    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    About This Book 
    xi How to Comment on This Document 
    How to Comment on This Document
    Luc ent Tec hnolog ies welc omes your feedb ac k. Please fill out the read er 
    c omment c ard  found  at the front of this manual and  return it. Your c omments are 
    of g reat value and  help  imp rove our d oc umentation.
    If the reader c omment c ard  is missing , FAX your c omments to 1-303-538-1741 or 
    to your Luc ent Tec hnolog ies rep resentative, and mention this d oc ument’s name 
    and number, 
    DEFINITY Enterp rise Communic ation Server Release 8 Installation 
    and  Test for Sing le-Carrier Cab inets
    .
    Trademarks
    This d oc ument c ontains referenc es to the following  Luc ent Tec hnolog ies 
    trad emarked prod uc ts:
    nACCUNET®
    nAUDIX®
    nCallmaster®
    nCallVisor®
    nC O N VERSA N T®
    nDEFINITY®
    nFO RU M™
    nMEGACOM®
    nSYSTI M A X®
    nTRA N STA L K™
    The following prod uc ts are trad emarked  b y their ap p rop riate vend or:
    nAud ic hron® is a reg istered  trad emark of Aud ic hron Comp any.
    nLINX™ is a trad emark of Illinois Tool Works, Inc .
    nMusic  Mate® is a reg istered  trad emark of Harris Corp oration.
    nPa g e Pa c® is a reg istered  trademark of Harris Corp oration, Drac on 
    Division.
    nPORTA™ Systems is a trad emark of PORTA Systems Corp oration.
    nShoc kwatc h® is a reg istered  trad emark of Med ia Rec overy, Inc orp orated .
    nStyrofoam® is a reg istered  trad emark of Styrofoam Corp oration.
    nTi l t w a t c h® is a reg istered  trad emark of Med ia Rec overy, Inc orp orated .
    nZone Mate® is a reg istered trad emark of Harris Corp oration. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    About This Book 
    xii Standards Compliance 
    Standards Compliance
    The eq uip ment p resented  in this doc ument c omp lies with the following  stand ard s 
    (as ap p rop riate):
    nITU-T (Formerly CCITT)
    nEC M A
    nETSI
    nIPNS
    nDPNSS
    nNational ISDN-1
    nNational ISDN-2
    nISO-9000
    nANSI
    nFCC Part 15 
    nEN55022
    nEN50081
    nEN50082
    nC I SPR2 2
    nAustralia AS3548 (AS/NZ3548)
    nAustralia AS3260
    nIEC 825
    nIEC 950
    nUL 1459
    nUL 1950
    nCSA C222 Number 225
    nTS0 0 1 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    About This Book 
    xiii LASER Product 
    LASER Product
    The DEFINITY ECS may c ontain a Class 1 LASER devic e if sing le-mod e fib er 
    op tic  c ab le is c onnec ted  to a remote Exp ansion Port Network (EPN). The LASER 
    d evic e op erates within the following  p arameters:
    Maximum Power Outp ut: -5 d Bm
    Waveleng th: 1310 nm
    Mod e Field  Diameter: 8.8 mic rons
    CLASS 1 LASER PRODUCT
    IEC 825 1993
    !CAUTION:
    Use of c ontrols or ad justments or p erformanc e of p roc ed ures other than 
    those sp ec ified  herein may result in hazard ous rad iation exp osure.
    Contac t your Luc ent Tec hnolog ies rep resentative for more information.
    Electromagnetic Compatibility 
    Standards
    This p rod uc t c omp lies with and  c onforms to the following  EMC stand ard s (as 
    ap p rop riate):
    nLimits and  Methods of Measurements of Rad io Interferenc e 
    Charac teristic s of Information Tec hnolog y Eq uipment, EN55022 
    (CISPR22), 1993
    nEN50082-1, Europ ean Generic  Immunity Standard
    nFCC Parts 15 and  68
    nAustralia AS3548
    NOTE:
    The system c onforms to Class A (ind ustrial) eq uip ment. Voic e 
    terminals meet Class B requirements.
    nElec trostatic  Disc harg e (ESD) IEC 1000-4-2
    nRad iated  rad io freq uenc y field  IEC 1000-4-3
    nElec tric al Fast Transient IEC 1000-4-4
    nLightning  effec ts IEC 1000-4-5
    nConduc ted radio freq uenc y IEC 1000-4-6
    nMains freq uenc y mag netic  field  IEC 1000-4-8
    nLow freq uenc y mains d isturb anc e IEC 1000-4-11 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    About This Book 
    xiv Security Issues 
    European Union Standards
    Luc ent Tec hnolog ies Business Communic ations Systems d ec lares that the 
    DEFINITY eq uip ment sp ec ified  in this d oc ument b earing  the “ CE”  mark c onforms 
    to the Europ ean Union Elec tromag netic  Compatib ility Direc tives.
