Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install Telecommunications Cabling 2-13 Label the Main Distribution Frame 2 Label the Main Distribution Frame Fi g u re 2 - 6 shows the g rap hic symb ols used on lab els for the system, c ross-c onnec tions, information outlets, and c ab les. The lab els are c olor-c od ed to id entify system wiring : nGreen — To Central Offic e (CO) nPu r p le — To system p orts nYe l l o w — To auxiliary eq uip ment and misc ellaneous system lead s nBlue — To information outlets nWh i t e — From Main Distrib ution Frame to satellite loc ations (3-p air) Figure 2-6. Label Graphic Symbols and Nomenclature Eac h label id entifies 2 rows on the terminal b loc k. The up per half identifies the row ab ove it and the lower half id entifies the row b elow it. The labels are inserted into the c lear p lastic d esig nation strip s furnished with the terminal b loc ks. The strip is snap p ed in p lac e b etween the terminal b loc k rows. Lab el c od e numb er 1220A (c omc od e 103970000) c ontains all of the req uired lab els.Figure Notes 1. Write Floor or Build ing Id entific ation on Lab el as Req uired 2. Cab inet 3. Carrier 4. Slot5. Information Outlet 6. Site/Satellite Closet 7. Tie Circ uit 8. Floor 9. Build ing r758422i LJK 050996
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install Telecommunications Cabling 2-14 Label the Main Distribution Frame 2
Accessing and Activating the System 3-1 3 DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 3 Accessing and Activating the System This c hapter c ontains p roc ed ures for installing the manag ement terminal and b ring ing the system up to a “ no red LEDs” state. This c hap ter details how to: nAc cess the System nAc tivate the System nPower Up the System nUse Sc reens and Command s nAd minister the System nAd minister the Circ uit Pac ks nSet System Maintenanc e Parameters nAd minister Attend ant Console nSave Translations !CAUTION: To p revent unnec essary troub le tic kets, d o not enab le the system alarms (Alarm Orig ination feature) until all installation and ad ministration p roc ed ures are c ompleted . This c hap ter d esc rib es b asic system start-up p roc ed ures only and is not intend ed to id entify all system alarms or error c ond itions.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-2 Access the System 3 Access the System To administer the DEFINITY ECS, you must be ab le to ac c ess the system. With Release 7 and later, the DEFINITY ECS no long er req uires a d ed ic ated manag ement terminal, known as a system ad ministration terminal, or SAT. Personal c omp uters and tec hnic ian lap top s eq uip p ed with DEFINITY Site Ad ministration (DSA) or DEFINITY Network Ad ministration (DNA) software are the p rimary supp ort ac c ess for system initialization, aftermarket ad d itions, and ong oing maintenanc e. For information on DSA or DNA, g o to http ://www.b c s.luc ent.c om/sales_market/d efinity. SAT is now an op tion. The following sections d escrib e nInstalling and using DSA nConnec ting a PC Installing and using DSA To install DSA, your PC or laptop must meet the minimum req uirements described in Tab le 3-1 : NOTE: For information on DNA, refer to DEFINITY Network Ad ministration Release 2 Installation and Configuration . Table 3-1. Minimum requirements to run DSA Op erating systems: MS Wind ows 95 MS Wind ows 98 MS Wind ows NT 4.0 MS Wind ows 2000Pr o c e ss o r / RAM : 486SL/66/16 MB Pentium/32 MB Pentium/64 MB Pentium-c lass 300 MHz/64 MB Grap hic s ad ap ter SVGA with minimum sc reen resolution of 800 x 600 Floppy disk drive 3-1/2 in. 1.44-MB floppy disk drive CD-ROM CD-ROM d rive (req uired to install DSA from CD) Available hard d isk sp ac e A minimum of 100-MB free hard d isk sp ac e is req uired . The req uirement for d isk sp ac e d ep end s on the size and numb er of c onfig uration d ata sets. Continued on next page
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-3 Access the System 3 To install DSA on your c omp uter, p lac e the DSA CD in the CD-ROM d rive and follow the installation instructions. To start DSA or DNA, click on Start > Programs > DEFINITY Site Administration . DSA sup p orts SAT emulation, whic h is d irec tly eq uivalent to using the SAT (see Fi g u re 3 - 1 ). DSA also sup p orts a whole rang e of other features, inc lud ing the g rap hic ally enhanc ed DEFINITY interfac e (GEDI) (see Fi g u re 3 -2 ) and Data Imp ort. For more information refer to the Help , Guid ed Tour, and Show Me acc essed from the DSA Help menu.Pri n t e r p o rt St a n d a r d PC o r n e t w o r k p r i n t e r p o r t is re q u ir e d for c onnec ting to a p rinter to p rod uc e station button labels. Network ad ap ter May b e req uired for network ac c ess to AUDIX and other network-c onnec ted systems. Free serial p orts One free serial port c ap able of 9600-b p s op eration is req uired for a c onnec tion to eac h serial device (ADU, modem, data module) or d irec t c onnec tion to a DEFINITY ECS. We rec ommend that PCs have at least a 16550A UART or 16550A UART simulator (c apab le of 56 kbp s DTE-sp eed c onnec tions). USB and internal modems should emulate this hardware. A sec ond serial p ort is required for simultaneous c onnec tion to AUDIX throug h a serial c onnec tion. Table 3-1. Minimum requirements to run DSA — Continued Continued on next page
