600-307 network c ab le, and  to the network 
    interfac e throug h the smart jac ks. The q uad  c ab le p rovid es up  to four 
    c onnec tions using a 15-pin c onnec tor that p lug s into the DTE jac k on eac h 
    CSU. The H600-348 q uad  c ab le may req uire an ad ap ter c ab le.
    Figure 5-39. 3150/3170 Channel Service Unit Connections 
    1. H600-348 q uad  c ab le
    2. 15-p in male “ D”  c onnec tors (to DTE jac ks on CSU)
    3. Channel servic e unit (CSU)
    4. H600-307 c ab le (RJ-48C to RJ-48C)5. Network interfac e
    6. Smart jac k (if p rovid ed)
    7. Cable A
    8. Cable B9. Cab le C
    10. Cab le D
    3150csu RBP 062696
    POWERAUX PORT COM PORT MODEM
    DTENETWORK
    POWERAUX PO RT C OM PORT M OD EM
    DTENETWORK
    POWERAUX PORT COM PORT MODEM
    DTENETWORK
    POWERAUX PORT COM PORT MODEM
    DTENETWORK 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-134 Installing a 3150/3170 Channel Service Unit 
    5
    Figure 5-40. DS1 Converter Connections Using Double-Headed cable
    Figure Notes
    1. Port carrier
    2. Bac kp lane c onnec tor for TN570C EI
    3. Bac kp lane c onnec tor for DS1 Converter
    4. 50-p air female c onnec tor to EI c onnec tor5. 14-in. (35.6 c m) Y c ab le
    6. 50-p in male/50-p in female d ouble-headed  
    c onnec tor
    7. H600-348 Quad  Cab le (with 50-p in male 
    c onnec tor), whic h c onnec ts the Y c ab le to 
    the 4 CSUs.
    Table 5-34. Y Cable Lengths
    Length Description Comcode
    14 in. (35.6 c m) TN1654 c irc uit p ac k to adjac ent EI c irc uit 
    p ac k or TN573B SNI c irc uit p ac k in same 
    carrier847245750
    70 in. (178 c m) TN1654 c irc uit p ac k to EI c irc uit p ac k or SNI 
    c irc uit p ac k in another c arrier847245768
    14 in. (35.6 c m) TN1654 c irc uit p ac k to fib er op tic  
    transc eiver (DC-p owered  c ab inets only). 
    This c ab le is for interc ab inet c ab ling  only.847245776
    cydf010 KLC 091399
    20
    1916 17 18 15 14 13 12 1110
    09 08 07 06 05 04 03 02 01
    1
    4
    5
    6
    7
    A
    2
    3 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-135 Connector and Cable Diagrams (Pinout Charts) 
    5
    Connector and Cable Diagrams 
    (Pinout Charts)
    See Tab le 5-35 for lead  d esig nations. The c irc uit pac ks and  auxiliary equip ment 
    are c lassified  as shown in Tab le 5-25.
    Table 5-35. Lead and Color Designations 
    1W-BL26102
    2 BL-W 01 002
    3W-O27103
    4O-W02003
    5W-G28104
    6G-W03004
    7W-BR29105
    8BR-W04005
    9W-SL30106
    10 SL-W 05 006
    11 R-BL 31 107
    12 BL-R 06 007
    13 R-O 32 108
    14 O-R 07 008
    15 R-G 33 109
    16 G-R 08 009
    17 R-BR 34 110
    18 BR-R 09 010
    19 R-SL 35 111
    20 SL-R 10 011
    21 BK-BL 36 112
    22 BL-BK 11 012
    23 BK-O 37 113
    24 O-BK 12 013
    25 BK-G 38 302
    26 G-BK 13 202
    Continued on next page 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-136 Connector and Cable Diagrams (Pinout Charts) 
    5
    Tab le 5-36 shows the p inouts for the TN799 CLAN c irc uit p ac k.
