Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Connect the Cabinets 1-23 Connect Time Division Multiplexing Bus Cables 1 Figure 1-11. Connections for Standard Reliability Systems Figure Notes 1. AHF110 TDM Bus Terminator (Slot 17) 2. TDM/Loc al Area Network (TDM/LAN) Pinfield (Slot 00) 3. TDM Bus Cab le WP-91716 L34. Port Cabinet (Stand ard Reliab ility) 5. Control Cab inet A Position 6. AHF110 TDM Bus Terminator (Slot 03) 7. Slot 18 3 3 3 7 4 4 4 5 12 2 2 6 tdm_cab2 CJL 030696
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Connect the Cabinets 1-24 Connect Time Division Multiplexing Bus Cables 1 Figure 1-12. Connections for High or Critical Reliability Systems Figure Notes 1. AHF110 TDM Bus Terminator (Slot 17) 2. TDM/Loc al Area Network (TDM/LAN) Pinfield (Slot 00) 3. TDM b us Cable (WP-91716 L3) 4. Port Cab inet 5. Control Cab inet A Position 6. AHF110 TDM Bus Terminator (Slot 01)7. Slot 18 8. Inter-Cab inet Cab les (ICC) A, B and C (H600-248-G1) 9. Inter-Cab inet Cab le (ICC) A 10. Inter-Cab inet Cab le (ICC) B 11. Dup lic ated Control Cab inet B Po s i t io n 3 7 7 4 4 11 8 5 12 2 9 9 6 2 10 10 tdm_cab3 CJL 053096
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Connect the Cabinets 1-25 Connect Time Division Multiplexing Bus Cables 1 Figure 1-13. Connections for High or Critical Reliability Systems Figure Notes 1. AHF110 TDM Bus Terminator (Slot 17) 2. TDM/Loc al Area Network (TDM/LAN) Pinfield (Slot 00) 3. TDM b us Cable (WP-91716 L3) 4. Port Cab inet 5. Control Cab inet A Position6. AHF110 TDM Bus Terminator (Slot 03) 7. Slot 18 8. Inter-Cab inet Cab les (ICC) B and C (H600-259-G1) 9. Dup lic ated Control Cab inet B Po si t io n 3 3 3 7 4 4 9 5 12 2 2 8 8 6 tdm_cab4 CJL 053096
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Connect the Cabinets 1-26 Verify Port Cabinet Address Plugs 1 Verify Port Cabinet Address Plugs The address plug is a jumper field on port cabinets only. The address plug is loc ated on the far rig ht hand side of the bac kp lane, to the rig ht of slot 00. A g roup of six p ins is lab eled for the c ab inet (c arrier) jump er c onnec tions. Verify the address plug for eac h p ort c arrier is in the c orrec t loc ation for that c arrier. See Fig ure 1-14 . The fac tory d efault setting is “ B” (Callout 2 in Figure 1-14). Figure 1-14. Port Cabinet Address Plug Location — Cabinet Rear Figure Notes 1. Ad dress Plug (Shown Set to Carrier D) 2. Carrier B Jump er Loc ation (Default) 3. Carrier C Jumper Location 4. Rig ht Edg e of Bac kp lane5. Rig ht Ed ge of Cab inet 6. Bac kp lane Slot 00 7. To Connec tor Panel 3 45 1 6 2 7 add_plug CJL 050906
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Connect the Cabinets 1-27 Install Rear Panels 1 Install Rear Panels Figure 1-15. Rear Panel Screw Locations 1. Install the rear p anels and loosely thread eac h sc rew. See Fig ure 1-15 . 2. For unstacked c ab inets, tig hten the sc rews sec urely. Fo r a stack of cab inets, allow the screws lab eled Callout 4 to remain loose. These sc rews are tig htened when the g round p lates are installed . 3. Be sure the Time Division Multiplexing (TDM) b us c ab les and the Inter-Cab inet Cab les (ICC) are not p inc hed by the p anels. Also be sure the c ab les are routed through the c hannels p rovided on the rear p anels. Figure Notes 1. Cabinet in A Position (No Ground Plate is Installed on an Unstac ked Cab inet) 2. Rear Ground Plate (Attac hed Between Stac ked Cabinets)3. Cab inet in B Position 4. Sc rews to Loosen 21 3 44 grnd_plt CJL 030696
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Connect the Cabinets 1-28 Install Ground Plates 1 Install Ground Plates Ground p lates are installed b etween stac ked c ab inets, p rovid e the ground c onnec tion between c ab inets, p rovid e rad io freq uenc y (RF) rad iation protec tion, and help stab ilize the c ab inets. Install Rear Ground Plates (Systems with Earthquake Protection) 1. Loosen the four sc rews at the b ottom of the top c ab inet and at the top of the c ab inet und erneath the top c ab inet. See Fig ure 1-15 . 2. Alig n the mounting holes in the rear g round p late over the b ottom sc rews in the top c ab inet. See Fig ure 1-16 . 3. Alig n the mounting holes in the g round p late with the four holes at the top of the c ab inet b elow the top c abinet. Slid e the mounting plate d own to seat on the sc rews. 4. Chec k all Time Division Multip lexing (TDM) b us c ab les and the Inter Cab inet Cab les (ICC) to b e sure they are not p inc hed b y the p lates. 5. Rep eat Step s 1-3 until the rear ground p lates are installed b etween all stacked cabinets. 6. Do not tig hten the sc rews yet. Install Front Ground Plates (Systems with Radiation Shielding and Earthquake Protection) Use the front g round p late instead of the c ab inet c lip to attac h the c ab inets to eac h other. Use one front g round p late b etween two stac ked c ab inets. 