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-4 Access the System 3 Figure 3-1. Typical DSA screen in SAT emulation mode Figure 3-2. Typical DSA screen in GEDI mode
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-5 Access the System 3 Connecting a PC You c an c onnec t your PC or lap top to the DEFINITY ECS R8si/R8c si/R8r either d irec tly (50 ft [ 15 m] or less) or remotely throug h a d ata mod ule or a mod em. Connecting directly to the DEFINITY ECS You c an c onnec t d irec tly from the PC if it is 50 ft (15 m) or less from the DEFINITY ECS. 1. Connec t the eq uip ment as shown in Fi g u re 3 - 3 . See Tab le 3-2 for the c onnec tions b y p latform. !CAUTION: For a DC-p owered system, install an EIA 116A Isolator (c omc od e 106005242) in series b etween the c ab le and the TERM, DOT, or Terminal Ac tive c onnec tor. Figure 3-3. A typical direct connection Figure Notes 1 . D EFI N I TY EC S ( PPN o n R8 r ) 2. 50-ft (15-m) M25A c ab le (RS-232)3. 9-to-25 pin ad ap ter if need ed 4. Comp uter with DSA or DNA Table 3-2. PC connections by platform Reliability R8r R8si R8csi Standard Terminal Active TERM TERM Hig h/Critic al—DOT— cydfdr23 LJK 021800 2 31 4
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-6 Access the System 3 Connecting remotely to the DEFINITY ECS To c onnec t remotely to the system, you need one of the following p iec es of hard ware: nConnec ting throug h a data mod ule nConnec ting b y analog mod em to INADS p ort Connecting through a data module If more than 50 ft (15 m) from the DEFINITY ECS, you c an c onnec t the PC throug h a data module. 1. Connec t the eq uip ment as shown in Fi g u re 3 - 4 .
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-7 Access the System 3 Figure 3-4. A typical remote connection using an 8400B (top) or 7400B (bottom) data module NOTE: With a 7400A or 7400B+ data mod ule, use a 4-wire d ig ital line c irc uit p ac k. With the 8400B+ d ata mod ule, use a 2-wire d igital line c irc uit p ac k. In p lac e of a 7400B+ d ata mod ule, you c an use a 7400A d ata mod ule. If you do, set the 7400A to DCE Mod e. 2. Wire the d ig ital line c irc uit p ac k to the wall jac k as follows: nFor a 7400B+ , wire to the sec ond and third pair of the wall jac k. nFor an 8400B+ , wire to the first p air of the wall jac k. Figure Notes 1. DEFINITY ECS 2. Dig ital line c irc uit p ac k 3. B25A 25-p air c able 4. Main d istrib ution frame (MDF) 5. 103A or Luc ent mod ular wall jac k 6. 400B2 ad apter 7. D6AP p ower c ord (8400B+ only)8. Data module power supply 9. 7-ft (2-m) D8W mod ular cord 10. Data mod ule (8400B+ [ top ] or 7400B+ [ b ottom] ) 11. 50-ft (15-m) M25A c able (RS-232) 12. Comp uter with DSA or DNA cydfdr08 KLC021500 3 3 4 4 8 5 5 1 29 1 26 7 8 9 10 10 11 11 12 12
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Accessing and Activating the System 3-8 Access the System 3 Setting the Data Module to DCE Mode 1. Cyc le the p ower to the d ata mod ule. The unit p erforms a self test and displays its operating mode. 2. Observe the d isp lay. a. If the d isp lay reads DCE mod e, p roc eed to the next sec tion. b . If the d isp lay reads DTE mod e, c omp lete the following step s: 1. Remove the p ower c ord from the unit. 2. Remove the c over from the top rear of the unit. 3. Remove the mod e selec t c irc uit b oard and turn it around . 4. Rep lac e the c over. 5. Connect the power c ord.The unit performs a self test. NOTE: The p ower LED must b e stead y on. If the p ower LED is b linking, the d ata mod ule is not c ommunic ating with the DEFINITY ECS. Chec k the wiring at the MDF, wall jac ks, and d ata mod ule. Adding a Data Module to the Switch 1. Add the data module to the switch by entering add data-module number or add data-module next . 2. In the Type: field , typ e pdm and press En te r. 3. In the Port: field , typ e the loc ation of the d ig ital line c irc uit p ac k connec ted to the data module (for example 01A1503). 4. If system ac c ess p orts and hunt g roup s have not b een set up , set them up . Refer to DEFINITY ECS Release 8 Ad ministrator’s Guid e. Testing Hardware Connections In the following tab le, find your d ata mod ule and follow the instruc tions for testing and troub leshooting it.