Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Installation And Test For Single-Carrier Cabinets Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Connecting and Handling Fiber Optic Cables B-5 Optical Cross-Connect Hardware B 10A Lightguide Connector Panel The 10A Lig htg uid e Connec tor Panel (c omc od e 104141858) mounts in the c utouts of a 100A Lig htg uid e Interc onnec t Unit (LIU). A Lightg uide Interc onnec t Unit (LIU) c ontains two c onnec tor p anels. Eac h c onnec tor p anel c an hold six C2000A-2 Connec tor Coup ling s. The C2000A-2 Connec tor Coup ling (c omc od e 104148028) is used to join multi-mod e fib er op tic c ab les eq uipp ed with ST c onnec tors. It has a thread ed mid sec tion that allows it to b e sc rewed into the 10A Lig htg uid e Connec tor Panel. The C3000A-2 Connec tor Coup ling (c omc od e 105271142) is used to join sing le-mod e fib er op tic c ab les eq uip p ed with ST c onnec tors. It has a thread ed mid sec tion that allows it to b e sc rewed into the 10A Lig htg uid e Connec tor Panel. Lightguide Troughs Two typ es of troug hs are used with op tic al c ross-c onnec t hard ware. The 1A4 troug h sec ures single fib er op tic jumpers routed b etween Lig htg uid e Interc onnec t Unit (LIU) c olumns, and the 1A6 trough is used at the b ottom of a Lightg uid e Interc onnec t Unit (LIU) c olumn to p revent c ab le slac k. Ordering Information Description Comcode 1A4 Lig htg uid e Troug h 104141866 1A6 Lig htg uid e Troug h 104141874
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Connecting and Handling Fiber Optic Cables B-6 Optical Cross-Connect Hardware B Multi-mode Fiber Cable The multi-mod e fib er interc onnec tion c ables are used as patc h c ords and to c onnec t fiber op tic eq uip ment to lig htg uid e c ross-c onnec t and interc onnec t field s. This is a d ual fiber c ab le eq uip p ed with ST c onnec tor p lug s on eac h end . Ta b l e B - 1 p rovid es the availab le c ab le leng ths and assoc iated c omc od e numb ers. Table B-1. Multi-mode Fiber Cable Ordering Information Description Length Comcode Fiber Interc onnec tion Cab le 20 Feet (6.1 m) 407439975 Fiber Interc onnec tion Cab le 25 Feet (7.62 m) 407441427 Fiber Interc onnec tion Cab le 30 Feet (9.14 m) 407441435 Fiber Interc onnec tion Cab le 35 Feet (10.67 m) 407441443 Fiber Interc onnec tion Cab le 40 Feet (12.2 m) 407441450 Fiber Interc onnec tion Cab le 50 Feet (15.2 m) 407441468 Fiber Interc onnec tion Cab le 75 Feet (22.8 m) 407441476 Fiber Interc onnec tion Cab le 100 Feet (30.48 m) 407441484 Fiber Interc onnec tion Cab le 125 Feet (38.1 m) 407441492 Fiber Interc onnec tion Cab le 150 Feet (45.7 m) 407441500 Fiber Interc onnec tion Cab le 175 Feet (53.3 m) 407441518 Fiber Interc onnec tion Cab le 200 Feet (61 m) 407441666
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Connecting and Handling Fiber Optic Cables B-7 Optical Cross-Connect Hardware B Single-mode Fiber Cable The sing le-mod e fib er interc onnec tion c ab les are used as p atc h c ord s and to c onnec t fiber op tic eq uip ment to lig htg uid e c ross-c onnec t and interc onnec t field s. This is a d ual fiber c ab le eq uip p ed with ST c onnec tor p lug s on eac h end . NOTE: 5 and 10d B attenuators are availab le. Contac t your Luc ent Tec hnolog ies rep resentative for more information. Ta b l e B - 2 p rovid es the availab le c ab le leng ths and assoc iated c omc od e numb ers. Table B-2. Single-mode Fiber Cable Ordering Information Description Length Comcode Fiber Interc onnec tion Cab le 20 Feet (6.1 m) 407598325 Fiber Interc onnec tion Cab le 30 Feet (9.14 m) 407598333 Fiber Interc onnec tion Cab le 40 Feet (12.2 m) 407598341 Fiber Interc onnec tion Cab le 50 Feet (15.2 m) 407598358 Fiber Interc onnec tion Cab le 75 Feet (22.8 m) 407598366 Fiber Interc onnec tion Cab le 100 Feet (30.48 m) 407598374 Fiber Interc onnec tion Cab le 125 Feet (38.1 m) 407598390 Fiber Interc onnec tion Cab le 150 Feet (45.7 m) 407598408
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Connecting and Handling Fiber Optic Cables B-8 Labels for Fiber Optic Cables B Labels for Fiber Optic Cables There are two typ es of lab els used with fib er op tic c ab les: nCable labels nCross-c onnec t lab els Cab le lab els are used on the c ab les and c ross-c onnec t lab els are used on the c ross-c onnec t eq uip ment. Cable Labels Cab le lab els, with ad hesive b ac king , are installed on eac h end of a fib er op tic c ab le. Eac h lab el d isp lays the following information: nThe numb ers of the c ab inets, c arriers, and slots c onnec ted b y the c ab le nInformation on the c ab le itself, suc h as c ab le c omc od e numb er, and how it is used Cross-Connect Labels The lab el used with c ross-c onnec t fib er op tic c ab les shows the c ab inet, c arrier and slot numb ers of the sourc e of the c ab le. It also ind ic ates that the c ab le g oes to the Main Distrib ution Frame (MDF). Cleaning Fiber Optic Cables The use of isop rop yl alc ohol is rec ommend ed to p rop erly c lean fiber op tic c ab les. Contac t your Luc ent Tec hnolog ies rep resentative for more information. 1. Moisten a lint-free c loth with isop rop yl alc ohol. 2. Wip e the c eramic ferrule with the c loth. Be sure to wip e the entire leng th of the ferrule and the ferrule tip . 3. Dry the ferrule with air. 4. If the c onnec tor is not being used immediately, c over the c onnec tor with the dust cap.