    The “ CE”  (Conformité Europ eénne) mark ind ic ates c onformanc e to the Europ ean 
    Union Elec tromag netic  Comp atib ility Direc tive (89/336/EEC) Low Voltag e 
    Direc tive (73/23/EEC) and  Telec ommunic ation Terminal Eq uip ment (TTE). 
    Direc tive (91/263/EEC) and  with i-CTR3 Basic  Rate Interfac e (BRI) and  i-CTR4 
    Primary Rate Interfac e (PRI) as ap p lic able.
    The “ CE”  mark is ap plied  to the following  Release 8 prod uc ts:
    nGlob al AC p owered  Multi-Carrier Cab inet (MCC)
    nDC p owered  Multi-Carrier Cab inet (MCC) with 25 Hz ring  g enerator
    nAC p owered  Single-Carrier Cab inet (SCC) with 25 Hz ring  g enerator
    nAC p owered  Comp ac t Sing le-Carrier Cab inet (CSCC) with 25 Hz ring  
    g enerator
    nEnhanc ed DC Power System
    Security Issues
    To ensure the c ustomer of the g reatest sec urity p ossib le, Luc ent Tec hnologies 
    offers servic es that c an red uc e toll fraud  liab ilities. Contac t your Luc ent 
    Tec hnolog ies rep resentative for more sec urity information.
    Log in sec urity is an attrib ute of the DEFINITY Enterp rise Communic ations Server 
    (ECS) software. Ad vise c ustomers that their existing  p assword s exp ire 24 hours 
    after the up g rad e. Also exp lain that the new p assword s must c onform to stric t 
    req uirements. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    About This Book 
    xv Where to Call for Technical Support 
    Where to Call for Technical Support
    Use the following  telep hone numb ers for the reg ion in whic h the system is b eing  
    installed :
    Antistatic Protection
    !CAUTION:
    When hand ling  c irc uit pac ks or any c omp onents of a DEFINITY System, 
    always wear an authorized  wrist g round  strap . Connec t the strap  to an 
    ap p roved  g round  suc h as an unp ainted  metal surfac e on the DEFINITY 
    Sys t e m .
    Te l e p h o n e  N u m b e r
    DEFINITY Help line (feature ad ministration and  system 
    applications)1-800-225-7585
    Luc ent Tec hnolog ies Toll Fraud  Intervention 1-800-643-2353
    Luc ent Tec hnolog ies National Customer Care Center 1-800-242-2121
    Luc ent Tec hnolog ies Corp orate Sec urity 1-800-822-9009
    Streamlined  Imp lementation (for missing  eq uip ment) 1-800-772-5409
    USA/Canada Tec hnic al Servic e Center 1-800-248-1234
    ITAC 1-303-804-3777
    Luc ent Tec hnolog ies Centers of Exc ellenc e
    Asia/Pac ific  Reg ional Sup p ort Center 65-872-8686
    Western Europ e/Mid d le East/South Afric a 44-1252-77-4800 
    Central/Eastern Europ e 361-345-4334
    Central/Latin Americ a Carib b ean 1-303-804-3778
    Australia 61-2-9352-9090
    North Americ a (INADS Datab ase Ad ministration) 1-800-248-1111 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    About This Book 
    xvi Remove/Install Circuit Packs 
    Remove/Install Circuit Packs
    !CAUTION:
    The control circuit packs with white lab els cannot be removed  or installed  
    when the power is on. The p ort c irc uit pac ks with g ray lab els (older version 
    circuit packs had purple labels) can be removed or installed when the 
    p ower is on.
