    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-103 Add IP Interface Assembly 
    5
    2. Insert the TN802B IP Interfac e into the rig ht most of the three slots you 
    reserved  for it (see Fig ure 5-33
    ) and  seat it p rop erly.
    When you p lug  in the TN802B IP Interfac e Assemb ly, the c irc uit p ac k 
    starts to b oot and  the LCD read s PC Boot
    . The c irc uit p ac k reboots 
    automatic ally, and after ab out 3 to 4 minutes the LCD c hang es to IPTRK*
    , 
    the d efault mod e, or MEDPRO*
    . 
    If the TN802B is pre-ad ministered  at the fac tory, it reb oots several times to 
    initialize to Med Pro mode.
    If the TN802B is not p re-ad ministered , g o to ‘‘
    Administration Steps’’ on 
    page 5-104
    NOTE:
    For an initial installation, the TN802B IP Interfac e need s to b e 
    administered first (see ‘‘
    Ad minister the IP Interfac e’’ on p age 5-104). 
    Figure 5-33. J58890MA-1 L30
     IP Interface Assembly
    456
    789
    1
    0
    1
    11
    21
    3
    1
    41
    51
    6
    indfmapd KLC 031299 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-104 Add IP Interface Assembly 
    5
    Administer the TN799B C-LAN
    Refer to the DEFINITY Enterp rise Communic ations Server Ad ministration for 
    Network Connec tivity
    .
    Administer the IP Interface
    Ad ministration is usually d one remotely; c all your servic e rep resentative to start 
    the process.
    Administration Steps
    NOTE:
    Refer to the DEFINITY Enterp rise Communic ations Server 
    Ad ministration for Network Connec tivity for Release 8
     for sp ec ific  
    information.
    1. Log in as craft
    .
    2. Type change node-names
     and  p ress 
    En te r.
    3. On sc reen 2, typ e in the node name and  IP add ress for the TN802B.
    4. Type change circuit-pack
     and  p ress 
    En te r.
    5. Chec k the Cod e c olumn to see if the slots ab ove the TN802B say 
    DSMAPD or MEDPRO.
    change node-names                                               Page   2 of   6 
                                      NODE NAMES                                    
        Name             IP Address           Name              IP Address
    clan-a1             192.168.1 .31  .   .   . 
    clan-b1             192.168.2 .31  .   .   . 
    default             0  .0  .0  .0  .   .   . 
    med-a1              192.168.1 .81  .   .   . 
    .   .   .  .   .   .   
    .   .   .  .   .   .   
    .   .   .  .   .   .    
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-105 Add IP Interface Assembly 
    5
    .
    6. If not, typ e MEDPRO in the slot just ab ove TN802B slot and  p ress En t e r. 
    Chang ing the one entry automatic ally c hang es the entry ab ove it. If it is in 
    IP Trunk mod e, you g et the following error messag e:
    MedPro type requires TN802 with application. Type 
    MEDPRO on circuit-packs form.
    7. Type change ip-interfaces
     and press 
    En te r. 
    8. Typ e in the information for the TN802B IP Interfac e, 
    9. Set the Enabled
     field  to y
    , and press 
    En te r.
    NOTE:
    The c ustomer provid es the IP add ress, sub net mask, and  g ateway 
    address.
    At this time the TN802B LCD read s PC BOOT *
    , and  ab out 3 to 4 minutes 
    later read s MEDPRO *
     with the asterisk flashing
    change circuit-packs                                            Page   1 of   5 
                                  CIRCUIT PACKS                                     
            Cabinet: 1                            Carrier: A
                                             Carrier Type: processor        
     Slot Code  Sf Mode   Name               Slot Code  Sf Mode   Name
    11: MEDPRO RESERVED-IP
    01: TN754  DIGITAL LINE  12: MEDPRO  RESERVED-IP
    02: TN758  POOLED MODEM  13: TN802  B  MAPD BOARD
    03: TN2144  ANALOG LINE  14: 
    04: TN746  B  ANALOG LINE  15: 
    05 16:         
    06: TN771  C  MAINTENANCE/TEST  
    07: TN464  F  DS1 INTERFACE     
    08: TN2140  E&M TIE TRUNK     
    09: TN767  E  DS1 INTERFACE     
    10: TN799  B  CONTROL-LAN       
      # indicates circuit pack conflict. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-106 Add IP Interface Assembly 
    5
    .