Connector and Cable Diagrams C-1 C DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 C Connector and Cable Diagrams This c hapter p rovid es c onnec tor and c ab le d iag rams for the DEFINITY Enterp rise Communic ations Server. For c irc uit p ac k and auxiliary eq uip ment c lassific ations; and for auxiliary eq uip ment lead d esig nations, refer to the tab les at the end of Chap ter 5, ‘‘Install and Wire Telep hones and Other Eq uip ment’’. See Fig ure C-1 for Exp ansion Interfac e to Exp ansion Interfac e fib er interc onnec t.
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Connector and Cable Diagrams C-2 C Figure C-1. Expansion Interface to Expansion Interface Fiber (Part 1) +5V +5V GRD XMT_DAT GRD GRD TA * TL* GRD GRD GRD RCV_DAT +5V +5V 002 102 003 103 004 104 005 105 006 106 007 107 008 108(P1) 1 (P1) 26 (P1) 2 (P1) 27 (P1) 3 (P1) 28 (P1) 4 (P1) 29 (P1) 5 (P1) 30 (P1) 6 (P1) 31 (P1) 7 (P1) 329823A/B(P1) 1 (P1) 26 (P1) 2 (P1) 27 (P1) 3 (P1) 28 (P1) 4 (P1) 29 (P1) 5 (P1) 30 (P1) 6 (P1) 31 (P1) 7 (P1) 329823A/B EIEI FS 1 -EI to EI fiber & 9823A/B Fiber Fiber +5V +5V GRD XMT_DAT GRD GRD TA * TL* GRD GRD GRD RCV_DAT +5V +5V002 102 003 103 004 104 005 105 006 106 007 107 008 108 Fr on t FrontFro nt Front Rear RearRear Rear Backplane BackplaneBackplane Backplane Fro ntFront RearRear BackplaneBackplane +5V +5V GRD GRD GRD TA * TL* GRD GRD GRD +5V +5V XMT_DAT RCV_DAT +5V +5V GRD GRD GRD TA * TL* GRD GRD GRD +5V +5V002 102 003 004 104 005 105 006 106 007 008 108 103 107 000 100 001 002 102 003 103 004 104 005 006 106 101 105(J2) 1 (J2) 26 (J2) 2 (J2) 3 (J2) 28 (J2) 4 (J2) 29 (J2) 5 (J2) 30 (J2) 6 (J2) 7 (J2) 32 (J2) 27 (J2) 31 (J1) 1 (J1) 26 (J1) 2 (J1) 3 (J1) 28 (J1) 4 (J1) 29 (J1) 5 (J1) 30 (J1) 6 (J1) 7 (J1) 32 (J1) 27 (J1) 31 SNIEI FS 3 -SNI to EI metallic fiber H600-278 +5V +5V GRD GRD GRD TA * TL* GRD GRD GRD +5V +5V XMT_DAT RCV_DAT +5V +5V GRD XMT_DAT GRD GRD TA * TL* GRD GRD GRD RCV_DAT +5V +5V 002 102 003 103 004 104 005 105 006 106 007 107 008 108(P1) 1 (P1) 26 (P1) 2 (P1) 27 (P1) 3 (P1) 28 (P1) 4 (P1) 29 (P1) 5 (P1) 30 (P1) 6 (P1) 31 (P1) 7 (P1) 329823A/B(P1) 1 (P1) 26 (P1) 2 (P1) 27 (P1) 3 (P1) 28 (P1) 4 (P1) 29 (P1) 5 (P1) 30 (P1) 6 (P1) 31 (P1) 7 (P1) 329823A/B SNIEI FS 2 -SNI to EI fiber & 9823A/B+5V +5V GRD XMT_DAT GRD GRD TA * TL* GRD GRD GRD RCV_DAT +5V +5V000 100 001 101 002 102 003 103 004 104 005 105 006 106 r975bb1a MMR 051096
