    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-123 Add IP Interface Assembly 
    5
    3. At the c ommand p romp t, type ping nnn.nnn.nnn.nnn (whic h is the IP 
    ad d ress of your g ateway). 
    nIf everything  is c onfigured  c orrec tly, the system respond s with the 
    following message:
    Reply from nnn.nnn.nnn.nnn: bytes=32 time Settings > Control Panel > 
    Network
    . Selec t the Adapters
     tab  and  hig hlight the [ 2]  DEC 
    ad ap ter.
    nClic k Properties > Change
    . 
    nFrom the Duplex Mod e d ropd own menu, selec t a setting  that 
    matc hes the switc h/hub  that the TN802B c onnec ts to. For examp le, 
    10BaseT Full Dup lex or 10BaseT No Link Test
    4. At the c ommand p romp t, type ping 
    nnn.nnn.nnn.nnn (whic h is the IP 
    ad d ress of another external c omp uter beyond  the g ateway). 
    nIf you have c onnec tivity, the system respond s with the following  
    messag e:
    Reply from nnn.nnn.nnn.nnn: bytes=32 time Programs > Command Prompt
    .
    2. Type ping 
    192.11.13.9 (whic h is the IP ad d ress of the internal IP Interfac e 
    server). 
    nIf everything  is c onfigured  c orrec tly, the system respond s with the 
    following message:
    Reply from 192.11.13.9: bytes=32 time
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-124 Add IP Interface Assembly 
    5
    3. At the c ommand  p romp t, typ e ping 192.11.13.8 (whic h is the IP ad d ress of 
    the internal p roc essor). 
    nIf you have c onnec tivity, the system respond s with the following  
    messag e:
    Reply from 192.11.13.8: bytes=32 time
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-125 Add IP Interface Assembly 
    5
    Connect the Monitor, Keyboard, and Mouse
    1. Attac h a VGA monitor to the VGA c onnec tor of the TN802 IP Interfac e 
    external c ab le assemb ly.
    2. Attac h the keyb oard  to the KEYBOARD c onnec tor of the external c ab le 
    assemb ly.
    3. Attach the mouse to the MOUSE connector of the external c able 
    assemb ly.
    4. Plug  the monitor into an AC p ower rec ep tac le and  turn it on.
    5. If upg rad ing  loc ally, reb oot Wind ows NT b y p ressing  the rec essed  reset 
    b utton on the fac ep late (see Fig ure 5-36
    ) of the TN802B IP Interfac e until 
    the LCD shows a flashing  MSHUT *
    . When the flashing stops and the 
    asterisk d isap p ears (ab out 2 min), it is safe to remove the c irc uit p ac k.
    6. After the TN802B is shut d own, reseat the c irc uit p ac k to restart the 
    system.
    7. Log in using ctrl alt del
    Upgrading IP trunks (R7) to H.323 trunks
    If there are existing  IP trunk c onnec tions that you want to up g rad e to H.323 trunk 
    c onnec tions, d o the following  step s. Otherwise, g o to ‘‘Upg rad e to TN802B (R8)’’ 
    on pag e 5-126
    To upg rad e an existing  IP trunk (R7) to an H.323 trunk (R8) req uires first g etting  
    IP information from the existing  TN802 b efore up g rad ing the TN802 to TN802B.
    1. Click on My Computer > Control Panel > Network
    .
    2. Click the Protocols
     tab .
    3. Select TCP/IP Protocol 
    from the list.
    4. Click the Properties
     op tion in the Network wind ow. Write d own the IP 
    ad d ress, sub net ad d ress, and  g ateway ad d ress shown for ad ap tor [2] 
    (see example b elow).
    NOTE:
    Do not use the ad d resses for ad ap ter [ 1] . 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-126 Add IP Interface Assembly 
    5
    5. When d one, c lic k OK, OK
    .
    Upgrade to TN802B (R8)
    NOTE:
    The upg rad e takes ab out 20 minutes.
    1. Insert the flash d isk into the rig ht most slot on the TN802 IP trunk. On the 
    monitor, a d ialog  b ox assig ns a d rive letter with the removab le med ia 
    d esig nation; the d efault is D:. 
    2. Rig ht c lic k on Start > Explore
     to op en the Wind ows NT Exploring  p ane 
    and  selec t the d rive letter ind ic ated in step  1.
    3. Double-clic k on Medpro 
    and  selec t the Setup  ic on.
    4. Follow the Install Shield  p roc ed ure to transfer all the nec essary files to the 
    TN802 IP Interfac e. 
    NOTE:
    In the Finish d ialog  b ox, selec t I will restart later
    . Do not 
    select Restart computer
    .
    This would  b e a g ood  time to read  the Read me.txt file. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-127 Add IP Interface Assembly 
    5
    5. Click on Start > Settings > Control Panel > Services
    .
    6. Select IP Trunk 
    and click on Startup
    .
