Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-113 Add IP Interface Assembly 5 Figure 5-36. TN802B IP Interface faceplate NOTE: To p rop erly seat the c irc uit p ac k, p ush firmly on the front of the fac ep late until the latc h reac hes the b ottom rail of the c arrier. Then c lose the latc h until it is fully eng ag ed . 1. Insert the TN802B IP Interfac e into the rig htmost of the three slots you reserved for it (see Fig ure 5-37 ). When you p lug in the TN802B IP Interfac e, the c irc uit p ac k starts to b oot and the LCD read s PC Boot then after ab out 3 to 4 minutes it c hang es to IP TRK * , the default mod e. Figure Notes 1. LCD d isp lay 2. Reset b utton (rec essed ) 3. Red b oard status LED4. PCMCIA c ard slot 5. Yellow PCMCIA d isk-in-use LED 1 2 3 4 5 fpdfmapd KLC 030899
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-114 Add IP Interface Assembly 5 Figure 5-37. J58890MA-1 L30 IP Interface Assembly Test the Modem 1. Check for dial tone. 2. Contac t Luc ent Tec hnolog ies Customer Sup p ort and ask a rep resentative to d ial into your IP Interfac e server. Administer the IP Interface Ad minstration is d one either loc ally or remotely. If ad ministered loc ally, p roc eed with the following ad minstration step s on the attac hed keyb oard , mouse, and monitor. If administered remotely, c all your servic e rep resentative to start the p roc ess. 456 789 1 0 1 11 21 3 1 41 51 6 indfmapd KLC 031299
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-115 Add IP Interface Assembly 5 Administration Steps 1. Log in as craft . 2. Type change circuit-pack and p ress En te r. 3. Chec k the Cod e c olumn to see if the slots ab ove the TN802B say DSMAPD or MEDPRO. . 4. If MEDPRO, g o to the entry just ab ove the TN802B that says MEDPRO. 5. Type DSMAPD, and press En te r. Chang ing the one entry automatic ally c hang es the entry ab ove it. If it is in IP Trunk mode, you g et the following error message: MedPro type requires TN802 with application. Type MEDPRO on circuit-packs form. Log onto the TN802B Interface Server If administered remotely throug h p c ANYWHERE: 1. Dial in to the server through pcANYWHERE using the dialup number supplied. 2. Clic k on the p c ANYWHERE Remote Host Computer b utton on the toolb ar to send CTRL ALT DEL to the host. 3. Type administrator in the User Name field . 4. Type iptrunk in the Password field and c lic k OK . 5. After log g ing on for the first time, c hang e the ad ministrator p assword and , if d esired , the user name, to ensure sec urity. See your Wind ows NT server d oc umentation for d etails. change circuit-packs Page 1 of 5 CIRCUIT PACKS Cabinet: 1 Carrier: A Carrier Type: processor Slot Code Sf Mode Name Slot Code Sf Mode Name 11: DSMAPD RESERVED-IP 01: TN754 DIGITAL LINE 12: DSMAPD RESERVED-IP 02: TN758 POOLED MODEM 13: TN802 B MAPD BOARD 03: TN2144 ANALOG LINE 14: 04: TN746 B ANALOG LINE 15: 05 16: 06: TN771 C MAINTENANCE/TEST 07: TN464 F DS1 INTERFACE 08: TN2140 E&M TIE TRUNK 09: TN767 E DS1 INTERFACE 10: TN799 B CONTROL-LAN # indicates circuit pack conflict.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-116 Add IP Interface Assembly 5 If administered loc ally on a monitor, keyb oard, and mouse: 1. Press CTRL, ALT, and DEL simultaneously. 2. Type administrator in the User Name field . 3. Type iptrunk in the Password field and c lic k OK . 4. After log g ing on for the first time, c hang e the ad ministrator p assword and , if d esired , the user name, to ensure sec urity. See your Wind ows NT server d oc umentation for d etails. A-Law versus Mu-Law For systems using A-Law c omp and ing , an ad d itional p roc ed ure is nec essary. On the SAT: 1. Busyout the trunk g roup assoc iated with the IP trunk b y typing busyout board UUCSS and p ressing En t e r. In the Wind ows interfac e to TN802B: 1. Click on Control Panel > Services. 2. Highlight IP Trunk Service , then c lic k on Stop . 3. In the lower left-hand c orner, rig ht-c lic k Start > Exp lore. 4. Go to the c : d rive and c lic k on its, then b in. 5. Double-c lic k on the its.ini file to op en it in Notep ad . 6. Und er the [ Med iaLib ] sec tion, g o to COMPANDING= MLAW. Chang e MLAW to ALAW . 7. Click on File > Save to save the file. 8. Click on File > Exit to exit Notep ad . 9. Click on Control Panel > Services. 10. Highlight IP Trunk Service , then c lic k on Start . NOTE: Do not selec t Startup . After servic e has started , g o to the SAT: 1. Release the trunk g roup assoc iated with the IP trunk b y typing release board UUCSS and p ressing En t e r.