    27 BK-BR 39 303
    28 BR-BK 14 203
    29 BK-SL 40 304
    30 SL-BK 15 204
    31 Y-BL 41 305
    32 BL-Y 16 205
    33 Y-O 42 306
    34 O-Y 17 206
    35 Y-G 43 307
    36 G-Y 18 207
    37 Y-BR 44 308
    38 BR-Y 19 208
    39 Y-SL 45 309
    40 SL-Y 20 209
    41 V-BL 46 310
    42 BL-V 21 210
    43 V-O 47 311
    44 O-V 22 211
    45 V-G 48 312
    46 G-V 23 212
    47 V-BR 49 313
    48 BR-V 24 213
    49 V-SL 50 300
    50 SL-V 25 200
    Table 5-35. Lead and Color Designations  — Continued
    Continued on next page 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-137 Connector and Cable Diagrams (Pinout Charts) 
    5
    Tab le 5-37 shows the p inouts for the TN2185 ISDN-BRI 4-wire S Interfac e. 
    Table 5-36. TN799 Pinout
    Backplane Pin 25-Pair Wire Color Lead NamePeripheral 
    Connector Pin
    103 White/Orang e TD+ 27
    003 Orang e/White TD- 2
    104 White/Green RD+ 28
    004 Green/White RD- 3 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-138 Connector and Cable Diagrams (Pinout Charts) 
    5
    Table 5-37. TN2185 ISDN-BRI — 4-Wire S Interface Pinout
    Port Signal Cross-Connect Pin  Color Amphenol Pin  Backplane  Pin
    1TXT.1 1 W-BL 26 102
    TXR. 1 2 B L - W 0 1 0 0 2
    PXT. 1 3 W- O 2 7 1 0 3
    PXR. 1 4 O -W 0 2 0 0 3
    2TXT.2 5 W-G 28 104
    TXR. 2 6 G -W 0 3 0 0 4
    PXT. 2 7 W-B R 2 9 1 0 5
    PXR. 2 8 BR- W 0 4 0 0 5
    3TXT.3 9 W-SL 30 106
    TXR.3 10 SL-W 05 006
    PXT.3 11 R-BL 31 107
    PXR.3 12 BL-R 06 007
    4TXT.4 13 R-O 32 108
    TXR. 4 1 4 O - R 0 7 0 0 8
    PXT. 4 1 5 R-G 3 3 1 0 9
    PXR. 4 1 6 G - R 0 8 0 0 9
    5 TXT.5 17 R-BR 34 110
    TXR. 5 1 8 B R- R 0 9 0 1 0
    PXT. 5 1 9 R- SL 3 5 1 1 1
    PXR. 5 2 0 SL - R 1 0 0 1 1
    6TXT.6 21 BK-BL 36 112
    TXR.6 22 BL-BK 11 012
    PXT.6 23 BK-O 37 113
    PXR.6 24 O-BK 12 013
    7 TXT.7 25 BK-G 38 302
    TXR. 7 2 6 G - B K 1 3 2 0 2
    PXT. 7 2 7 B K- B R 3 9 3 0 3
    PXR. 7 2 8 B R- B K 1 4 2 0 3
    8TXT.8 29 BK-SL 40 304
    TXR.8 30 SL-BK 15 204
    PXT. 8 3 1 Y- BL 4 1 3 0 5
    PXR.8 32 BL-Y 16 205 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-139 Connector and Cable Diagrams (Pinout Charts) 
    5
    Tab le 5-38 shows the p inouts for the TN2198 ISDN-BRI 2-wire U Interfac e.
    * 
    Pins 25 and  50 are g round ed  b y the b ac kp lane.
