    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Option Switch Settings 
    A-1 Data Module Option Switch Settings 
    A
    DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    A
    Option Switch Settings
    Some of the interfac e units used  b etween the system and other typ es of 
    eq uip ment require spec ific  op tion switc h settings for eac h ap p lic ation. This 
    sec tion lists the setting s req uired for d ata mod ules, mod ems, printers, and  so 
    forth. Refer to the user’s g uid e for eac h typ e of eq uip ment for information on how 
    to loc ate and  set the option switc hes. 
    Data Module Option Switch Settings
    DCS Switch Settings
    The Distributed  Communic ations System (DCS) for a system is sometimes 
    c onnec ted  to the system throug h the TN790B Proc essor Interfac e c irc uit p ac k or 
    a TN794 Network Control/Pac ket Interfac e (Net/Pkt) c irc uit p ac k. The first c irc uit 
    c an b e c onnec ted direc tly to the DCS throug h the p roc essor interfac e (PI) 
    c onnec tor on the rear of the c ontrol c arrier.
    Any of the remaining three c irc uits on the proc essor interfac e used  to sup p ort the 
    Distrib uted  Communic ations System (DCS) must b e c onnec ted  throug h a d ata 
    mod ule serving  as the interfac e link. The op tion setting s for a 7400A Data Mod ule 
    are shown in Ta b l e  A - 1
    . Refer to Fi g u re  A - 1 for the loc ation of the switc hes.
    NOTE:
    The options for the 7400A and  7400C Data Mod ules are set from the front 
    p anel interfac e. For the 7400A, refer to 
    7400A Data Mod ule User’s Manual, 
    555-020-706. For the 7400C, refer to 
    DEFINITY Communic ations System 
    Hig h Sp eed  Link User’s Guid e
    , 555-020-711. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-2 Data Module Option Switch Settings 
    A
    Figure A-1. DIP Switch Locations
    1. Remove the top  c over from the data mod ule. Refer to Chap ter 5, ‘‘Install 
    and  Wire Telep hones and  Other Eq uip ment’’.
    2. Switc hes 1, 5, and 8 are the only switches to be set. Refer to Ta b l e  A - 1
     for 
    the op tion switc h settings. 
    Figure Notes
    1. Data Mod ule (7400A Shown) 2. DIP Switc h
    Table A-1. Data Module Option Switch Settings
    DIP Switch Function  Setting
    1With Phone
    Without PhoneON
    OFF
    5 Data Metering  
    No Data MeteringON
    OFF
    8 Make Busy on Loc  Loop
    No Make Busy on Loc  LoopON
    OFF
    2, 3, 4, 6, and  7 OFF
    1
    2
    DTE
    PO WER
    TESTDATA
    METERING
    7400B Data Mod ule
    AA CD RD SD TR OHCHECK
    SPEED
    DATA
    12345678
    O
    N 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-3 7400D Data Module Option Settings 
    A
    7400D Data Module Option Settings
    The op tion setting s shown in Ta b l e  A - 2 are for the Answer Only interfac e and  are 
    set from the front panel interfac e. Set only the d esired  sp eed  of the 7400D. All 
    other d efault settings c an b e used .
    Refer to “ Set 7400 D”  Op tions on p ag e B-4 to set the sp eed . 
    NOTE:
    It is rec ommended  that CI and  CH b e set to ON, and  DCD and  DSR b e set 
    to normal. This allows log in information to b e d isp layed  on the sc reen 
    without having  to send  a c arriage return c harac ter.