    Federal Communications Commission 
    Statement
    Part 68: Statement
    Part 68: Answer-Sup ervision Sig naling . Allowing  this eq uip ment to b e op erated in 
    a manner that d oes not p rovid e p rop er answer-sup ervision sig naling is in 
    violation of Part 68 rules. This equip ment returns answer-sup ervision sig nals to 
    the p ub lic  switc hed network when:
    nAnswered  b y the c alled  station
    nAnswered  b y the attend ant
    nRouted  to a rec ord ed  announc ement that c an b e ad ministered  b y the CPE 
    user
    This eq uip ment returns answer-sup ervision sig nals on all DID c alls forward ed 
    b ac k to the p ub lic  switc hed telep hone network. Permissib le exc eptions are:
    nA c all is unanswered
    nA b usy tone is rec eived
    nA reorder tone is rec eived
    Luc ent Tec hnolog ies attests that this reg istered  eq uipment is c ap ab le of 
    p rovid ing  users ac c ess to interstate p rovid ers of op erator servic es throug h the 
    use of ac c ess c od es. Modific ation of this eq uip ment b y c all ag g reg ators to b loc k 
    ac c ess d ialing  c od es is a violation of the Telep hone Op erator Consumers Ac t of 
    1990.
    This eq uip ment c omp lies with Part 68 of the FCC Rules. On the rear of this 
    eq uip ment is a lab el that c ontains, among other information, the FCC reg istration 
    numb er and  ring er eq uivalenc e numb er (REN) for this eq uip ment. If req uested , 
    this information must b e p rovid ed  to the telep hone c omp any. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    About This Book 
    xvii Federal Communications Commission Statement 
    The REN is used  to d etermine the q uantity of d evic es whic h may b e c onnec ted  
    to the telep hone line. Exc essive RENs on the telep hone line may result in d evic es 
    not ring ing  in resp onse to an inc oming  c all. In most, b ut not all areas, the sum of 
    RENs should  not exc eed  5.0. To be c ertain of the numb er of d evic es that may b e 
    c onnec ted  to a line, as d etermined  b y the total RENs, c ontac t the loc al telep hone 
    c omp any.
    NOTE:
    REN is not req uired  for some typ es of analog  or d ig ital fac ilities.
    Means of Connection
    Connec tion of this equip ment to the telep hone network is shown in the following  
    tab le.
    If the terminal eq uip ment (DEFINITY
    ® System) c auses harm to the telep hone 
    network, the telep hone c omp any will notify you in ad vanc e that temp orary 
    d isc ontinuanc e of servic e may b e req uired . But if ad vanc e notic e is not prac tic al, 
    the telep hone c omp any will notify the c ustomer as soon as p ossib le. Also, you 
    will be ad vised  of your rig ht to file a c omp laint with the FCC if you b elieve it is 
    nec essary.
    The telep hone c omp any may make c hang es in its fac ilities, eq uip ment, 
    op erations or proc ed ures that c ould  affec t the op eration of the equip ment. If this 
    happens, the telephone c ompany will provide advance notice in order for you to 
    make nec essary mod ific ations to maintain uninterrup ted  servic e.
    If troub le is exp erienc ed  with this eq uip ment, for rep air or warranty information, 
    p lease c ontac t the Tec hnic al Servic e Center at 1-800-248-1234. If the eq uip ment 
    is c ausing  harm to the telep hone network, the telep hone c omp any may req uest 
    that you d isc onnec t the eq uip ment until the p rob lem is resolved .Manufacturer ’s Port 
    Identifier FIC CodeSOC/REN/
    A.S. Code Network Jacks
    Off/On Premises Station OL13C 9.0F RJ2GX, 
    RJ 2 1 X,  RJ 1 1 C
    DID Trunk 02RV2-T 0.0B RJ2GX, RJ21X
    CO Trunk 02GS2 0.3A RJ21X
    CO Trunk 02LS2 0.3A RJ21X
    Tie Trunk TL31M 9.0F RJ2GX
    1.544 Dig ital Interfac e 04DU9-B,C 6.0P RJ48C, RJ48M
    1.544 Dig ital Interfac e 04DU9-BN,KN 6.0P RJ48C, RJ48M
    120A2 Channel Servic e Unit 04DU9-DN 6.0P RJ48C 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    About This Book 
    xviii Federal Communications Commission Statement 
    It is rec ommend ed  that rep airs b e performed  b y Luc ent Tec hnolog ies c ertified  
    tec hnic ians.