    Table 5-38. TN2198 ISDN-BRI — 2-Wire U Interface Pinout
    Port Signal Cross-Connect 
    Pin ColorAmphenol 
    Pin Backplane Pin
    1T.1 1 W-BL 26 102
    R.1 2 BL- W 0 1 00 2
    2T.2 3 W-O 27 103
    R.2 4 O - W 0 2 00 3
    3T.3 5 W-G 28 104
    R.3 6 G - W 0 3 00 4
    4T.4 7 W-BR 29 105
    R.4 8 BR- W 0 4 00 5
    5T.5 9 W-SL 30 106
    R.5 10 SL- W 0 5 00 6
    6 T.6 11 R-BL 31 107
    R.6 12 BL-R 06 007
    7T.7 13 R-O 32 108
    R.7 14 O - R 0 7 00 8
    8T.8 15 R-G 33 109
    R.8 16 G - R 0 8 00 9
    9 T.9 17 R-BR 34 110
    R.918BR-R09 010
    10 T.10 19 R-SL 35 111
    R.10 20 SL-R 10 011
    11 T.11 21 BK-BL 36 112
    R.11 22 BL-BK 11 012
    12 T.12 23 BK-O 37 113
    R.12 24 O-BK 12 013 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-140 Connector and Cable Diagrams (Pinout Charts) 
    5
    Tab le 5-39 shows the pinout for the TN793 24-Port Analog Line circuit pack.
    Table 5-39. TN793 Analog Line Circuit Pack Pinout 
    Port SignalCross-Connect 
    Pin Color Amphenol Pin Backplane Pin
    1T.1 1 W-BL 26 102
    R.1 2 BL-W 01 002
    2 T.2 3 W-O 27 103
    R.2 4 O -W 0 2 0 03
    3 T.3 5 W-G 28 104
    R.3 6 G -W 0 3 0 04
    4T.4 7 W-BR 29 105
    R.4 8 BR-W 04 005
    5T.5 9 W-SL 30 106
    R.5 10 SL-W 05 006
    6 T.6 11 R-BL 31 107
    R.6 12 BL-R 06 007
    7 T.7 13 R-O 32 108
    R.7 14 O-R 07 008
    8 T.8 15 R-G 33 109
    R.8 16 G-R 08 009
    9 T.9 17 R-BR 34 110
    R.9 18 B R- R 0 9 0 10
    10 T.10 19 R-SL 35 111
    R.10 20 SL-R 10 011
    11 T.11 21 BK-BL 36 112
    R.11 22 BL-BK 11 012
    12 T.12 23 BK-O 37 113
    R.12 24 O-BK 12 013
    13 T.13 25 BK-G 38 302
    R.13 26 G-BK 13 202
    14 T.14 27 BK-BR 39 303
    Continued on next page 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-141 Connector and Cable Diagrams (Pinout Charts) 
    5
    R.14 28 BR-BK 14 203
    15 T.15 29 BK-SL 40 304
    R.15 30 SL-BK 15 204
    16 T.16 31 Y-BL 41 305
    R.16 32 BL-Y 16 205
    17 T.17 33 Y-O 42 306
    R.17 34 O-Y 17 206
    18 T.18 35 Y-G 43 307
    R.18 36 G-Y 18 207
    19 T.19 37 Y-BR 44 308
    R.19 38 BR-Y 19 208
    20 T.20 39 Y-SL 45 309
    R.20 40 SL-Y 20 209
    21 T.21 41 V-BL 46 310
    R.21 42 BL-V 21 210
    22 T.22 43 V-O 47 311
    R.22 44 O-V 22 211
    23 T.23 45 V-G 48 312
    R.23 46 G-V 23 212
    24 T.24 47 V-BR 49 313
    R.24 48 BR-V 24 213
    Ta b l e  5 - 3 9 .TN793 Analog Line Circuit Pack Pinout  — Continued
    Port SignalCross-Connect 
    Pin Color Amphenol Pin Backplane Pin
    Continued on next page 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-142 Connector and Cable Diagrams (Pinout Charts) 
    5
    Table 5-40. DS1 Interface Cable H600-307 (and C6C)
    50-Pin 15-Pin
    Pin Color Designation Pin Color Designation
    02 W-BL
    03 BL-W
    47 W-G LI (High)
    11 W-G LI (High)
    22 G-W LI
    03 G-W LI
    48 W-BR LO 09 W-BR LO
    23 BR-W LO (High)
    01 BR LO (High)
    49 W-SL LOOP2 06 W-SL LOOP2
    24 SL-W LOOP1 05 SL-W LOOP1
    All other p ins emp ty. 
    						