    Table A-2. 7400 Series Data Module Options (Answer Only Interface)
    Set Option Display Abbreviation Possible Values Default
    Set  30 0  SPEED ? 3 00 O N ,  O FF ON
    Set  12 0 0 SPEED ? 1 20 0 O N ,  O FF ON
    Set  24 0 0 SPEED ? 2 40 0 O N ,  O FF ON
    Set  48 0 0 SPEED ? 4 80 0 O N ,  O FF ON
    Set  96 0 0 SPEED ? 9 60 0 O N ,  O FF ON
    Set 19200 SPEED? 19200 ON, OFF ON
    Set  A N SWER? A N S A U TO,  MA N U A L AU TO
    Set CI LEAD? CI ON, OFF OFF
    Set CH LEAD? CH ON, OFF OFF
    Set CTS LEAD? CTS NORMAL, ON ON
    Set DCD LEAD? DCD NORMAL, ON ON
    Set  D SR L EA D ? D SR N ORMA L ,  O N ON
    Set DTR DETECT? DTR 0, 10, 20, 30, 50, 100 MSEC 50
    Set DTR LEAD? DTR EIA STANDARD, IGNORE EIA STANDARD
    Set LL LEAD? LL ON, OFF OFF
    Set REMOTE LOOP? REMLOOP GRANT, DENY GRANT
    Set RI LEAD? RI CYCLE, ON ON
    Set RL LEAD? RL ON, OFF OFF
    Set  SIG LS D I SC ? SI GL S D I SC O N ,  O FF ON
    Set  TI M IN G? TI MI N G I N TERN A L,  EXTERN A L IN T
    Se t  TM  L EA D ? TM O N ,  O FF O FF 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-4 7400D Data Module Option Settings 
    A
    Set 7400D Options
    The following step s are an examp le of how to c hang e the d efault setting  of 9600 
    to the c ustom setting  of 19200.
    NOTE:
    If the link is b etween a Release 8r and  a CMS, set the 7400D to 19200. If 
    the link is b etween any other system and  a CMS, leave the sp eed  of the 
    7400D set at 9600.
    1. From the HOME sc reen, p ress NEXT/NO
     until SET OPTIONS ?
     is 
    d isp layed .
    2. Press ENTER/YES
     to stay in the SET OPTIONS ?
     menu.
    3. Press NEXT/NO
     until SET 9600 SPEED ?
     is d isp layed .
    4. Press ENTER/YES
     when SET 9600 SPEED ?
     is displayed.
    5. Press NEXT/NO
     when 9600 = ON ?
     is d isp layed .
    6. Press ENTER/YES
     when 9600 -> OFF ?
     is displayed.
    7. Press ENTER/YES
     when CONTINUE ?
     is d isp layed .
    8. Press ENTER/YES
     when SET 19200 SPEED ?
     is displayed.
    9. Press NEXT/NO
     when 19200 = OFF ?
     is d isp layed .
    10. Press ENTER/YES
     when 19200 -> ON ?
     is displayed.
    11. Press NEXT/NO
     when CONTINUE ?
     is d isp layed .
    12. Press ENTER/YES
     when 19200 -> ON ?
     is displayed.
    13. Press ENTER/YES
     when SAVE CHANGES ?
     is displayed.
    NOTE:
    Th e  SET OPTIONS ?
     menu c annot b e terminated  if all sp eed s are 
    set to off. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-5 Add Pooled Modem 
    A
    Add Pooled Modem
    Mod em Pooling  sup p orts 2 types of c onversion resourc es: integrated  and  
    combined. 
    The integrated type requires a TN758 Pooled Modem circuit pack for each 2 
    c onversion resourc es p rovid ed.
    The c omb ined  typ e requires a p ort on a TN754B Dig ital Line c irc uit p ac k and  a 
    p ort on either an 8-p ort TN742, TN769; a 16-p ort TN746B; or a 24-port TN793/B, 
    TN2793/B Analog  Line c irc uit p ac k for eac h c onversion resourc e p rovid ed.
    The p ooled  mod em req uires a Luc ent WP90110 L7
     power supply. Although an 
    integ rated  c onversion resourc e c an use either the L5 or L7, the c ombined only 
    works with an L7.
    !CAUTION:
    The L5 and  L7 p ower supp lies look id entic al. Chec k the list numb er on the 
    power supply before installing.
    1. Determine the p ort assig nment of the c irc uit p ac ks to b e ad d ed  (if 
    req uired ).
    2. Install the ap p rop riate c irc uit pac ks in assigned  c arrier slot (if req uired ).
    3. For Paradyne 3800 Series mod ems:
    a. Type AT&F&D2&S4\D3S2=128x7V2S7=60S85=1
     and  p ress 
    En te r. 
    b. Type ATY0S10=100S78=2M0E0\N1&W
     and  p ress 
    En t e r.