    Test the External Connection to the LAN
    To test the external IP c onnec tions, p ing the IP Interfac e server, and  p ing  a 
    known c omp uter c onnec ted  to your network. If everything  is c onfig ured c orrec tly, 
    the Result
     c olumn on the Ping  Results sc reen read s pass
    . If it read s abort
    , 
    verify the IP-ad d ress information and  c hec k the c onnec tivity, inc lud ing  the 
    cabling.
    1. Type ping ip-address 
    nnn.nnn.nnn.nnn board UUCSS and p ress En t e r. 
    Th e  v a r i a b l e  
    nnn.nnn.nnn.nnn is the IP ad d ress of the TN802B IP 
    Interfac e and  
    UUCSS is the c ab inet, c arrier, and  slot of the TN802B IP 
    Interfac e.
    2. Type ping ip-address 
    nnn.nnn.nnn.nnn board UUCSS and p ress En t e r. 
    Th e  v a r i a b l e  
    nnn.nnn.nnn.nnn is the IP ad d ress of the c ustomer’s 
    g ateway and  
    UUCSS is the c ab inet, c arrier, and  slot of the TN802B IP 
    Interfac e.
    change ip-interfaces                                            Page   1 of   2 
                                                                                    
     Network regions are interconnected?  n
      En-                                                                        Net
     abled Type   Slot  Code Sfx Node Name       Subnet Mask     Bcast/Gway 
    Addr Rgn
       n   C-LAN  01A09 TN799    clan-a1         255.255.255.0   192.168.1 .100 1 
    y  MEDPRO 01A13 TN802  B med-a1  255.255.255.0  192.168.1 .21  1 
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
       n                                         255.255.255.0      .   .   .      
    ping ip-address 192.168.10.21                                                   
                                                                                    
                              PING RESULTS
      End-pt IP        Port      Port Type  Result    Time(ms)  Error Code
      192.168.10.21    01A13 MEDPRO PASS  10 1124  
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-107 Add IP Interface Assembly 
    5
    3. Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and p ress En t e r. 
    Th e  v a r i a b l e  
    nnn.nnn.nnn.nnn is the IP ad d ress of another c omp uter 
    b eyond  the g ateway and  
    UUCSS is the c ab inet, c arrier, and  slot of the 
    TN802B IP Interfac e.
    The TN802B IP Interfac e is now installed  in the DEFINITY c arrier and  c onnec ted  
    to the IP network.
    Installing in IP Trunk Mode
    NOTE:
    IP Trunk mod e should  only b e used  to maintain c omp atib ility with existing  
    Release 7 IP Trunk or ITS-E installations. We strong ly rec ommend  that 
    Med Pro mod e b e used  whenever p ossib le.
    Prepare for Installation
    Have the following  eq uip ment on site b efore your ship ment arrives:
    nA mouse, keyboard , and  VGA monitor for use d uring  the installation of the 
    server. You also need  AC p ower outlets for the mod em and monitor.
    nThree ad joining , unoc c up ied  p ort slots in the DEFINITY ECS
    The TN802B IP Interfac e slid es into only 1 slot, b ut its fac ep late oc c up ies 
    3 slots.
    nA 10 BaseT or 10/100 BaseT Ethernet c onnec tion into the c ustomer’s loc al 
    area network (LAN)
    nA valid , unused IP ad d ress on the c ustomer’s LAN that c an b e assig ned  to 
    the IP Interfac e server. You also need  the sub net mask, d efault g ateway, 
    d omain name, and  so forth from the c ustomer’s network ad ministrator.
