    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install Telecommunications Cabling 
    2-13 Label the Main Distribution Frame 
    2
    Label the Main Distribution Frame
    Fi g u re  2 - 6 shows the g rap hic  symb ols used  on lab els for the system, 
    c ross-c onnec tions, information outlets, and  c ab les. The lab els are c olor-c od ed  to 
    id entify system wiring :
    nGreen — To Central Offic e (CO)
    nPu r p le  — To system p orts
    nYe l l o w  — To auxiliary eq uip ment and  misc ellaneous system lead s
    nBlue — To information outlets
    nWh i t e  — From Main Distrib ution Frame to satellite loc ations (3-p air)
    Figure 2-6. Label Graphic Symbols and Nomenclature
    Eac h label id entifies 2 rows on the terminal b loc k. The up per half identifies the 
    row ab ove it and  the lower half id entifies the row b elow it. The labels are inserted  
    into the c lear p lastic  d esig nation strip s furnished  with the terminal b loc ks. The 
    strip  is snap p ed  in p lac e b etween the terminal b loc k rows. Lab el c od e numb er 
    1220A (c omc od e 103970000) c ontains all of the req uired  lab els.Figure Notes
    1. Write Floor or Build ing  Id entific ation on 
    Lab el as Req uired
    2. Cab inet
    3. Carrier
    4. Slot5. Information Outlet
    6. Site/Satellite Closet
    7. Tie Circ uit
    8. Floor
    9. Build ing
    r758422i LJK 050996 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install Telecommunications Cabling 
    2-14 Label the Main Distribution Frame 
    2 
    						
    							Accessing and Activating the System 
    3-1  
    3
    DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    3
    Accessing and Activating the System
    This c hapter c ontains p roc ed ures for installing the manag ement terminal and  
    b ring ing  the system up  to a “ no red  LEDs”  state. This c hap ter details how to:
    nAc cess the System
    nAc tivate the System
    nPower Up  the System
    nUse Sc reens and  Command s
    nAd minister the System
    nAd minister the Circ uit Pac ks
    nSet System Maintenanc e Parameters
    nAd minister Attend ant Console
    nSave Translations
    !CAUTION:
    To p revent unnec essary troub le tic kets, d o not enab le the system 
    alarms (Alarm Orig ination feature) until all installation and  
    ad ministration p roc ed ures are c ompleted . This c hap ter d esc rib es 
    b asic  system start-up  p roc ed ures only and  is not intend ed  to id entify 
    all system alarms or error c ond itions. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-2 Access the System 
    3
    Access the System
    To administer the DEFINITY ECS, you must be ab le to ac c ess the system. With 
    Release 7 and  later, the DEFINITY ECS no long er req uires a d ed ic ated  
    manag ement terminal, known as a system ad ministration terminal, or SAT. 
    Personal c omp uters and  tec hnic ian lap top s eq uip p ed  with DEFINITY Site 
    Ad ministration (DSA) or DEFINITY Network Ad ministration (DNA) software are the 
    p rimary supp ort ac c ess for system initialization, aftermarket ad d itions, and  
    ong oing  maintenanc e. For information on DSA or DNA, g o to
    http ://www.b c s.luc ent.c om/sales_market/d efinity. SAT is now an op tion.
    The following sections d escrib e 
    nInstalling  and  using DSA
    nConnec ting  a PC
    Installing and using DSA
    To install DSA, your PC or laptop  must meet the minimum req uirements 
    described in Tab le 3-1
    :
    NOTE:
    For information on DNA, refer to DEFINITY Network Ad ministration 
    Release 2 Installation and Configuration
    .
    Table 3-1. Minimum requirements to run DSA 
    Op erating  systems:
    MS Wind ows 95
    MS Wind ows 98
    MS Wind ows NT 4.0
    MS Wind ows 2000Pr o c e ss o r / RAM :
    486SL/66/16 MB
    Pentium/32 MB
    Pentium/64 MB
    Pentium-c lass 300 MHz/64 MB
    Grap hic s ad ap ter SVGA with minimum sc reen resolution of 800 x 
    600 
    Floppy disk drive 3-1/2 in. 1.44-MB floppy disk drive
    CD-ROM CD-ROM d rive (req uired  to install DSA from 
    CD)
    Available hard  d isk sp ac e A minimum of 100-MB free hard  d isk sp ac e is 
    req uired . The req uirement for d isk sp ac e 
    d ep end s on the size and  numb er of 
    c onfig uration d ata sets. 
    Continued on next page 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-3 Access the System 
    3
    To install DSA on your c omp uter, p lac e the DSA CD in the CD-ROM d rive and  
    follow the installation instructions. To start DSA or DNA, click on Start > 
    Programs > DEFINITY Site Administration
    . 
    DSA sup p orts SAT emulation, whic h is d irec tly eq uivalent to using  the SAT (see 
    Fi g u re  3 - 1
    ). DSA also sup p orts a whole rang e of other features, inc lud ing the 
    g rap hic ally enhanc ed  DEFINITY interfac e (GEDI) (see Fi g u re  3 -2
    ) and  Data 
    Imp ort. For more information refer to the Help , Guid ed  Tour, and Show Me 
    acc essed from the DSA Help menu.Pri n t e r p o rt St a n d a r d  PC  o r n e t w o r k  p r i n t e r  p o r t  is  re q u ir e d  
    for c onnec ting  to a p rinter to p rod uc e station 
    button labels. 
    Network ad ap ter May b e req uired  for network ac c ess to AUDIX 
    and  other network-c onnec ted  systems. 
    Free serial p orts One free serial port c ap able of 9600-b p s 
    op eration is req uired  for a c onnec tion to eac h 
    serial device (ADU, modem, data module) or 
    d irec t c onnec tion to a DEFINITY ECS.