    4.For other typ es of mod ems, refer to the vend or’s d oc umentation. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-6 Add Pooled Modem 
    A
    Settings for Modem Connected to Data Module
    1. Type add data-module next
     and press En t e r.
    2. Type pdm
     in the Type
     field .
    3. Type x
     in the Port
     field.
    4. Type dte
     in the Connected to
     field and press 
    En te r.
    5. Type add station next
     and press 
    En t e r.
    6. Type 2500
     in the Type
     field.
    7. Type x
     in the Port
     field.
    8. Type n
     in the Tests
     field  and  p ress 
    En te r.
    9. Type add modem-pool next
     and  p ress 
    En te r.
    10. Typ e combined
     in the Group Type
     field.
    11. Typ e 5
     in the Hold Time (min)
     field .
    12. Typ e two-way
     in the Direction
     field .
    13. Typ e 9600
     in the Speed
     field.
    14. Typ e Full
     in the Duplex
     field .
    15. Typ e async
     in the Synchronization
     field .
    16. Typ e the p ort p air assig nments in the Analog
     and Digital
     fields and  
    p ress 
    En t e r.
    Settings for Modem Connected to the Data 
    Terminal Equipment (DTE)
    1. Type add station next
     and press En t e r.
    2. Type 2500
     in the Type
     field.
    3. Typ e the p ort assig nment in the Port
     field  and  p ress 
    En t e r. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-7 Add Pooled Modem 
    A
    7400A and 7400B Option Settings
    Determine if the 7400A or 7400B will b e interfac ing with D-lead  modems or 
    attention c ontrol mod ems. Use Ta b l e  A - 3
     to interfac e with either modem. You c an 
    set op tions for the 7400B throug h a d umb  terminal. 
    NOTE:
    1. Set sp eed  to matc h remote mod em. At least one sp eed  must b e set ON.
    NOTE:
    2. Set to matc h remote mod em.
    Table A-3. Options for D-Lead and Attention Control Modems
    Set Option Display Option D-Lead 
    SettingsAttention 
    Control Settings
    Set 300 Sp eed ? 300 Note 1 Note 1
    Set 1200 Speed ? 1200 Note 1 Note 1
    Set 2400 Speed ? 2400 Note 1 Note 1
    Set 4800 Speed ? 4800 Note 1 Note 1
    Set 9600 Speed ? 9600 Note 1 Note 1
    Set 19200 Sp eed ? 19200 Note 1 Note 1
    Set AT Control? AT OFF ON
    Set CI Lead ? CI Note 2 Note 2
    Set CI2 Lead ? CI2 Note 2 Note 2
    Set CH Lead ? CH Note 2 Note 2
    Set CH2 Lead ? CH2 Note 2 Note 2
    Set LL Lead ? LL Note 2 Note 2
    Set REMOTE Loop ? REMLOOP Grant Grant
    Set RL Lead ? RL Note 2 Note 2
    Se t  SI G L S D is c ? SI GL S D I SC ON ON
    Set TM Lead ? TM Note 2 Note 2 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-8 Printer Option Settings 
    A
    Printer Option Settings
    Printers c an b e used  with a manag ement terminal as journal p rinters for the 
    hosp itality feature and  also as an outp ut devic e for Call Detail Rec ord ing  (CDR). 
    A 572 printer c an func tion as a CDR d evic e, system p rinter, or journal p rinter. 
    The op tions are set with func tion keys rather than DIP switc hes. Fig ure A -2
     shows 
    the arrang ement of the func tion keys on the p rinter c ontrol p anel.
    Figure A-2. Control Panel for 572 Printer
    1. Load  the p rinter with p ap er and  turn the p ower off (Callout 1).
    2. Simultaneously p ress and  hold  the Print Quality
     and  On Line
     b uttons. 
    Press the Power On
     b utton. Release all three b uttons. The p rinter is now in 
    set-up  mod e and  it p rints c urrent setting s:
    If the p rinter is used with a management terminal, CDR, or as a Journal 
    p rinter, set the op tions as shown in Ta b l e  A - 4
    . If the p rinter is used  as the 
    system p rinter, set the op tions as shown in Ta b l e  A - 5
    .