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Connector and Cable Diagrams C-3 C Figure C-2. Expansion Interface to Expansion Interface Fiber (Part 2) Fro ntFron t RearRear BackplaneBackplane Fro ntFron t RearRear BackplaneBackplane +5V +5V GRD XMT_DAT GRD GRD TA * TL* GRD GRD GRD RCV_DAT +5V +5V(P1) 1 (P1) 26 (P1) 2 (P1) 27 (P1) 3 (P1) 28 (P1) 4 (P1) 29 (P1) 5 (P1) 30 (P1) 6 (P1) 31 (P1) 7 (P1) 329823A/B(P1) 1 (P1) 26 (P1) 2 (P1) 27 (P1) 3 (P1) 28 (P1) 4 (P1) 29 (P1) 5 (P1) 30 (P1) 6 (P1) 31 (P1) 7 (P1) 329823A/B SNISNI FS 5 -SNI to SNI fiber & 9823A/B Fiber +5V +5V GRD XMY_DAT GRD GRD TA * TL* GRD GRD GRD RCV_DAT +5V +5V000 100 001 101 002 102 003 103 004 104 005 105 006 106000 100 001 101 002 102 003 103 004 104 005 105 006 106 +5V +5V GRD GRD GRD TA * TL* GRD GRD GRD +5V +5V XMT_DAT RCV_DAT +5V +5V GRD GRD GRD TA * TL* GRD GRD GRD +5V +5V002 102 003 004 104 005 105 006 106 007 008 108 103 107 002 102 003 004 104 005 105 006 106 007 008 108 103 107(J2) 1 (J2) 26 (J2) 2 (J2) 3 (J2) 28 (J2) 4 (J2) 29 (J2) 5 (J2) 30 (J2) 6 (J2) 7 (J2) 32 (J2) 27 (J2) 31 (J1) 1 (J1) 26 (J1) 2 (J1) 3 (J1) 28 (J1) 4 (J1) 29 (J1) 5 (J1) 30 (J1) 6 (J1) 7 (J1) 32 (J1) 27 (J1) 31 EIEI FS 4 -EI to EI metallic fiber H600-278 +5V +5V GRD GRD GRD TA * TL* GRD GRD GRD +5V +5V XMT_DAT RCV_DAT r975bb1b MMR 051096
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Connector and Cable Diagrams C-4 C Figure C-3. Sample Cross-Connects 103A information outlet T(red) R (green) C1 (yellow) C2 (black)T R Modular cord C1 C2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 501 2 3 4 5 6 7 8 9 10 11 12 G1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 2526 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50BLANK BLANK BLANK BLANK BLANK BLANK BLANK BLANK BLANK1 2 3 4 5 6 7 8 Pinouts TN553 (12 ports) TN726 (8 ports) 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 GRD GSP0/2 LOA* LIA GSP1/3 LOB* LIB GSP3* LOC* LIC RSS0* LOD* LID CPERXD PTD* RES FLT* CHG RT* PSSG +5E GRDE GRDE TA * GRDE GRDE +5EGRD GSP0* LOA LIA* GSP1* LOB LIB* GSP2* LOC LIC* RSS1* LOD LID* CPETXD BAT DISC* ON RES* ENVB* PSS +5E RCV DAT* GRDE TL* GRDE XMT DAT* +5E50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 TN1654 Amphenol pinouts 1 226 27 2 327 28 Example cross connect Amphenol pinouts TN553 TN762B 123456789101112 123456789101112 110 blockOne port One port (TN553) 110 block(TN726B) Etc. (48)LOA (23)LOA* (22)LIA (47)LIA* (45)LOB (20)LOB* (19)LIB (44)LIB* (42)LOC (17)LOC* (16)LIC (41)LIC* (39)LOD (14)LOD* (13)LID (38)LID* (48)LOA (23)LOA* (22)LIA (47)LIA* (45)LOB (20)LOB* (19)LIB (44)LIB* (42)LOC (17)LOC* (16)LIC (41)LIC* (39)LOD (14)LOD* (13)LID (38)LID* TN1654 to TN1654 direct cross connect r975bb2 MMR 051396
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Connector and Cable Diagrams C-5 C Figure C-4. Sample Cable Pinouts
DEFINITY Enterprise Communication Server Release 8.2 Installation and Test for Single-Carrier Cabinets 555-233-120 Issue 1 April 2000 Connector and Cable Diagrams C-6 C Figure C-5. Sample Pinouts