1. At the front of the c ab inets, alig n the holes in the top of the front g round p late with the holes at the b ottom of the up per c ab inet, and insert the four sc rews. Do not tighten the sc rews yet. See Fig ure 1-16 . 2. At the front of the c ab inets, alig n the holes in the b ottom of the front g round p late with the holes at the top of the lower c ab inet. Insert the four sup p lied #12-24 x 1/2-inc h (1.27 c m) thread -forming sc rews. Do not tig hten the sc rews yet. 3. Rep eat Step s 1 and 2 until all stac ked c abinets are fastened tog ether. 4. Tighten all screws securely.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Connect the Cabinets 1-29 Install Ground Plates 1 Figure 1-16. Rear Ground Plate and Front Plate or Cabinet Clip — Side View Figure Notes 1. Front Ground Plate or Cabinet Clip 2. Battery3. Rear Ground Plate 3 2 1 grdpltec LJK 031096
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Connect the Cabinets 1-30 Install Ground Plates 1 Install Cabinet Clips (Systems without Earthquake Protection) A c ab inet c lip is required b etween eac h p air of stac ked c ab inets. At the front of the c ab inets, install a c ab inet c lip b etween eac h p air of c ab inets b y hooking the c lip into the slot of the up p er c ab inet and snap p ing the straig ht leg of the c lip into the slot on the lower c ab inet. See Fig ure 1-17 . Figure 1-17. Location of Cabinet Clips Figure Notes 1. Control Cab inet 2. Port Cab inet or Dup lic ated Control Cab inet 3. Port Cab inet4. Port Cab inet 5. Cab inet Clip s
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Connect the Cabinets 1-31 Connect System Cables 1 Connect System Cables Inter-Cabinet Cables (High or Critical Reliability) 1. Connec t the c ab les for c ritic al reliab ility Exp ansion Port Networks (EPNs) as shown in Figure 1-12 and in Tab le 1-1 below. 2. Connec t the c ab les for hig h or c ritic al reliab ility Proc essor Port Networks (PPNs) as shown in Fig ure 1-13 . Fiber Optic Cables The fib er op tic c ables are c onnec ted to the Main Distrib ution Frame (MDF) in Chapter 2, ‘‘Install Telec ommunic ations Cab ling’’ . Refer to Ap pend ix B, ‘‘Connec ting and Hand ling Fib er Optic Cab les’’ for information about c onnec ting to op tic al c ross-c onnec t hard ware and routing throug h lig htg uid e eq uip ment. The DEFINITY ECS may c ontain a Class 1 LASER devic e if sing le-mod e fib er op tic c ab le is c onnec ted to a remote Exp ansion Port Network (EPN). The LASER d evic e op erates within the following p arameters: Maximum Power Outp ut: -5 d Bm Waveleng th: 1310 nm Mod e Field Diameter: 8.8 mic rons CLASS 1 LASER PRODUCT IEC 825 1993 !CAUTION: Use of c ontrols or ad justments or p erformanc e of p roc ed ures other than those sp ec ified herein may result in hazard ous rad iation exp osure. Contac t your Luc ent Tec hnolog ies rep resentative for more information. Table 1-1. Inter-Cabinet Cable Connections From Cabinet A To Cabinet B Cabinet Carrier Connection Carrier Connection Proc essor Port N et w o r k ( PPN )J58890L (ICC) B J58890M (ICC) B (ICC) C (ICC) C Exp an si o n Po r t N et w o r k ( EPN )J58890N (ICC) A J58890H (ICC) A (ICC) B (ICC) B
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Install and Connect the Cabinets 1-32 Connect System Cables 1 Fiber Optic Cable Connections The Customer Servic e Doc ument (CSD) p rovides an “ Inter-Cabinet Cab le Running List.” Eac h row on the list rep resents a c ab le c onnec tion. Use the running list to d etermine where to c onnec t eac h fib er op tic c ab le. Multi-Mode Fiber Optic Connections The following c omponents are used in multi-mod e fib er op tic c onnec tions: nExp ansion Interfac e (EI) c irc uit p ac ks in p ort slots in c ab inet c arriers nCab les from eac h interfac e c irc uit pac k to eac h p ort slot c onnec tor nThe 9823A lig htwave transc eiver transmits up to 4,900 feet (1.5 km). The 9823B lig htwave transc eiver transmits up to 25,000 feet (7.6 km). nMulti-mod e fib er op tic c ab le c onsists of two sep arate 62.5 mic ron d iameter fib er optic c ab les or 50 mic ron d iameter fib er op tic c ab les. Single-Mode Fiber Optic Connections The following c omponents are used in sing le-mode fiber op tic c onnec tions: nExp ansion Interfac e (EI) c irc uit p ac ks in p ort slots in c ab inet c arriers nCab les from eac h interfac e c irc uit pac k to eac h p ort slot c onnec tor nThe 300A lig htwave transc eivers transmits lig ht up to 115,000 feet (35 km). Fib er loss must b e less than 17d B. Saturation may oc c ur if d istanc es are short; attenuators may b e req uired if the total loss on the fib er link is less than 10d Bm. An Op tic al Time Domain Reflec tometer (OTDR) test is rec ommend ed to d etermine sp ec ific fib er optic hard ware req uirements. nSing le-mode fib er op tic c ab le c onsists of two sep arate 8 to 10 mic ron c ore cables. NOTE: 5 and 10d B attenuators are availab le. Contac t your Luc ent Tec hnologies representative for more information.