    3. Use Line Feed
     or Form Feed
     to step  throug h the op tions for the func tion.
    4. Press On Line
    . This ac tivates the menu for the func tion. Use Line Feed
     
    and  Form Feed
     to step  throug h the op tions for the func tion.
    5. When a d esired  op tion is loc ated , p ress Print Quality
    . Eac h time an op tion 
    is set, the setting  is p rinted . Rep eat for eac h op tion to be set.
    6. When finished , p ress Print Quality
    . The p rinter c hang es to normal mod e. Figure Notes
    1. Power On Button
    2. Alarm Button
    3. Print Quality Button4. On Line Button
    5. Line Feed  Button
    6. Form Feed  Button
    Power
    OnAlarm Print
    QualityOn
    LineLine
    FeedFo r m
    Feed
    345162 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-9 Printer Option Settings 
    A
    Table A-4. 572 Printer Used with Management Terminal 
    Function Function Name Menu Menu Status
    01 FORM LENGTH 09 11
    02 LPI 01 6
    03 CPI 01 10
    04 LQ or NLQ 01 LQ
    05 BUZZER 01 ON
    06 FONT 02 FONTCART
    07 RESOLUTION 01 144
    1 1 B U FFER 0 2 N - L I N E
    13 PW ON MODE 01 ON-LINE
    14 DIRECTION 01 B1-DIR.1
    15 BUFF FULL 02 LF +  CR
    1 6 P. E. 0 1 AC TI VE
    17 A UTO  CA RRIA GE RETURN ( CR) 01 CR +  LF
    18 ZERO 01 0
    22 AUTO LINE FEED 01 CR ONLY
    311’’ SKIP 01 OFF
    3 2 C H A R. SET ( GO ,  GL ) 0 2 U SA
    33 CHAR.SET (G1, GR) 01 UK
    34 CHAR SET (G2) 03 GE
    35 CHAR SET (G3) 07 LINE DRAWING
    81 OFF-LINE STATE 01 ALL RECEIVE
    82 DSR 02 OFF
    8 3 REQU EST TO  SEN D  ( RTS) TI M I N G 0 1 RTS
    84 CD 02 OFF
    8 5 C L EA R TO  SEN D  ( C TS) 0 2 O FF
    91 OVER RUN 02 256
    92 DATA BIT 02 8
    93 PROTOCOL 03 XON/XOFF
    94 STOP BIT 01 1
    95 PARITY 01 NONE
    96 PBS (matc hes c onnec ted  d evic e) 01 9600
    Continued on next page 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Option Switch Settings 
    A-10 Printer Option Settings 
    A
    Table A-5. 572 Printer used as System Printer 
    Function Function Name Menu Menu Status
    01 FORM LENGTH 09 11
    02 LPI 01 6
    03 CPI 01 10
    04 LQ or NLQ 01 LQ
    05 BUZZER 01 ON
    06 FONT 02 FONTCART
    07 RESOLUTION 01 144
    11 BUFFER 02 N-LINE
    13 PW ON MODE 01 ON-LINE
    14 DIRECTION 01 B1-DIR.1
    15 BUFF FULL 02 LF +  CR
    16 P.E. 01 ACTIVE
    17 AUTO CARRIAGE RETURN (CR) 01 CR +  LF
    18 ZERO 01 0
    22 AUTO LINE FEED 01 CR ONLY
    311’’ SKIP 01 OFF
    32 CHAR.SET (GO, GL) 02 USA
    33 CHAR.SET (G1, GR) 01 UK
    34 CHAR SET (G2) 03 GE
    35 CHAR SET (G3) 07 LINE DRAWING
    81 OFF-LINE STATE 01 ALL RECEIVE
    82 DSR 02 OFF
    8 3 REQ U EST TO  SEN D  ( RTS)  TI M I N G 0 1 RTS
    84 CD 02 OFF
    8 5 C L EAR TO  SEN D  (C TS) 0 2 OFF
    91 OVER RUN 02 256
    92 DATA BIT 02 8
    93 PROTOCOL 03 XON/XOFF
    94 STOP BIT 01 1
    95 PARITY 01 NONE
    96 PBS 04 1200 
    						
    All Lucent Technologies manuals Comments (0)