    The eq uip ment c annot b e used on p ublic  c oin p hone servic e p rovid ed  b y the 
    telep hone c omp any. Connec tion to p arty line servic e is sub jec t to state tariffs. 
    Contac t the state p ub lic  utility c ommission, p ub lic  servic e c ommission or 
    corporation commission for information.
    This eq uip ment, if it uses a telep hone rec eiver, is hearing  aid  c omp atib le. 
    						
    							Install and Connect the Cabinets 
    1-1 Check Circuit Packs 
    1
    DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    1
    Install and Connect the Cabinets
    This chapter describes how to install the Release 8si Single-Carrier Cabinets.
    Multic arrier Cab inet installation p roc ed ures are p rovid ed  in 
    DEFINITY Enterp rise 
    Communic ations Server Release 8 Installation and  Test for Multic arrier Cab inets
    . 
    Floor p lans and  eq uip ment layouts for typic al system installations are p rovid ed  in 
    DEFINITY Enterp rise Communic ations Server Release 8 System Desc rip tion.
    Check Circuit Packs
    Ensure all c irc uit pac ks are fully inserted  into the prop er slots ac c ord ing  to the 
    Customer Servic e Doc ument (CSD). Rep ort any d isc rep anc ies in c irc uit p ac k 
    type or q uantity to your Luc ent Tec hnologies rep resentative. For d etailed  c irc uit 
    pack descriptions, refer to 
    DEFINITY Enterp rise Communic ations Server Release 
    8 System Desc rip tion
    .
    Release 8si systems c ontain a RISC-b ased  TN790B Proc essor c irc uit p ac k.
    Check Customer’s Order
    Chec k the c ustomer’s order and  the ship ping  p ac king  lists to c onfirm all 
    eq uip ment is p resent. If any eq uip ment is missing , report the information to your 
    Luc ent Tec hnolog ies rep resentative. Chec k the system ad junc ts for d amag e and  
    rep ort all damag e ac c ord ing  to loc al ship p ing  instruc tions. 
    						
    							DEFINITY Enterprise Communication Server Release 8.2
    Installation and Test for Single-Carrier Cabinets  555-233-120  Issue 1
    April 2000
    Install and Connect the Cabinets 
    1-2 How to Correct Shipping Errors 
    1
    How to Correct Shipping Errors
    Defec tive eq uip ment and over-ship p ed  eq uip ment must b e red -tag g ed  and 
    returned  p er the nearest Material Stoc king Loc ation (MSL) instruc tions.
    Short-ship p ed  reports must also b e d irec ted to the nearest Material Stoc king  
    Loc ation (MSL). Contac t the ap p rop riate loc ation for sp ec ific  instruc tions. For 
    Streamlined  Imp lementation in the United  States, c all 1-800-772-5409.
    Unpack and Inspect
    1. Unp ac k the c ab inets from the ship ping  material and  insp ec t for d amag e. 
    Report any shipping damage according to local shipping instructions.
    2. Open and  remove the front door and rear p anels from the c ab inet.
    3. Verify the lab el near the c irc uit b reaker on the p ower sup p ly toward  the 
    rear of eac h c ab inet c orresp onds to the loc al voltag e typ e.
    !DANGER:
    If the lab el is d ifferent than the voltag e typ e at the site, notify your 
    Luc ent Tec hnolog ies rep resentative immed iately for a rep lac ement 
    power supply. Do not
    , und er any c irc umstanc es, c onnec t an 
    inc orrec t p ower supp ly to a p ower sourc e.
    Install Single-Carrier Cabinets
    This sec tion d esc rib es how to p osition and  stac k the c ab inets for all reliab ility 
    configurations.
    !CAUTION:
    Lifting  the c ab inet may req uire two p eop le, as it may weig h as muc h as 130 
    p ounds (60 kilog rams). Use c aution to avoid  injury.
    Before b eginning  the c ab inet installation, c hec k the loc ation of the AC/DC p ower 
    receptacle. The receptacle must be on a separately fused circuit 
    not controlled 
    b y a wall switc h. It must b e loc ated  within 10 feet (3 meters) of the c ab inet, and  
    should  b e loc ated  outsid e the Main Distrib ution Frame (MDF) area. 
    						