    NOTE:
    Do not c lic k on Start.
    7. Under Startup Type, select Disabled
     and  c lic k OK
     to d isab le IP Trunk 
    mod e.
    NOTE:
    If IP trunk and  Med Pro servic es are b oth set to automatic , the 
    TN802B d efaults to IP Trunk and  MedPro features c annot be used .
    8. Select MedPro 
    and c lic k on Startup
    .
    NOTE:
    Do not c lic k on Start.
    9. Under Startup Type, select Automatic
     and  c lic k OK
     to enab le Med Pro 
    mod e.
    10. Clic k Start > Shut Down
     and  selec t Restart the computer?
    or on the TN802:
    Press the rec essed  reset b utton on the fac ep late (see Fi g u re  5 - 3 6
    ) until 
    the LCD shows a flashing  MSHUT *
    . When the flashing stops and the 
    asterisk d isap p ears (ab out 2 min), reseat the c irc uit p ac k to restart the 
    system.
    or on the SAT:
    a. Type busyout board 
    UUCSS 
    and press En te r .
    b. Type reset board
     
    UUCSS and  p ress En te r. 
    c . Typ e release b oard  
    UUCSS and  p ress En te r. 
    Onc e the system is c omp letely initialized , the LCD read s MEDPRO *
    .
    !WARNING:
    When c onnec ted  remotely via p c ANYWHERE, only use the 
    p c ANYWHERE Restart Host Comp uter button on the toolb ar to 
    restart Wind ows NT.
    11. Affix the new TN802B lab el to the c irc uit p ac k.
    12. Disc onnec t the monitor, keyb oard , and  mouse. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-128 Add IP Interface Assembly 
    5
    Circuit Pack Verification
    1. Type change circuit-pack
     and  p ress En te r.
    2. Chec k the Cod e c olumn to see if it says DSMAPD or Med Pro.
    .
    3. To c orrec t it, g o to the entry just above the TN802B that says DSMAPD.
    4. Type MEDPRO, and press 
    En t e r. Changing  the one entry automatic ally 
    c hang es the entry ab ove it. If it is in IP Trunk mode, you g et the following 
    error message:
    MedPro type requires TN802 with application. Type 
    MEDPRO on circuit-packs form.
    5. To c omp lete the ad ministration, refer to the 
    DEFINITY ECS Release 8 
    Network Connec tivity
     b ook.
    change circuit-packs                                            Page   1 of   5 
                                  CIRCUIT PACKS                                     
            Cabinet: 1                            Carrier: A
                                             Carrier Type: processor        
     Slot Code  Sf Mode   Name               Slot Code  Sf Mode   Name
    11: MEDPRO RESERVED-IP
    01: TN754  DIGITAL LINE  12: MEDPRO  RESERVED-IP
    02: TN758  POOLED MODEM  13: TN802  B  MAPD BOARD
    03: TN2144  ANALOG LINE  14: 
    04: TN746  B  ANALOG LINE  15: 
    05 16:         
    06: TN771  C  MAINTENANCE/TEST  
    07: TN464  F  DS1 INTERFACE     
    08: TN2140  E&M TIE TRUNK     
    09: TN767  E  DS1 INTERFACE     
    10: TN799  B  CONTROL-LAN       
      # indicates circuit pack conflict. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-129 Installing an Integrated Channel Service Unit (ICSU) Module 
    5
    Installing an Integrated Channel
    Service Unit (ICSU) Module
    The integ rated c hannel servic e unit (ICSU) is a c omb ination of a 120A CSU 
    mod ule integ rated  with a DS1 c irc uit p ac k. Use this d evic e with the 700A DS1 
    loop b ac k jac k when testing  the DS1 sp an. 
    Checking for required components
    The integ rated c hannel servic e unit (ICSU) p ac kag e c ontains:
    n120A CSU mod ule
    nCab le H600-383
    4-pair modular cord
    Group  2, 50-Foot (15.2 m) c able (standard )
    nCord  DW8A-DE
    4-p air mod ular c ord  to alarm c ontac ts
    nDS1 c irc uit p ac k
    The b asic  ICSU req uires a TN474E or TN777D or later suffix. The 
    enhanc ed  integ rated  c hannel servic e unit req uires a TN474F or TN777E or 
    later suffix. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-130 Installing an Integrated Channel Service Unit (ICSU) Module 
    5
    Installing the 120A CSU
    See Fig ure 5-38. 
    Figure 5-38. 120A Channel Service Unit Module
    !CAUTION:
    Do not p lug  the 120A into any c irc uit p ac k other than a TN474F or TN777E 
    or later release/vintag e. Do not c onnec t the 120A to any interfac e other than 
    a network smart jac k.
    Be sure the DS1 c irc uit p ac k is set for 24-c hannel op eration (1.544 Mb p s). 