    We rec ommend  that PCs have at least a 
    16550A UART or 16550A UART simulator 
    (c apab le of 56 kbp s DTE-sp eed  c onnec tions). 
    USB and internal modems should  emulate this 
    hardware.
    A sec ond  serial p ort is required  for 
    simultaneous c onnec tion to AUDIX throug h a 
    serial c onnec tion.
    Table 3-1. Minimum requirements to run DSA  — Continued
    Continued on next page 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-4 Access the System 
    3
    Figure 3-1. Typical DSA screen in SAT emulation mode
    Figure 3-2. Typical DSA screen in GEDI mode 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-5 Access the System 
    3
    Connecting a PC
    You c an c onnec t your PC or lap top  to the DEFINITY ECS R8si/R8c si/R8r either 
    d irec tly (50 ft [ 15 m]  or less) or remotely throug h a d ata mod ule or a mod em. 
    Connecting directly to the DEFINITY ECS
    You c an c onnec t d irec tly from the PC if it is 50 ft (15 m) or less from the 
    DEFINITY ECS. 
    1. Connec t the eq uip ment as shown in Fi g u re  3 - 3
    . See Tab le 3-2 for the 
    c onnec tions b y p latform. 
    !CAUTION:
    For a DC-p owered  system, install an EIA 116A Isolator (c omc od e 
    106005242) in series b etween the c ab le and  the TERM, DOT, or Terminal 
    Ac tive c onnec tor.
    Figure 3-3. A typical direct connection
    Figure Notes
    1 . D EFI N I TY EC S ( PPN  o n  R8 r )
    2. 50-ft (15-m) M25A c ab le 
    (RS-232)3. 9-to-25 pin ad ap ter if need ed
    4. Comp uter with DSA or DNA
    Table 3-2. PC connections by platform
    Reliability R8r R8si R8csi
    Standard Terminal Active TERM TERM
    Hig h/Critic al—DOT—
    cydfdr23 LJK 021800
    2
    31
    4 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-6 Access the System 
    3
    Connecting remotely to the DEFINITY ECS
    To c onnec t remotely to the system, you need  one of the following  p iec es of 
    hard ware:
    nConnec ting  throug h a data mod ule
    nConnec ting  b y analog  mod em to INADS p ort
    Connecting through a data module
    If more than 50 ft (15 m) from the DEFINITY ECS, you c an c onnec t the PC throug h 
    a data module. 
    1. Connec t the eq uip ment as shown in Fi g u re  3 - 4
    . 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-7 Access the System 
    3
    Figure 3-4. A typical remote connection using an 8400B (top) or 7400B 
    (bottom) data module
    NOTE:
    With a 7400A or 7400B+  data mod ule, use a 4-wire d ig ital line c irc uit p ac k. 
    With the 8400B+  d ata mod ule, use a 2-wire d igital line c irc uit p ac k.
    In p lac e of a 7400B+  d ata mod ule, you c an use a 7400A d ata mod ule. If 
    you do, set the 7400A to DCE Mod e.
    2. Wire the d ig ital line c irc uit p ac k to the wall jac k as follows:
    nFor a 7400B+ , wire to the sec ond and  third pair of the wall jac k.
    nFor an 8400B+ , wire to the first p air of the wall jac k. Figure Notes
    1. DEFINITY ECS
    2. Dig ital line c irc uit p ac k
    3. B25A 25-p air c able
    4. Main d istrib ution frame (MDF)
    5. 103A or Luc ent mod ular wall jac k
    6. 400B2 ad apter
    7. D6AP p ower c ord (8400B+  only)8. Data module power supply
    9. 7-ft (2-m) D8W mod ular cord
    10. Data mod ule (8400B+  [ top ]  or 
    7400B+  [ b ottom] )
    11. 50-ft (15-m) M25A c able (RS-232)
    12. Comp uter with DSA or DNA
    cydfdr08 KLC021500
    3
    3
    4
    4
    8
    5
    5
    1
    29
    1
    26
    7
    8
    9
    10
    10
    11
    11
    12
    12 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Accessing and Activating the System 
    3-8 Access the System 
    3
    Setting the Data Module to DCE Mode
    1. Cyc le the p ower to the d ata mod ule. The unit p erforms a self test and  
    displays its operating mode.
    2. Observe the d isp lay.
    a. If the d isp lay reads DCE mod e, p roc eed  to the next sec tion.
    b . If the d isp lay reads DTE mod e, c omp lete the following  step s:
    1. Remove the p ower c ord  from the unit.
    2. Remove the c over from the top  rear of the unit.
    3. Remove the mod e selec t c irc uit b oard  and  turn it around .
    4. Rep lac e the c over.
    5. Connect the power c ord.The unit performs a self test.
    NOTE:
    The p ower LED must b e stead y on. If the p ower LED is b linking, the d ata 
    mod ule is not c ommunic ating  with the DEFINITY ECS. Chec k the wiring  at 
    the MDF, wall jac ks, and  d ata mod ule.
    Adding a Data Module to the Switch
    1. Add the data module to the switch by entering add data-module
     number 
    or add data-module next
    .
    2. In the Type:
     field , typ e pdm
     and press 
    En te r.
    3. In the Port:
     field , typ e the loc ation of the d ig ital line c irc uit p ac k 
    connec ted to the data module (for example 01A1503).
    4. If system ac c ess p orts and  hunt g roup s have not b een set up , set them 
    up . Refer to 
    DEFINITY ECS Release 8 Ad ministrator’s Guid e.
    Testing Hardware Connections
    In the following  tab le, find  your d ata mod ule and  follow the instruc tions for testing  
    and  troub leshooting  it. 
    						
    All Lucent Technologies manuals Comments (0)