    nAn analog telep hone line reserved  for the IP Interfac e d iag nostic  mod em
    nA valid  telep hone numb er reserved  for the IP Interfac e d iag nostic  mod em
    If non-U.S. c ustomer:
    nMod em c omp arab le to a U.S. Rob otic s, Inc . Sp ortster Mod el USR 33.6 
    EXT.
    nA c ab le from the mod em to the TN802B external c ab le assemb ly.
    We rec ommend  that you p rotec t the c ab inet where the IP Interfac e is installed  
    with an uninterrup tib le p ower system (UPS). 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-108 Add IP Interface Assembly 
    5
    Check your Shipment
    When your DEFINITY IP Trunk ord er arrives at the c ustomer’s site, c hec k the 
    c ontents (see Tab le 5-30
    ).
    1. Insp ec t the ship p ing  c arton for d amag e b efore op ening  it. If the b ox is 
    damaged, 
    do not open it. Inform the ship p ing  c omp any, and  ask for 
    instruc tions on filing a c laim.
    2. If the b ox is und amag ed , c hec k the c ontents ag ainst the p ac king  slip . 
    Chec k the c ondition of eac h c omp onent, and note any d amag e or 
    shortag es on the p ac king  slip . The c arton should  c ontain the following  for 
    eac h IP Interfac e ord ered :
    .
    The TN802B external c ab le assemb ly is a bund le of c ab les with an amp henol 
    c onnec tor at the end  of the b und le and  various PC-typ e c onnec tors (VGA, 
    Universal Serial Bus [ USB] , mouse, keyb oard , Ethernet, mod em, and  COM2) at 
    the end s of the ind ivid ual c ab les. See Fig ure 5-34
    . Look for the lab el where the 
    b und le enters the amp henol c onnec tor.
    Table 5-30. Required Hardware
    Comcode/Code Description Quantity
    J58890MA-1 L30 TN802B IP Interfac e Assemb ly
    1
    601939804 H600-512,G1 external c ab le assemb ly 1
    407633999 U.S. Robotic s Sp ortster external 
    mod em, mod el numb er USR 33.6 EXT 
    (U.S. c ustomers only) 
    1
    1. For non-U.S. customers, you need  a mod em c omparable to the U.S. Rob otic s
    Sportster and a serial c ab le. 
    1
    601087091 20-ft DB-25 serial c ab le from mod em 
    to TN802B external c ab le assembly 
    (U.S. c ustomers only) 
    2
    1 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-109 Add IP Interface Assembly 
    5
    Figure 5-34. TN802B IP Interface External Cable Assembly
    3. Read  and  follow any d irec tions inserted  into the p ac kag e b y the fac tory.
    Connect the Cables
    1. Determine into whic h p ort slot you are p utting  the TN802B IP Interfac e.
    NOTE:
    Make sure that at least 3 ad joining  slots are free.
    2. From the rear of the c ab inet, c onnec t the amp henol c onnec tor on the 
    external c ab le assemb ly to the b ac kp lane c onnec tor c orrespond ing  to 
    that slot (the hig hest numbered  c onnec tor of the 3 slots required ). Figure Notes
    1. Amp henol c onnec tor to c onnec tor 
    c orresp ond ing  to TN802B slot
    2. To VGA monitor
    3. To USB (not used )
    4. To keyb oard5. To mouse
    6. To ethernet
    7. 25-p in male c onnec tor to mod em
    8. 25-p in male c onnec tor to COM2 
    cbdfocto AWF 122398
    2
    1
    345678 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-110 Add IP Interface Assembly 
    5
    Connect the Modem
    NOTE:
    These instruc tions are for c onnec ting  the U.S. Rob otic s modem sup p lied  to 
    U.S. c ustomers only. If using  a d ifferent mod em, follow the manufac turer’s 
    instruc tions on c onnec ting  the mod em.