    The 120A d oes not op erate with the 32-c hannel interfac e. A switc h on the 
    c irc uit p ac k or ad ministration sets this op tion. 
    !CAUTION:
    Always wear an anti-static  wrist strap when installing  a 120A mod ule. Do 
    not touc h the external alarm c able when it is c onnec ted  to the 120A. Static  
    d isc harg e c an d amag e c onnec tor terminals and  relays. 
    1. Unp lug  the DS1 c irc uit p ac k from its slot.
    2. Install a 4C retainer in the 50-p in p lug  assoc iated  with the DS1 c irc uit p ac k 
    slot.
    1. Rear of c arrier c ontaining  DS1 c irc uit p ac k
    2. 120A CSU
    3. 4-p air c ord  to network interfac e (H600-383)4. DW8A-DE 4-p air c ord  to alarm c ontac ts (op tional)
    5. To 25-p air c onnec tor on rear of c arrier c ontaining  
    DS1 circ uit pac k
    16 17 18 19 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01AU X
    icsupic RBP 032896 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-131 Installing an Integrated Channel Service Unit (ICSU) Module 
    5
    3.Plug  the 120A’s 25-p air c onnec tor d irec tly into the p lug  assoc iated  with 
    the DS1 c irc uit p ac k slot. 
    4. Sec ure the 4C retainer around  the 120A.
    5. Attac h the sup p lied  H600-383 c able to the 120A and to the network smart 
    jac k. 
    This c ab le is d irec tional. To determine the end  that c onnec ts to the 120A, 
    p erform a c ontinuity test b etween pins 3 and  7. The end  with this 
    c ontinuity is the 120A end . The shield  is g round ed  only at the 120A end .
     Use the c ab le p rovid ed . If c ab ling  other than that p rovided  with the 120A 
    is used , ob serve the following  g uid elines:
    nUse 24-g aug e wire that p rovid es ind ividually shield ed , twisted  p airs 
    for transmit and  rec eive sig nals. Use the c ab le b etween the 
    network interfac e and  the 120A. Ground  the shield s of this c able 
    only at the 120A end to avoid  g round  loop s.
    nCab ling  b etween the network interfac e and  120A c an have no 
    bridge taps.
    nIf using  stand ard  house riser c ab le for c onnec tions b etween the 
    network interfac e and  the 120A, maintain a 100-p air sep aration 
    b etween the rec eive and  transmit twisted  p airs.
    nIf using  stand ard  house riser c ab le for c onnec tions b etween the 
    network interfac e and  the 120A, allow no more than 2 c ross 
    c onnec ts to 110-typ e c ross c onnec t bloc ks.
    nNever use quad  c ab le (untwisted  two pair telep hone c ab le) in a 
    DS1 line.
    nAvoid  mixing  wires of d ifferent g aug es in a DS1 line.
    6. If using  external alarm eq uip ment, attac h the sup p lied  DW8 c ab le to the 
    120A and  the external eq uip ment. The maximum length of this c ab le 
    d ep end s on the alarm eq uip ment.
    7. If a TN474F is used , make sure the c irc uit p ac k is set for 24-c hannel 
    op eration. Set the switc h on the c irc uit p ac k as shown in Fig ure 2-1.
    8. From the DS1 c irc uit-p ac k form of the system ad ministration c onsole, set 
    the line c omp ensation field  to 0-133 feet (40.6 m).
    9. Reset the 120A b y reseating  the DS1 c irc uit p ac k.
    When you reinsert the DS1 c irc uit p ac k after installing  a 120A CSU the 
    120A resets. The DS1 c irc uit p ac k initializes and  tests the 120A. When 
    initialization and  testing  is c omp lete, the g reen LED goes off. If the RED 
    indic ator is OFF after the test, the ICSU is working .
    10. If the c irc uits d o not p ass the self test, troub leshoot the 120A as instruc ted  
    in 
    Integ rated  CSU Mod ule Installation and  Op eration. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-132 Installing an Integrated Channel Service Unit (ICSU) Module 
    5
    Tab le 5-32 p rovid es the H600-383 c ab le p inouts. Table 5-33 p rovid es the c ab le 
    leng ths for eac h c ab le g roup  numb er.
    Table 5-32. H600-383 cable Pin Assignments
    Pin ColorChannel Service 
    Unit DesignationNetwork 
    Designation Function
    1BK Line in 0 R1 RCV
    2 Y Line in 1 T1
    3 Shield
    4 R Line out 0 R XMT
    5 G Line out 1 T
    6 Shield
    7 Not assigned
    8 Not assigned
    Table 5-33. H600-383 cable Lengths by Group Number
    Group Length Group Length
    1 25 feet (7.7 m) 5 125 feet (38.1 m)
    2 50 feet (15.2 m) 6 200 feet (71 m)
    3 75 feet (22.9 m) 7 400 feet (122 m)
    4 100 feet (30.5 m) 8 750 feet (198.1 m) 
    						