Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-113 Add IP Interface Assembly 
    5
    Figure 5-36. TN802B IP Interface faceplate
    NOTE:
    To p rop erly seat the c irc uit p ac k, p ush firmly on the front of the fac ep late 
    until the latc h reac hes the b ottom rail of the c arrier. Then c lose the latc h 
    until it is fully eng ag ed .
    1. Insert the TN802B IP Interfac e into the rig htmost of the three slots you 
    reserved  for it (see Fig ure 5-37
    ).
    When you p lug  in the TN802B IP Interfac e, the c irc uit p ac k starts to b oot 
    and  the LCD read s PC Boot 
    then after ab out 3 to 4 minutes it c hang es to 
    IP TRK *
    , the default mod e. Figure Notes
    1. LCD d isp lay
    2. Reset b utton (rec essed )
    3. Red  b oard  status LED4. PCMCIA c ard slot
    5. Yellow PCMCIA d isk-in-use LED
    1
    2
    3
    4
    5
    fpdfmapd KLC 030899 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-114 Add IP Interface Assembly 
    5
    Figure 5-37. J58890MA-1 L30 IP Interface Assembly
    Test the Modem
    1. Check for dial tone.
    2. Contac t Luc ent Tec hnolog ies Customer Sup p ort and  ask a rep resentative 
    to d ial into your IP Interfac e server. 
    Administer the IP Interface
    Ad minstration is d one either loc ally or remotely. If ad ministered  loc ally, p roc eed  
    with the following  ad minstration step s on the attac hed  keyb oard , mouse, and  
    monitor. If administered  remotely, c all your servic e rep resentative to start the 
    p roc ess.
    456
    789
    1
    0
    1
    11
    21
    3
    1
    41
    51
    6
    indfmapd KLC 031299 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-115 Add IP Interface Assembly 
    5
    Administration Steps
    1. Log in as craft
    .
    2. Type change circuit-pack
     and  p ress 
    En te r.
    3. Chec k the Cod e c olumn to see if the slots ab ove the TN802B say 
    DSMAPD or MEDPRO.
    .
    4. If MEDPRO, g o to the entry just ab ove the TN802B that says MEDPRO.
    5. Type DSMAPD, and press 
    En te r. Chang ing the one entry automatic ally 
    c hang es the entry ab ove it. If it is in IP Trunk mode, you g et the following 
    error message:
    MedPro type requires TN802 with application. Type 
    MEDPRO on circuit-packs form.
    Log onto the TN802B Interface Server 
    If administered  remotely throug h p c ANYWHERE:
    1. Dial in to the server through pcANYWHERE using the dialup number 
    supplied. 
    2. Clic k on the p c ANYWHERE Remote Host Computer b utton on the toolb ar 
    to send  
    CTRL ALT DEL to the host.
    3. Type administrator
     in the User Name
     field .
    4. Type iptrunk
     in the Password
     field  and  c lic k OK
    . 
    5. After log g ing  on for the first time, c hang e the ad ministrator p assword and , 
    if d esired , the user name, to ensure sec urity. See your Wind ows NT server 
    d oc umentation for d etails.
    change circuit-packs                                            Page   1 of   5 
                                  CIRCUIT PACKS                                     
            Cabinet: 1                            Carrier: A
                                             Carrier Type: processor        
     Slot Code  Sf Mode   Name               Slot Code  Sf Mode   Name
    11: DSMAPD RESERVED-IP
    01: TN754  DIGITAL LINE  12: DSMAPD  RESERVED-IP
    02: TN758  POOLED MODEM  13: TN802  B  MAPD BOARD
    03: TN2144  ANALOG LINE  14: 
    04: TN746  B  ANALOG LINE  15: 
    05 16:         
    06: TN771  C  MAINTENANCE/TEST  
    07: TN464  F  DS1 INTERFACE     
    08: TN2140  E&M TIE TRUNK     
    09: TN767  E  DS1 INTERFACE     
    10: TN799  B  CONTROL-LAN       
      # indicates circuit pack conflict. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-116 Add IP Interface Assembly 
    5
    If administered  loc ally on a monitor, keyb oard, and  mouse:
    1. Press 
    CTRL, ALT, and  DEL simultaneously.
    2. Type administrator
     in the User Name
     field .
    3. Type iptrunk
     in the Password
     field  and  c lic k OK
    . 
    4. After log g ing  on for the first time, c hang e the ad ministrator p assword and , 
    if d esired , the user name, to ensure sec urity. See your Wind ows NT server 
    d oc umentation for d etails.
    A-Law versus Mu-Law
    For systems using  A-Law c omp and ing , an ad d itional p roc ed ure is nec essary. 
    On the SAT:
    1. Busyout the trunk g roup  assoc iated  with the IP trunk b y typing  busyout 
    board 
    UUCSS and  p ressing  En t e r.
    In the Wind ows interfac e to TN802B:
    1. Click on Control Panel > Services.
    2. Highlight IP Trunk Service
    , then c lic k on Stop
    .
    3. In the lower left-hand  c orner, rig ht-c lic k Start >  Exp lore.
    4. Go to the c : d rive and  c lic k on its, then b in.
    5. Double-c lic k on the its.ini file to op en it in Notep ad .
    6. Und er the [ Med iaLib ]  sec tion, g o to COMPANDING= MLAW. Chang e 
    MLAW
     to ALAW
    .
    7. Click on File > Save
     to save the file.
    8. Click on File > Exit
     to exit Notep ad .