    1. Connec t the RS232 p ort of the mod em to the MODEM c onnec tor of the 
    TN802B external c ab le assembly. 
    NOTE:
    Chec k the lab els near the c onnec tors; the MODEM and  COM2 
    c onnec tors look the same.
    2. Connec t an analog  telephone line to the leftmost analog -line p ort on the 
    mod em as shown in Fig ure 5-35
    . 
    3. Make sure that the mod em’s DIP switc hes are set as shown in 
    Fi g u re  5 - 3 5
     and Tab le 5-31. 
    4. Plug  the mod em into an AC p ower outlet.
    5. Turn on the mod em using  the switc h on the front of the mod em.
    Figure 5-35. External Modem Connections for U.S. Robotics Sporster Figure Notes
    1. Connec t analog  line here.
    2. DIP switc h 5 must b e up .3. Connec t MODEM c onnec tor here.
    4. Connec t p ower c onnec tor here.
    12345678
    modfrobo KLC 030499
    234
    1 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-111 Add IP Interface Assembly 
    5
    Connect the Monitor, Keyboard, and Mouse
    NOTE:
    Only make these c onnec tions if ad ministered  loc ally. Not nec essary if 
    ad ministered  remotely.
    You must c onnec t these b efore inserting  the TN802B IP Interfac e.
    1. Attac h a VGA monitor to the VGA c onnec tor of the TN802B IP Interfac e 
    external c ab le assemb ly.
    2. Attac h the keyb oard  to the KEYBOARD c onnec tor of the external c ab le 
    assemb ly.
    3. Attach the mouse to the MOUSE connector of the external c able 
    assemb ly.
    4. Plug  the monitor into an AC p ower rec ep tac le and  turn it on.
    Table 5-31. U.S. Robotics Modem Dip Switch Settings
    Dip 
    Switch Setting Description
    1UP
    DOWNData Terminal Read y normal
    Data Terminal Read y overrid e
    2UP
    DOWNVe r b a l  r e s u lt  c o d e s
    Numeric  result c od es
    3UP
    DOWNSuppress result codes
    Disp lay result cod es
    4UP
    DOWNEc ho offline c ommand s
    No ec ho, offline c ommand s
    5UP
    DOWNAuto answer on first ring or higher if specified in NVRAM
    Auto answer off
    6UP
    DOWNCarrier d etec t normal
    Carrier d etec t overrid e
    7UP
    DOWNLoad  NVRAM d efaults
    Load  fac tory d efaults
    8UP
    DOWNDumb  mod e
    Sm a rt  m o d e 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Wire Telephones and Other Equipment 
    5-112 Add IP Interface Assembly 
    5
    Connect the Ethernet
    1. Connec t the network c ab le to the ETHERNET c onnec tor on the TN802B 
    external c ab le assemb ly.
    NOTE:
    You need  a CAT5 or better c ab le for 100-Mb yte operation.
    Install the Circuit Pack
    !CAUTION:
    When add ing  or rep lac ing  any hard ware, b e sure to g round  yourself against 
    elec trostatic  d isc harg e (ESD) b y wearing  a g round ed  wrist strap .
    NOTE:
    The TN802B IP Interfac e is hot-swap p ab le, so you d o not need  to p ower 
    d own the c arrier to install it.
    If you need  to remove the TN802B IP Interfac e from the c arrier at a later 
    time, shut down Wind ows NT first b y p ressing the rec essed reset button on 
    the fac ep late (see Figure 5-36
    ) of the TN802B IP Interfac e until the LCD 
    shows a flashing MSHUT *
    . When the flashing  stop s and  the asterisk 
    d isap p ears (ab out 2 min), it is safe to remove the c irc uit p ac k. 
    						
    All Lucent Technologies manuals Comments (0)