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-117 Add IP Interface Assembly 5 Assign Server and Domain Names The Windows NT server identifies servers using a server name plus a domain name that loc ates the named server in a p artic ular p art of the network. The TN802B IP Interfac e is ship p ed with generic server and d omain names. Assig n rep lac ement names that are meaning ful within your network. 1. Click on My Computer > Control Panel > Network . 2. Selec t the Identification tab , then c lic k Change . 3. Typ e the new server name in the Computer Name field . 4. Typ e the new d omain name in the Domain field and c lic k OK > OK > Close . 5. When p romp ted to reb oot the c omp uter, selec t one of the following op tions: nNo if you have not assigned IP ad d resses then g o to ‘‘Assig n an IP Address’’ nYe s if you have assigned IP ad dresses. Assign an IP Address 1. Click on My Computer > Control Panel > Network . 2. Click the Protocols tab . 3. Select TCP/IP Protocol from the list. 4. Click the Properties op tion in the Network wind ow.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-118 Add IP Interface Assembly 5 5. Verify that the Adapter drop d own menu lists 2 DEC Ethernet ad ap ters. !CAUTION: Do not c hange any setting s on the ad ap ter lab eled [ 1] for any reason. 6. Selec t the DEC Ethernet ad ap ter lab eled [ 2] .
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-119 Add IP Interface Assembly 5 7. Typ e a valid IP ad d ress for the IP Interfac e server in the IP Address: field . 8. Typ e the ap p rop riate sub net mask in the Subnet Mask: field. NOTE: Not all networks req uire step s 9 throug h 18. Chec k with the loc al network ad ministrator to determine whic h are req uired . 9. If you use g ateways, type the IP ad d ress of the d efault g ateway for the IP Interfac e server in the Default Gateway: field. 10. Clic k on the DNS tab and verify that the d omain DNS server is c orrec t.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-120 Add IP Interface Assembly 5 11. Typ e d omain name in the Domain field . 12. If using DNS, c lic k Add under the DNS Service Search Order field and type its IP ad d ress. 13. Clic k on the WINS Ad dress tab .
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-121 Add IP Interface Assembly 5 14. Make sure the [ 2] DEC shows in the Adapter field. 15. If WINS server is availab le, typ e its IP ad d ress in the Primary WINS Server field . 16. If DNS is availab le, selec t Enable DNS for Windows Resolution . 17. If the network uses an imp orted LMHOSTS file, selec t Enable LMHOSTS Lookup and Import LMHOSTS and c lic k OK . 18. If the following d ialog b ox op ens, c lic k Ye s : At least one of the adapter cards has an empty primary WINS address. Do you want to continue? 19. Clic k the Bindings tab to effec t the c hang es. NetBIOS Interface, Server, and Workstation should now be enabled. If any are d isab led (a red c irc le with a line throug h it), review the p revious network-c onfig uration step s for omissions or errors. 20. Clic k Close .
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Wire Telephones and Other Equipment 5-122 Add IP Interface Assembly 5 If administered remotely throug h p c ANYWHERE: 21. Clic k on the p c ANYWHERE Restart Host Comp uter b utton on the toolb ar to restart the c omputer. If administered loc ally on a monitor, keyb oard, and mouse: 21. Clic k Ye s in the d ialog b ox to restart the c omp uter. !WARNING: When c onnec ted remotely via p c ANYWHERE, only use the p c ANYWHERE Restart Host Computer b utton on the toolb ar to restart Wind ows NT. Check Network Services When the server restarts, make sure that the req uired network servic es have started c orrec tly. If you see an error d ialog b ox, then the network servic es d id not start c orrec tly. Also, c hec k the NT Event Log. 1. Click on My Computer > Control Panel > Network > Services. Make sure that the following servic es are listed: nComp uter Browser nMic rosoft Internet Information Server 2.0 nNetBIOS Interfac e nRPC Config uration nSe r ve r nWorkstation 2. Click the Protocols tab , and examine the Network Protoc ols. TCP/IP p rotoc ol should b e the only one listed . 3. Click OK . Test the External Connection to the LAN To test the external IP c onnec tions, p ing the IP Interfac e server and p ing a known c omp uter c onnec ted to your network. 1. Click Start > Programs > Command Prompt . 2. Type ping nnn.nnn.nnn.nnn (whic h is your IP ad d ress). nIf everything is c onfigured c orrec tly, the system respond s with the following message: Reply from nnn.nnn.nnn.nnn: bytes=32 time