    9. Click on Control Panel > Services.
    10. Highlight IP Trunk Service
    , then c lic k on Start
    .
    NOTE:
    Do not selec t Startup .
    After servic e has started , g o to the SAT:
    1. Release the trunk g roup  assoc iated  with the IP trunk b y typing  release 
    board
     
    UUCSS and  p ressing  En t e r. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-117 Add IP Interface Assembly 
    5
    Assign Server and Domain Names
    The Windows NT server identifies servers using a server name plus a domain 
    name that loc ates the named  server in a p artic ular p art of the network. The 
    TN802B IP Interfac e is ship p ed  with generic  server and  d omain names. Assig n 
    rep lac ement names that are meaning ful within your network. 
    1. Click on My Computer > Control Panel > Network
    .
    2. Selec t the Identification
     tab , then c lic k Change
    .
    3. Typ e the new server name in the Computer Name 
    field .
    4. Typ e the new d omain name in the Domain
     field and  c lic k OK > OK > 
    Close
    .
    5. When p romp ted  to reb oot the c omp uter, selec t one of the following  
    op tions:
    nNo
     if you have not assigned  IP ad d resses then g o to ‘‘Assig n an IP 
    Address’’
    nYe s
     if you have assigned  IP ad dresses. 
    Assign an IP Address
    1. Click on My Computer > Control Panel > Network
    .
    2. Click the Protocols
     tab .
    3. Select TCP/IP Protocol 
    from the list.
    4. Click the Properties
     op tion in the Network wind ow.  
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-118 Add IP Interface Assembly 
    5
    5. Verify that the Adapter
     drop  d own menu lists 2 DEC Ethernet ad ap ters.
    !CAUTION:
    Do not c hange any setting s on the ad ap ter lab eled  [ 1]  for any 
    reason.
    6. Selec t the DEC Ethernet ad ap ter lab eled  [ 2] . 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-119 Add IP Interface Assembly 
    5
    7. Typ e a valid  IP ad d ress for the IP Interfac e server in the IP Address:
     
    field .
    8. Typ e the ap p rop riate sub net mask in the Subnet Mask:
     field. 
    NOTE:
    Not all networks req uire step s 9 throug h 18. Chec k with the loc al 
    network ad ministrator to determine whic h are req uired .
    9. If you use g ateways, type the IP ad d ress of the d efault g ateway for the IP 
    Interfac e server in the Default Gateway:
     field.
    10. Clic k on the DNS tab  and  verify that the d omain DNS server is c orrec t. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-120 Add IP Interface Assembly 
    5
    11. Typ e d omain name in the Domain
     field .
    12. If using  DNS, c lic k 
    Add  under the DNS Service Search Order
     field  and 
    type its IP ad d ress.
    13. Clic k on the WINS Ad dress tab . 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-121 Add IP Interface Assembly 
    5
    14. Make sure the [ 2]  DEC shows in the Adapter
     field.
    15. If WINS server is availab le, typ e its IP ad d ress in the Primary WINS 
    Server
     field .
    16. If DNS is availab le, selec t Enable DNS for Windows Resolution
    .
    17. If the network uses an imp orted LMHOSTS file, selec t Enable LMHOSTS 
    Lookup 
    and Import LMHOSTS
     and c lic k OK
    .
    18. If the following  d ialog  b ox op ens, c lic k Ye s
    :
    At least one of the adapter cards has an empty primary 
    WINS address. Do you want to continue?
    19. Clic k the Bindings
     tab  to effec t the c hang es.
    NetBIOS Interface, Server, and Workstation should now be enabled. If any 
    are d isab led  (a red  c irc le with a line throug h it), review the p revious 
    network-c onfig uration step s for omissions or errors.
    20. Clic k Close
    . 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-122 Add IP Interface Assembly 
    5
    If administered  remotely throug h p c ANYWHERE:
    21. Clic k on the p c ANYWHERE Restart Host Comp uter b utton on the toolb ar 
    to restart the c omputer.
    If administered  loc ally on a monitor, keyb oard, and  mouse:
    21. Clic k Ye s
     in the d ialog  b ox to restart the c omp uter. 
    !WARNING:
    When c onnec ted  remotely via p c ANYWHERE, only use the p c ANYWHERE 
    Restart Host Computer b utton on the toolb ar to restart Wind ows NT.
    Check Network Services
    When the server restarts, make sure that the req uired  network servic es have 
    started c orrec tly. If you see an error d ialog  b ox, then the network servic es d id  not 
    start c orrec tly. Also, c hec k the NT Event Log.
    1. Click on My Computer > Control Panel > Network > Services. 
    Make 
    sure that the following  servic es are listed:
    nComp uter Browser
    nMic rosoft Internet Information Server 2.0
    nNetBIOS Interfac e
    nRPC Config uration
    nSe r ve r
    nWorkstation
    2. Click the Protocols 
    tab , and examine the Network Protoc ols. TCP/IP 
    p rotoc ol should  b e the only one listed .
    3. Click OK
    .
    Test the External Connection to the LAN
    To test the external IP c onnec tions, p ing  the IP Interfac e server and  p ing  a known 
    c omp uter c onnec ted  to your network.
    1. Click Start > Programs > Command Prompt
    .
    2. Type ping 
    nnn.nnn.nnn.nnn (whic h is your IP ad d ress).
    nIf everything  is c onfigured  c orrec tly, the system respond s with the 
    following message:
    Reply from nnn.nnn.nnn.nnn: bytes=32 time
    						